Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Light”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Visible Light Photoreduction of CO{sub 2} Using CdSe/Pt/TiO{sub 2} Heterostructured Catalysts

A series of CdSe quantum dot (QD)-sensitized TiO{sub 2} heterostructures have been synthesized, characterized, and tested for the photocatalytic reduction of CO{sub 2} in the presence of H{sub 2}O. Our results show that these heterostructured materials are capable of catalyzing the photoreduction of CO{sub 2} using visible light illumination (λ > 420 nm) only. The effect of removing surfactant caps from the CdSe QDs by annealing and using a hydrazine chemical treatment have also been investigated. The photocatalytic reduction process is followed using infrared spectroscopy to probe the gas-phase reactants and gas chromatography to detect the products. Gas chromatographic analysis shows that the primary reaction product is CH{sub 4}, with CH{sub 3}OH, H{sub 2}, and CO observed as secondary products. Typical yields of the gas-phase products after visible light illumination (λ>420 nm) were 48 ppm g{sup -1} h{sup -1} of CH{sub 4}, 3.3 ppm g{sup -1} h{sup -1} of CH{sub 3}OH (vapor), and trace amounts of CO and H{sub 2}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectral control of nonclassical light pulses using an integrated thin-film lithium niobate modulator

Abstract Manipulating the frequency and bandwidth of nonclassical light is essential for implementing frequency-encoded/multiplexed quantum computation, communication, and networking protocols, and for bridging spectral mismatch among various quantum systems. However, quantum spectral control requires a strong nonlinearity mediated by light, microwave, or acoustics, which is challenging to realize with high efficiency, low noise, and on an integrated chip. Here, we demonstrate both frequency shifting and bandwidth compression of heralded single-photon pulses using an integrated thin-film lithium niobate (TFLN) phase modulator. We achieve record-high electro-optic frequency shearing of telecom single photons over terahertz range (±641 GHz or ±5.2 nm), enabling high visibility quantum interference between frequency-nondegenerate photon pairs. We further operate the modulator as a time lens and demonstrate over eighteen-fold (6.55 nm to 0.35 nm) bandwidth compression of single photons. Our results showcase the viability and promise of on-chip quantum spectral control for scalable photonic quantum information processing.

Optics↗

Green syntheses of stable and efficient organic dyes for organic hybrid light-emitting diodes

Organic hybrid light-emitting diodes (hybrid-LEDs) employ organic dyes as light converters on top of commercial blue inorganic LEDs, replacing incumbent inorganic phosphor light converters synthesized from rare-earth and/or toxic metallic elements to optimize device environmental sustainability. Here, we present two naturally derived organic dyes for hybrid-LEDs, highlighting stability and efficiency enhancement based on a novel “acceptor–acceptor” molecular design. This “acceptor–acceptor” skeleton comprises theobromine and thiadiazole, two electron-withdrawing groups that lower energy levels and suppress photooxidation. This differentiates these dyes from the widely adopted “donor–acceptor” skeleton, where photooxidation is facilitated by the presence of electron-donating units. Simultaneously, sidechains on organic dyes used to enhance solution processability, crucial for film transparency, introduce an additional photooxidation pathway. With this “acceptor–acceptor” skeleton, the destabilization from sidechains was offset by the stability enhancement from the electronic effects in the backbone. Additionally, when blended within an industrial polymer, poly(styrene-butadiene-styrene) (SBS), their enhanced solubility enables the formation of highly transparent films, crucial for reducing scattering loss in LEDs. Furthermore, resultant dye-SBS films achieved photoluminescence quantum yields (PLQYs) of around 90% under ambient conditions. Taking advantage of their transparency and solution processability, we fabricated a waveguide with this theobromine-dye-SBS composite, which was subsequentially assembled into an edge-lit LED device of no glare and enhanced aesthetics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Light-activated microtubule-based two-dimensional active nematic

We assess the ability of two light responsive kinesin motor clusters to drive dynamics of microtubule-based active nematics: opto-K401, a processive motor, and opto-K365, a non-processive motor. Measurements reveal an order of magnitude improvement in the contrast of nematic flow speeds between maximally- and minimally-illuminated states for opto-K365 motors when compared to opto-K401 construct. For opto-K365 nematics, we characterize both the steady-state flow and defect density as a function of applied light. We also examine the transient behavior as the system switches between steady-states upon changes in light intensities. Although nematic flows reach a steady state within tens of seconds, the defect density exhibits transient behavior for up to 10 minutes, showing a separation between small-scale active flows and system-scale structural states. Furthermore, our work establishes an experimental platform that can exploit spatiotemporally-heterogeneous patterns of activity to generate targeted dynamical states.

42 ENGINEERING↗

Study of the one-way speed of light anisotropy with particle beams

Concepts of high precision studies of the one-way speed of light anisotropy are discussed. The high energy particle beam allows measurement of a one-way speed of light anisotropy (SOLA) via analysis of the beam momentum variation with sidereal phase without the use of synchronized clocks. High precision beam position monitors could provide accurate monitoring of the beam orbit and determination of the particle beam momentum with relative accuracy on the level of 10^-10, which corresponds to a limit on SOLA of 10^-18 with existing storage rings. A few additional versions of the experiment are also presented.

Wojtsekhowski, Bogdan B.↗

Effectiveness of Silicon as a Laser Sshinethrough Barrier for 351-nm Light

Many laser beams directly illuminate a spherical target in direct-drive inertial confinement fusion experiments, ionizing the outer surface and surrounding the target with a plasma containing an opaque critical surface. In the earliest stages of irradiation, before the plasma forms a critical-density surface, laser light can penetrate into the target. This “shinethrough” light can be sufficiently intense to undergo filamentation and damage the inside of the target, thereby seeding hydrodynamic instabilities. Laser shinethrough can be blocked by a thin coating of opaque material, such as, aluminum (Al). For cryogenic direct-drive targets, the shinethrough barrier material must also be compatible with cryogenic target fabrication procedures, which rules out Al layers since they would interfere with permeation filling and optical characterization of cryogenic targets. Silicon (Si) has been found to be a promising candidate for a direct-drive cryogenic target shinethrough barrier material. Several cryogenic targets have been coated with Si, successfully permeation filled with either deuterium (D2) or deuterium-tritium (DT), and subsequently layered and optically characterized. Various thicknesses of Si coatings have been applied to planar targets and tested under relevant irradiation conditions. Experiments have shown that 200 Å of Si is sufficient to protect targets from laser shinethrough.

Edgell, D H↗

A new adaptive light beam focusing principle for scanning light stimulation systems

In this article a novel principle to achieve optimal focusing conditions or rather the smallest possible beam diameter for scanning light stimulation systems is presented. It is based on the following methodology: First, a reference point on a camera sensor is introduced where optimal focusing conditions are adjusted and the distance between the light focusing optic and the reference point is determined using a laser displacement sensor. In a second step, this displacement sensor is used to map the topography of the sample under investigation. Finally, the actual measurement is conducted, using optimal focusing conditions in each measurement point at the sample surface, that are determined by the height difference between camera sensor and the sample topography. This principle is independent of the measurement values, the optical or electrical properties of the sample, the used light source, or the selected wavelength. Furthermore, the samples can be tilted, rough, bent, or of different surface materials. In the following the principle is implemented using an optical beam induced current system, but basically it can be applied to any other scanning light stimulation system. Measurements to demonstrate its operation are shown, using a polycrystalline silicon solar cell.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light focusing using epsilon-near-zero metamaterials

We present a strategy of focusing light using epsilon-near-zero metamaterials with embedded dielectric cylinder. The focusing mechanism is analytically investigated, and its accuracy is substantiated by rigorous full-wave simulations. It is found that the focusing intensity is highly depend on the embedded medium and its size, and the magnetic field amplitude of the focused beam itself can reach as high as 98.2 times the incident field. Owing to its versatility, the proposed light focusing system is sure to find applications in fields such as bio-sensing and in nonlinear optics.

36 MATERIALS SCIENCE↗

Visible light carrier generation in co-doped epitaxial titanate films

Perovskite titanates such as SrTiO{sub 3} (STO) exhibit a wide range of important functional properties, including ferroelectricity and excellent photocatalytic performance. The wide optical band gap of titanates limits their use in these applications; however, making them ill-suited for integration into solar energy harvesting technologies. Our recent work has shown that by doping STO with equal concentrations of La and Cr, we can enhance visible light absorption in epitaxial thin films while avoiding any compensating defects. In this work, we explore the optical properties of photoexcited carriers in these films. Using spectroscopic ellipsometry, we show that the Cr{sup 3+} dopants, which produce electronic states immediately above the top of the O 2p valence band in STO reduce the direct band gap of the material from 3.75 eV to 2.4–2.7 eV depending on doping levels. Transient reflectance spectroscopy measurements are in agreement with the observations from ellipsometry and confirm that optically generated carriers are present for longer than 2 ns. Finally, through photoelectrochemical methylene blue degradation measurements, we show that these co-doped films exhibit enhanced visible light photocatalysis when compared to pure STO.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Photocurrent response of B{sub 12}As{sub 2} crystals to blue light, and its temperature- dependent electrical characterizations

With the global shortage of {sup 3}He gas, researchers worldwide are looking for alternative materials for detecting neutrons. Among the candidate materials, semiconductors are attractive because of their light weight and ease in handling. Currently, we are looking into the suitability of boron arsenide (B{sub 12}As{sub 2}) for this specific application. As the first step in evaluating the material qualitatively, the photo-response of B{sub 12}As{sub 2} bulk crystals to light with different wavelengths was examined. The crystals showed photocurrent response to a band of 407- and 470- nm blue light. The maximum measured photoresponsivity and the photocurrent density at 0.7 V for 470 nm blue light at room temperature were 0.25 A ⋅ W{sup −1} and 2.47 mA ⋅ cm{sup −2}, respectively. In addition to photo current measurements, the electrical properties as a function of temperature (range: 50-320 K) were measured. Reliable data were obtained for the low-temperature I-V characteristics, the temperature dependence of dark current and its density, and the resistivity variations with temperature in B{sub 12}As{sub 2} bulk crystals. The experiments showed an exponential dependence on temperature for the dark current, current density, and resistivity; these three electrical parameters, respectively, had a variation of a few nA to μA, 1-100 μA ⋅ cm{sup −2} and 7.6x10{sup 5}-7.7x10{sup 3} Ω ⋅ cm, for temperature increasing from 50 K to 320 K. The results from this study reported the first photoresponse and demonstrated that B{sub 12}As{sub 2} is a potential candidate for thermal-neutron detectors.

36 MATERIALS SCIENCE↗

Solid polystyrene and deuterated polystyrene light output response to fast neutrons

The Neutron Imaging System has proven to be an important diagnostic in studying DT implosion characteristics at the National Ignition Facility. Here, the current system depends on a polystyrene scintillating fiber array, which detects fusion neutrons born in the DT hotspot as well as neutrons that have scattered to lower energies in the surrounding cold fuel. Increasing neutron yields at NIF, as well as a desire to resolve three-dimensional information about the fuel assembly, have provided the impetus to build and install two additional next-generation neutron imaging systems. We are currently investigating a novel neutron imaging system that will utilize a deuterated polystyrene (CD) fiber array instead of standard hydrogen-based polystyrene (CH). Studies of deuterated xylene or deuterated benzene liquid scintillator show an improvement in imaging resolution by a factor of two, but also a reduction in light output as compared to standard plastic. Tests of the relative light output of deuterated polystyrene and standard polystyrene were completed using 14 MeV fusion neutrons generated through implosions of deuterium-tritium filled capsules at the OMEGA laser facility. In addition, we collected data of the relative response of these two scintillators to a wide energy range of neutrons (1-800 MeV) at the Weapons Neutrons Research Facility. Results of these measurements are presented.

47 OTHER INSTRUMENTATION↗

A New Light for Berkeley Lab—the Advanced Light Source Upgrade

The Advanced Light Source Upgrade Project (ALS-U) will leverage multibend achromat technology to endow the ALS with revolutionary soft X-ray capabilities, and has recently received formal approval to proceed to the preliminary design phase. Soft X-rays are a critical diagnostic tool for enabling the understanding and control of heterogeneous, hierarchical functional materials and chemical synthesis platforms since they can reveal chemical, electronic, and magnetic properties with very high sensitivity. Although the ALS has a strong track record in soft X-ray science over the last 25 years, it, like most other existing storage-ring-based X-ray light sources, lacks the simultaneous combination of nanometer spatial resolution, diverse spectroscopic contrast, and broad temporal sensitivity required to image the location of molecules, ions, and electrons, and to measure how their components migrate and interact to support efficient function. The high coherent flux of the upgraded ALS willenable a suite of tools that encompass 3D nanoscale imaging with high spectral sensitivity over broad space and time scales, dramatically amplifying the already high impact of ALS soft X-ray spectroscopies. Relative to many other synchrotron light source upgrade projects or new facilities being built today, the upgraded ALS will operate at a low electron-beam energy of 2 GeV and a high current of 500 mA, and is optimized for soft X-rays. Its soft X-ray coherent flux will be orders of magnitude higher than that of the existing ALS and beyond the coherent flux of any storage-ring-based light source operating, under construction, or currently planned. In total, the upgraded facility will provide an unprecedented combination of high stability, quasi-continuous radiation, and the highest possible coherent soft X-ray flux.

47 OTHER INSTRUMENTATION↗

Cosmological parameter uncertainties from SALT-II type Ia supernova light curve models

We use simulated type Ia supernova (SN Ia) samples, including both photometry and spectra, to perform the first direct validation of cosmology analysis using the SALT-II light curve model. This validation includes residuals from the light curve training process, systematic biases in SN Ia distance measurements, and a bias on the dark energy equation of state parameter w. Using the SN-analysis package SNANA, we simulate and analyze realistic samples corresponding to the data samples used in the SNLS3 analysis: ∼120 low-redshift (z < 0.1) SNe Ia, ∼255 Sloan Digital Sky Survey SNe Ia (z < 0.4), and ∼290 SNLS SNe Ia (z ≤ 1). To probe systematic uncertainties in detail, we vary the input spectral model, the model of intrinsic scatter, and the smoothing (i.e., regularization) parameters used during the SALT-II model training. Using realistic intrinsic scatter models results in a slight bias in the ultraviolet portion of the trained SALT-II model, and w biases (w {sub input} – w {sub recovered}) ranging from –0.005 ± 0.012 to –0.024 ± 0.010. These biases are indistinguishable from each other within the uncertainty; the average bias on w is –0.014 ± 0.007.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct detection of light “Ge-phobic” exothermic dark matter

We present comparisons of direct dark matter (DM) detection data for light WIMPs with exothermic scattering with nuclei (exoDM), both assuming the Standard Halo Model (SHM) and in a halo model — independent manner. Exothermic interactions favor light targets, thus reducing the importance of upper limits derived from xenon targets, the most restrictive of which is at present the LUX limit. In our SHM analysis the CDMS-II-Si and CoGeNT regions become allowed by these bounds, however the recent SuperCDMS limit rejects both regions for exoDM with isospin-conserving couplings. An isospin-violating coupling of the exoDM, in particular one with a neutron to proton coupling ratio of −0.8 (which we call “Ge-phobic”), maximally reduces the DM coupling to germanium and allows the CDMS-II-Si region to become compatible with all bounds. This is also clearly shown in our halo-independent analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

59Co and 75As NMR Investigation of the Lightly Doped Ba[Fe(1-x)Co(x)]2As2 (x =0.02, 0.04)

We investigate the electronic properties of Ba[Fe(1-x)Co(x)]2As2 (x =0.02, 0.04) in the lightly electron-doped regime by 59Co and 75As NMR. We demonstrate that Co doping significantly suppresses the magnetic ordering temperature to the SDW state, T_{SDW}. Furthermore, ordered moments below T_{SDW} exhibit large distribution. Strong spin fluctuations remain even below T_{SDW}, persisting all the way down to 4.2 K. We find no signature of additional freezing of spin degrees of freedom unlike the case of the lightly hole-doped stripe phase of the cuprates.

36 MATERIALS SCIENCE↗

Hadronic structure on the light front. VIII. Light scalar and vector mesons

We use the QCD instanton vacuum model to discuss the emergence of the light scalar and vector mesons on the light front. We take into account both the instanton and anti-instanton single and molecular interactions on the light quarks, in the form of nonlocal effective interactions. Although the molecular induced interactions are suppressed by a power of the packing fraction, they are still sufficient to bind the vector mesons, while keeping most of the scalar spectrum relatively unchanged. We explicitly derive the light front distribution amplitudes and partonic functions for the scalar and vector mesons, and compare them after pertinent QCD evolution, to the available empirical and lattice measured counterparts. The Dirac electric form factors for both the pion and ρ meson are derived, and shown to compare well with current data. Published by the American Physical Society 2024

Astronomy & Astrophysics↗