Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Machine-Learning-based Algorithms for Automated Image Segmentation Techniques of Transmission X-ray Microscopy (TXM)

Four state-of-the-art Deep Learning-based Convolutional Neural Networks (DCNN) were applied to automate the semantic segmentation of a 3D Transmission x-ray Microscopy (TXM) nanotomography image data. The standard U-Net architecture as baseline along with UNet++, PSPNet, and DeepLab v3+ networks were trained to segment the microstructural features of an AA7075 micropillar. A workflow was established to evaluate and compare the DCNN prediction dataset with the manually segmented features using the Intersection of Union (IoU) scores, time of training, confusion matrix, and visual assessment. Comparing all model segmentation accuracy metrics, it was found that using pre-trained models as a backbone along with appropriate training encoder-decoder architecture of the Unet++ can robustly handle large volumes of x-ray radiographic images in a reasonable amount of time. This opens a new window for handling accurate and efficient image segmentation of in situ time-dependent 4D x-ray microscopy experimental datasets.

36 MATERIALS SCIENCE↗

Electron microscopy holdings of the Protein Data Bank: the impact of the resolution revolution, new validation tools, and implications for the future

Abstract As a discipline, structural biology has been transformed by the three-dimensional electron microscopy (3DEM) “Resolution Revolution” made possible by convergence of robust cryo-preservation of vitrified biological materials, sample handling systems, and measurement stages operating a liquid nitrogen temperature, improvements in electron optics that preserve phase information at the atomic level, direct electron detectors (DEDs), high-speed computing with graphics processing units, and rapid advances in data acquisition and processing software. 3DEM structure information (atomic coordinates and related metadata) are archived in the open-access Protein Data Bank (PDB), which currently holds more than 11,000 3DEM structures of proteins and nucleic acids, and their complexes with one another and small-molecule ligands (~ 6% of the archive). Underlying experimental data (3DEM density maps and related metadata) are stored in the Electron Microscopy Data Bank (EMDB), which currently holds more than 21,000 3DEM density maps. After describing the history of the PDB and the Worldwide Protein Data Bank (wwPDB) partnership, which jointly manages both the PDB and EMDB archives, this review examines the origins of the resolution revolution and analyzes its impact on structural biology viewed through the lens of PDB holdings. Six areas of focus exemplifying the impact of 3DEM across the biosciences are discussed in detail (icosahedral viruses, ribosomes, integral membrane proteins, SARS-CoV-2 spike proteins, cryogenic electron tomography, and integrative structure determination combining 3DEM with complementary biophysical measurement techniques), followed by a review of 3DEM structure validation by the wwPDB that underscores the importance of community engagement.

Burley, Stephen K. (ORCID:0000000224879713)↗

Informed unsupervised machine learning analysis of dislocation microstructure from high-resolution differential aperture X-ray structural microscopy data

This study leverages high-resolution differential-aperture X-ray structural microscopy (DAXM) to probe the local dislocation structure in deformed 304L-stainless steel at small strain, by measuring the lattice rotation and deviatoric elastic strain with a sub-micron resolution. For a single grain in a polycrystalline specimen, the measured lattice rotation field over the measured volume exhibited a multimodal distribution while the deviatoric elastic strain showed a single-mode distribution. An unsupervised Cauchy mixture machine learning model was developed to resolve the multimodal distribution of the lattice rotation. By mapping the lattice rotation data associated with each Cauchy peak in the model back onto the measured volume, we identify contiguous regions of the crystal rotated near the average values corresponding to the peaks of the overall rotation distribution. These regions represent the grain subdivision in the microstructure. Finally, the dislocation density tensor was also computed and its norm was laid over the rotation field to detect the subgrain boundaries. This step provided a validation of the Cauchy mixture model for the analysis of the lattice rotation distribution. The current study highlights the integration of advanced X-ray microscopy techniques with data-driven analysis methods to uncover detailed microstructure scales in deformed crystals.

Machine learning; Lattice rotation; High-energy X-↗

Visualization of the surface distribution of photocatalytic activity at the anatase/rutile TiO2 interface using X-ray photoelectron emission microscopy

We applied X-ray photoelectron emission microscopy (XPEEM) to visualize the surface distribution of photocatalytic activity at the anatase/rutile (A/R) interface of titanium dioxide. Acetic acid was adsorbed on the surface, and its decomposition and desorption reactions under ultraviolet light irradiation were monitored by observing C 1s spectra, enabling direct observation of the spatial distribution of photocatalytic activity. Complementary crystal structure information was obtained using spatially resolved low-energy electron diffraction, low-energy electron microscopy, X-ray absorption spectroscopy, and micro-focused Raman spectroscopy. Comparison with these structural data allowed for the evaluation of the photocatalytic activity as a function of the distance from the A/R interface. The activity is enhanced in the vicinity of the interface and gradually decreases toward both the anatase and rutile regions. These results demonstrate that XPEEM is an effective technique for spatially resolved mapping of photocatalytic activity, which has\\r\\npreviously been inaccessible using conventional characterization techniques.

25 ENERGY STORAGE↗

Multimodal hyperspectral optical microscopy

We describe a unique and convenient approach to multimodal hyperspectral optical microscopy, herein achieved by coupling a portable and transferable hyperspectral imager to various optical microscopes. The experimental and data analysis schemes involved in recording spectrally and spatially resolved fluorescence, dark field, and optical absorption micrographs are illustrated through prototypical measurements targeting selected model systems. Namely, hyperspectral fluorescence micrographs of isolated fluorescent beads are employed to ensure spectral calibration of our detector and to gauge the attainable spatial resolution of our measurements; the recorded images are diffraction-limited. Moreover, spatially over-sampled absorption spectroscopy of a single lipid (18:1 Liss Rhod PE) layer reveals that optical densities on the order of 10-3 may be resolved by spatially averaging the recorded optical signatures. We also briefly illustrate two applications of our setup in the general areas of plasmonics and cell biology. Most notably, we deploy hyperspectral optical absorption microscopy to identify and image algal pigments within a single live Tisochrysis lutea cell. Overall, this work paves the way for multimodal multidimensional spectral imaging measurements spanning the realms of several scientific disciples.

47 OTHER INSTRUMENTATION↗

Colocalized Raman spectroscopy – scanning electrochemical microscopy investigation of redox flow battery dialkoxybenzene redoxmer degradation pathways

Non-aqueous redox flow batteries offer high voltages for grid-level energy storage technologies. However, decomposition of the redoxmers - redox-active molecules that make up the anolyte and catholyte in the negative and positive cell compartments - is an important challenge to overcome for long-term storage. Here, we present a spectroelectrochemical study of the catholyte candidate 2,3-dimethyl-1,4-dialkoxybenzene (C7) and its decomposition mechanisms in the presence of a model nucleophilic base, pyridine. We utilize colocalized Raman microscopy and scanning electrochemical microscopy (Raman-SECM) to quantify the chemical rates of decom-position and qualitatively identify the reaction intermediates and products. A detailed study on how the Raman-SECM parameters (electrode distance, substrate electrode, and laser focal height) influence the Raman signal of the charged catholyte C7 ∙+ is presented. Using optimized conditions, we monitored the deprotonation of C7 ∙+ via Raman spectroscopy and the subsequent hydrogen abstraction from solvent molecules to regenerate C7 via electrochemistry. Finite element modeling was used to fit electrochemical and spectroscopic data, quantifying the deprotonation rates as k dep = 2000 and 700 L mol -1 s -1 and abstraction rates as k abs = 0.5 and 0.2 s - 1 in propylene carbonate and acetonitrile solvents, respectively. Our results show the value of spatiotemporal reso-lution in evaluating the chemical and electrochemical behavior of materials for redox flow batteries.

25 ENERGY STORAGE↗

Testing fast reactor fuels in a thermal reactor: Comparison of transmutation metallic fuel alloys behavior by scanning electron microscopy

To optimize nuclear waste repository performance, the destruction of minor actinide elements, particularly Np and Am, in a neutron fast spectrum reactor is possible by incorporating these elements into nuclear fuel. Evaluating the performance of minor actinide containing fuel is of paramount importance to enabling this technology. However, such a task is challenging without an available domestic fast spectrum test reactor. A comparison of fuel performance tested in an available domestic thermal reactor at the Idaho National Laboratory, the Advanced Test Reactor, and in a fast spectrum reactor in France (Phénix) is presented here in this study. This study evaluates the capability of using a cadmium shrouded test position to mimic the power profile along the fuel radius present in fast spectrum reactors so that thermally driven phenomenon (e.g., constituent redistribution) can be evaluated in a thermal reactor and determined to be prototypical of a fast reactor. Thus, optical microscopy and scanning electron microscopy has been performed on irradiated 35U-29Pu-4Am-2Np-30Zr fuel samples (where the number preceding the element is the weight percent concentration) from the two mentioned reactors that present similar irradiation temperatures and power conditions. The results indicate that fuel performance phenomena are reproducible in the two irradiation conditions. The redistribution of Zr occurred in the same manner for the two samples. Similar partitioning of U-Pu-Zr phases was observed, and the behavior of Am was similar in the analyzed specimens. Finally, the overall microstructure evolution seems not to be affected by minor actinides addition compared to expected behavior of conventional U-19Pu-10Zr ternary metal fuels for both specimens. Slight differences in fuel cladding chemical interaction were, however, observed. This difference is likely driven by difference in cladding composition rather than irradiation conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Elucidating microstructural evolution and hardness variation across friction self-piercing riveted Al-7055 using synchrotron X-ray scattering and advanced microscopy techniques

Friction self-piercing riveting (FSPR) is a unique hybrid joining technique that combines the advantages of mechanical interlocking, frictional heat, and solid-state joining (if metallurgically compatible) to produce crack free joints in high strength and/or low-ductility alloys at room temperature. Here, in the current study, Al-7055 sheets were joined using FSPR for lightweight automotive applications and significant microhardness variations were observed across the joint cross-section. A detailed microstructural characterization at multiple length scales was carried out using advanced electron microscopy and X-ray scattering techniques to provide a fundamental understanding of the process-structure-property relationships. The relative contributions of microstructural characteristics at various length scales (i.e., grain size, dislocation density, solute concentration, precipitate nature) to strengthening were estimated using existent formulations (i.e., Hall-Petch, Taylor, precipitate bypass/shear equations) and correlated to the observed microhardness values across different regions. Small-angle X-ray scattering and scanning transmission electron microscopy revealed significant changes in the size and volume fraction of precipitate species, i.e., GP-I Zones, η′, and Mg/Zn solute co-clusters, depending on the process region. It was observed that the dissolution of the small η′/GP-I zones (T ∼ 150–200 °C) in the heat-affected zone were the key reason for the hardness drop. Further, it was shown that solid-solution, dislocation, grain size and solute co-cluster strengthening played a key role in the thermo-mechanically affected zone and grain-refined zone (GRZ). Finally, these observations were leveraged along with the Zener-Holloman relationship and grain size in the GRZ to estimate the peak joining temperature of the GRZ (∼ 350 °C) near the steel rivet.

aluminum 7xxx alloy↗

Preventative studies should begin now for detecting AI-generated microscopy images

With the rapid progress made in artificial intelligence (AI), text, images, and even videos that are often indistinguishable from human-created content can now be easily generated using new AI models. In this essay, we call attention to the potential misuse of advanced AI models to generate microscopy images, as it could challenge reviewers and fraud hunters in an unprecedented way. This concern is more than hypothetical because relevant open-sourced implementations and datasets are widely available. As a result, we urge that preventative studies on methods to detect microscopy image fabrication should begin now before potential misconduct materializes and becomes widespread.

97 MATHEMATICS AND COMPUTING↗

Segmentation method comparison for residual fiber length measurement across tiled microscopy images

Fiber length distribution (FLD), in part, governs mechanical properties in discontinuous fiber composites, yet manual measurement methods limit the high-throughput characterization needed for materials design optimization. This study compares deep learning segmentation approaches for automated FLD measurement in large-field microscopy, evaluating how method choice affects the microstructural descriptors used in structure-property-processing relationships. A critical challenge is that high-resolution microscopy images (10,000×10,000 pixels) must be tiled for deep learning analysis, fragmenting fibers at boundaries. We demonstrate that segmentation method proves crucial for measurement accuracy. For example, instance segmentation with Slicing Aided Hyper Inference (SAHI) preserves individual fiber integrity across tiles while semantic segmentation prioritizes speed. Comparing against manual measurement of extracted carbon fibers, YOLOv11-SAHI matched manual ground truth (238 μm weighted mean) with 40x speedup (4.5 vs 167 minutes per image). U-Net provides rapid quantification although it is at the cost of reduced accuracy due only reliably measuring stand-alone fibers. Our comparative analysis reveals that instance segmentation with SAHI better preserves length measurements while semantic segmentation prioritizes speed, providing empirical guidance for method selection. The characterization provides essential inputs for mechanical property prediction models and inverse design workflows, accelerating composite materials development cycles.

Additive manufacturing↗

EXSCLAIM!: Harnessing materials science literature for self-labeled microscopy datasets

This work introduces the EXSCLAIM! toolkit for the automatic extraction, separation, and caption-based natural language annotation of images from scientific literature. EXSCLAIM! is used to show how rule-based natural language processing and image recognition can be leveraged to construct an electron microscopy data set containing thousands of keyword-annotated nanostructure images. Moreover, it is demonstrated how a combination of statistical topic modeling and semantic word similarity comparisons can be used to increase the number and variety of keyword annotations on top of the standard annotations from EXSCLAIM! With large-scale imaging datasets constructed from scientific literature, users are well positioned to train neural networks for classification and recognition tasks specific to microscopy-tasks often otherwise inhibited by a lack of sufficient annotated training data.

36 MATERIALS SCIENCE↗

Development of a liquid-helium free cryogenic sample holder with mK temperature control for autonomous electron microscopy

The automated and autonomous cryogenic transmission electron microscopy (Cryo-EM) demands a sample holder capable of maintaining temperatures below 10 K with precise control, long holding times, and minimal helium use. Rising to this challenge, we initiated an ambitious project to develop a novel closed-cycle cryocooler-based cryogenic sample holder that operates without the use of liquid helium and the consumption of gaseous helium. Here, this article presents the design, construction, and experimental testing of the initial prototype, which achieves an ultimate temperature of 5.6 K with exceptional stability close to 1mK, while providing a wide temperature control range from 295 K to 5.6 K, marking a clear advancement in cryo-EM holder development. While the prototype was not designed for atomic resolution imaging and thus lacks a sturdy support system to mitigate mechanical vibrations from the cryocooler's pulsed tube, this innovative approach successfully demonstrates proof of concept. It offers unprecedented capabilities for state-of-the-art cryogenic microscopy and microanalysis in materials and biological sciences.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Atomic resolution scanning transmission electron microscopy at liquid helium temperatures for quantum materials

Fundamental quantum phenomena in condensed matter, ranging from correlated electron systems to quantum information processors, manifest their emergent characteristics and behaviors predominantly at low temperatures. This necessitates the use of liquid helium (LHe) cooling for experimental observation. Atomic resolution scanning transmission electron microscopy combined with LHe cooling (cryo-STEM) provides a powerful characterization technique to probe local atomic structural modulations and their coupling with charge, spin and orbital degrees-of-freedom in quantum materials. However, achieving atomic resolution in cryo-STEM is exceptionally challenging, primarily due to sample drifts arising from temperature changes and noises associated with LHe bubbling, turbulent gas flow, etc. In this work, we demonstrate atomic resolution cryo-STEM imaging at LHe temperatures using a commercial side-entry LHe cooling holder. Firstly, we examine STEM imaging performance as a function of He gas flow rate, identifying two primary noise sources: He-gas pulsing and He-gas bubbling. Secondly, we propose two strategies to achieve low noise conditions for atomic resolution STEM imaging: either by temporarily suppressing He gas flow rate using the needle valve or by acquiring images during the natural warming process. Lastly, we show the applications of image acquisition methods and image processing techniques in investigating structural phase transitions in Cr 2 Ge 2 Te 6 , CuIr 2 S 4 , and CrCl 3 . In conclusion, our findings represent an advance in the field of atomic resolution electron microscopy imaging for quantum materials and devices at LHe temperatures, which can be applied to other commercial side-entry LHe cooling TEM holders.

36 MATERIALS SCIENCE↗

Ultralow-temperature cryogenic transmission electron microscopy using a new helium flow cryostat stage

Advances in cryogenic electron microscopy have opened new avenues for probing quantum phenomena in correlated materials. This study reports the installation and performance of a new side-entry condenZero cryogenic cooling system for JEOL (Scanning) Transmission Electron Microscopes (S/TEM), utilizing compressed liquid helium (LHe) and designed for imaging and spectroscopy at ultra-low temperatures. The system includes an external dewar mounted on a vibration-damping stage and a pressurized, low-noise helium transfer line with a remotely controllable needle valve, ensuring stable and efficient LHe flow with minimal thermal and mechanical noise. Performance evaluation demonstrates a stable base temperature of 4.37 K measured using a Cernox bare chip sensor on the holder with temperature fluctuations within ±0.004 K. Complementary in-situ electron energy-loss spectroscopy (EELS) via aluminum bulk plasmon analysis was used to measure the local specimen temperature and validate cryogenic operation during experiments. The integration of cryogenic cooling with other microscopy techniques, including electron diffraction and Lorentz TEM, was demonstrated by resolving charge density wave (CDW) transitions in NbSe2 using electron diffraction, and imaging nanometric magnetic skyrmions in MnSi via Lorentz TEM. In conclusion, this platform provides reliable cryogenic operation below 7 K, establishing a low-drift route for direct visualization of electronic and magnetic phase transformations in quantum materials.

Charge density wave↗

Phase segregation dynamics in mixed-halide perovskites revealed by plunge-freeze cryo-electron microscopy

Mixed-halide lead perovskites, with photoexcited charge-carrier properties suitable for high-efficiency photovoltaics, hold significant promise for high-efficiency tandem solar cells. However, phase segregation under illumination, where an iodide-rich phase forms carrier trap states, remains a barrier to application. This study employs plunge-freeze cryoelectron microscopy to visualize nanoscale phase segregation dynamics in CsPb(Br x I 1–x ) 3 films. By rapidly freezing the illuminated samples, we preserve transient photoexcited ion distributions for high-resolution structural and compositional analysis at the nanoscale. Cryogenic scanning transmission electron microscopy (STEM) techniques (electron energy loss spectroscopy [EELS] and 4D-STEM) captured the dynamics of photo-induced iodine migration from grain boundaries to centers, identified the buildup of anisotropic strain, and captured the heterogeneous evolution of this process within a single grain. These findings provide insight into microscopic phase segregation mechanisms and their dynamics, enhancing our understanding of mixed-halide perovskite photostability.

42 ENGINEERING↗

Scattering Matrix Determination in Crystalline Materials from 4D Scanning Transmission Electron Microscopy at a Single Defocus Value

Recent work has revived interest in the scattering matrix formulation of electron scattering in transmission electron microscopy as a stepping stone toward atomic-resolution structure determination in the presence of multiple scattering. Here, we discuss ways of visualizing the scattering matrix that make its properties clear. Through a simulation-based case study incorporating shot noise, we shown how regularizing on this continuity enables the scattering matrix to be reconstructed from 4D scanning transmission electron microscopy (STEM) measurements from a single defocus value. Intriguingly, for crystalline samples, this process also yields the sample thickness to nanometer accuracy with no a priori knowledge about the sample structure. The reconstruction quality is gauged by using the reconstructed scattering matrix to simulate STEM images at defocus values different from that of the data from which it was reconstructed.

36 MATERIALS SCIENCE↗

Far-Field High-Energy Diffraction Microscopy: A Non-Destructive Tool for Characterizing the Microstructure and Micromechanical State of Polycrystalline Materials

A suite of non-destructive, three-dimensional X-ray microscopy techniques have recently been developed and used to characterize the microstructures of polycrystalline materials. These techniques utilize high-energy synchrotron radiation and include near-field and far-field diffraction microscopy (NF- and FF-HEDM, respectively) and absorption tomography. Several compatible sample environments have also been developed, enabling a wide range of 3D studies of material evolution. In this article, the FF-HEDM technique is described in detail, including its implementation at the 1-ID beamline of the Advanced Photon Source. Examples of how the information obtained from FF-HEDM can be used to deepen our understanding of structure-property-processing relationships in selected materials are presented.

36 MATERIALS SCIENCE↗

Exploring Coupled Extreme Environments via In-situ Transmission Electron Microscopy

In-situ transmission electron microscopy (TEM) provides an avenue to explore time-dependent nanoscale material changes induced by a wide range of environmental conditions that govern material performance and degradation. The In-situ Ion Irradiation TEM (I 3 TEM) at Sandia National Laboratories is a JEOL 2100 microscope that has been highly modified with an array of hardware and software that makes it particularly well suited to explore fundamental mechanisms that arise from coupled extreme conditions. Here, examples pertaining to multibeam ion irradiation, rapid thermal cycling, and nanomechanical testing on the I 3 TEM are highlighted, along with prospective advancements in the field of in-situ microscopy.

47 OTHER INSTRUMENTATION↗