The Random Ray Method Versus Multigroup Monte Carlo: The Method of Characteristics in OpenMC and SCONE

The Random Ray Method (TRRM) is a recently developed approach to solving neutral particle transport problems based on the Method of Characteristics. While the method previously has been implemented only in closed-source or limited-functionality codes, this work describes its implementation in two open-source Monte Carlo codes: OpenMC and SCONE. The random ray implementations required small modifications to the existing Multigroup Monte Carlo (MGMC) solvers, offering a rare venue for redundant, fine-grained, "apples-to-apples" speed and accuracy comparisons between transport methods. To this end, TRRM and MGMC solvers are evaluated against each other using each code's native capabilities on reactor eigenvalue problems with different degrees of energy discretization. On the C5G7 benchmark (featuring only seven energy groups), TRRM achieves a maximum pin power error comparable to or lower than that of MGMC for a given run time. On a problem with 69 energy groups, MGMC is found to scale more efficiently, obtaining a lower pin power error for a given run time. However, the defining difference between the two transport methods is found to be their vastly different uncertainty distributions. Specifically, TRRM is found to maintain similar levels of accuracy and uncertainty throughout the simulation domain whereas MGMC can exhibit orders-of-magnitude greater errors in areas of the problem that feature low neutron flux. For instance, TRRM provided an up to 373 times speed advantage compared with MGMC for computing the flux in low-flux regions in the moderator surrounding the C5G7 core.

42 ENGINEERING↗

Generalized Sensitivity Calculation in the Monte Carlo Wielandt Method

Recently the Monte Carlo (MC) adjoint-weighted perturbation (AWP) methods with k-adjoint have been developed for the k sensitivity calculations. In order to extend the MC AWP methods to estimate sensitivities of a ratio of two reaction rates, Perfetti and Rearden devised a MC sensitivity calculation method with the generalized adjoint expressed by the intra-generational and intergenerational effects. Aufiero et al. suggested the collision history-based approach to calculate sensitivities of responses in the form of ratios of linear or bilinear functions by applying the correlated sampling for multi-generational collisions. However these methods may require a huge size of computer memory to save inter-generational contributions proportional to the number of the sensitivity tallies. In order to reduce memories required for the k-adjoint estimation, the present authors proposed the AWP algorithm in the MC Wielandt method where multiple generations from a fission source neutron are simulated in single history calculations. In this paper, we present perturbation formulations to estimate sensitivities for general tallies such as volume flux, reaction rates, etc. in the MC Wielandt calculations. The proposed method has been implemented into the Seoul National University MC code, McCARD and tested in two-group infinite homogeneous problems. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coupling Deterministic and Monte Carlo Transport Methods for the Simulation of Gamma-Ray Spectroscopy Scenarios

Radiation transport modeling methods used in the radiation detection community fall into one of two broad categories: stochastic (Monte Carlo) and deterministic. Monte Carlo methods are typically the tool of choice for simulating gamma-ray spectrometers operating in homeland and national security settings (e.g. portal monitoring of vehicles or isotope identification using handheld devices), but deterministic codes that discretize the linear Boltzmann transport equation in space, angle, and energy offer potential advantages in computational efficiency for many complex radiation detection problems. This paper describes the development of a scenario simulation framework based on deterministic algorithms. Key challenges include: formulating methods to automatically define an energy group structure that can support modeling of gamma-ray spectrometers ranging from low to high resolution; combining deterministic transport algorithms (e.g. ray-tracing and discrete ordinates) to mitigate ray effects for a wide range of problem types; and developing efficient and accurate methods to calculate gamma-ray spectrometer response functions from the deterministic angular flux solutions. The software framework aimed at addressing these challenges is described and results from test problems that compare coupled deterministic-Monte Carlo methods and purely Monte Carlo approaches are provided.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

SU-E-T-285: Dose Variation at Bone in Small-Animal Irradiation: A Monte Carlo Study Using Monoenergetic Photon Beams

Purpose: The aim of this study is to investigate the variation of bone dose on photon beam energy (keV – MeV) in small-animal irradiation. Dosimetry of homogeneous and inhomogeneous phantoms as per the same mouse computed tomography image set were calculated using the DOSCTP and DOSXYZnrc based on the EGSnrc Monte Carlo code. Methods: Monte Carlo simulations for the homogeneous and inhomogeneous mouse phantom irradiated by a 360 degree photon arc were carried out. Mean doses of the bone tissue in the irradiated volumes were calculated at various photon beam energies, ranging from 50 keV to 1.25 MeV. The effect of bone inhomogeneity was examined through the Inhomogeneous Correction Factor (ICF), a dose ratio of the inhomogeneous to the homogeneous medium. Results: From our Monte Carlo results, higher mean bone dose and ICF were found when using kilovoltage photon beams compared to megavoltage. In beam energies ranging from 50 keV to 200 keV, the bone dose was found maximum at 50 keV, and decreased significantly from 2.6 Gy to 0.55 Gy, when 2 Gy was delivered at the center of the phantom (isocenter). Similarly, the ICF were found decreasing from 4.5 to 1 when the photon beam energy was increased from 50 keV to 200 keV. Both mean bone dose and ICF remained at about 0.5 Gy and 1 from 200 keV to 1.25 MeV with insignificant variation, respectively. Conclusion: It is concluded that to avoid high bone dose in the small-animal irradiation, photon beam energy higher than 200 keV should be used with the ICF close to one, and bone dose comparable to the megavoltage beam where photoelectric effect is not dominant.

60 APPLIED LIFE SCIENCES↗

Modeling of the SPERT Transients Using SERPENT2 with Time Dependent Capabilities

Over the last decade, multiphysics coupled calculations have become one of the most important research topics in the area of development and enhancement of reactor analysis and simulation tools. One of the main applications of these coupled simulations is transient analysis, which may involve modeling of experiments, normal plant operation or accident scenarios. Traditionally, the reactor physics side of coupled simulations has been represented by deterministic or hybrid Monte Carlo - deterministic methods. Monte Carlo techniques are limited by their high computational cost. However increased computing power makes their application to multiphysics modeling of transients feasible. Active research is underway to develop algorithms for time dependent calculations, implement them in Monte Carlo codes, and evaluate their performance. In this paper time dependent simulations of the SPERT experiments using the Serpent2 code are presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Stochastic Simulations and Sensitivity Analysis of Plasma Flow

For complex physical systems with large number of random inputs, it will be very expensive to perform stochastic simulations for all of the random inputs. Stochastic sensitivity analysis is introduced in this paper to rank the significance of random inputs, provide information on which random input has more influence on the system outputs and the coupling or interaction effect among different random inputs. There are two types of numerical methods in stochastic sensitivity analysis: local and global methods. The local approach, which relies on a partial derivative of output with respect to parameters, is used to measure the sensitivity around a local operating point. When the system has strong nonlinearities and parameters fluctuate within a wide range from their nominal values, the local sensitivity does not provide full information to the system operators. On the other side, the global approach examines the sensitivity from the entire range of the parameter variations. The global screening methods, based on One-At-a-Time (OAT) perturbation of parameters, rank the significant parameters and identify their interaction among a large number of parameters. Several screening methods have been proposed in literature, i.e., the Morris method, Cotter's method, factorial experimentation, and iterated fractional factorial design. In this paper, the Morris method, Monte Carlo sampling method, Quasi-Monte Carlo method and collocation method based on sparse grids are studied. Additionally, two MHD examples are presented to demonstrate the capability and efficiency of the stochastic sensitivity analysis, which can be used as a pre-screening technique for reducing the dimensionality and hence the cost in stochastic simulations.

30 DIRECT ENERGY CONVERSION↗

A compact neutron spectrometer system

A portable neutron spectrometer, nSpec, has been developed for passive interrogation of fast neutrons ( 1 MeV) from neutron sources. The design of the system includes four EJ-301 liquid scintillation cells, a custom stand, and tungsten caps for gamma-ray shielding. Data acquisition settings were optimized to provide a dynamic range of up to > 15 MeV neutron energy. Additionally, the detector response matrix was characterized using a time-of-flight method based on gamma-ray tagged neutron emission from 252 Cf. The spectrum unfolding was characterized using measured and simulated spectra of AmBe and 252 Cf with the GRAVEL and MLEM methods. Monte Carlo methods were used to examine the uncertainty propagation and determine sufficient counts for a measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo Calculations of Polarized Microwave Radiation Emerging from Cloud Structures

The last decade has seen tremendous growth in cloud dynamical and microphysical models that are able to simulate storms and storm systems with very high spatial resolution, typically of the order of a few kilometers. The fairly realistic distributions of cloud and hydrometeor properties that these models generate has in turn led to a renewed interest in the three-dimensional microwave radiative transfer modeling needed to understand the effect of cloud and rainfall inhomogeneities upon microwave observations. Monte Carlo methods, and particularly backwards Monte Carlo methods have shown themselves to be very desirable due to the quick convergence of the solutions. Unfortunately, backwards Monte Carlo methods are not well suited to treat polarized radiation. This study reviews the existing Monte Carlo methods and presents a new polarized Monte Carlo radiative transfer code. The code is based on a forward scheme but uses aliasing techniques to keep the computational requirements equivalent to the backwards solution. Radiative transfer computations have been performed using a microphysical-dynamical cloud model and the results are presented together with the algorithm description.

Kummerow, Christian↗

Stability analysis and time-step limits for a Monte Carlo Compton-scattering method

A Monte Carlo method for simulating Compton scattering in high energy density applications has been presented that models the photon-electron collision kinematics exactly [E. Canfield, W.M. Howard, E.P. Liang, Inverse Comptonization by one-dimensional relativistic electrons, Astrophys. J. 323 (1987) 565]. However, implementing this technique typically requires an explicit evaluation of the material temperature, which can lead to unstable and oscillatory solutions. In this paper, we perform a stability analysis of this Monte Carlo method and develop two time-step limits that avoid undesirable behavior. The first time-step limit prevents instabilities, while the second, more restrictive time-step limit avoids both instabilities and nonphysical oscillations. With a set of numerical examples, we demonstrate the efficacy of these time-step limits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Variance Estimation in Monte Carlo Eigenvalue Simulations Using Spectral Analysis Method

Monte Carlo (MC) simulation is widely used to solve the eigenvalue form of the Boltzmann transport equation that mathematically represents the neutron transport process through complex multiplying (fissionable) systems. Monte Carlo eigenvalue simulation starts with an assumed fission source distribution and uses the fission sites from the previous iteration (cycle) as the starting source in the current iteration. Important system parameters (MC tallies) such as fuel pin-power distribution are estimated over several cycles after the convergence of the fission source distribution to a stationary distribution. However, the MC fission source iteration algorithm that uses fission source sites from the previous cycle introduces a cycle-to-cycle correlation. Monte Carlo simulations that do not account for the cycle-to-cycle correlation systematically underestimate the variance of the estimated system parameters (sample mean). This paper presents the relationship between the spectral density in the frequency domain at frequency zero and the variance of the sample mean. This paper introduces a novel method in the frequency domain for the MC variance estimation. For the three test problems used in this paper, researchers have observed that the new method results in an improvement of more than one order of magnitude to the standard deviation of the sample mean. The new method also compares favorably with the previously introduced batch, bootstrap, and covariance-adjusted methods when applied to the three test problems investigated in this paper. This new method does not require modification of the MC eigenvalue algorithm (power iteration), is code agnostic, and is therefore easy to use when implementing in any existing MC code. In conclusion, the new estimate can be calculated without saving tally results of all active/stationary cycles.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monte Carlo simulation methods in moment-based scale-bridging algorithms for thermal radiative-transfer problems

We present a moment-based acceleration algorithm applied to Monte Carlo simulation of thermal radiative-transfer problems. Our acceleration algorithm employs a continuum system of moments to accelerate convergence of stiff absorption–emission physics. The combination of energy-conserving tallies and the use of an asymptotic approximation in optically thick regions remedy the difficulties of local energy conservation and mitigation of statistical noise in such regions. We demonstrate the efficiency and accuracy of the developed method. We also compare directly to the standard linearization-based method of Fleck and Cummings [1]. A factor of 40 reduction in total computational time is achieved with the new algorithm for an equivalent (or more accurate) solution as compared with the Fleck–Cummings algorithm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved criticality convergence via a modified Monte Carlo iteration method

Nuclear criticality calculations with Monte Carlo codes are normally done using a power iteration method to obtain the dominant eigenfunction and eigenvalue. In the last few years it has been shown that the power iteration method can be modified to obtain the first two eigenfunctions. This modified power iteration method directly subtracts out the second eigenfunction and thus only powers out the third and higher eigenfunctions. The result is a convergence rate to the dominant eigenfunction being |k{sub 3}|/k{sub 1} instead of |k{sub 2}|/k{sub 1}. One difficulty is that the second eigenfunction contains particles of both positive and negative weights that must sum somehow to maintain the second eigenfunction. Summing negative and positive weights can be done using point detector mechanics, but this sometimes can be quite slow. We show that an approximate cancellation scheme is sufficient to accelerate the convergence to the dominant eigenfunction. A second difficulty is that for some problems the Monte Carlo implementation of the modified power method has some stability problems. We also show that a simple method deals with this in an effective, but ad hoc manner.

99 GENERAL AND MISCELLANEOUS↗

Dynamic load balancing for petascale quantum Monte Carlo applications: The Alias method

Diffusion Monte Carlo is the most accurate widely used Quantum Monte Carlo method for the electronic structure of materials, but it requires frequent load balancing or population redistribution steps to maintain efficiency and avoid accumulation of systematic errors on parallel machines. The load balancing step can be a significant factor affecting performance, and will become more important as the number of processing elements increases. We propose a new dynamic load balancing algorithm, the Alias Method, and evaluate it theoretically and empirically. An important feature of the new algorithm is that the load can be perfectly balanced with each process receiving at most one message. It is also optimal in the maximum size of messages received by any process. We also optimize its implementation to reduce network contention, a process facilitated by the low messaging requirement of the algorithm. Empirical results on the petaflop Cray XT Jaguar supercomputer at ORNL showing up to 30% improvement in performance on 120,000 cores. The load balancing algorithm may be straightforwardly implemented in existing codes. The algorithm may also be employed by any method with many near identical computational tasks that requires load balancing.

97 MATHEMATICS AND COMPUTING↗

Precision benchmark calculations for four particles at unitarity

The unitarity limit describes interacting particles where the range of the interaction is zero and the scattering length is infinite. We present precision benchmark calculations for two-component fermions at unitarity using three different ab initio methods: Hamiltonian lattice formalism using iterated eigenvector methods, Euclidean lattice formalism with auxiliary-field projection Monte Carlo methods, and continuum diffusion Monte Carlo methods with fixed and released nodes. We have calculated the ground-state energy of the unpolarized four-particle system in a periodic cube as a dimensionless fraction of the ground-state energy for the noninteracting system. We obtain values of 0.211(2) and 0.210(2) using two different Hamiltonian lattice representations, 0.206(9) using Euclidean lattice formalism, and an upper bound of 0.212(2) from fixed-node diffusion Monte Carlo methods. Released-node calculations starting from the fixed-node result yield a decrease of less than 0.002 over a propagation of 0.4E{sub F}{sup -1} in Euclidean time, where E{sub F} is the Fermi energy. We find good agreement among all three ab initio methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Early-stage plasma dynamics with air ionization during ultrashort laser ablation of metal

In this study, the early-stage plasma evolution generated by an ultrashort laser pulse is investigated through pump-probe shadowgraph measurements and simulations. The measurements are performed to show the evolution of the plasma front, while the simulation model is used to further investigate the evolution process and mechanism. Specifically, the laser pulse propagation in air is simulated using the beam propagation method with the slowly varying envelope approximation. The lattice dynamics, the electron dynamics and the multi-scattering event, and the evolution of charged particles (free electrons and ions), are simulated using a molecular dynamics method, a Monte Carlo method, and a particle-in-cell method, respectively. With this simulation model, the refractive index and plasma evolutions are calculated and compared with measured results to validate the simulation model. Different plasma expansion processes, caused by the air ionization, are found with the focal point slightly above and below the target. Air ionization occurs in both cases, but their primary mechanisms are shown to be different.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative Elemental Microanalysis Of Individual Particles With Use Of X-Ray Fluorescence Method And Monte Carlo Simulation

Recently a considerable interest has been triggered in the investigation of the composition of individual particles by X-ray fluorescence microanalysis. The sources of these micro-samples are mostly diversified. These samples come from space dust, air and ash, soil as well as environment and take the shape of a sphere or an oval. In analysis this kind of samples the geometrical effects caused by different sizes and shapes influence on accuracy of results. This fact arises from the matrix effect. For these samples it is not possible to find analytically a solution of equation taking into account an absorption of X-rays. Hence, a way out is to approximate the real sample shape with the other one or to use Monte Carlo (MC) simulation method. In current work authors utilized the iterative MC simulation to assess an elemental percentage of individual particles. The set of glass micro-spheres, made of NIST K3089 material of known chemical composition, with diameters in the range between 25 and 45 {mu}m was investigated. The microspheres were scanned with X-ray tube primary radiation. Results of MC simulation were compared with these of some analytical approaches based on particle shape approximation. An investigation showed that the low-Z elements (Si, Ca, Ti) were the most sensitive on changes of particle shape and sizes. For high-Z elements (Fe--Pb) concentrations were nearly equal regardless of method used. However, for the all elements considered, results of MC simulation were more accurate then these of analytical relationships taken into comparison.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of Monte Carlo accelerated iterative methods for sparse linear systems: Analysis of Monte Carlo accelerated iterative methods for sparse linear systems

Here, we consider hybrid deterministic-stochastic iterative algorithms for the solution of large, sparse linear systems. Starting from a convergent splitting of the coefficient matrix, we analyze various types of Monte Carlo acceleration schemes applied to the original preconditioned Richardson (stationary) iteration. We expect that these methods will have considerable potential for resiliency to faults when implemented on massively parallel machines. We also establish sufficient conditions for the convergence of the hybrid schemes, and we investigate different types of preconditioners including sparse approximate inverses. Numerical experiments on linear systems arising from the discretization of partial differential equations are presented.

97 MATHEMATICS AND COMPUTING↗