Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Characterizing the Number of Kinesin Motors Bound to Microtubules in the Gliding Motility Assay Using FLIC Microscopy [Book Chapter]

Intracellular transport by kinesin motors moving along their associated cytoskeletal filaments, microtubules, is essential to many biological processes. This active transport system can be reconstituted in vitro with the surface-adhered motors transporting the microtubules across a planar surface. In this geometry, the kinesin-microtubule system has been used to study active self-assembly, to power microdevices, and to perform analyte detection. Fundamental to these applications is the ability to characterize the interactions between the surface tethered motors and microtubules. Further, Fluorescence Interference Contrast (FLIC) microscopy can illuminate the height of the microtubule above a surface, which, at sufficiently low surface densities of kinesin, also reveals the number, locations, and dynamics of the bound motors.

59 BASIC BIOLOGICAL SCIENCES↗

Analytical methods for superresolution dislocation identification in dark-field X-ray microscopy

In this work, we develop several inference methods to estimate the position of dislocations from images generated using dark-field X-ray microscopy (DFXM)—achieving superresolution accuracy and principled uncertainty quantification. Using the framework of Bayesian inference, we incorporate models of the DFXM contrast mechanism and detector measurement noise, along with initial position estimates, into a statistical model coupling DFXM images with the dislocation position of interest. We motivate several position estimation and uncertainty quantification algorithms based on this model. We then demonstrate the accuracy of our primary estimation algorithm on synthetic realistic DFXM images of edge dislocations in single-crystal aluminum. We conclude with a discussion of our methods’ impact on future dislocation studies and possible future research avenues.

36 MATERIALS SCIENCE↗

Characterization of Two Fast-Turnaround Dry Dilution Refrigerators for Scanning Probe Microscopy

Low-temperature scanning probe microscopes (SPMs) are critical for the study of quantum materials and quantum information science. Due to the rising costs of helium, cryogen-free cryostats have become increasingly desirable. However, they typically suffer from comparatively worse vibrations than cryogen-based systems, necessitating the understanding and mitigation of vibrations for SPM applications. Here, in this work, we demonstrate the construction of two cryogen-free dilution refrigerator SPMs with minimal modifications to the factory default and we systematically characterize their vibrational performance. We measure the absolute vibrations at the microscope stage with geophones and use both microwave impedance microscopy and a scanning single-electron transistor to independently measure tip-sample vibrations. Additionally, we implement customized filtering and thermal anchoring schemes and characterize the cooling power at the scanning stage and the tip electron temperature. This work serves as a reference to researchers interested in cryogen-free SPMs, as such characterization is not standardized in the literature or available from manufacturers.

36 MATERIALS SCIENCE↗

In-situ transmission electron microscopy investigation on surface oxides thermal stability of niobium

Niobium is commonly used for superconducting quantum systems as readout resonators, capacitors, and interconnects. Structural defects at the Nb/Si and air/Nb interface may be a major source of two-level systems (TLS), which are detrimental to the device's coherence time. Thus, identifying and understanding the microscopic origin of possible TLS in Nb-based devices and their relationship to processing is key to superconducting qubit performance improvement. Here this work studied the structure and thermal stability of surface oxide on physical vapor deposited Nb films on Si wafers, using aberration-corrected (scanning) transmission electron microscopy and spectroscopy. Here, all Nb films exhibit columnar growth with strong [110] textures. After in-situ heating of the heterostructure at 360 °C inside the microscope, the initial amorphous niobium surface oxides decompose into face-centered cubic Nb nanograins in the amorphous Nb-O matrix, which may reduce microwave dissipation. Despite changes in the microstructure and chemistry of the niobium oxide surface layer due to heat treatment, the interface between the Nb and the surface oxide layer remains almost unchanged. Our comprehensive study of the Nb surface oxide decomposition mechanism may guide future superconducting qubit device optimization through interfacial scattering center and TLS minimization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tracking the prelude of the electroreduction of carbon monoxide via its interaction with Cu(100): Studies by operando scanning tunneling microscopy and infrared spectroscopy

The first isolable intermediate in the electrochemical reduction of carbon dioxide is carbon monoxide. This species, or its hydrated form, formic acid, is also the primary end product from all but a handful of metallic electrodes; with the latter, hydrogen gas is generated, but it emanates from the reduction of water and not from CO 2 . Only one electrode material, zerovalent copper, can spawn, in greater-than-trace quantities, a variety of species that are more highly reduced than CO. Hence, if the aim is to pursue a reaction trail of the reduction of CO 2 to products other than CO, it would be both logical and expedient to track the electrocatalytic reaction of CO itself. Heterogeneous electrocatalysis is a surface phenomenon; it transpires only when the reactant, CO in this case, chemisorbs on, or chemically interacts with, the Cu electrode surface. There is no electrocatalytic reaction if there is no CO adsorption. In ultrahigh vacuum, no CO resides on the Cu(100) surface at temperatures higher than 200 K. However, under electrochemical conditions, CO is chemisorbed on Cu at ambient temperatures at a given potential. Here, we thus paired, in seriatim fashion, scanning tunneling microscopy (STM) and polarization-modulation IR reflection-absorption spectroscopy (PMIRS) to document the influence of applied potential on the coverage, the molecular orientation, and the adlattice structure of CO adsorbed on Cu(100) in alkaline solutions; the results are described in this paper.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Argon broad ion beam sectioning and high resolution scanning electron microscopy imaging of hydrated alite

Highlights: • The native fibrous outer and dense inner C-S-H structure are preserved by using low energy argon broad ion beam sectioning. • Possible artefacts of the preparation and imaging of hydrated alite are shown and discussed. • An approach for a semi automated pore analysis of the obtained high resolution images is demonstrated. Scanning electron microscopy (SEM) imaging is able to visualize micro- to nano-structures of cement and concrete. A prerequisite is that the sample preparation preserves the native structure of the specimen. In this study, argon broad ion beam (BIB) sectioning is compared to state-of-the-art sample preparation (resin embedding, polishing) for hydrated alite. Additionally, it is investigated if during BIB, sample cooling is beneficial to avoid deterioration of cement hydrates. The aim is to quantitatively measure pore size distributions in hardened alite pastes. Therefore, not only optimized sample preparation but also optimized imaging conditions are investigated. Finally, it is demonstrated that by image analysis pores down to a diameter of 5 nm in hydrated alite pastes can be quantitatively analysed.

36 MATERIALS SCIENCE↗

Three-dimensional traction microscopy accounting for cell-induced matrix degradation

Tractions exerted by cells on the extracellular matrix (ECM) are critical in many important physiological and pathological processes such as embryonic morphogenesis, wound healing, and cancer metastasis. Three-dimensional Traction Microscopy (3DTM) is a tool to quantify cellular tractions by first measuring the displacement field in the ECM in response to these tractions, and then using this measurement to infer tractions. Most applications of 3DTM have assumed that the ECM has spatially-uniform mechanical properties, but cells secrete enzymes that can locally degrade the ECM. In this work, a novel computational method is developed to quantify both cellular tractions and ECM degradation. In particular, the ECM is modeled as a hyperelastic, Neo-Hookean solid, whose material parameters are corrupted by a single degradation parameter. The feasibility of determining both the traction and the degradation parameter is first demonstrated by showing the existence and uniqueness of the solution. An inverse problem is then formulated to determine the nodal values of the traction vector and the degradation parameter, with the objective of minimizing the difference between a predicted and measured displacement field, under the constraint that the predicted displacement field satisfies the equation of equilibrium. The inverse problem is solved by means of a gradient-based optimization approach, and the gradient is computed efficiently using appropriately derived adjoint fields. The computational method is validated in-silico using a geometrically realistic neuronal cell model and synthetic traction and degradation fields. It is found that the method accurately recovers both the traction and degradation fields. Moreover, it is found that neglecting ECM degradation can yield significant errors in traction measurements. Finally, our method can extend the range of context where tractions can be appropriately measured.

42 ENGINEERING↗

Component Identification of Solid Biomass Fuels Using Reflected Light Microscopy: Interlaboratory Study 2

As nations transition toward sustainable energy systems, biomass has become a vital component of global energy portfolios. Derived from organic materials such as wood, agricultural residues, forestry byproducts, and organic waste, biomass is a renewable energy source with significant environmental and economic benefits. Responsible biomass energy production can improve waste management, reduce emissions of greenhouse gases, and mitigate environmental pollution. However, as the diversity of biomass-derived fuels increases, robust quality assessment methods are essential to ensure their efficiency, safety, and minimal environmental impact. Reflected light microscopy (RLM) is one such technique with the potential to complement conventional physico-chemical analyses by enabling a rapid identification of material constituents and impurities. To refine this methodology and evaluate the reproducibility of solid biomass component identification using RLM, an interlaboratory study (ILS) was conducted. The study involved the recognition of 58 components across 45 photomicrographs, with the participation of 65 scientists and students from 25 countries. The participants faced high difficulty identifying some of the marked components, and as a result, the percentage of correct answers ranged from 19.0 % to 98.3 %, with an average correct identification rate of 62.7 %. The most challenging aspects of the identification process included distinguishing between woody and non-woody (agro) biomass, accurately identifying petroleum-derived materials, and differentiating agro biomass from inorganic matter. The results suggest that while RLM is an important tool for characterizing solid biomass, further development of methodology guidelines and training are necessary to enhance its effectiveness. Future research should prioritize preparing detailed, image-rich, microscopic morphological descriptions of biomass fuel components, which could improve the accuracy and reliability of using RLM in biomass fuel characterization.

09 BIOMASS FUELS↗

Probing individual single atom electrocatalyst sites by advanced analytical scanning transmission electron microscopy

Single atom electrocatalysts (SAEs) are promising next-generation materials for promoting a variety of important reactions, such as the oxygen reduction, nitrogen reduction, and CO 2 reduction reactions. While bulk characterization techniques such as X-ray absorption spectroscopy and Mössbauer spectroscopy have significantly enhanced our understanding of these catalysts, direct probing of individual single metal atom sites at the atomic scale is necessary to understand local variations in the properties of these sites and accelerate design and synthesis of improved SAEs. Aberration-corrected scanning transmission electron microscopy (STEM) has become a powerful tool for providing this type of atomic-scale information about SAE metal sites. These sites are typically unstable under the electron beam, however, which, in combination with conventional acquisition methods and detectors, has limited the type and quantity of information obtainable by spectroscopic STEM techniques. Here, we map multiple individual SAE metal sites in a nitrogen-doped carbon containing atomically dispersed Fe and Re (FeReNC) at the atomic scale by direct electron detection electron energy-loss spectroscopy (EELS). Direct electron detection provides an improved signal-to-noise ratio over conventional scintillator-based detectors and enables detection and real space localization of weak signals. In addition, we demonstrate an automated method for identification of metal atom positions, placement of the probe on these sites, and simultaneous EELS and energy dispersive X-ray spectroscopic (EDS) signal acquisition. This simultaneous acquisition of EELS and EDS provides access to the composition and bonding of a wide range of SAE metal sites. In this study, focusing the probe directly on the metal sites also increases the relevant data acquisition rate by more than an order of magnitude over two-dimensional mapping, enabling improved statistical measurements of site properties. The versatility, sensitivity, and speed that these techniques provide enhances our ability to probe the local elemental and chemical environment of a large number of individual SAE metal site structures at the atomic scale, enabling an improved understanding of the variations in the local properties of these electrocatalysts to be gained. As a result, significantly increased information about individual metal sites will be available to future electrochemical studies through these techniques, accelerating the development of advanced SAEs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stereoscopic high-speed microscopy to understand transient internal flow processes in high-pressure nozzles

The flow and cavitation behavior inside fuel injectors is known to affect spray development, mixing and combustion characteristics. We discuss that while diesel fuel injectors with converging and hydro-eroded holes are generally known to limit cavitation and feature higher discharge coefficients during the steady period of injection, less is known about the flow during transient periods corresponding to needle opening and closing. Multiple injection strategies involve short injections, multiplying these aspects and giving them a growing importance as part of the fuel delivery process. In this study, single-hole transparent nozzles were manufactured with the same hole inlet radius and diameter as the Engine Combustion Network Spray D nozzle, mounted to a modified version of a common-rail Spray A injector body and needle. Needle opening and closing periods were visualized with stereoscopic high-speed microscopy at injection pressures relevant to modern diesel engines. Time-resolved sac pressure was extracted via elastic deformation analysis of the transparent nozzles. Sources of cavitation were observed and tracked, enabling the identification of a gas exchange process after the end of injection with ingestion of chamber gas into the sac and orifice. We observed that the gas exchange contributed widely to disrupting the start of injection and outlet flow during the subsequent injection event.

42 ENGINEERING↗

X-Ray Fluorescence Microscopy: A Method of Measuring Ion Concentrations in the Ear

This technical note describes synchrotron x-ray fluorescence microscopy (XFM) as a method for measuring the concentrations of various elements in cross-sections of the ear at extremely high resolution. This method could be of great importance for addressing many open questions in hearing research. XFM uses synchrotron radiation to evoke emissions from many biologically relevant elements in the tissue. The intensity and wavelength of the emitted radiation provide a fingerprint of the tissue composition that can be used to measure the concentration of the elements in the sampled location. Here, we focus on energies that target biologically-relevant elements of the periodic table between magnesium and zinc. Since a highly focused x-ray beam is used, the spot size is well below 1 mu m and the samples can be scanned at a nanometer lateral resolution. This study shows that measurement of the concentrations of different elements is possible in a mid-modiolar cross-section of a mouse cochlea. Images are presented that indicate potassium and chloride "hot spots" in the spiral ligament and the spiral limbus, providing experimental evidence for the potassium recycling pathway and showing the cochlear structures involved. Scans of a section obtained from the incus, one of the middle ear ossicles, in a developing mouse have shown that zinc is not uniformly distributed This supports the hypothesis that zinc plays a special role in the process of ossification. Although limited by sophisticated sample preparation and sectioning, the method provides ample exciting opportunities, to understand the role of genetics and epigenetics on hearing mechanisms in ontogeny and phylogeny.

59 BASIC BIOLOGICAL SCIENCES↗

Reprint of "Selective conversion of CO into ethanol on Cu(511) surface reconstructed from Cu(pc): Operando studies by electrochemical scanning tunneling microscopy, mass spectrometry, quartz crystal nanobalance, and infrared spectroscopy"

A polycrystalline copper, surface-terminated by a well-defined (511)-oriented facet, was electrochemically generated by a series of step-wise surface reconstruction and iterations of mild oxidative-reductive processes in 0.1 M KOH. The electrochemical reduction of CO on the resultant stepped surface was investigated by four surface-sensitive operando methodologies: electrochemical scanning tunneling microscopy (STM), electrochemical quartz crystal nanobalance (EQCN), differential electrochemical mass spectrometry (DEMS), and polarization-modulation infrared spectroscopy (PMIRS). The stepped surface catalyzed the facile conversion of CO into ethanol, the exclusive alcohol product at a low overpotential of -1.06 V (SHE) or - 0.3 V (RHE). Additionally, the chemisorption of CO was found to be a necessary prelude to ethanol production; i.e. the surface coverages, rather than solution concentrations, of CO and its surface-bound intermediates primarily dictate the reaction rates (current densities). Contrary to the expected predominance of undercoordinated step-site reactivity over the coordination chemistry of vicinal surfaces, vibrational spectroscopic evidence reveals the involvement of terrace-bound CO adsorbates during the multi-atomic transformations associated with the production of ethanol.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adapting confocal Raman microscopy for in situ studies of redox transformations at electrode-electrolyte interfaces

Confocal Raman microscopy was applied to quantify redox species present within the diffusion layer adjacent to an electrode surface under potentiostatic control. A glass microscope coverslip with a thin indium tin oxide (ITO) coating served as both the working electrode and optical window for a microscope-stage mountable spectroelectrochemical cell. A high numerical aperture objective mounted in an inverted microscope frame just below the stage brought excitation radiation through the coverslip window and to a tight focus a few micrometers above the ITO film surface. Species diffusing into the confocal probe volume defined by the excitation beam focus and the collected light region were detected, identified and quantified based on their Raman scattering frequencies and intensities. Here, in measurements that interrogated the interconversion of ferrocyanide and ferricyanide ions as a function of applied voltage, least-squares regression analysis of spectral datasets predicted the formal potential and relative surface concentrations of the ions in good agreement with the expected Nernstian response. Preliminary studies of methyl viologen reduction at an ITO film/Nafion membrane interface were conducted and show the possibility for estimation of mass transport coefficients of redox species within ionic polymer materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomic force microscopy monitoring of subcritical slow crack growth in soda lime silicate glass

Prediction of brittle fracture in silicate glasses requires a fundamental understanding of slow crack growth rates, far below the critical stress intensity (K IC ) of the material. Here, in this study, atomic force microscopy (AFM) was used to characterize slow crack propagation in soda lime silicate glasses. Using large-sample AFM systems with specialized tips and scanners, fractures less than 20 nm wide were measured as a function of relative humidity (RH). The results were found to be sensitive to the type of AFM tip used and to the dryness of the surface. Continuous scanning and image capture over several days allowed the determination of the crack tip velocity. The dependance of crack tip velocity on RH was measured by enclosing the sample and AFM head in a humidity-controlled chamber. The crack tip velocity was measured as low 4.0×10 -12 m/s at 15 % RH and as high as 3.7×10 -10 m/s at 40 % RH. Overall crack growth was smooth during the AFM scan. Additionally, recession of the crack tip was noted as the sample dried, indicating crack tip closure may be occurring. Further studies on alternative compositions will provide details on subcritical fracture processes in a range of different environmental conditions.

Atomic force microscopy↗

Transmission electron microscopy investigation of phase transformation and fuel constituent redistribution in neutron irradiated U-10wt.%Zr fuel

Uranium-10wt.%zirconium (U-10wt.%Zr) is a primary candidate for fast reactor nuclear fuels. However, there is a lack of data characterizing neutron irradiated crystallographic phases and chemistry. In the current study, the microstructural evolution of a U-10wt.%Zr fuel neutron irradiated to a burnup of 5.7 at.% was investigated by scanning transmission electron microscopy, energy dispersive spectroscopy, and selected area electron diffraction to determine the major phases, alterations in microstructure, and variations in local chemical composition at different localities of a fuel cross-section. The current study revealed that the irradiated U-10wt.%Zr fuel was comprised of various major phases, including a-U, ß-U, and d-UZr2, as well as amorphous and crystalline solid fission product (FP) precipitates within different regions of the fuel cross-section. Regions A and A/B in the center of the fuel were comprised of U-rich, U-intermediate, and U-lean localities with a-U and d-UZr 2 composing the major phases. Regions B and C in the intermediate and peripheral fuel localities, respectively, were comprised of a-U grains, U-rich (ß-U) grains with Zr-rich precipitates, U-intermediate grains (d-UZr2), and solid FP precipitates. The major phases identified were associated with the nanoscopic chemical concentrations, the phase diagram, and the as-characterized specimen temperature, with the exception of the non-equilibrium ß-U phase identified in region B. The U-lean localities in regions A, A/B, B, and C were Zr-enriched pathways along subgrain/grain boundaries. This phenomenon suggests that Zr is susceptible to radiation-induced segregation in U-Zr fuels and indicates a new mechanism for constituent redistribution.

36 MATERIALS SCIENCE↗

Transmission Electron Microscopy Characterization of Fuel Cladding Chemical Interaction between Minor Actinides bearing U-Pu-Zr Fuel and AIM1 Cladding

Minor actinides (MA) significantly contribute to the long-term radiotoxicity of spent nuclear fuel (SNF). Separating MA from SNF and incorporating it into metallic fuels for fast reactor transmutation is a potential method to reduce this radiotoxicity. Here, this study focuses on transmission electron microscopy characterization of two samples from the fuel cladding chemical interaction (FCCI) region of an americium (Am) and neptunium (Np)-bearing (MA-bearing) uranium-plutonium-zirconium (U-Pu-Zr) fuel irradiated in the Phenix fast reactor to 9.5 % FIMA burnup at approximately 550 °C cladding temperature. The results show that despite the complex chemical interactions between MA and AIM1 cladding elements, excessive FCCI was not induced, and Am penetration depth in the cladding limited to less than 4 µm. Np remained mostly inside fuel. The Zr-rich compounds layer effectively limited the accumulation of lanthanide on the inner cladding surface. Overall, the FCCI behavior between investigated MA-bearing U-Pu-Zr fuel and AIM1 cladding is benign.

Chemical interaction↗

An algorithm for resolving intragranular orientation fields using coupled far-field and near-field high energy $\mathrm{X}$-ray diffraction microscopy

Here, we present a novel algorithm for reconstructing spatial intragranular lattice orientation fields using both far-field and near-field high energy X-ray diffraction microscopy (HEDM) measurements. An established far-field indexing algorithm is modified to include lattice orientation distribution information (grain orientation envelopes) in addition to average grain orientations. The near-field data reduction algorithm utilizes this enriched far-field orientation data as a seed for reconstructing intragranular spatial maps of lattice orientation from the diffraction images. The primary benefit of the new algorithm is a significant decrease in the number of trial calculations that must be performed in the reconstruction process compared to existing methodologies while maintaining scalability. The resulting gains in efficiency facilitate the use of relatively modest computational resources and improve throughput at the point of measurement. We provide two example applications: volumetric orientation field reconstructions for a Ti-Al alloy both before and after the application of 3% uniaxial strain. The results showcase the efficiency of the new method and the ability to resolve subtle changes in microstructure, which are associated with incipient plastic deformation.

36 MATERIALS SCIENCE↗

Super-resolution model for overlapping peak detection and improved spatial resolution in high-energy diffraction microscopy

Reconstruction quality in Far-field High-Energy Diffraction Microscopy (FF-HEDM) is limited by the spatial resolution of area detectors and the frequent occurrence of overlapping diffraction spots. To address these challenges, we developed a super-resolution (SR) framework using convolutional neural networks (CNNs) to recreate 2D diffraction peaks at up to ×8 resolution from raw detector data. A specialized simulation tool was created to generate synthetic training datasets with varying degrees of peak overlap. Integrated into the Microstructural Imaging using Diffraction Analysis Software (MIDAS), the SR model improves the spatial accuracy and precision of 3D grain reconstruction by an order of magnitude. This approach provides a robust solution for investigation of complex micromechanical states and material classes where the analysis is limited by the presence of overlapping peaks. Furthermore, the methodology developed here can potentially be extended to other techniques that require sub-pixel accuracy for high-fidelity data analysis.

High-energy diffraction microscopy↗