Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Light sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Element- and Time-Resolved Measurements of Spin Dynamics Using X-ray Detected Ferromagnetic Resonance

Although XFMR experiments have been carried out at a number of synchrotron radiation facilities since 2004, only a few facilities currently have XFMR setups available for user operation. Here in this review, we mainly focus on recent developments and work that has been carried out using time-resolved XFMR at beamline 4.0.2 of the Advanced Light Source and at beamline I10 of the Diamond Light Source. The experimental setup and the sample holder used at beamline I10 and beamline 4.0.2, respectively, are shown in Figure 1. We will first introduce the working principle of XFMR and then provide examples of the capabilities of this technique. Finally, we will briefly describe an outlook for the future development of and new opportunities for XFMR.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Manipulation of quantum dot emission with semiconductor metasurfaces exhibiting magnetic quadrupole resonances

Optical metasurfaces were suggested as a route for engineering advanced light sources with tailored emission properties. In particular, they provide a control over the emission directionality, which is essential for single-photon sources and LED applications. Here, we experimentally study light emission from a metasurface composed of III-V semiconductor Mie-resonant nanocylinders with integrated quantum dots (QDs). Specifically, we focus on the manipulation of the directionality of spontaneous emission from the QDs due to excitation of different magnetic quadrupole resonances in the nanocylinders. To this end, we perform both back focal plane imaging and momentum-resolved spectroscopy measurements of the emission. This allows for a comprehensive analysis of the effect of the different resonant nanocylinder modes on the emission characteristics of the metasurface. Our results show that the emission directionality can be manipulated by an interplay of the excited quadrupolar nanocylinder modes with the metasurface lattice modes and provide important insights for the design of novel smart light sources and new display concepts.

Vaskin, Aleksandr↗

Evaluation of S190A radiometric exposure test data

The S190A preflight radiometric exposure test data generated as part of preflight and system test of KM-002 Sequence 29 on flight camera S/N 002 was analyzed. The analysis was to determine camera system transmission using available data which included: (1) films exposed to a calibrated light source subject; (2) filter transmission data; (3) calibrated light source data; (4) density vs. log10 exposure curves for the films; and (5) spectral sensitometric data for the films. The procedure used is outlined, and includes the data and a transmission matrix as a function of field position for nine measured points on each station-film-filter-aperture-shutter speed combination.

Lockwood, H. E.↗

X ray sensitive area detection device

A radiation sensitive area detection device is disclosed which comprises a phosphor-containing film capable of receiving and storing an image formed by a pattern of incoming x rays, UV, or other radiation falling on the film. The device is capable of fluorescing in response to stimulation by a light source in a manner directly proportional to the stored radiation pattern. The device includes: (1) a light source capable of projecting light or other appropriate electromagnetic wave on the film so as to cause it to fluoresce; (2) a means to focus the fluoresced light coming from the phosphor-containing film after light stimulation; and (3) at least one charged coupled detector or other detecting element capable of receiving and digitizing the pattern of fluoresced light coming from the phosphor-containing film. The device will be able to generate superior x ray images of high resolution from a crystal or other sample and will be particularly advantageous in that instantaneous near-real-time images of rapidly deteriorating samples can be obtained. Furthermore, the device can be made compact and sturdy, thus capable of carrying out x ray or other radiation imaging under a variety of conditions, including those experienced in space.

Carter, Daniel C.↗

Linear encoding device

A Linear Motion Encoding device for measuring the linear motion of a moving object is disclosed in which a light source is mounted on the moving object and a position sensitive detector such as an array photodetector is mounted on a nearby stationary object. The light source emits a light beam directed towards the array photodetector such that a light spot is created on the array. An analog-to-digital converter, connected to the array photodetector is used for reading the position of the spot on the array photodetector. A microprocessor and memory is connected to the analog-to-digital converter to hold and manipulate data provided by the analog-to-digital converter on the position of the spot and to compute the linear displacement of the moving object based upon the data from the analog-to-digital converter.

Leviton, Douglas B.↗

Measurement and Validation of Bidirectional Reflectance of Space Shuttle and Space Station Materials for Computerized Lighting Models

Task illumination has a major impact on human performance: What a person can perceive in his environment significantly affects his ability to perform tasks, especially in space's harsh environment. Training for lighting conditions in space has long depended on physical models and simulations to emulate the effect of lighting, but such tests are expensive and time-consuming. To evaluate lighting conditions not easily simulated on Earth, personnel at NASA Johnson Space Center's (JSC) Graphics Research and Analysis Facility (GRAF) have been developing computerized simulations of various illumination conditions using the ray-tracing program, Radiance, developed by Greg Ward at Lawrence Berkeley Laboratory. Because these computer simulations are only as accurate as the data used, accurate information about the reflectance properties of materials and light distributions is needed. JSC's Lighting Environment Test Facility (LETF) personnel gathered material reflectance properties for a large number of paints, metals, and cloths used in the Space Shuttle and Space Station programs, and processed these data into reflectance parameters needed for the computer simulations. They also gathered lamp distribution data for most of the light sources used, and validated the ability to accurately simulate lighting levels by comparing predictions with measurements for several ground-based tests. The result of this study is a database of material reflectance properties for a wide variety of materials, and lighting information for most of the standard light sources used in the Shuttle/Station programs. The combination of the Radiance program and GRAF's graphics capability form a validated computerized lighting simulation capability for NASA.

Fletcher, Lauren E.↗

Hard x-ray – optical four-wave mixing using a split-and-delay line

New, hard x-ray free electron lasers (FEL) produce intense femtosecond-to-attosecond pulses at angstrom wavelengths, giving access to the fundamental spatial and temporal scales of matter. These revolutionary light sources open the door to applying the suite of nonlinear, optical spectroscopy methods at hard x-ray photon energies. Nonlinear spectroscopy with hard x-rays can allow for measuring the coherence properties of short wavelength excitations with atomic specificity and for understanding how high energy excitations couple to other degrees of freedom in atomic, molecular or condensed-phase systems. As a step in this direction, here we present hard x-ray, optical four-wave mixing (4WM) measurements done at 9.8 keV at the split-and-delay line at the x-ray correlation spectroscopy (XCS) hutch of the Linac Coherent Light Source (LCLS). In this work, we create an x-ray transient grating (TG) from a pair of crossing x-ray beams and diffract optical laser pulses at 400 nm from the TG. The key technical advance here is being able to independently vary the delays of the x-ray pulses. Measurements were made in 3 different solid samples: bismuth germinate (BGO), zinc oxide (ZnO) and yttrium aluminum garnet (YAG). The resulting phase-matched, 4WM signal is measured in two different ways: by varying the x-ray, x-ray pulse delay which can reveal both material and light source coherence properties and also by varying the optical laser delay with respect to the x-ray TG to study how the x-ray excitation couples to the optical properties. Although no coherent 4WM signal was seen in these measurements, the absence of this signal gives important information on experimental requirements for detecting this in future work. Also, our laser-delay scans, although not a new measurement, were applied to different materials than in past work and reveal new examples x-ray induced lattice dynamics in solids. This work represents a key step towards extending nonlinear optics and time-resolved spectroscopy into the hard x-ray regime.

47 OTHER INSTRUMENTATION↗

Optoelectronic Instrument Monitors pH in a Culture Medium

An optoelectronic instrument monitors the pH of an aqueous cell-culture medium in a perfused rotating-wall-vessel bioreactor. The instrument is designed to satisfy the following requirements: It should be able to measure the pH of the medium continuously with an accuracy of 0.1 in the range from 6.5 to 7.5. It should be noninvasive. Any material in contact with the culture medium should be sterilizable as well as nontoxic to the cells to be grown in the medium. The biofilm that inevitably grows on any surface in contact with the medium should not affect the accuracy of the pH measurement. It should be possible to obtain accurate measurements after only one calibration performed prior to a bioreactor cell run. The instrument should be small and lightweight. The instrument includes a quartz cuvette through which the culture medium flows as it is circulated through the bioreactor. The cuvette is sandwiched between light source on one side and a photodetector on the other side. The light source comprises a red and a green light-emitting diode (LED) that are repeatedly flashed in alternation with a cycle time of 5 s. The responses of the photodiode to the green and red LEDs are processed electronically to obtain a quantity proportional to the ratio between the amounts of green and red light transmitted through the medium.

Anderson, Melody M.↗

Reduction and Agglomeration of Supported Metal Clusters Induced by High-Flux X-ray Absorption Spectroscopy Measurements

Supported metal clusters are widely used in catalysis for many important reactions. To understand the catalytic properties, in situ/operando characterization techniques, such as X-ray absorption spectroscopy (XAS), provide essential details of the size, shape, and chemical composition of the cluster and the nature of the active sites. New-generation synchrotrons combined with focusing beamlines provide high-flux-density X-rays for improved detection sensitivity as well as higher time and spatial resolution. Understanding the effects of a high-flux-density X-ray beam on the catalyst during the actual measurement, whether XAS or another synchrotron-based technique, is crucial. This is especially important for in situ and operando studies where both the high flux density and reaction conditions can affect the catalyst structure. In this work, we investigated the effect of the flux density on rhodium clusters supported on Al 2 O 3 at two different beamlines: National Synchrotron Light Source II beamline 08-ID and Stanford Synchrotron Radiation Light Source (SSRL) beamline 4-1. We show that the higher flux density at beamline 08-ID causes the reduction of the highly dispersed RhO x /Al 2 O 3 catalyst, even at room temperature. Additionally, exposure to the higher flux density X-rays at beamline 08-ID during in situ reduction results in significant agglomeration of the Rh clusters. The final size of the Rh nanoparticles reduced at 310 °C is equivalent to that of particles formed after the reduction at 600–650 °C in the absence of the beam. Significant beam-induced reduction and agglomeration is also shown for Ni supported on beta zeolite during in situ reduction at an intermediate-flux-density beamline 9-3 at SSRL, indicating that beam-induced changes in heterogeneous catalysts could be common at intermediate- and high-flux-density beamlines. We provide precautions and recommendations for detecting and minimizing beam damage during in situ/operando XAS measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temporal light modulation: A phantom array visibility measure

At temporal light modulation (TLM) frequencies between 80 Hz and 20 000 Hz observers may perceive a series of repeated images called the phantom array effect (PAE) when they move their eyes in large saccades across a modulating light source or across a scene lit by the modulating light source. To date, there is no well-established measure for quantifying PAE visibility, but there is growing awareness of the need for one among design professionals and sensitive populations. This paper documents a new measure, the phantom array visibility measure (PAVM), which is based on the results of recent human factors experiments. The measure follows the mathematical underpinning used by the flicker visibility measure and the stroboscopic visibility measure, where the time-domain TLM waveform is converted into its Fourier frequency components; each component is evaluated through a threshold curve of modulation depth, then summed through an equation employing a Minkowski exponent. This scales the PAVM so that a value of 1 indicates a waveform at a threshold visibility in the conditions of the underlying experiment.

Tan, J.↗

Fiber Optic Raman Sensor to Monitor Concentration Ratio of Nitrogen and Oxygen in a Cryogenic Mixture

A spontaneous Raman scattering optical fiber sensor is developed for a specific need of NASA/SSC for long-term detection and monitoring of the quality of liquid oxygen (LOX) in the delivery line during ground testing of rocket engines. The sensor performance was tested in the laboratory and with different excitation light sources. To evaluate the sensor performance with different excitation light sources for the LOX quality application, we have used the various mixtures of liquid oxygen and liquid nitrogen as samples. The study of the sensor performance shows that this sensor offers a great deal of flexibility and provides a cost effective solution for the application. However, an improved system response time is needed for the real-time, quantitative monitoring of the quality of cryogenic fluids in harsh environment.

Tiwari, Vidhu S.↗

System and method for large-area pulsed laser melting of metallic powder in a laser powder bed fusion application

The present disclosure relates to systems and methods for performing large area laser powder bed fusion (LBPF) to form a plurality of layers of a 3D part in a layer-by-layer fashion using meltable powder particles. In one implementation the system makes use of a first light source, which may be a diode laser subsystem, for generating a first light pulse of a first duration. The first light is used to preheat a substrate underneath a new layer of powder particles, wherein the substrate is formed from a previously fused quantity of the powder particles. A second light source, which may be a pulse laser, generates a second light pulse subsequent to the first light pulse. The second light pulse has a second duration shorter than the first duration by a factor of at least about 10, and fully melts the new layer of powder particles in addition to the substrate, to achieve a smooth printed layer. The wavelength of the first light pulse also differs from a wavelength of the second light pulse.

Khairallah, Saad A.↗

A theory of photometric stereo for a class of diffuse non-Lambertian surfaces

A theory of photometric stereo is proposed for a large class of non-Lambertian reflectance maps. The authors review the different reflectance maps proposed in the literature for modeling reflection from real-world surfaces. From this, they obtain a mathematical class of reflectance maps to which the maps belong. They show that three lights can be sufficient for a unique inversion of the photometric stereo equation for the entire class of reflectance maps. They also obtain a constraint on the positions of light sources for obtaining this solution. They investigate the sufficiency of three light sources to estimate the surface normal and the illuminant strength. The issue of completeness of reconstruction is addressed. They shown that if k lights are sufficient for a unique inversion, 2k lights are necessary for a complete inversion.

Tagare, Hemant D.↗

Facility Designed and Built to Investigate the Combined Effects of Contaminant and Atomic Oxygen on a Light-Transmitting Surface

A need exists to investigate changes in the transparency of a light-transmitting surface during simultaneous exposure to a contaminant and an atomic oxygen (AO) flux. This mechanism may be responsible for the degradation of the light-transmitting surfaces of both photovoltaic cells and photodiodes currently in use on many low-Earth-orbit spacecraft. To address this need, researchers from the Electro-Physics Branch of the NASA Glenn Research Center at Lewis Field built such a test system within their AO beam facility. This facility produces an effective AO flux of 1.4 10(exp 16) atoms/sq cm/sec and contains a three-axis positioning system that provides the motion capability necessary for test operations. During testing, a target surface is held directly within the AO beam and close to two contaminant effusion cells. The effusion cells are shielded from the AO beam, and the outgassing contaminant is constrained to move across the target surface when heat is applied to either of the reservoirs. A light source is periodically moved over the target surface, and the transmitted light intensity is checked with a photodiode located below the target. This light source is also periodically checked with a separate photodiode, which is protected from contamination and AO exposure, to allow adjustments necessary to maintain a consistent light intensity.

Sechkar, Edward A.↗

Demonstration of Complete Recycling Processes of Reversible Epoxies Using Solar Energy Conversion

Reversible epoxies using the Diels–Alder chemistry enables recycling processes through depolymerizing the polymer at higher temperature and then repolymerizing upon cooling. Compared to conventional bulk heating, photothermal heating can save time and resource and, consequently, reduce costs to reach an elevated temperature for recycling processes of the reversible epoxies. In previous studies, self‐healing of cracks and reattachments of two broken pieces have been presented using a laser; however, recycling of a sample as a whole is not feasible by using such a point light source. Herein, complete recycling processes are demonstrated utilizing an area light source, i.e., sunlight. Reversible epoxies are incorporated with carbon black and refractory plasmonic titanium nitride nanoparticles (NPs). Under concentrated (10 times) sunlight, they can generate sufficient heat (≈140 °C) to completely liquefy, reprocess, and reshape the samples multiple times. Recycling processes are validated by evaluation of mechanical properties for each cycle. Using an integrated experimental and theoretical approach, photothermal performance is investigated in terms of the dispersion and loading of photothermal NPs in the matrix, as well as the sample thickness. In this study, an insight is provided into the design of polymer/photothermal nanomaterial composites which can be sustainably recycled using abundant solar energy.

14 SOLAR ENERGY↗

Fast dynamic aperture optimization with forward-reversal integration

A fast dynamic aperture (DA) optimization method for storage rings has been developed through the use of reversal integration. Even if dynamical systems have an exact reversal symmetry, a numerical forward integration differs from its reversal. For a chaotic trajectory, cumulative round-off errors are scaled, which results in an exponential growth on the difference. The exponential effect is a generic chaos indicator which represents the sensitivity of the chaotic motion to its initial condition. The chaos indicator of the charged particle motion can be obtained by comparing the forward integrations of particle trajectories with corresponding reversals, a.k.a. “backward integrations.” The indicator is observable even through short-term particle tracking simulations. Therefore, adopting it as an objective function could speed up optimization. Finally, the DA of the National Synchrotron Light Source II storage ring, and another test diffraction-limited light source ring, were optimized using this method for the purpose of demonstration.

43 PARTICLE ACCELERATORS↗

Evaluation of an LED Simulator for Single- and Multi-Junction PV Cell Performance Testing

We present the evaluation of a solar simulator comprising a Light Emitting Diode (LED) array as its light source. While multiple applications can be envisioned for such a light source, here we focus on its use for performance testing of solar cells at Standard Test Conditions. With this in mind, we present characterization of the spatial uniformity of the irradiance and its temporal stability as well as the spectral range and spectral class. For a multisource simulator, the spectral uniformity across the test plane should also be evaluated and we discuss a method for performing this evaluation that is well suited to a solar cell performance testing application. One major advantage of this simulator is the ability to easily adjust the spectral output as needed in multijunction PV cell measurements and we also discuss this application here.

LED↗

Advances in white-light optical signal processing

A technique that permits signal processing operations which can be carried out by white light source is described. The method performs signal processing that obeys the concept of coherent light rather than incoherent optics. Since the white light source contains all the color wavelengths of the visible light, the technique is very suitable for color signal processing.

Yu, F. T. S.↗