Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Load flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Dynamic Modeling, Parameter Estimation, and Data Reconciliation of a Supercritical Pulverized Coal-Fired Boiler

A high-fidelity, spatially distributed dynamic model of a supercritical pulverized coal-fired boiler was developed for calculating transient thermal profiles of the boiler tubes, which are often not measured or unmeasurable in industrial settings due to the harsh operating conditions. In this work, rigorous models of the subcritical and supercritical steam properties, which can be highly nonlinear, were used to capture the transition between two-phase and one-phase flow, respectively, as supercritical boilers frequently transition through the critical point during load-following operation. The transient boiler model was also used for data reconciliation and parameter estimation for the purpose of model validation against industrial data. An approach was developed to reduce the size of large-scale reconciliation problem by focusing on the implementation of bias terms for the reconciled variables, which can be estimated in place of the reconciled variables themselves. In addition, a functional approximation of the reconciliation problem was defined so that it can be more simply optimized. Combining this functional approximation optimization with reformulation of the reconciliation problem considering measurement biases can significantly improve the tractability of many such large-scale problems. The validated boiler model was then used to study transient responses under load-following operation with specific attention on the calculation of unmeasurable variables.

42 ENGINEERING↗

Optimal Design and Operation of Intensified Absorbers with 3D-Printed Packing for Solvent-Based CO 2 Capture

Many potential solvent-based carbon capture processes suffer from a high heat of absorption of CO 2 that adversely affects the thermodynamic driving force. While interstage coolers are often used for removing a portion of the generated heat by removing the solvent or a portion of the solvent from a stage and cooling and returning it back to the absorber, they can be placed only at discrete locations in the tower. This work investigates intensified absorbers with 3D-printed packing that includes an internal cooler and therefore can be potentially used for maximizing the operational efficiency of the absorbers for CO 2 capture. The intensified absorber is modeled by using a generic, first-principles, equation-oriented absorber column model. Since the placement of these intensified packings would cause a loss of area/volume used for mass transfer, optimization of the proposed intensified absorber is performed by optimally selecting the locations at which to place these devices and designing them such that the trade-off due to the addition of the heat removal area and the resulting loss in the mass transfer area is accounted for. Results show that optimally placed and designed intensified packings can lead to a significant increase in the capture efficiency of the process in comparison to a similar column with no internal cooling. It is also observed that by optimally placing and designing intensified packings, the lean solvent flow rate to the absorber can be decreased, and the CO 2 lean loading can be increased while still maintaining the same capture efficiency. These process changes can lead to a substantial reduction in the cost of capture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomic-scale homogeneous plastic flow beyond near-theoretical yield stress in a metallic glass

Abstract The onset of yielding and the related atomic-scale plastic flow behavior of bulk metallic glasses at room temperature have not been fully understood due to the difficulty in performing the atomic-scale plastic deformation experiments needed to gain direct insight into the underlying fundamental deformation mechanisms. Here we overcome these limitations by combining a unique sample preparation method with atomic force microscopy-based indentation, which allows study of the yield stress, onset of yielding, and atomic-scale plastic flow of a platinum-based bulk metallic glass in volumes containing as little as approximately 1000 atoms. Yield stresses markedly higher than in conventional nanoindentation testing were observed, surpassing predictions from current models that relate yield stress to tested volumes; subsequent flow was then established to be homogeneous without exhibiting collective shear localization or loading rate dependence. Overall, variations in glass properties due to fluctuations of free volume are found to be much smaller than previously suggested.

Yu, Jiaxin↗

Energy storage material and method of producing the same

The instant invention includes a spherical porous secondary silicon-based particle and methods for producing the same. The spherical porous secondary silicon-based particle is comprised of agglomerated primary silicon-based nanoparticles. The secondary particle comprises a carbon coating that reduces the effective exposed surface area of the primary particles to the electrolyte, thus improving first cycle efficiency. The secondary particle further comprises porous regions that enable the silicon nanoparticles to expand during lithiation. Advantages include ease of castability with micron-sized spherical particles, ease of mixing spherical particles, ease of flow for spherical particles in various processing steps, and ease with obtaining higher loading, which translates to higher areal capacity and overall energy density of the cell. A readily scalable process for producing the particles using low-cost materials and low-cost processing methods is disclosed.

Holt, Christopher T.↗

Solar-battery integrated DC system

A DC bus is connected to a PV array, a battery or both, to power a grid connected inverter load on the bus. A system and method is described for controlling current flow on a DC bus regardless of the type of inverter. A converter receives a DC battery voltage. A switching module controls current flow through the converter. A current generator generates a reference current in response to a reference voltage. A comparator connected at the output of the current generator compares the reference current with a battery current and outputs a signal to a controller. The controller generates a reference value. A PWM generator modulates the switch module to control current flow and energy flow between the DC bus and the battery. The current from the DC bus to the inverter is controlled to allow proper grid-connected operation regardless of inverter type.

Atcitty, Stanley↗

An Efficient Annual-Performance Model of a Geothermal Network for Improved System Design, Operation, and Control: Preprint

Geothermal district energy systems (DES), and specifically geothermal networks, provide a viable solution for decarbonizing residential and commercial heating and cooling loads. District energy systems of all kinds enable a thermal resource with a relatively high capital cost (such as a geothermal borehole field) to be shared among a large number of users. While district heating and cooling has been studied for many years, geothermal networks, fifth generation DES that utilize water-source heat pumps and an ambient temperature loop to meet heating and cooling loads, have not been implemented extensively and thus require additional technical and economic optimization to obtain maximum benefits. This paper presents a newly developed reduced-order model that captures the flow of energy within the network, including the commercial and residential users' electrical usage, at an hourly rate over a year. The model includes building loads, heat pumps, borehole fields, and auxiliary heat/cool input, all connected with an ambient-temperature thermal loop model. In the model, operational control is possible for the borehole fields, circulation pump, and auxiliary system. For a given system, the model can output the complete state parameters for each component, the thermal loop, and the collective system, such as flow rate over time, average thermal loop temperature over time, and total electricity usage. The model can also be used to optimize the system control for maximizing system efficiency or minimizing system operational cost. For example, one initial assessment of the borehole controller for an example system showed that a controller with on/off operation of the borehole field reduces annual electrical usage by 33%, compared with continuous operation mode. Hence, the model can assist in optimizing a given system's operation to get the most value out of a geothermal network installation. Future work will consider the model's application to a demonstration project, including the model validation against operational data and system operation optimization.

ambient-temperature loop↗

EXPERIMENTAL AND MODELLING ANALYSIS OF A LARGE-SCALE TWO-PHASE LOOP THERMOSYPHON

Liquid pumping requires large quantities of electrical energy, including about 7% of the energy of building heating, ventilation, and air conditioning (HVAC) systems. To replace pumped condenser-cooling tower water loops with a passive alternative system, we implemented a commercial-scale two-phase loop thermosyphon (TPLT). The unit consists of a 13 m riser integrated with a commercially available cooling tower and circulation water heater that simulates heat loads up to 25 kW. In addition to providing passive cooling capabilities, the cooling tower unit is also maintenance free, reliable, and can operate in both dry and wet modes. This study characterizes the performance (temperature difference between the evaporator and condenser) and the two-phase flow behavior of the loop under various refrigerant charges. Sight glasses installed throughout the loop are used to identify the operating flow regimes in the riser and downcomer. Over the range of operating conditions, we identified that there is an optimal refrigerant charge range for a specific heat load at which near-isothermal operation can be achieved. We further developed a model to predict the operating flow rate and gravitational height in the downcomer and compared it with the experimental data. The results show that the model agrees with the experimental data, in particular the threshold gravitational head height at which there will be subcooled liquid at the condenser exit, indicating that it can be used as a predictive tool for identifying the optimal loop charge for a given heat load.

Loop thermosyphon, passive two phase↗

Coupled methane and NO x conversion on Pt + Pd/Al 2 O 3 monolith: Conversion enhancement through feed modulation and Mn 0.5 Fe 2.5 O 4 spinel addition

The performance of a dual-layer Pt-Pd/Al 2 O 3 washcoated monolith promoted by an Al 2 O 3 -supported Mn 0.5 Fe 2.5 O 4 spinel base layer was evaluated with the objective to develop a catalyst with a lower loading of Platinum group metal (PGM) for stoichiometric natural gas vehicle (NGV) emission control. Flow reactor results show that a combination of a lean/rich modulated feed and spinel addition gives enhanced methane and NO conversions compared to a steady-state feed having the same overall composition. Washcoated catalysts – PGM-only, spinel-only, PGM + spinel – were compared over a wide range of operating conditions. The results show a decrease in the methane conversion light-off temperature of up to 85 °C for an application-relevant feed (CH 4 + NO + H 2 + CO + O 2 + H 2 O + CO 2 ) while a moderate 40 °C decrease was observed for a simple feed (CH 4 + O 2 + H 2 O + CO 2 ). In the absence of spinel the modulation enhancement is negatively impacted at high methane conversion (> 80 %). The data show that the O 2 storage and release property of the spinel is needed to fully exploit the modulation enhancement. The mechanism responsible for the enhancement is linked to suppression of O 2 inhibition on the methane oxidation rate near the stoichiometric neutral point (λ = 1). Sufficiently fast cycling achieves a balance between a metallic and oxidic precious metal crystallites favorable for methane activation. The addition of spinel moves this balance closer to the λ = 1 feed, enabling a high oxidation efficiency with lower byproduct NH 3 selectivity. Enhancement in the NO conversion follows the methane conversion due to an easier NO reduction under the slightly rich of stoichiometric feed. Comparison of the PGM + spinel catalysts to PGM-only catalysts shows that the addition of spinel in combination with modulation can achieve the same activity with a lower PGM loading.

03 NATURAL GAS↗

A grid-scale study of demand bidding by large industrial users

A demand bidding mechanism for engaging large industrial electricity users in the operation of the power grid is presented. Demand bidding is formulated as an optimization problem based on a modified version of the alternating current optimal power flow problem, and can be interpreted as a tâtonnement process between the grid operator and electricity users. Here, the work provides the first – to the authors’ knowledge – grid-scale case study of demand bidding, using a synthetic grid structure in the footprint of the grid of Texas. Results reveal that the demand bidding lowers overall power generation costs, but economic benefits plateau as the number of participants increases. Transmission line and transformer capacity constraints become the limiting factors, revealing that expanding and fortifying the transmission infrastructure is key to expanding demand-side participation. Demand bidding does not substantially alter the optimal operation of existing bidding entities when the number of bidders increases, thereby supporting existing bidders to stay in the system and encouraging new ones to join.

Chlor-alkali plant↗

Towards Energy-Positive Buildings through a Quality-Matched Energy Flow Strategy

Current strategies for net-zero buildings favor envelopes with minimized aperture ratios and limiting of solar gains through reduced glazing transmittance and emissivity. This load-reduction approach precludes strategies that maximize on-site collection of solar energy, which could increase opportunities for net-zero electricity projects. To better leverage solar resources, a whole-building strategy is proposed, referred to as “Quality-Matched Energy Flows” (or Q-MEF): capturing, transforming, buffering, and transferring irradiance on a building’s envelope—and energy derived from it—into distributed end-uses. A mid-scale commercial building was modeled in three climates with a novel Building-Integrated, Transparent, Concentrating Photovoltaic and Thermal fenestration technology (BITCoPT), thermal storage and circulation at three temperature ranges, adsorption chillers, and auxiliary heat pumps. BITCoPT generated electricity and collected thermal energy at high efficiencies while transmitting diffuse light and mitigating excess gains and illuminance. The balance of systems satisfied cooling and heating demands. Relative to baselines with similar glazing ratios, net electricity use decreased 71% in a continental climate and 100% or more in hot-arid and subtropical-moderate climates. Total EUI decreased 35%, 83%, and 52%, and peak purchased electrical demands decreased up to 6%, 32%, and 20%, respectively (with no provisions for on-site electrical storage). Decreases in utility services costs were also noted. These results suggest that with further development of electrification the Q-MEF strategy could contribute to energy-positive behavior for projects with similar typology and climate profiles.

54 ENVIRONMENTAL SCIENCES↗

Multi-Time Scale Coordinated Control and Scheduling of Inverter-Based TCLs With Variable Wind Generation

To address microgrid tie flow errors caused by wind generation variability, here we propose and develop a multi-time scale coordinated control and scheduling strategy for inverter-based thermostatically controlled loads (TCLs). First, in hour-time scale, inverter-based TCLs with adjusting temperature set-point are modeled as virtual generators to compensate tie flow deviations in the day-ahead plan. Next, in minute-time scale, virtual batteries representing operating behaviors of inverter-based TCLs with frequency control are scheduled determined by the control of virtual generators in hour-time scale. The virtual batteries are scheduled to smooth out tie flow errors corresponding to day-ahead plan and hour-time scale schedules. The multi-time scale control methods are coordinated to employ the response potential of inverter-based TCLs and response curve-based methods are proposed to control inverter-based TCLs considering the customer privacy. The multi-time scale stochastic schedules which are based on response curves of inverter-based TCLs are coordinated to accommodate wind generation variability. Simulation results demonstrate that the microgrid tie flow errors are effectively mitigated by the proposed multi-time scale coordinated control and scheduling of inverter-based TCLs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On how avalanches penetrate the SOL and broaden heat loads

Recent experiments reported a correlation between power law core temperature spectra and Dα emission, suggesting that heat avalanches penetrate the SOL. This paper derives a threshold criterion for avalanche penetration using a reduced model. Avalanches with ($\bigtriangledown$$\tilde{T}$) rms > $\bigtriangledown$$\tilde{T}$ crit at the separatrix are predicted to penetrate, and so broaden the SOL and heat load distribution. $\bigtriangledown$$\tilde{T}$ crit is ~ 1/$τ$ ∥ , where $τ$ ∥ is the parallel heat flow time through the SOL. Penetration occurs when avalanches are strong enough to steepen sufficiently to shock at the separatrix. A positive correlation is found between the nonlinear drive for steepening and the penetration depth. In particular, penetration depth exceeds that of the heuristic drift limit when shocks form. Implications for numerical and physical experiments are also discussed.

SOL heat load↗

Assessment of reverse gun taylor cylinder experimental configuration

Experimental efforts for Taylor-anvil impact tests have often been limited to near room temperature. The ‘Reverse Gun’ method proposed by Gust in 1982 allows for the Taylor impact specimen to be uniformly heated without temperature losses before impact. Through the use of finite element analysis, we explore two topics in this work. First, we examine whether the reverse gun experimental configuration is comparable to the traditional Taylor-anvil setup. Second, we assess the accuracy of several commonly employed flow strength models in terms of their ability to predict the reverse gun experimental results which involve dynamic loading conditions and complex thermo-mechanical coupling. The reverse gun simulations are performed for tantalum targets at initial temperatures in the range 295 K to 1295 K and velocities from 135 m/s to 242 m/s. We show that with suitable care in the modeling of the preheated reverse gun experiments one can make valuable assessments of flow strength models. Given the conditions explored, these observations probe the thermal softening, strain hardening, and strain rate sensitivity of the material.

42 ENGINEERING↗

A GPU-based compressible combustion solver for applications exhibiting disparate space and time scales

High-speed chemically active flows pose significant computational challenges due to their disparate space and time scales, with stiff chemistry often dominating simulation time. While modern scientific computing programs achieve exascale performance by leveraging graphics processing units (GPUs), existing GPU-based compressible combustion solvers face critical limitations in memory management, load balancing, and handling the highly localized nature of chemical reactions. To this end, we present a high-performance compressible reacting flow solver built on the AMReX framework and optimized for multi-GPU settings. Here, our approach addresses three GPU performance bottlenecks: memory access patterns through column-major storage optimization, computational workload variability via a bulk-sparse integration strategy for chemical kinetics, and multi-GPU load distribution for adaptive mesh refinement applications. The solver adapts existing matrix-based chemical kinetics formulations to multi-grid contexts. Using representative combustion applications, including 2D and 3D detonations and a 3D jet-in-crossflow configuration, we demonstrate 1.4–5× performance improvements over initial implementations on an in-house cluster of NVIDIA H100 GPUs, and near-ideal weak scaling on the Frontier supercomputer (Oak Ridge Leadership Computing Facility) with up to 1024 AMD Instinct MI250X GPUs. Roofline analysis reveals substantial improvements in arithmetic intensity for both convection (∼ 10 ×) and chemistry (∼ 4 ×) routines, confirming efficient utilization of GPU memory bandwidth and computational resources.

42 ENGINEERING↗

Computational Fluid Dynamics Study of a Cross-Flow Marine Hydrokinetic Turbine and the Combined Influence of Struts and Helical Blades

A computational fluid dynamics study was performed for a cross-flow marine hydrokinetic turbine. The analysis was done in three dimensions and used the unsteady Reynolds-averaged Navier-Stokes solver in the commercial code STAR-CCM+. The base turbine configuration is the RivGen(R) Turbine, designed by the Ocean Renewable Power Company. A convergence and uncertainty analysis was performed for both the spatial and temporal discretization; this was done using the base configuration, which features support struts and helical foils. Both struts and helical blades introduce three-dimensional flow effects, influencing the complex flow phenomenon of dynamic stall. The study compares the relative impact of struts on power performance and blade loading for both helical and straight blades, and found that for this turbine the relative loss in power from struts was lower with helical blades.

CFD↗

Gas density structure of supersonic flows impinged on by thin blades for laser-plasma accelerator targets

Density transition injection is an effective technique for controllably loading electrons into a trapped phase for laser plasma accelerators. One common technique to achieve the required fluid structure is to impinge a thin blade on the plume of a supersonic nozzle. Density transitions induced in this way are often assumed to be bow shocks and therefore sharp, but simulations and fluorescence measurements presented in this work show that in many cases of interest, the density transition accessible to a laser propagating transverse to the shock is an intercepting shock, and therefore, shock thickness and density vary with pressure, laser height, and blade position. The fluid dynamics of a supersonic nozzle impinged on by a thin, flat object are explored through simulations and relevant features are verified via planar laser-induced fluorescence measurements. Overall, the implications of the results for tuning electron beam injectors in laser plasma accelerators are discussed.

42 ENGINEERING↗

Using numerical methods to screen magnetocaloric materials in an active magnetic regenerative cycle

A 2-dimensional numerical model of a room temperature operating Active Magnetic Regenerator (AMR) that comprises of a regenerator, hot and cold heat exchangers, heat transfer fluid is developed. The regenerator is made of a magnetocaloric material (MCM) which heats up upon applying a magnetic field, H, and cools down when the field is removed; thus, making it the most essential part of an AMR. The model takes experimentally measured ΔT ad (H,T) and the C p (H,T) data as input and provides quantitative performance metrics of the magnetic cooling system, such as ΔT span and the cooling load, as output. With this model, it is possible to assess a wide range of MCMs in an AMR. 4 different MCMs were investigated using this model in terms of their ΔT span and the cooling loads—LaFe 10.96 Co 0.97 Si 1.07 , MnFeP (1-x) As (x) and AlFe 2 B 2 and Gd. During the screening of MCMs, all the important operating conditions of the device were fixed such as the fluid flow rate, ambient temperature, cycle duration, magnetic field strength. Our results indicate that Gd exhibits the maximum ΔT span with respectable cooling load, while AlFe 2 B 2 generates the lowest ΔT span . Even though LaFeCoSi compound did not perform as well as Gd, it could be the MCM choice for the realization of magnetic refrigeration on a global scale due to its much lower cost.

36 MATERIALS SCIENCE↗

Heliostat Consortium: Gap Analysis on State of the Art in Wind Load Design

Wind loads are a major driver of heliostat cost. Standardized methods and tools are needed for a more detailed understanding of the static and dynamic loads of a heliostat design. This will enable cost reduction of wind-dependent heliostats to avoid unnecessarily conservative heliostat designs and increase field efficiency and reliability to reduce the risk of component failures due to high-wind events. Gaps related to wind load include lack of site characterization for wind measurements, insufficient critical load cases for heliostat design, insufficient understanding of turbulence impacts on heliostat tracking error, lack of knowledge on wind load under various heliostat array configurations, and underexplored heliostat field wind-load reduction and operating strategies. Recommended pathway forward is to develop wind load and site characterization guidelines for heliostat design and develop heliostat field wind-load models with optical performance impacts.

aerodynamics↗