Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NCSP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Benchmark of the Kilowatt Reactor Using Stirling TechnologY (KRUSTY) Component Critical Configurations

Kilowatt Reactor Using Stirling TechnologY (KRUSTY) was a prototype for the U.S. National Aeronautics and Space Administration’s Kilopower Program. KRUSTY has a highly enriched uranium–molybdenum alloy (with 7.65 wt% molybdenum) annular core reflected by beryllium oxide with an outer stainless steel shield. Five configurations from the experimental campaign were chosen to be evaluated as benchmark cases. Uncertainties were evaluated in five categories: (1) criticality measurement, (2) mass and density, (3) dimensions, (4) material compositions, and (5) positioning. The largest contribution to the overall uncertainty in each case was from the radial alignment of the movable platen. A simplified model was created to increase computational efficiency, and an average bias of –16 pcm was calculated due to the simplifications. Sample calculations were completed for each case using MCNP6.2, COG, and MC21, all with ENDF/B-VIII.0 nuclear data. For MCNP6.2, the average difference (absolute value) between the calculated and experimental $k_{eff}$ for the five configurations was 14 pcm for both the detailed and the simplified models. The $k_{eff}$ results from all three codes are within 1σ of the benchmark values. KRUSTY’s value as a benchmark is due to its sensitivity to beryllium and molybdenum. For beryllium, KRUSTY adds an 18th benchmark with a total cross-section sensitivity greater than 0.05%/%/(unit lethargy). For molybdenum, KRUSTY adds a 9th benchmark with a total cross-section sensitivity greater than 0.004%/%/(unit lethargy).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Results of Three Neutron Diagnosed Subcritical Experiments

Neutron diagnosed subcritical experiments (NDSEs) aim to measure the fission chain decay of subcritical test objects initiated by neutrons from an external source. The ultimate goal of future NDSEs is to make such measurements on dynamic subcritical objects as they are imploded. In this work, as a step toward that goal, we made measurements on three static subcritical assemblies containing highly enriched uranium. Specifically, we measured the die-off of both fission gamma rays and neutrons, with nanosecond resolution over several hundred microseconds, relative to the emission time of neutrons from a source in close proximity to the subcritical objects. Additionally, as simulations are expected to play a key role in interpreting future NDSEs, we compared our data to detailed MCNP® calculations. There was good agreement between the data and MCNP over die-off times expected to be most important to future NDSEs, but there were significant differences at both earlier and later times. We attempted to reconcile these differences by several changes to the simulations. In particular, we found that reducing the 235U(n,n’) cross section to 80% of the current ENDF7.1 evaluation resulted in much better agreement.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Derivation of the Two-Exponential Probability Density Function for Rossi-Alpha Measurements of Reflected Assemblies and Validation for the Special Case of Shielded Measurements

Rossi-alpha measurements of fissionable assemblies are used to estimate the prompt neutron decay constant, α, of a system, which can be used to infer reactivity. Previous works have demonstrated that two-exponential fits for Rossi-alpha measurements of reflected assemblies are better than one exponential fits; however, the two-exponential probability density function that is needed to obtain α from the fit parameters has not been derived. This paper derives the two-region point kinetics model (two-exponential fit) for Rossi-alpha measurements, a generalization of the current, one region model (one-exponential fit). The new model is validated with measurements of reflected, fissionable assemblies (highly enriched uranium with k eff ≈ 0.95 and weapons-grade plutonium with k eff > 0.77) with α held constant. Here, the results show that the twoexponential model can (i) predict the constant α, and (ii) deconvolve α and the time a neutron spends in the reflector, neither of which is possible with the one-exponential model.

42 ENGINEERING↗

Systematic Measurements and Analyses for Lead Void Reactivity Worth in a Plutonium Core and Two Uranium Cores with Different Enrichments

To validate lead (Pb) nuclear cross sections, a series of integral experiments to measure lead void reactivity worth was conducted systematically in three fast neutron spectra with different fuel compositions on the Comet critical assembly of the National Criticality Experiments Research Center. Previous experiments in high-enriched uranium (HEU)/Pb and low-enriched uranium (LEU)/Pb systems had been performed in 2016 and 2017, respectively. A follow-on experiment in a plutonium (Pu)/Pb system has been completed. The Pu/Pb system was constructed using lead plates and weapons-grade Pu plates that had been used in the Zero Power Physics Reactor (ZPPR) of Argonne National Laboratory until the 1990s. Furthermore, the HEU/Pb system was reexamined on the Comet critical assembly with a newly installed device that can measure the compression of the stack, improving reproducibility. Using the lead void reactivity worth measured in these three cores with different fuel compositions, the latest nuclear data libraries, JENDL-4.0 and ENDF/B-VIII.0, were tested with the Monte Carlo calculation code MCNP® version 6.1. As a result, the calculations by ENDF/B-VIII.0 were confirmed to agree with lead void reactivity worth measured in all the cores. It was furthermore found that the calculations by JENDL-4.0 overestimate by more than 20% for the Pu/Pb core while being in good agreement for the HEU/Pb and LEU/Pb cores.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Methodology for Generating Covariance Data of Thermal Neutron Scattering Cross Sections

This paper details and implements a framework for evaluating thermal neutron scattering cross sections that provide S(α,β) data and covariance data for hydrogen in light water. This methodology involves perturbing model parameters of molecular dynamics potentials and fitting the simulation results to experimental data. The framework is general and can be applied to any material or simulation method. The fit is made using the Unified Monte Carlo method to experimentally measure double-differential scattering cross sections of light water at the Spallation Neutron Source at Oak Ridge National Laboratory. Mean values and covariance data were generated for model parameters, phonon density of states, double-differential cross sections, and total scattering cross sections. These posterior parameter values were very similar to their prior values with a maximum relative error of 0.54%. This falls within in the Unified Monte Carlo–calculated uncertainties on the order of 2.7%. Additionally, posterior double-differential cross sections agree favorably with ENDF/B-VIII.0 cross sections. The new thermal scattering law was tested by comparing it against benchmarks from the International Criticality Safety Benchmark Evaluation Project Handbook, which showed a slight improvement over the ENDF/B-VIII.0 library. Additionally, the covariance matrix of the phonon density of states was validated to confirm that the spread of k eff from the density of states used to generate the covariance matrix was similar to the spread of k eff from the density of states of the sampled covariance matrix.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Generation of the Thermal Scattering Law of Uranium Dioxide with Ab Initio Lattice Dynamics to Capture Crystal Binding Effects on Neutron Interactions

Scattering of thermal neutrons and Doppler broadening of epithermal neutron resonances in uranium and its compounds may be sensitive to crystal binding. The thermal scattering law (TSL) for uranium dioxide, which captures crystal binding effects, has been reevaluated for ENDF/B-VIII.0. Phonon spectra were generated using ab initio lattice dynamics for the paramagnetic phase and validated against experiment. Improved agreement with the Debye-Waller coefficient as a function of temperature is found relative to the spectrum used for the ENDF/B-VII.1 evaluation. The TSL was generated using the phonon expansion method within the NJOY nuclear data processing package and was found to be in reasonable agreement with inelastic neutron scattering measurements. The present evaluation predicts a reduction in the inelastic scattering cross section relative to ENDF/B-VII.1 and a total scattering cross section consistent with neutron transmission experiments

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of Continuous-Energy ENDF/B-VIII.0 16 O, 56 Fe, and 63,65 Cu Cross Sections for Nuclear Criticality Safety Applications

Recently completed cross-section evaluations sponsored in part by the Nuclear Criticality Safety Program were incorporated into the 2018 release of the ENDF/B-VIII.0 cross-section library. Evaluated isotopes of interest to the nuclear data and criticality safety community include 16 O, 56 Fe, and 63,65 Cu. For performance validation, benchmark models defined in the International Criticality Safety Benchmark Evaluation Project Handbook were selected based on energy-integrated k eff sensitivities to total cross sections of interest and compared with experimental values. Of the 102 benchmark configurations that were utilized, 63 are sensitive to 16 O, 32 sensitive to 63,65 Cu, and 25 sensitive to 56 Fe. Selected benchmarks were modeled in SCALE 6.2.3 Criticality Safety Analysis Sequence (CSAS) continuous-energy Monte Carlo k eff calculations with ENDF/B-VII.1, with a hybrid ENDF/B-VII.1 with ENDF/B-VIII.0 data substituted for individual isotopes of interest, and with ENDF/B-VIII.0. ENDF/B-VIII.0 showed improved agreement with experimental k eff for 56 Fe, 63 Cu, elemental copper, and full library substitution while producing lessened agreement for 16 O and 65 Cu. Furthermore, with full library and isotope-specific ENDF/B-VIII.0 performance, a best-case ENDF library was formed by excluding underperforming isotopes’ ENDF/B-VIII.0 data, reverting 16 O and 65 Cu cross sections to ENDF/B-VII.1. This resulted in the average relative deviation between calculated and experimental data improving from 1.45σ for the ENDF/B-VIII.0 library to 1.32σ for the best-case library, relative to benchmark uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A New Era of Nuclear Criticality Experiments: The First 10 Years of Radiation Test Object Operations at NCERC

The work presented in this paper focuses on the first 10 years (2011–2020) of radiation test object (RTO) operations at the National Criticality Experiments Research Center. RTOs are subcritical configurations of special nuclear material that are built by hand. These configurations are utilized for benchmark experiments, detector testing/characterization, and training. An overview of the types of measurements used in RTO operations is given as well as a history of RTO operations at Los Alamos National Laboratory from 1944–2011.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A New Era of Nuclear Criticality Experiments: The First 10 Years of Godiva IV Operations at NCERC

The work presented in this paper focuses on the first 10 years (2011–2020) of Godiva IV operations at the National Criticality Experiments Research Center (NCERC). Godiva IV is a fast burst critical assembly constructed of approximately 65 kg of highly enriched uranium fuel alloyed with 1.5% molybdenum for strength. Godiva is one of the last such critical assemblies in the United States and can be used for studies of super-prompt-critical behavior as well as irradiations and demonstrations. An overview of the startup of Godiva IV at NCERC is given followed by a summary of the experiments performed utilizing Godiva IV over the first 10 years of operation at NCERC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Era of Nuclear Criticality Experiments: The First 10 Years of Flattop Operations at NCERC

The Flattop critical assembly was built and operated from 1958 through 2004 at the Pajarito Site (Technical Area-18), home to the Los Alamos Critical Experiments Facility. Flattop was disassembled in 2005 and refurbished over the course of 3 years. In 2008, Flattop was installed in the National Criticality Experiments Research Center (NCERC) located in the Device Assembly Facility at the Nevada National Security Site. Startup of Flattop with a uranium core occurred in 2011. This paper details the first 10 years of Flattop operations at NCERC (2011–present).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Era of Nuclear Criticality Experiments: The First 10 Years of Comet Operations at NCERC

Comet is a general-purpose, heavy-duty, vertical-lift assembly designed for flexibility in conducting a variety of critical experiments. It is currently located at the National Criticality Experiments Research Center (NCERC) in Nevada. In the past, Comet resided at Technical Area-18 in Los Alamos, New Mexico, as part of the Los Alamos Critical Experiments Facility (LACEF). The Comet assembly was relocated to NCERC in 2008 and became fully operational in June of 2011. The first critical experiment performed on Comet at NCERC was a verification of one of the previous configurations of the Zeus experiment series. Over the next 10 years, many additional experiments followed including other Zeus configurations as well as completely new designs. This paper discusses the Comet vertical-lift assembly, the transition from LACEF to NCERC, and a selection of experiments that have been performed on Comet during its first 10 years of operation at NCERC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Era of Nuclear Criticality Experiments: The First 10 Years of Planet Operations at NCERC

Planet is a vertical-lift assembly machine currently located at the National Criticality Experiments Research Center (NCERC) at the Nevada National Security Site. In the past, Planet resided at Technical Area-18 in Los Alamos, New Mexico, as part of the Los Alamos Critical Experiments Facility (LACEF). Following the de-inventorying of LACEF, the Planet assembly was relocated to NCERC in 2008 and became fully operational in June of 2011. The Class Foils experiment, which involves stacking highly enriched uranium foils to obtain a critical configuration, was the first critical experiment performed on Planet. As a major component of the Nuclear Criticality Safety Class taught for the U.S. Department of Energy (DOE) Nuclear Criticality Safety Program, the Class Foils experiment allows personnel from all over the DOE complex to handle nuclear material and to complete the approach to critical safely and successfully. This paper describes the Planet vertical assembly and recent engineering upgrade and a selection of the experiments that have been performed on Planet since its transition to NCERC 10 years ago.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of Neutron Scattering from a Copper Sample Using a Quasi-Differential Method in the Region from 2 keV to 20 MeV

Neutron scattering from a copper sample was measured at Rensselaer Polytechnic Institute utilizing the quasi-differential method. The measurement spanned the energy range from 0.5 to 20 MeV using the high-energy scattering system and from 2 keV to 0.5 MeV using the new mid-energy scattering system. Copper was selected as a material of interest to measure due to large discrepancies between experiments and simulations of the Zeus benchmark. The Zeus benchmark consists of a copper reflected highly enriched uranium system, and the angular distribution of copper scattering was thought to potentially be the cause of the discrepancy. The copper measurements found differences in the scattering response particularly in the incident energy region from 1 to 2 MeV for the high-energy measurement and from 2 to 4 keV in the mid-energy system. These differences are particularly noticeable at angles near 90 deg in the high-energy system and back angles in the mid-energy system. Additionally, for ENDF/B-VIII.0 there is a large discrepancy at the forward angle in the energy range around 0.5 MeV. For these reasons, a new evaluation of copper scattering utilizing these results is recommended and perhaps could help to improve the agreement with the Zeus benchmarks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncertainty Quantification of a Light Water Pulsed-Neutron Die-Away Experiment to Thermal Neutron Scattering Laws

Thermal neutron scattering laws are important nuclear data for many nuclear science and engineering applications. Validation helps to ensure that a thermal neutron scattering law has a high quality and often employs critical benchmarks as integral experiments. Recently, pulsed-neutron die-away benchmarks have been used as an experiment to validate thermal neutron scattering laws. Herein, we evidence how this alternative integral experiment has a high sensitivity to these nuclear data by performing an uncertainty quantification analysis. The analysis randomly sampled the nuclear model parameters associated with hydrogen bound in light water thermal neutron scattering law and sampled other nuclear data that influenced the experiment’s integral parameter (e.g., elastic scattering, absorption in hydrogen and oxygen) from their respective covariance matrices. The thermal neutron scattering law caused an uncertainty in the integral parameter that reached 2.67%, which exceeds by an order of magnitude the uncertainties induced in commonly used thermal solution critical benchmarks. The validation performed here, although limited due to a poor description of the historical experiment, indicated that the ENDF/B-VIII.0 thermal neutron scattering law well predicted the integral parameter. These results motivate further benchmark and validation efforts using pulsed-neutron die-away experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Benchmark of Neutron Thermalization in Graphite Using a Pulsed Slowing-Down-Time Experiment

A benchmark has been developed using a pulsed slowing-down-time experiment to isolate the thermalization process in graphite. The experiment was conducted at the Oak Ridge Electron Linear Accelerator facility at Oak Ridge National Laboratory, and it measured the time spectrum of neutrons leaking from a graphite pile during slowing down and thermalization within graphite. Simulations of the benchmark experiment were performed using the MCNP6.1 Monte Carlo code and the ENDF/B-VII.1 and ENDF/B-VIII.0 cross-section databases. The benchmark provides a time spectrum (i.e., time-dependent counts in a detector) that allows for validation of the graphite thermal scattering libraries (TSLs). The impact on the simulations using a suite of graphite TSLs was compared with the experimental results. Given the density of nuclear graphite, the TSL corresponding to graphite with 30% porosity, as implemented in ENDF/B-VIII.0, was found to most accurately represent the measured time spectrum corresponding to the thermal energy range with an average deviation of ±1.7%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗