Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNET SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

A Review of Nonscaling CW FFAs for Proton and Ion Therapy Applications

Significant progress on compact, variable-energy versions of non-scaling fixed field accelerators with alternating strong-focusing gradients (nsFFA) has been made and adapted to proton and ion therapy. Not only has isochronous (CW) capability been demonstrated in a realizable design, an isochronous racetrack format has evolved which supports lengthy, synchrotron-like straight sections. Long straight insertions promote low-loss injection and extraction systems and further facilitate extracting lower-energy orbits using a bipolar bump-magnet system. To efficiently extract variable energy using this method, the accelerator complex requires separated accelerator stages, each stage with limited but therapeutically optimized energy ranges targeting specific cancer types and penetration depths. Different energy stages further support multiple treatment rooms increasing patient throughput and reducing treatment cost. The staged system proposed here also realizes cost savings in gantries by tailoring delivery to different therapeutic energies and beam requirements, promoting the requirement for only one high-energy gantry in the facility. The proposed facility consists of 3 stages, a 30 MeV injector, a 30 - 90 MeV/nucleon FFA for shallow cancers, and 90 - 250/330 MeV/nucleon stage for deep tumors, pelvis for example. The higher energy of the final stage, 330 MeV/nucleon is preferred to support Proton Computed Tomography. Isochronous FFA stages can be designed to accelerate either protons or ions with charge to mass of 1/2.

43 PARTICLE ACCELERATORS↗

All-optical, Microwave-free NV-Diamond Magnetometer for Weak Magnetic Field Environments

Sensitive nitrogen-vacancy (NV) magnetometry typically requires a bias field to lift the spin level degeneracy and has commonly utilized microwave sources to selectively manipulate the sensor's spin state. However, this external bias field and microwave sources may perturb the sample of interest or be incompatible with operational conditions. Here, we demonstrate an all-optical, microwave-free NV-diamond magnetometer in the presence of weak or no bias magnetic field (<20 G). We experimentally measure photoluminescence spectra using diamonds with varying NV concentrations; and numerically simulate matching features due to cross-relaxation between NVs. Our results pave the way towards a sensitive probe to study magnetic systems that can be disrupted by microwave signals and can only tolerate weak bias magnetic field.

Ung, Kristine↗

Low-energy-state dynamics of entanglement for spin systems

We develop the ideas of the quantum renormalization group and quantum information by exploring the low-energy-state dynamics of entanglement resources of a system close to its quantum critical point. We demonstrate that low-energy-state dynamical quantities of one-dimensional magnetic systems can show a quantum phase transition point and show scaling behavior in the vicinity of the transition point. To present our idea, we study the evolution of two spin entanglements in the one-dimensional Ising model in the transverse field. The system is initialized as the so-called thermal ground state of the pure Ising model. We investigate the evolution of the generation of entanglement with increasing magnetic field. We obtain that the derivative of the time at which the entanglement reaches its maximum with respect to the transverse field diverges at the critical point and its scaling behaviors versus the size of the system are the same as the static ground-state entanglement of the system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Distinguishing magnetic particle size of iron oxide nanoparticles with first-order reversal curves

Magnetic nanoparticles encompass a wide range of scientific study and technological applications. The success of using the nanoparticles in various applications demands control over size, dispersibility, and magnetics. Hence, the nanoparticles are often characterized by transmission electron microscopy (TEM), X-ray diffraction, and magnetic hysteresis loops. TEM analysis requires a thin layer of dispersed particles on the grid, which may often lead to particle aggregation thus making size analysis difficult. Magnetic hysteresis loops on the other hand provide information on the bulk property of the material without discriminating size, composition, and interaction effects. First order reversal curves (FORCs), described as an assembly of partial hysteresis loops originating from the major loop are efficient in identifying the domain size, composition, and interaction in a magnetic system. This study presents FORC diagrams on a variety of well-characterized biogenic and synthetic magnetite nanoparticles. It also introduces deconvoluted reversible and irreversible components from FORC as an important method for obtaining a semi-quantitative measure of the effective magnetic particle size. This is particularly important in a system with aggregation and interaction among the particles that often leads to either the differences between physical size and effective magnetic size. We also emphasize the extraction of secondary components by masking dominant coercivity fraction on FORC diagram to explore more detailed characterization of nanoparticle systems.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Accelerating self-consistent field iterations in Kohn-Sham density functional theory using a low-rank approximation of the dielectric matrix

We present an efficient preconditioning technique for accelerating the fixed-point iteration in real-space Kohn-Sham density functional theory (DFT) calculations. The preconditioner uses a low-rank approximation of the dielectric matrix (LRDM) based on Gâteaux derivatives of the residual of fixed-point iteration along appropriately chosen direction functions. We develop a computationally efficient method to evaluate these Gâteaux derivatives in conjunction with the Chebyshev filtered subspace iteration procedure, an approach widely used in large-scale Kohn-Sham DFT calculations. Further, we propose a variant of LRDM preconditioner based on adaptive accumulation of low-rank approximations from previous self-consistent field iterations, and also extend the LRDM preconditioner to spin-polarized Kohn-Sham DFT calculations. We demonstrate the robustness and efficiency of the LRDM preconditioner against other widely used preconditioners on a range of benchmark systems with sizes ranging from ~100 to 1100 atoms (~500–20,000 electrons). The benchmark systems include various combinations of metal-insulating-semiconducting heterogeneous material systems, nanoparticles with localized d orbitals near the Fermi energy, nanofilm with metal dopants, and magnetic systems. In all benchmark systems, the LRDM preconditioner converges robustly within 20–30 iterations. In contrast, other widely used preconditioners show slow convergence in many cases, as well as divergence of the fixed-point iteration in some cases. Lastly, we demonstrate the computational efficiency afforded by the LRDM method, with up to 3.4-fold reduction in computational cost for the total ground-state calculation compared to other preconditioners.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

HTS Dipole Prototype Magnet for NSLS X13A Endstation

This article reports the design, three-dimensional magnetostatic simulation results, coil fabrication, assembly, and low-temperature test results of a C-frame, iron-dominated high-temperature superconductor dipole magnet for ultra high vacuum magnetic-sensitive spectroscopy techniques at the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory. The magnet is required to provide fields up to ~1 T along two spatial directions. With an added capability to rotate about its vertical axis of symmetry, the magnet system is capable of delivering field along all three principal axes. The combination of this magnet and fast-switched, elliptically polarized soft X-rays produced by the NSLS elliptically polarized wiggler forms the basis for an excellent tool for polarization-sensitive studies of magnetic materials. The prototype magnet consists of a set of pancake coils fabricated from BSCCO tape reinforced with stainless steel. Those pancake coils are clamped in a low-carbon AISI 1006 grade steel pole and yoke assembly. For testing purposes, a cold He gas environment provided cooling the superconducting magnet to subtransition temperatures; for operation in an ultra high vacuum endstation environment, cooling can be provided by an external cryocooler. The low-temperature tests establish the safe-operating parameters needed to achieve the target magnetic field values. The measured magnetic field values are in close agreement with the magnetic simulation results, thereby confirming that the magnet design fulfills the performance requirements. Here, the final section of this article lists some suggestions to improve the magnet performance.

36 MATERIALS SCIENCE↗

Design and Testing of Subsystems for Mo-99 Production Facility

Three beamline configurations have been proposed for the SHINE Medical Technologies facility for producing fission-product 99 Mo using a D/T-accelerator (Figure 1). One configuration, proposed by Los Alamos National Laboratory (LANL), includes a three-bend magnet system with a total 20° bending angle. This configuration also includes a set of octuplet magnets to generate a non-Gaussian beam profile. Argonne has proposed two beamlines based on a (1) 10° bending magnet (Appendix A and Ref. 1) and (2) alpha magnets (Appendix B) that use a pair of raster doublets to redistribute the beam over the face of the target. This report gives an overview of the various designs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct measurement of the impulse in a magnetic thrust chamber system for laser fusion rocket

An experiment is conducted to measure an impulse for demonstrating a magnetic thrust chamber system for laser fusion rocket. The impulse is produced by the interaction between plasma and magnetic field. In the experiment, the system consists of plasma and neodymium permanent magnets. The plasma is created by a single-beam laser aiming at a polystyrene spherical target. The impulse is 1.5 to 2.2 {mu}Ns by means of a pendulum thrust stand, when the laser energy is 0.7 J. Without magnetic field, the measured impulse is found to be zero. These results indicate that the system for generating impulse is working.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Review of field-reversed configurations

This review addresses field-reversed configurations (FRCs), which are compact-toroidal magnetic systems with little or no toroidal field and very high {beta} (ratio of plasma pressure to magnetic pressure). Although enthusiasm for the FRC has primarily been driven by its potential for an attractive fusion reactor, this review focuses on the physics rather than on technological or engineering aspects. Major advances in both theory and experiment have taken place since the previous comprehensive FRC review in 1988. Even so many questions remain. In particular, even though FRC experiments have exhibited remarkable stability, how well this extrapolates to larger systems remains unresolved. The review considers FRCs under familiar topical categories: equilibrium, global stability, self-organization, transport, formation, and sustainment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Emergent reduced dimensionality by vertex frustration in artificial spin ice

Reducing the dimensionality of a physical system can have a profound effect on its properties, as in the ordering of low-dimensional magnetic materials, phonon dispersion in mercury chain salts, sliding phases, and the electronic states of graphene. Here we explore the emergence of quasi-one-dimensional behaviour in two-dimensional artificial spin ice, a class of lithographically fabricated nanomagnet arrays used to study geometrical frustration. We extend the implementation of artificial spin ice by fabricating a new array geometry, the so-called tetris lattice. We demonstrate that the ground state of the tetris lattice consists of alternating ordered and disordered bands of nanomagnetic moments. The disordered bands can be mapped onto an emergent thermal one-dimensional Ising model. Furthermore, we show that the level of degeneracy associated with these bands dictates the susceptibility of island moments to thermally induced reversals, thus establishing that vertex frustration can reduce the relevant dimensionality of physical behaviour in a magnetic system.

36 MATERIALS SCIENCE↗

Skyrmion lattice formation and destruction mechanisms probed with TR-SANS

Magnetic skyrmions are topologically protected, nanoscale whirls of the spin configuration that tend to form hexagonally ordered arrays. As a topologically non-trivial structure, the nucleation and annihilation of the skyrmion, as well as the interaction between skyrmions, varies from conventional magnetic systems. Recent works have suggested that the ordering kinetics in these materials occur over millisecond or longer timescales, which is unusually slow for magnetic dynamics. The current work investigates the skyrmion ordering kinetics, particularly during lattice formation and destruction, using time-resolved small angle neutron scattering (TR-SANS). Evaluating the time-resolved structure and intensity of the neutron diffraction pattern reveals the evolving real-space structure of the skyrmion lattice and the timeframe of the formation. Measurements were performed on three prototypical skyrmion materials: MnSi, (Fe,Co)Si, and Cu 2 OSeO 3 . To probe lattice formation and destruction kinetics, the systems were prepared in the stable skyrmion state, and then a square-wave magnetic field modulation was applied. The measurements show that the skyrmions quickly form ordered domains, with a significant distribution in lattice parameters, which then converge to the final structure; the results confirm the slow kinetics, with formation times between 10 ms and 99 ms. Comparisons are made between the measured formation times and the fundamental material properties, suggesting the ordering temperature, saturation magnetization and magnetocrystalline anisotropy may be driving the timeframes. Micromagnetic simulations were also performed and support a scaling of the kinetics with sample volume, a behavior which is caused by the reconciling of misaligned domains.

Liyanage, W. L. N. C.↗

Influence of Photospheric Magnetic Conditions on the Catastrophic Behaviors of Flux Ropes in Solar Active Regions

Since only the magnetic conditions at the photosphere can be routinely observed in current observations, it is of great significance to determine the influences of photospheric magnetic conditions on solar eruptive activities. Previous studies about catastrophe indicated that the magnetic system consisting of a flux rope in a partially open bipolar field is subject to catastrophe, but not if the bipolar field is completely closed under the same specified photospheric conditions. In order to investigate the influence of the photospheric magnetic conditions on the catastrophic behavior of this system, we expand upon the 2.5-dimensional ideal magnetohydrodynamic model in Cartesian coordinates to simulate the evolution of the equilibrium states of the system under different photospheric flux distributions. Our simulation results reveal that a catastrophe occurs only when the photospheric flux is not concentrated too much toward the polarity inversion line and the source regions of the bipolar field are not too weak; otherwise no catastrophe occurs. As a result, under certain photospheric conditions, a catastrophe could take place in a completely closed configuration, whereas it ceases to exist in a partially open configuration. This indicates that whether the background field is completely closed or partially open is not the only necessary condition for the existence of catastrophe, and that the photospheric conditions also play a crucial role in the catastrophic behavior of the flux rope system.

79 ASTRONOMY AND ASTROPHYSICS↗

State switching kinetics for quasi-one-dimensional nanosystems: Effects of Finite length and irradiation

The state switching in an extended quasi-one-dimensional material is modeled by the stochastic formation of local new-state nuclei and their subsequent growth along the system axis. An analytical approach is developed to describe the influence of defects, dividing a sample into an ensemble of finite-length segments, on its state switching kinetics. As applied to magnetic systems, the method makes it possible to calculate magnetization curves for different defect concentrations and parameters of material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and Testing of Subsystems for Mo-99 Production Facility

So far, three beamline configurations have been proposed for the SHINE Medical Technologies facility for producing fission-product 99 Mousing a D/T-accelerator (Figure 1). One configuration, proposed by Los Alamos National Laboratory (LANL), includes a three-bend magnet system with a total 20 o bending angle. This configuration also includes a set of octuplet magnets to generate a non-Gaussian beam profile. Argonne has proposed two beamlines based on a (1)10° bending magnet (Appendix A and Ref. 1) and (2) alpha magnets (Appendix B) that use a pair of raster doublets to redistribute the beam over the face of the target. While those configurations are quite different, and each of the configurations has its advantages and disadvantages, they all have to incorporate the means to verify beam parameters before placing the beam on the target, monitor beam position and shape during a run, protect the target housing from the overheating due to beam displacement, and protect the beamlines from overheating due to beam misalignment.

07 ISOTOPE AND RADIATION SOURCES↗

Design of Helical Cooling Channel for Muon Collider

Fast muon beam six dimensional (6D) phase space cooling is essential for muon colliders. The Helical Cooling Channel (HCC) uses hydrogen-pressurized RF cavities imbedded in a magnet system with solenoid, helical dipole, and helical quadrupole components that provide the continuous dispersion needed for emittance exchange and effective 6D beam cooling. A series of HCC segments, each with sequentially smaller aperture, higher magnetic field, and higher RF frequency to match the beam size as it is cooled, has been optimized by numerical simulation to achieve a factor of 10{sup 5} emittance reduction in a 300 m long channel with only a 40% loss of beam. Conceptual designs of the hardware required for this HCC system and the status of the RF studies and HTS helical solenoid magnet prototypes are described.

43 PARTICLE ACCELERATORS↗

Design and fabrication of a superconducting magnet for an 18 GHz electron cyclotron resonance ion/photon source NFRI-ECRIPS

A superconducting magnet was designed and fabricated for an 18 GHz ECR ion/photon source, which will be installed at National Fusion Research Institute (NFRI) in South Korea. The magnetic system consists of a set of four superconducting coils for axial mirror field and 36 pieces of permanent magnets for hexapolar field. The superconducting coils with a cryocooler (1.5 W - 4.2 K) allow one to reach peak mirror fields of 2.2 T in the injection and those of 1.5 T in the extraction regions on the source axis, and the resultant hexapolar field gives 1.35 T on the plasma chamber wall. The unbalanced magnetic force between the coils and surrounding yoke has been minimized to 16 ton by a coil arrangement and their electrical connection, and then was successfully suspended by 12 strong thermal insulating supports made of large numbers of carbon fibers. In order to block radiative thermal losses, multilayer thermal insulations are covered on the coil windings as well as 40-K aluminum thermal shield. Also new schemes of quench detection and safety system (coil divisions, quench detection coils, and heaters) were employed. For impregnation of the windings a special epoxy has been selected and treated to have a higher breaking strength and a higher thermal conductivity, which enables the superconductors to be uniformly and rapidly cooled down or heated during a quench.

43 PARTICLE ACCELERATORS↗

Evaluation of an active magnetic resonance tracking system for interstitial brachytherapy

Purpose: In gynecologic cancers, magnetic resonance (MR) imaging is the modality of choice for visualizing tumors and their surroundings because of superior soft-tissue contrast. Real-time MR guidance of catheter placement in interstitial brachytherapy facilitates target coverage, and would be further improved by providing intraprocedural estimates of dosimetric coverage. A major obstacle to intraprocedural dosimetry is the time needed for catheter trajectory reconstruction. Herein the authors evaluate an active MR tracking (MRTR) system which provides rapid catheter tip localization and trajectory reconstruction. The authors assess the reliability and spatial accuracy of the MRTR system in comparison to standard catheter digitization using magnetic resonance imaging (MRI) and CT. Methods: The MRTR system includes a stylet with microcoils mounted on its shaft, which can be inserted into brachytherapy catheters and tracked by a dedicated MRTR sequence. Catheter tip localization errors of the MRTR system and their dependence on catheter locations and orientation inside the MR scanner were quantified with a water phantom. The distances between the tracked tip positions of the MRTR stylet and the predefined ground-truth tip positions were calculated for measurements performed at seven locations and with nine orientations. To evaluate catheter trajectory reconstruction, fifteen brachytherapy catheters were placed into a gel phantom with an embedded catheter fixation framework, with parallel or crossed paths. The MRTR stylet was then inserted sequentially into each catheter. During the removal of the MRTR stylet from within each catheter, a MRTR measurement was performed at 40 Hz to acquire the instantaneous stylet tip position, resulting in a series of three-dimensional (3D) positions along the catheter’s trajectory. A 3D polynomial curve was fit to the tracked positions for each catheter, and equally spaced dwell points were then generated along the curve. High-resolution 3D MRI of the phantom was performed followed by catheter digitization based on the catheter’s imaging artifacts. The catheter trajectory error was characterized in terms of the mean distance between corresponding dwell points in MRTR-generated catheter trajectory and MRI-based catheter digitization. The MRTR-based catheter trajectory reconstruction process was also performed on three gynecologic cancer patients, and then compared with catheter digitization based on MRI and CT. Results: The catheter tip localization error increased as the MRTR stylet moved further off-center and as the stylet’s orientation deviated from the main magnetic field direction. Fifteen catheters’ trajectories were reconstructed by MRTR. Compared with MRI-based digitization, the mean 3D error of MRTR-generated trajectories was 1.5 ± 0.5 mm with an in-plane error of 0.7 ± 0.2 mm and a tip error of 1.7 ± 0.5 mm. MRTR resolved ambiguity in catheter assignment due to crossed catheter paths, which is a common problem in image-based catheter digitization. In the patient studies, the MRTR-generated catheter trajectory was consistent with digitization based on both MRI and CT. Conclusions: The MRTR system provides accurate catheter tip localization and trajectory reconstruction in the MR environment. Relative to the image-based methods, it improves the speed, safety, and reliability of the catheter trajectory reconstruction in interstitial brachytherapy. MRTR may enable in-procedural dosimetric evaluation of implant target coverage.

60 APPLIED LIFE SCIENCES↗

A table-top, repetitive pulsed magnet for nonlinear and ultrafast spectroscopy in high magnetic fields up to 30 T

We have developed a mini-coil pulsed magnet system with direct optical access, ideally suited for nonlinear and ultrafast spectroscopy studies of materials in high magnetic fields up to 30 T. The apparatus consists of a small coil in a liquid nitrogen cryostat coupled with a helium flow cryostat to provide sample temperatures down to below 10 K. Direct optical access to the sample is achieved with the use of easily interchangeable windows separated by a short distance of ∼135 mm on either side of the coupled cryostats with numerical apertures of 0.20 and 0.03 for measurements employing the Faraday geometry. As a demonstration, we performed time-resolved and time-integrated photoluminescence measurements as well as transmission measurements on InGaAs quantum wells.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗