Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Medical Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Using 3D Measurements from MRI to Improve VVUQ

Magnetic resonance velocimetry (MRV) is a diagnostic that can measure 3D, three-component turbulent velocity fields in arbitrarily complex flow configurations. The approach uses magnetic resonance imaging (MRI), which is a system commonly available in radiology departments or medical research centers. MRV acquires signal from hydrogen protons in water channel flows. Despite the obvious utility of the measurements for investigating a variety of flows, comparisons with computational fluid dynamic (CFD) simulations largely retain traditional metrics, comparing velocity profiles and planes at discrete regions within the flow rather than using the 3D nature of the measured field. In this effort, MRV was conducted in a simple water channel with six spanwise-centered periodic obstacles roughly shaped as cubes. At a fully turbulent Reynolds number of 15,000, the channel includes two flows: a main streamwise flow and, in the wake of the second obstacle, an injected flow oriented perpendicular to the streamwise flow. The flow geometry includes partial obstacles on the side walls and is inherently 3D because of the interaction of the two streams and the wake features, making the flow challenging to completely measure with traditional optical techniques. Aside from line profiles and planar comparisons, two 3D metrics are used to compare the data with a steady Reynolds-averaged Navier–Stokes (RANS) simulation result. A brief discussion about the comparison is provided, including comments about uncertainty.

Benson, Mike [ORNL] (ORCID:000000023210116X)↗

Microtron Data Log

The Microtron at Los Alamos National Laboratory (LANL) is a versatile electron accelerator originally designed for medical therapy. Since 2001, it has been used for non-destructive radiographic imaging and research and development applications. Operating at four different energy levels—6, 10, 15, and 20 MeV—the Microtron produces dose rates of approximately 780, 1800, 2700, and 2800 R/min at a distance of one meter from the source, respectively. This high-energy X-ray source enables detailed internal examination of dense and thick objects without causing damage, making it invaluable for various scientific and industrial applications. For instance, LANL’s Microtron has been utilized to study the performance of large-panel cerium-doped lutetium yttrium silicon oxide (LYSO) scintillators, which are essential components in advanced imaging systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of the laser welding keyhole using inline coherent imaging

Laser beam welding is a widely used fusion welding process in many industrial applications such as automotive, aerospace, energy, defense, and medical products. Industry has a fundamental need to model the laser welding process to minimize experimental testing and improve confidence in production welds. However, computational models attempting to predict weld formation are limited by an incomplete understanding of the beam-material interactions. As a consequence, these models do not accurately predict the mechanisms associated with laser weld formation. To improve the current state of prediction capabilities, it is vital to better detect/measure the physical aspects of the weld pool during high energy density welding. In this work, a novel real-time laser weld monitoring device using inline coherent imaging (ICI) was used to provide a fundamental understanding of laser weld formation via vaporization. The objective of this work was to investigate and quantify the relationship relating laser weld parameters and the vapor capillary (keyhole) through a state-of-the-art measurement technique. Bead-on-plate laser beam welds were produced with partial penetration on 304L stainless steel, 2205 duplex stainless steel, and Ti-6Al-4V. Keyhole monitoring was performed using a commercially available ICI system to collect keyhole penetration data in real time. These measurements were reconstructed to generate the vapor capillary shape at different welding parameters. Process parameters significantly influenced the keyhole shape and the keyhole root position relative to the process beam. Finally, the keyhole geometry showed distinct differences between the stainless steel alloys and Ti-6Al-4V.

2205↗

Anion exchange and extraction chromatography tandem column isolation of zirconium-89 ( 89 Zr) from cyclotron bombarded targets using an automated fluidic platform

The long-lived positron emitter 89 Zr is a highly promising nuclide employed in diagnostic Positron Emission Tomography (PET) imaging. Methods of radiochemical processing to obtain 89 Zr for clinical use are traditionally performed with a single hydroxamate resin column. In this work, we present a tandem column purification method for the preparation of high-purity 89 Zr from cyclotron bombarded Y metal foils. The primary column is a macroporous, strongly basic anion exchange resin on styrene divinylbenzene co-polymer. The secondary microcolumn, with an internal volume of 33 µL, is packed with an extraction chromatography resin (ExCR) loaded with HDEHP. A condition of “inverted selectivity” is presented, wherein the 89 Zr elution from the primary column is synonymous with the load condition on the secondary column. The ability to transfer 89 Zr from one column to the next allows two sequential column clean-up methods to be performed prior to the final elution of the 89 Zr product. This approach assures delivery of very high purity 89 Zr . The tandem column purification process has been implemented into a prototype automated fluidic system. Optimization of the method is presented, followed by evaluation of the process using seven cyclotron bombarded Y metal foil targets. Once optimized, we found that 93.7±2.3% of the 89 Zr present in the foils was recovered in the secondary column elution fraction (0.8 M oxalic acid). Radiochromatograms of the product elution peaks enabled determination of full width at half-maximum (FWHM) and 89 Zr collection yields as a function of volume. Because of the small size of the secondary microcolumn, a 89 Zr product volume of ~0.28 mL is reported, which provides a substantially increased nuclide concentration over traditional methods. Finally, we evaluated the transchelation of the resulting 89 Zr oxalate product to deferoxamine mesylate (DFOM) salt. We observed effective specific activities (ESA) and bindable metals concentrations ([M B ]) that exceed those reported by the traditional single hydroxamate column method.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Laser-driven x-ray and proton micro-source and application to simultaneous single-shot bi-modal radiographic imaging

Radiographic imaging with x-rays and protons is an omnipresent tool in basic research and applications in industry, material science and medical diagnostics. The information contained in both modalities can often be valuable in principle, but difficult to access simultaneously. Laser-driven solid-density plasma-sources deliver both kinds of radiation, but mostly single modalities have been explored for applications. Their potential for bi-modal radiographic imaging has never been fully realized, due to problems in generating appropriate sources and separating image modalities. Here, we report on the generation of proton and x-ray micro-sources in laser-plasma interactions of the focused Texas Petawatt laser with solid-density, micrometer-sized tungsten needles. We apply them for bi-modal radiographic imaging of biological and technological objects in a single laser shot. Thereby, advantages of laser-driven sources could be enriched beyond their small footprint by embracing their additional unique properties, including the spectral bandwidth, small source size and multi-mode emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DNA-PAINT Imaging with Hydrogel Imprinting and Clearing

Hydrogel-embedding is a versatile technique in fluorescence microscopy, offering stabilization, optical clearing, and the physical expansion of biological specimens. DNA-PAINT is a super-resolution microscopy approach based on the diffusion and transient binding of fluorescently labeled oligos, but its feasibility in hydrogels has not yet been explored. In this study, we demonstrate that polyacrylamide hydrogels support sufficient diffusion for effective DNA-PAINT imaging. Using acrydite-anchored oligonucleotides imprinted from patterned DNA origami nanostructures and microtubule filaments in fixed cells, we find that hydrogel embedding preserves docking strand positioning at the nanoscale. Sample clearing via protease treatment had minor structural effects on the microtubule structure and enhanced diffusion and accessibility to hydrogel-imprinted docking strands. Our work demonstrates promising potential for diffusion and binding-based fluorescence imaging applications in hydrogel-embedded samples.

DNA origami↗

Cancer Treatment-Associated Pericardial Disease: Epidemiology, Clinical Presentation, Diagnosis, and Management

Purpose of Review: Cancer therapeutics have seen tremendous growth in the last decade and have been effective in the treatment of several cancer types. However, with advanced therapies like kinase inhibitors and immunotherapies, there have been unintended consequences of cardiotoxicities. While traditional chemotherapy and radiation-induced cardiotoxicity have been well studied, further research is needed to understand the adverse effects of newer regimens. Recent Findings: Both immune-mediated and non-immune-medicated cytotoxicity have been noted with targeted therapies such as tyrosine kinase inhibitors and immune checkpoint inhibitors. In this manuscript, we describe the pericardial syndromes associated with cancer therapies and propose management strategies. Pericardial effusion and pericarditis are common presentations in cancer patients and often difficult to diagnose. Concomitant myocarditis may also present with pericardial toxicity, especially with immunotherapies. In addition to proper history and physical, additional testing such as cardiovascular imaging and tissue histology need to be obtained as appropriate. Holding the offending oncology drug, and institution of anti-inflammatory medications, and immunosuppressants such as steroids are indicated. Summary: A high index of suspicion, use of standardized definitions, and comprehensive evaluation are needed for early identification, appropriate treatment, and better outcomes for patients with cancer treatment-associated pericardial disease. Further research is needed to understand the pathophysiology and to evaluate how the management of pericardial conditions in these patients differ from traditional management and also evaluate new therapies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Review of Doses for Dental Imaging in 2010–2020 and Development of a Web Dose Calculator

Dental imaging is one of the most common types of diagnostic radiological procedures in modern medicine. We introduce a comprehensive table of organ doses received by patients in dental imaging procedures extracted from literature and a new web application to visualize the summarized dose information. We analyzed articles, published after 2010, from PubMed on organ and effective doses delivered by dental imaging procedures, including intraoral radiography, panoramic radiography, and cone-beam computed tomography (CBCT), and summarized doses by dosimetry method, machine model, patient age, and technical parameters. Mean effective doses delivered by intraoral, 1.32 (0.60–2.56) μSv, and panoramic, 17.93 (3.47–75.00) μSv, procedures were found to be about1% and 15% of that delivered by CBCT, 121.09 (17.10–392.20) μSv, respectively. In CBCT imaging, child phantoms received about 29% more effective dose than the adult phantoms received. The effective dose of a large field of view (FOV) (>150 cm2) was about 1.6 times greater than that of a small FOV (<50 cm2). The maximum CBCT effective dose with a large FOV for children, 392.2 μSv, was about 13% of theeffective dose that a person receives on average every year from natural radiation, 3110 μSv. Monte Carlo simulations of representative cases of the three dental imaging procedures were then conducted to estimate and visualize the dose distribution within the head. The user-friendly interactive web application (available at http://dentaldose.org) receives user input, such as the number of intraoral radiographs taken, and displays total organ and effective doses, dose distribution maps, and a comparison with other medical and natural sources of radiation. The web dose calculator provides a practical resource for patients interested in understanding the radiation doses delivered by dental imaging procedures.

Lee, Hawon↗

Coupling a recurrent neural network to SPAD TCSPC systems for real-time fluorescence lifetime imaging

Fluorescence lifetime imaging (FLI) has been receiving increased attention in recent years as a powerful diagnostic technique in biological and medical research. However, existing FLI systems often suffer from a tradeoff between processing speed, accuracy, and robustness. Inspired by the concept of Edge Artificial Intelligence (Edge AI), we propose a robust approach that enables fast FLI with no degradation of accuracy. This approach couples a recurrent neural network (RNN), which is trained to estimate the fluorescence lifetime directly from raw timestamps without building histograms, to SPAD TCSPC systems, thereby drastically reducing transfer data volumes and hardware resource utilization, and enabling real-time FLI acquisition. We train two variants of the RNN on a synthetic dataset and compare the results to those obtained using center-of-mass method (CMM) and least squares fitting (LS fitting). Results demonstrate that two RNN variants, gated recurrent unit (GRU) and long short-term memory (LSTM), are comparable to CMM and LS fitting in terms of accuracy, while outperforming them in the presence of background noise by a large margin. To explore the ultimate limits of the approach, we derive the Cramer-Rao lower bound of the measurement, showing that RNN yields lifetime estimations with near-optimal precision. To demonstrate real-time operation, we build a FLI microscope based on an existing SPAD TCSPC system comprising a 32 x 32 SPAD sensor named Piccolo. Four quantized GRU cores, capable of processing up to 4 million photons per second, are deployed on the Xilinx Kintex-7 FPGA that controls the Piccolo. Powered by the GRU, the FLI setup can retrieve real-time fluorescence lifetime images at up to 10 frames per second. The proposed FLI system is promising and ideally suited for biomedical applications, including biological imaging, biomedical diagnostics, and fluorescence-assisted surgery, etc.

47 OTHER INSTRUMENTATION↗

Domestic Supply Chain of Medical Consumables Needed During COVID-19 Pandemic

This report is an assessment of the availability, demand, and production capability of medical consumables needed to combat the COVID-19 pandemic. We focus here on the ability of the supply chain to increase production to meet demand during peak pandemic conditions. In addition, we report on domestic production efforts and supply chain issues, as well as the propensity of other countries to limit export of needed medical supplies to the United States. In brief, the domestic supply chain and production capability vary greatly depending on the consumable. Some consumables, such as N95 masks or face shields, can likely be nearly fully supplied by domestic production, while other consumables, such as gloves or surgical masks, have little domestic production and thus will depend on imports to meet demand. The assessment pulls primarily from published news sources and company press releases. As such, the demand and production numbers are not precisely known, and some degree of uncertainty exists in them. The total production capability is also often difficult to ascertain from these reports especially as other industries have begun to supplement existing supply chains. In addition, local conditions (including company financial decisions, local public health issues, and political aspects) can vary throughout the pandemic which will affect future production. The report also pulls from estimates of demand and domestic production of some consumables compiled by the White House COVID-19 Supply Chain Taskforce (SCTF) presented by Rear Admiral John Polowczyk before a June 9, 2020 hearing of the Senate Homeland Security and Governmental Affairs Committee. These numbers, where applicable, are likely to be more accurate than those found in public news sources since they are more directly tied to private companies’ actual orders and actual production estimates, as opposed to publicly released estimates. Finally, we note that other issues with the supply chain, including the production of raw materials, increase demand due to industries that have not previously used PPE now using it, and increased domestic production from non-traditional suppliers, make complete picture of a rapidly changing supply chain difficult to obtain. This report attempts to produce an accurate image of the supply and estimated demand, as understood by the authors who are not experts in the medical supply chain.

42 ENGINEERING↗

Specific absorbed fractions for a revised series of the UF/NCI pediatric reference phantoms: internal photon sources

Assessment of radiation absorbed dose to internal organs of the body from the intake of radionuclides, or in the medical setting through the injection of radiopharmaceuticals, is generally performed based upon reference biokinetic models or patient imaging data, respectively. Biokinetic models estimate the time course of activity localized to source organs. The time-integration of these organ activity profiles are then scaled by the radionuclide S-value, which defines the absorbed dose to a target tissue per nuclear transformation in various source tissues. S-values are computed using established nuclear decay information (particle energies and yields), and a parameter termed the specific absorbed fraction (SAF). The SAF is the ratio of the absorbed fraction—fraction of particle energy emitted in the source tissue that is deposited in the target tissue—and the target organ mass. While values of the SAF may be computed using patient-specific or individual-specific anatomic models, they have been more widely available through the use of computational reference phantoms. In this study, we report on an extensive series of photon SAFs computed in a revised series of the University of Florida and the National Cancer Institute pediatric reference phantoms which have been modified to conform to the specifications embodied in the ICRP reference adult phantoms of Publication 110 (e.g. organs modeled, organ ID numbers, blood contribution to elemental compositions). Following phantom anatomical revisions, photon radiation transport simulations were performed using MCNPX v2.7 in each of the ten phantoms of the series—male and female newborn, 1 year old, 5 year old, 10 year old, and 15 year old—for 60 different tissues serving as source and/or target regions. A total of 25 photon energies were considered from 10 keV to 10 MeV along a logarithm energy grid. Detailed analyses were conducted of the relative statistical errors in the Monte Carlo target tissue energy deposition tallies at low photon energies and over all energies for source–target combinations at large intra-organ separation distances. Based on these analyses, various data smoothing algorithms were employed, including multi-point weighted data smoothing, and log–log interpolation at low energies (1 keV and 5 keV) using limiting SAF values based upon target organ mass to bound the interpolation interval. The final dataset is provided in a series of ten electronic supplemental files in MS Excel format. Finally, the results of this study were further used as the basis for assessing the radiative component of internal electron source SAFs as described in our companion paper (Schwarz et al 2021) for this same pediatric phantom series.

61 RADIATION PROTECTION AND DOSIMETRY↗

Specific absorbed fractions for a revised series of the UF/NCI pediatric reference phantoms: internal electron sources

Assessment of radiation absorbed dose to internal organs of the body from the intake of radionuclides, or in the medical setting through the injection of radiopharmaceuticals, is generally performed based upon reference biokinetic models or patient imaging data, respectively. Biokinetic models estimate the time course of activity localized to source organs. The time-integration of these organ activity profiles are then scaled by the radionuclide S-value, which defines the absorbed dose to a target tissue per nuclear transformation in various source tissues. S-values are computed using established nuclear decay information (particle energies and yields), and a parameter termed the specific absorbed fraction (SAF). The SAF is the ratio of the absorbed fraction—fraction of particle energy emitted in the source tissue that is deposited in the target tissue—and the target organ mass. While values of the SAF may be computed using patient-specific or individual-specific anatomic models, they have been more widely available through the use of computational reference phantoms. In this study, we report on an extensive series of photon SAFs computed in a revised series of the University of Florida and the National Cancer Institute pediatric reference phantoms which have been modified to conform to the specifications embodied in the ICRP reference adult phantoms of Publication 110 (e.g. organs modeled, organ ID numbers, blood contribution to elemental compositions). Following phantom anatomical revisions, photon radiation transport simulations were performed using MCNPX v2.7 in each of the ten phantoms of the series—male and female newborn, 1 year old, 5 year old, 10 year old, and 15 year old—for 60 different tissues serving as source and/or target regions. A total of 25 photon energies were considered from 10 keV to 10 MeV along a logarithm energy grid. Detailed analyses were conducted of the relative statistical errors in the Monte Carlo target tissue energy deposition tallies at low photon energies and over all energies for source–target combinations at large intra-organ separation distances. Based on these analyses, various data smoothing algorithms were employed, including multi-point weighted data smoothing, and log–log interpolation at low energies (1 keV and 5 keV) using limiting SAF values based upon target organ mass to bound the interpolation interval. The final dataset is provided in a series of ten electronic supplemental files in MS Excel format. Finally, the results of this study were further used as the basis for assessing the radiative component of internal electron source SAFs as described in our companion paper (Schwarz et al 2021) for this same pediatric phantom series.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Relativistic Laser Plasma Interactions At The Highest Intensities

High energy density science (HEDS) explores the nature of matter under extreme conditions of temperature and pressure. It is of fundamental importance and has many applications such as facilitating imaging with ions, neutrons, x-rays, and gamma rays with new applications being developed, including materials processing and medical therapies. In this project, we used high power, ultrashort pulse lasers to reach HEDS conditions. We have shown that low-cost, liquid crystal film based, double plasma mirror systems can be used to greatly improve laser pulse contrast while still maintaining high power and excellent spatial mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Field-Deployable Magnetic Resonance Imaging Rhizotron for Modeling and Enhancing Root Growth and Biogeochemical Function

A collaborative team from Texas A&M AgriLife Research, ABQMR Inc., the Soil Health Institute, the Athinoula A. Martinos Center for Biomedical Imaging, and NIST developed low-field magnetic resonance imaging (LF-MRI) instrumentation capable of imaging intact soil-root systems. The system measured root biomass, architecture, 3D mass distribution, and growth rates, providing a non-destructive means to evaluate ideal plant characteristics based on root metrics. It also successfully generated three-dimensional images of soil water content, a key property influencing root growth and exploration. Operating much like an MRI used in a medical setting, the system functioned in field conditions without damaging plants, overcoming the limitations of traditional methods such as trenching, soil coring, and root excavation. Over the course of the project, the team designed and built three functional prototype systems. These prototypes provided new insights into root–water–soil interactions that drive processes such as nutrient uptake, water use, and carbon management. This information contributed to efforts to optimize plants for carbon sequestration without sacrificing economic yield. The project also supported the identification of desirable traits for energy sorghum, including high root growth rates, more vertical root angles, and enhanced drought resilience under water-limiting conditions.

09 BIOMASS FUELS↗

Relativistic plasma effects and ion acceleration using Scarlet and ELI-NP

High energy density science (HEDS) explores the nature of matter under extreme conditions of temperature and pressure. It has wide ranging fundamental importance from understanding the physical structure of our planet to extreme phenomena in the cosmos. It also has many applications such as facilitating imaging with ions, neutrons, x-rays, gamma rays and more with new applications being developed, including materials processing and medical therapies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Attention-based 3D – convolutional neural network model for mechanical property predictions using visible light images in metal additive manufacturing

Additive manufacturing (AM), while commonly used for rapid prototyping and creating components with complex geometries, has not been widely adopted for critical applications across the aerospace, automotive, defense, energy, and medical industries. This is, in part, due to the challenges of controlling flaws and uncertainty in the mechanical behavior of additively manufactured components. In recent years, there has been an increase in research aimed at predicting the final mechanical properties of additively manufactured components during the printing process. To address these issues, a 3D-CNN model was trained using low-cost in situ visible-light camera data, anomaly classifications, and the chosen process parameters to predict the ultimate tensile strength (UTS), yield strength (YS), total elongation (TE), and uniform elongation (UE). The 3D-CNN layers of the model employed attention mechanisms to prioritize features in the data, thereby improving prediction accuracy. Furthermore, the effect of each process parameter and anomaly class is investigated using attention-based dynamic sigmoid weighted gates to interpret the influence each class has on the final prediction. Different combinations of the in situ data were fed into the 3D-CNN, with varying amounts of image layers, to determine the ideal combination for predicting mechanical properties in situ. Here, the 3D-CNN model achieved mean absolute percentage errors (MAPE) below 5% for both UTS and YS while using only a single camera input and under half of the available image layers.

36 MATERIALS SCIENCE↗

Transfer Learning using Denoising Auto-Encoders for Cellular-Level Annotation of Tumor in Pathology Slides

Adversarial examples can produce altered classifications using only seemingly innocuous, imperceptible perturbations to the original image. The imperceptibility of adversarial perturbations suggests that the corresponding classifiers use decision criteria different than those of a human. In a medical setting, inexplicable decision criteria confound a pathologist’s willingness to trust machine-generated annotations. Here, we analyze denoising tumor detection models to see if they are robust to imperceptible adversarial perturbations. Moreover, to be more fully trusted by pathologists, we require tumor detectors that generate interpretable annotations which segment pathology slides into tumorous and normal regions at the cellular level. We therefore compare transfer learning based on two different autoencoder architectures, one derived from a deep denoising bottleneck autoencoder and one from an over-complete sparse autoencoder. Both autoencoders were first trained in an unsupervised manner on a set of pathology slides drawn from the Camelyon16 dataset. The latent representations produced by each autoencoder were then passed to separate neural networks that were trained in a supervised manner on binary tumor-normal masks generated by pathologists at cellular resolution. Both tumor detectors supported better than 90% AUC PR as measured by the area under the precision/recall curve on a held-out pathology slide. To assess the underlying decision criteria used by both tumor detectors, we constructed imperceptible adversarial examples which reduced the AUC PR of both models to less than 70%. Random noise of the same amplitude had almost no effect on the AUC PR of either model. Additionally, each tumor detector was resistant to adversarial “transfer” attacks targeting the other. The adversarial perturbations showed strong characteristic differences: the deep denoising models perturbations were a very diffuse, seemingly unrecognizable pattern while the sparse coding models perturbations showed traces of tissue cells.

47 OTHER INSTRUMENTATION↗