Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Micromachining”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Multimode Bolometer Development for the PIXIE Instrument

The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission concept designed to measure the polarization and absolute intensity of the cosmic microwave background. In the following, we report on the design, fabrication, and performance of the multimode polarization-sensitive bolometers for PIXIE, which are based on silicon thermistors. In particular we focus on several recent advances in the detector design, including the implementation of a scheme to greatly raise the frequencies of the internal vibrational modes of the large-area, low-mass optical absorber structure consisting of a grid of micromachined, ion-implanted silicon wires. With approximately 30 times the absorbing area of the spider-web bolometers used by Planck, the tensioning scheme enables the PIXIE bolometers to be robust in the vibrational and acoustic environment at launch of the space mission. More generally, it could be used to reduce microphonic sensitivity in other types of low temperature detectors. We also report on the performance of the PIXIE bolometers in a dark cryogenic environment.

PIXIE↗

Micromechanical Devices for Control of Cell-Cell Interaction, and Methods of Use Thereof

The development and function of living tissues depends largely on interactions between cells that can vary in both time and space; however, temporal control of cell-cell interaction is experimentally challenging. By employing a micromachined silicon substrate with moving parts, herein is disclosed the dynamic regulation of cell-cell interactions via direct manipulation of adherent cells with micron-scale precision. The inventive devices and methods allow mechanical control of both tissue composition and spatial organization. The inventive device and methods enable the investigation of dynamic cell-cell interaction in a multitude of applications, such as intercellular communication, spanning embryogenesis, homeostasis, and pathogenic processes.

Bhatia, Sangeeta N.↗

Diagnostic Techniques to Elucidate the Aerodynamic Performance of Acoustic Liners

In support of Topic A.2.8 of NASA NRA NNH10ZEA001N, the University of Florida (UF) has investigated the use of flow field optical diagnostic and micromachined sensor-based techniques for assessing the wall shear stress on an acoustic liner. Stereoscopic particle image velocimetry (sPIV) was used to study the velocity field over a liner in the Grazing Flow Impedance Duct (GFID). The results indicate that the use of a control volume based method to determine the wall shear stress is prone to significant error. The skin friction over the liner as measured using velocity curve fitting techniques was shown to be locally reduced behind an orifice, relative to the hard wall case in a streamwise plane centered on the orifice. The capacitive wall shear stress sensor exhibited a linear response for a range of shear stresses over a hard wall. PIV over the liner is consistent with lifting of the near wall turbulent structure as it passes over an orifice, followed by a region of low wall shear stress.

June, Jason↗

Ion Chromatography-on-a-chip for Water Quality Analysis

We report progress towards developing a Micro-Electro-Mechanical Systems (MEMS)- based ion chromatograph (IC) for crewed spacecraft water analysis. This IC-chip is an offshoot of a NASA-funded effort to produce a high performance liquid chromatograph (HPLC)-chip. This HPLC-chip system would require a desalting (i.e. ion chromatography) step. The complete HPLC instrument consists of the Jet Propulsion Labortory's (JPL's) quadrupole ion trap mass spectrometer integrated with a state-of-the-art MEMS liquid chromatograph (LC) system developed by the California Institute of Technology's (Caltech's) Micromachining Laboratory. The IC version of the chip consist of an electrolysis-based injector, a separation column, two electrolysis pumps for gradient generation, mixer, and a built-in conductivity detector. The HPLC version of the chip also includes a nanospray tip. The low instrument mass, coupled with its high analytical capabilities, makes the LC chip ideally suitable for wide range of applications such as trace contaminant, inorganic analytical science and, when coupled to a mass spectrometer, a macromolecular detection system for either crewed space exploration vehicles or robotic planetary missions.

Kidd, R. D.↗

Far-Infrared Room-Temperature Focal Plane Modules for Radiation Budget Instrument

This work presents focal plane modules for a Radiation Budget Instrument, a passive remote-sensing instrument that follows the legacy of the Clouds and Earth’s Radiant Energy System (CERES) to measure short and longwave Earth’s radiation budget. The focal plane arrays are micromachined at JPL (Jet Propulsion Laboratory) and integrated into sub-assembly modules to be mounted on the optical telescope of the instrument.

Mariani, Giacomo↗

Small Inertial Measurement Units- Sources of Error and Limitations on Accuracy

Inertial measurement units (IMUs) with very low mass and power can be manufactured using micromachined accelerometers and gyroscopes. Six degree of freedom packages which require a few watts of power and have less than a kg of mass are available commercially, greatly expanding the potential applications of IMUs in guidance and navigation. Recent advances in small sensor design and fabrication have pushed the performance limits of these small devices. However, the limitations on the precision of small IMUs are not entirely due to the performance of the individual sensors.

Hoenk, Michael E.↗

Characterizing Deformable Mirrors for the MagAO-X Instrument

The MagAO-X instrument is a new extreme adaptive optics system for high-contrast imaging at visibleand near-infrared wavelengths on the Magellan Clay Telescope. A central component of this system is a 2040-actuatormicroelectromechanical deformable mirror (DM) from Boston Micromachines Corp. that operates at 3.63 kHz forhigh-order wavefront control (the tweeter). Two additional DMs from ALPAO perform the low-order (the woofer)and non-common-path science-arm wavefront correction (the NCPC DM). Prior to integration with the instrument, wecharacterized these devices using a Zygo Verifire Interferometer to measure each DM surface. We present the resultsof the characterization effort here, demonstrating the ability to drive tweeter to a flat of 6.9 nm RMS surface (and 0.56nm RMS surface within its control bandwidth), the woofer to 2.2 nm root mean square (RMS) surface, and the NCPCDM to 2.1 nm RMS surface over the MagAO-X beam footprint on each device. Using focus-diversity phase retrievalon the MagAO-X science cameras to estimate the internal instrument wavefront error (WFE), we further show that theintegrated DMs correct the instrument WFE to 18.7 nm RMS, which, combined with a 11.7% pupil amplitude RMS,produces a Strehl ratio of 0.94 at H↵

Kyle Van Gorkom↗

Far-infrared room-temperature focal plane modules for polar radiant energy in the Far InfraRed experiment

This work presents focal plane modules for Polar Radiant Energy in the Far InfraRed Experiment, a passive remote-sensing instrument aimed to determine errors in the estimated outgoing longwave radiation in the Earth’s polar regions to reduce uncertainties in surface emissivity, mass balance, and ice flux. The focal plane arrays are micromachined at JPL and integrated into sub-assembly modules to be mounted on the optical telescope of the instrument.

White, Mary↗

Antennas, Arrays, and Systems for Submillimter-Wave Radio Astronomy

In this paper we present the design and development of a 16-pixel submillimeter-wave array instrument using SIS technology. We show that this instrument concept demonstration and component development dramatically simplifies the fabrication, assembly, and integration of large focal plane arrays at these frequencies. This advancement is enabled by the innovative array architecture with silicon microlens based antenna arrays, highly sensitive SIS mixers at these frequencies, integrated SiGe BiCMOS based low-noise intermediate frequency (IF) amplifiers, and silicon micromachined packaging.

Chattopadhyay, Goutam↗

Integrated Silicon Platform for Co-planar Design of Vertically Stacked 2.06 THz Mixer Module

The process for fabricating and utilizing the threedimensional Si stack receiver front-end is described in this paper. The capability to have exact dimensionality becomes essential as frequency scales due to the complexity arising in assembly and finer tolerances. Total process yields can be improved through Si fabrication by verifying achievement of specified tolerances lithographically and compatibility to rapid process changes and design fine-tuning. The integrated Si platform with the mounted device is shown in Figure 1. Signal I/O and alignment modalities enable lownoise measurements. Silicon micromachining provides the necessary accuracy for integration at the several THz regime. Particularly, processing and etch recipes have demonstrated smooth surfaces of < 1 μm surface roughness. In consideration is pre-compensating for minute offsets, matching mechanical strain on all interfaces, and including passive alignment verification in the design. As compared to metal blocks, computer numerical controlled (CNC) milling can produce slight burrs in the interfaces resulting in misalignment and resultant strain between two pieces of components. Furthermore, Si integration can make possible arrays of pixel transceivers through compact subsystems for the purpose of measuring multiple lines of spectral content simultaneously in space.

Mehdi, Imran↗

Laboratory Demonstration of High Contrast with the PIAACMC Coronagraph on an Obstructed and Segmented Aperture

Coronagraphs (together with starshades) are an important tool to directly image and characterize exoplanets, and enable the search for biomarkers in reflected light on potentially habitable worlds. Their performance and efficiency has steadily been improving over the past several decades, but has not yet reached performance limits. In particular, the expected exoplanet yield for missions such as the Astro2020-recommended “IR/O/UV Flagship” can still be improved by factors of at least 2-3, simply by continued improvements in coronagraph performance, before they plateau due to physics limits. One possible architecture that can enable at least a part of this improvement is the Phase-Induced Amplitude Apodization Complex Mask Coronagraph (PIAACMC). Itoffersthe advantages of high throughput, small inner working angle (IWA),and almost noloss inPSF sharpness, and natively supports obstructed and segmented apertures, which is essential to the Astro2020 “IR/O/UV Flagship”mission. Historically, key disadvantages of PIAA have been poor tolerance to stellar angular sizes and maturity, but latest designs and demonstrations have made significant strides in this respect.In this paper, we present the current status and overview of our program to mature the PIAACMC technology. We first review PIAACMC designs for LUVOIR-A and B, which resultedin improved expected yield of Exo-Earths relative tothe baselines for both mission concepts. In particular, for LUVOIR-B, the yield improves from 28 to 42due to improvedtolerance to stellar angular size in our design. The improvement in yield is marginal for LUVOIR-A, but our design enables detecting planets around smaller diameter stars (nearby K-dwarfs and/or farther FG stars). We also describe our modeling and vacuum demonstrationsfor the LUVOIR-A aperture(which is more challengingthan LUVOIR-B due to the central obstruction).The demonstration included a LUVOUR-A pupil mask, an on-axis PIAA set of 2 mirrors with central holes, a Boston Micromachines DM, a patterned CMC mask, Lyot stop, and supporting masks and optics. Demonstrations were conducted at JPL’s High Contrast Imaging Testbed (HCIT) using several characterization andwavefront control techniques (primarily standard EFC, several experimental techniques were attempted, as well as speckle nulling). So far, our results include 1.9e-8 raw contrast in 10% broadband light between 3.5 and 8 l/D; 4.1e-8 and 1.6e-9 coherent contrasts in monochromatic light between 2-4 and 4-8 l/D, respectively. We also present measurements and analysis of sensitivity to tip/tilt jitter and stellar angular size. Finally, we compare our test results to models, present an analysis of our limiting factors, and explorefuture prospectsfor improvement based on validated models.

Coronagraph↗

Technology Developments for FIR Bolometric Detector Focal Plane Assemblies

A discussion of recent technology developments for far-infrared bolometric detector focal plane assemblies is provided. Some of the developments include strategies for fabricating high filling fraction background limited-transition edge sensor bolometric detectors, impedance-matched absorber coatings, a micromachined blackbody source, and the capability to fabricate indium bumps on non-planar substrates.

Detectors↗

High Contrast Imaging With MEMS Deformable Mirrors in the Decadal Survey Testbed

Deformable mirrors (DMs) are an essential part of any coronagraphic, high contrast instrument. They mitigate optical aberrations in the system and can even be used to generate contrast for the coronagraph. MEMS DMs from Boston Micromachines have been selected as the baseline for two flagship space telescopes proposed to the 2020 Decadal Survey. Although MEMS DMs have over a decade of heritage on ground-based telescopes and in in-air testbeds around the globe, they have not been tested in vacuum down to the ∼10−10 contrast level needed to image terrestrial exoplanets. In this paper, we describe vacuum tests of MEMS DMs in the Decadal Survey Testbed at the Jet Propulsion Laboratory. The first challenge was a bright, temporally incoherent signal, which was identified as electronics noise and removed with a low-pass filter. After that, the contrast has been limited in broadband light by the strong print-through on the DM surfaces. We performed numerical simulations to confirm that conclusion and to characterize the improvements needed to the MEMS DM surfaces and the testbed layout to attain our goal of 10−10 contrast.

Seo, Byoung-Joon↗

Design and Commissioning of an In-Air Coronagraph Testbed in the HCIT facility at NASA’s Jet Propulsion Laboratory

After completing its duty in the vacuum chamber at the High Contrast Imaging Testbed (HCIT) facility at NASA’s Jet Propulsion Laboratory, the General Purpose Coronagraph Testbed (GPCT) has been retrofitted as the In-Air Coronagraph Testbed (IACT), with the purpose of verification of Boston Micromachines (BMC) 50x50 MEMS deformable mirrors (MEMS DM) performance by contrast comparison before and after random vibration testing. The testbed is configured as a vortex coronagraph, with one MEMS DM in the pupil plane to create a half dark hole in monochromatic light. High wavefront stability is achieved using an environmentally isolating enclosure, based on the enclosure design previously used on Caltech’s High Contrast Spectroscopy Testbed (HCST). Further, a smaller enclosure has been designed which will enforce humidity conditions necessary for the MEMS DM to operate. We expect this testbed to achieve 1e-8 contrast, and will use this contrast level as a baseline to assess survival or failure of MEMS DMs during vibration testing. In this presentation, we will present an overview of the design of the IACT, commissioning results, and plans for upcoming DM tests in preparation for launch on future space telescopes with coronagraph instruments.

Mejia-Prada, Camilo↗

Exep: Environmental Testing of High-Actuator-Count Mems Deformable Mirrors for Space-Based Applications

Coronagraph instruments on future space telescopes will rely on deformable mirrors to create high contrast images for the direct detection of exoplanets. As part of the NASA Exoplanet Explorations Program’s coronagraph technology development efforts, two sets of Micro-electro-mechanical systems (MEMS) deformable mirrors manufactured by Boston Micromachines Corporation were exposed to vibration and thermal cycles representative of launch conditions. The first set were 952-actuator Kilo-DMs that successfully demonstrated 100% actuator survival and achieved ~1e-8 contrast after the environment test. The second round used an engineering-grade 2048-actuator deformable mirror on which few changes were identified after the environmental test. However, each actuator that changed behavior was flagged as anomalous beforehand or was directly adjacent to a defective actuator. From this result, we hypothesized that typical actuators on a science grade deformable mirror are robust to environmental testing. A third set of 2048-actuator deformable mirror have been procured for a planned test to characterize the deformable mirrors using interferometric measurements, contrast results on a new in-air coronagraph testbed, and infrared microscopy on the internal structure of the MEMS devices.

Lam, Charlie↗