Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LOSS CONE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Technical Note: Suppression of artifacts arising from simultaneous cone-beam imaging and RF transponder tracking in prostate radiotherapy

Purpose: Artifacts in treatment-room cone-beam reconstructions have been observed at the authors' center when cone-beam acquisition is simultaneous with radio frequency (RF) transponder tracking using the Calypso 4D system (Calypso Medical, Seattle, WA). These artifacts manifest as CT-number modulations and increased CT-noise. The authors present a method for the suppression of the artifacts. Methods: The authors propose a three-stage postprocessing technique that can be applied to image volumes previously reconstructed by a cone-beam system. The stages are (1) segmentation of voxels into air, soft-tissue, and bone; (2) application of a 2D spatial-filter in the axial plane to the soft-tissue voxels; and (3) normalization to remove streaking along the axial-direction. The algorithm was tested on patient data acquired with Synergy XVI cone-beam CT systems (Elekta, Crawley, United Kingdom). Results: The computational demands of the suggested correction are small, taking less than 15 s per cone-beam reconstruction on a desktop PC. For a moderate loss of spatial-resolution, the artifacts are strongly suppressed and low-contrast visibility is improved. Conclusions: The correction technique proposed is fast and effective in removing the artifacts caused by simultaneous cone-beam imaging and RF-transponder tracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Effect of Significant Tumor Reduction on the Dose Distribution in Intensity Modulated Radiation Therapy for Head-And-Neck Cancer: A Case Study

We present a unique case in which a patient with significant tissue loss was monitored for dosimetric changes using weekly cone beam computed tomography (CBCT) scans. A previously treated nasopharynx patient presented with a large, exophytic, recurrent left neck mass. The patient underwent re-irradiation to 70 Gy using intensity modulated radiation therapy (IMRT) with shielding blocks over the spinal cord and brain stem. Weekly CBCT scans were acquired during treatment. Target contours and treatment fields were then transferred from the original treatment planning computed tomography (CT) to the CBCT scans and dose calculations were performed on all CBCT scans and compared to the planning doses. In addition, a 'research' treatment plan was created that assumed the patient had not been previously treated, and the above analysis was repeated. Finally, to remove the effects of setup error, the outer contours of 2 CBCT scans with significant tumor reductions were transferred to the planning scan and dose in the planning scan was recalculated. Planning treatment volume (PTV) decreased 45% during treatment. Spinal cord D05 differed from the planned value by 3.5 {+-} 9.8% (average + standard deviation). Mean dose to the oral cavity and D05 of the mandible differed from the planned value by 0.9 {+-} 2.1% and 0.6 {+-} 1.5%, respectively. Results for the research plan were comparable. Target coverage did not change appreciably (-0.2 {+-} 2.5%). When the planning scan was recalculated with the reduced outer contour from the CBCT, spinal cord D05 decreased slightly due to the reduction in scattered dose. Weekly imaging provided us the unique opportunity to use different methods to examine the dosimetric effects of an unusually large loss of tissue. We did not see that tissue loss alone resulted in a significant effect on the dose delivered to the spinal cord for this case, as most fluctuation was due to setup error. In the IGRT era, delivered dose distributions can be more readily determined during treatment, and this information can be useful in deciding whether replanning is necessary.

61 RADIATION PROTECTION AND DOSIMETRY↗

Interplaying mechanisms behind single inclusive jet suppression in heavy-ion collisions

The suppression factor for single inclusive jets in Pb + Pb collisions at the Large Hadron Collider (LHC) has a weak dependence on the transverse momentum $p_T$ and remains almost the same at two colliding energies, $\sqrt{s}$ = 2.76 and 5.02 TeV, though the central rapidity density of bulk hadrons increases by about 20%. Here, this phenomenon is investigated within the linear Boltzmann transport (LBT) model, which includes elastic and inelastic processes based on perturbative QCD for both jet shower and recoil medium partons as they propagate through a quark-gluon plasma (QGP). With the dynamic evolution of the QGP given by the 3 + 1 D CLVisc hydrodynamic model with event-by-event fully fluctuating initial conditions, single inclusive jet suppression in Pb + Pb collisions from LBT agrees well with experimental data. The weak $ \sqrt{s} $ and $p_T$ dependence of the jet suppression factor at LHC are found to result directly from the $ \sqrt{s} $ dependence of the initial jet $p_T$ spectra and slow $p_T$ dependence of the jet energy loss. Contributions from jet-induced medium response, influence of radial expansion, both of which depend on jet-cone size, and jet flavor composition all conjoin to give a slow $p_T$ dependence of jet energy loss and the single jet suppression factor R AA , their dependence on $\sqrt{s}$ , and jet-cone size. Single inclusive jet suppression at $\sqrt{s}$ = 200 GeV is also predicted that actually decreases slightly with p T in the $p_T$< 50 GeV/c range because of the steeper initial jet spectra though the $p_T$ dependence of the jet energy loss is weaker than that at LHC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Graphite ablation at high temperatures

Graphite ablation under high temperatures for large outer planets entry probes, correlating mass loss rates with surface temperatures and specimen nose cone radii

Dickey, R. R.↗

SU-E-T-162: Characterization of a New Oblong Cone for Use with the Intraoperative Mobetron Unit

Purpose: To evaluate the dosimetric characteristics of a new flat 7 cm x 12 cm oblong cone for intraoperative radiation therapy (IORT) procedures. Methods: Percent depth dose (PDD) curves and profile measurements at dose depths of D100, D90, D80, D50, and D30 were measured using a parallel-plate ion chamber and a 3-D water tank Blue phantom II (iba) for the three energies (6, 9, and 12 MeV) available with the new generation Mobetron 2000. In addition, PDD curves and profiles were made with Gafchromic EBT3 films in solid water phantom. H&D curves were created for each energy for absolute calibration. The films were analyzed using the RIT image analysis software and then compared with the ion chamber results. Output values were obtained by normalizing the dose/MU at D100 at the clinical axis of the oblong cone by the dose/MU at D100 for the flat 10cm cylindrical standard cone using ion chamber measurements. Results: Ion chamber results show that the PDDs from the flat oblong cone, at the clinical axis, match with the PDDs for its “cylindrical brother” 7cm flat cone. These PDDs are comparable with those from the 10cm standard cone. The D100 coincides for all three energies. The cone output factors for the oblong cone are 1.07 for all energies. Ion chamber profiles measurements and film analysis show that the use of flat oblong cone with the 6 and 9 MeV energies Result in horns of approximately 12% and 8%, respectively. Conversely, 12 MeV profiles show loss of flatness near the field edge. Conclusion: The potential advantage of the oblong cones is the elimination of the well-known difficulties of electron field matching, both dosimetrically and in clinical setup.

60 APPLIED LIFE SCIENCES↗

Evaluation of the OSC-TV iterative reconstruction algorithm for cone-beam optical CT

Purpose: The present work evaluates an iterative reconstruction approach, namely, the ordered subsets convex (OSC) algorithm with regularization via total variation (TV) minimization in the field of cone-beam optical computed tomography (optical CT). One of the uses of optical CT is gel-based 3D dosimetry for radiation therapy, where it is employed to map dose distributions in radiosensitive gels. Model-based iterative reconstruction may improve optical CT image quality and contribute to a wider use of optical CT in clinical gel dosimetry. Methods: This algorithm was evaluated using experimental data acquired by a cone-beam optical CT system, as well as complementary numerical simulations. A fast GPU implementation of OSC-TV was used to achieve reconstruction times comparable to those of conventional filtered backprojection. Images obtained via OSC-TV were compared with the corresponding filtered backprojections. Spatial resolution and uniformity phantoms were scanned and respective reconstructions were subject to evaluation of the modulation transfer function, image uniformity, and accuracy. The artifacts due to refraction and total signal loss from opaque objects were also studied. Results: The cone-beam optical CT data reconstructions showed that OSC-TV outperforms filtered backprojection in terms of image quality, thanks to a model-based simulation of the photon attenuation process. It was shown to significantly improve the image spatial resolution and reduce image noise. The accuracy of the estimation of linear attenuation coefficients remained similar to that obtained via filtered backprojection. Certain image artifacts due to opaque objects were reduced. Nevertheless, the common artifact due to the gel container walls could not be eliminated. Conclusions: The use of iterative reconstruction improves cone-beam optical CT image quality in many ways. The comparisons between OSC-TV and filtered backprojection presented in this paper demonstrate that OSC-TV can potentially improve the rendering of spatial features and reduce cone-beam optical CT artifacts.

60 APPLIED LIFE SCIENCES↗

Specular reflections (“glint”) of the inner beams in a gas-filled cylindrical hohlraum

Herein we report on the experimental measurement of specular reflection (“glint”) of laser beams off the hohlraum wall in inertial confinement fusion experiments at the National Ignition Facility. In a hohlraum, glinted light can escape the opposite laser entrance hole of the hohlraum and is a potential laser energy loss mechanism. The total measured glint on the inner cones of beams is measured to be less than 8 TW (when using the full National Ignition Facility laser), which is <2% of incident peak power. The simulated x-ray flux exceeds the measurement by 10%–20%, and glinted laser light is unable to account for this discrepancy. Similar inner beam glint was measured for ρ = 0.3 and 0.6 mg/cc gas fill hohlraums, but no glint was detected for 1.2 mg/cc densities. Inner beam glint is dominated by the lowest angle 21.5 beams within a 23.5 quad, and it is at most 30% sensitive to different quad polarization arrangements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Final Report for Project DE-SC0006958: "An Investigation of the Effects of magnetic Fields and Collisionality on Shock Formation in Radiatively Cooled Plasma Flows"

We have developed a new experimental platform to study bow-shock formation in plasma flows generated using an inverse wire array z-pinch. We have made significant progress on the analysis of both hydrodynamic and magnetized shocks using this system. The hydrodynamic experiments show formation of a well-defined Mach cone, and highly localized shock strong associated with radiative losses and rapidly cooling over the shock. Magnetized shocks show that the balance of magnetic and ram pressures dominate the evolution of the shock region, generating a low plasma beta void around the target. Manuscripts are in preparation for publication on both these topics. We have also published the development of a novel diagnostic method which allow recovery of interferometry and self-emission data along the same line of sight. Finally, we have carried out work to integrate a kinetic routine with the 3D MHD code Gorgon, however it remains to complete this process. Both undergraduate and graduate students have been involved in both the experimental work and publications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Why heavy and light quarks radiate energy with similar rates

The dead-cone effect has been predicted to reduce the magnitude of energy loss and jet quenching for heavy flavors produced with large p{sub T} in heavy-ion collisions. On the contrary, data from the Relativistic Heavy Ion Collider demonstrate a strong suppression of high-p{sub T} electrons from charm and bottom decays. We show that vacuum radiation of a highly virtual quark produced at high p{sub T} with a stripped-off color field develops a much wider dead cone, which screens the one related to the quark mass. Lacking the field, gluons cannot be radiated within this cone until the color field is regenerated and the quark virtuality cools down to the scale of the order of the quark mass. However, this takes longer than is essential for the observed jet quenching, leading to similar nuclear effects for the light and charm quark jets. Open beauty is expected to radiate much less within the p{sub T} range studied so far in heavy-ion collisions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Causal propagation of a charged spin 3/2 field in an external electromagnetic background

We present a Lagrangian for a massive, charged spin 3/2 field in a constant external electromagnetic background, which correctly propagates only physical degrees of freedom inside the light cone. The Velo-Zwanziger acausality and other pathologies such as loss of hyperbolicity or the appearance of unphysical degrees of freedom are avoided by a judicious choice of nonminimal couplings. No additional fields or equations besides the spin 3/2 ones are needed to solve the problem.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

WE-DE-207B-10: Library-Based X-Ray Scatter Correction for Dedicated Cone-Beam Breast CT: Clinical Validation

Purpose: Scatter contamination is detrimental to image quality in dedicated cone-beam breast CT (CBBCT), resulting in cupping artifacts and loss of contrast in reconstructed images. Such effects impede visualization of breast lesions and the quantitative accuracy. Previously, we proposed a library-based software approach to suppress scatter on CBBCT images. In this work, we quantify the efficacy and stability of this approach using datasets from 15 human subjects. Methods: A pre-computed scatter library is generated using Monte Carlo simulations for semi-ellipsoid breast models and homogeneous fibroglandular/adipose tissue mixture encompassing the range reported in literature. Projection datasets from 15 human subjects that cover 95 percentile of breast dimensions and fibroglandular volume fraction were included in the analysis. Our investigations indicate that it is sufficient to consider the breast dimensions alone and variation in fibroglandular fraction does not significantly affect the scatter-to-primary ratio. The breast diameter is measured from a first-pass reconstruction; the appropriate scatter distribution is selected from the library; and, deformed by considering the discrepancy in total projection intensity between the clinical dataset and the simulated semi-ellipsoidal breast. The deformed scatter-distribution is subtracted from the measured projections for scatter correction. Spatial non-uniformity (SNU) and contrast-to-noise ratio (CNR) were used as quantitative metrics to evaluate the results. Results: On the 15 patient cases, our method reduced the overall image spatial non-uniformity (SNU) from 7.14%±2.94% (mean ± standard deviation) to 2.47%±0.68% in coronal view and from 10.14%±4.1% to 3.02% ±1.26% in sagittal view. The average contrast to noise ratio (CNR) improved by a factor of 1.49±0.40 in coronal view and by 2.12±1.54 in sagittal view. Conclusion: We demonstrate the robustness and effectiveness of a library-based scatter correction method using patient datasets with large variability in breast dimensions and composition. The high computational efficiency and simplicity in implementation make this attractive for clinical implementation. Supported partly by NIH R21EB019597, R21CA134128 and R01CA195512.The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.

60 APPLIED LIFE SCIENCES↗

Introduction of a novel ultrahigh sensitivity collimator for brain SPECT imaging

Purpose: Noise levels of brain SPECT images are highest in central regions, due to preferential attenuation of photons emitted from deep structures. To address this problem, the authors have designed a novel collimator for brain SPECT imaging that yields greatly increased sensitivity near the center of the brain without loss of resolution. This hybrid collimator consisted of ultrashort cone-beam holes in the central regions and slant-holes in the periphery (USCB). We evaluated this collimator for quantitative brain imaging tasks. Methods: Owing to the uniqueness of the USCB collimation, the hole pattern required substantial variations in collimator parameters. To utilize the lead-casting technique, the authors designed two supporting plates to position about 37 000 hexagonal, slightly tapered pins. The holes in the supporting plates were modeled to yield the desired focal length, hole length, and septal thickness. To determine the properties of the manufactured collimator and to compute the system matrix, the authors prepared an array of point sources that covered the entire detector area. Each point source contained 32 μCi of Tc-99m at the first scan time. The array was imaged for 5 min at each of the 64 shifted locations to yield a 2-mm sampling distance, and hole parameters were calculated. The sensitivity was also measured using a point source placed along the central ray at several distances from the collimator face. High-count projection data from a five-compartment brain phantom were acquired with the three collimators on a dual-head SPECT/CT system. The authors calculated Cramer-Rao bounds on the precision of estimates of striatal and background activity concentration. In order to assess the new collimation system to detect changes in striatal activity, the authors evaluated the precision of measuring a 5% decrease in right putamen activity. The authors also reconstructed images of projection data obtained by summing data from the individual phantom compartments. Results: The sensitivity of the novel cone-beam collimator varied with distance from the detector face; it was higher than that of the fan-beam collimator by factors ranging from 2.7 to 162. Examination of the projections of the point sources revealed that only a few holes were distorted or partially blocked, indicating that the intensive manual fabrication process was very successful. Better reconstructed phantom images were obtained from the USCB+FAN collimator pair than from either LEHR or FAN collimation. For the left caudate, located near the center of the brain, the detected counts were 9.8 (8.3) times higher for UCSB compared with LEHR (FAN), averaged over 60 views. The task-specific SNR for detecting a 5% decrease in putamen uptake was 7.4 for USCB and 3.2 for LEHR. Conclusions: The authors have designed and manufactured a novel collimator for brain SPECT imaging. The sensitivity is much higher than that of a fan-beam collimator. Because of differences between the manufactured collimator and its design, reconstruction of the data requires a measured system matrix. The authors have demonstrated the potential of USCB collimation for improved precision in estimating striatal uptake. The novel collimator may be useful for early detection of Parkinson’s disease, and for monitoring therapy response and disease progression.

60 APPLIED LIFE SCIENCES↗

Transmitter and receiver antenna gain analysis for laser radar and communication systems

A comprehensive and fairly self-contained study of centrally obscured optical transmitting and receiving antennas is presented and is intended for use by the laser radar and communication systems designer. The material is presented in a format which allows the rapid and accurate evaluation of antenna gain. The Fresnel approximation to scalar wave theory is reviewed and the antenna analysis proceeds in terms of the power gain. Conventional range equations may then be used to calculate the power budget. The transmitter calculations, resulting in near and far field antenna gain patterns, assumes the antenna is illuminated by a laser operating in the fundamental cavity mode. A simple equation is derived for matching the incident source distribution to a general antenna configuration for maximum on-axis gain. An interpretation of the resultant gain curves allows a number of auxiliary design curves to be drawn which display the losses in antenna gain due to pointing errors and the cone angle of the outgoing beam as a function of antenna size and central obscuration. The use of telescope defocusing as an approach to spreading the beam for target acquisition is compared to some alternate methods.

Klein, B. J.↗

Optical antenna gain. I - Transmitting antennas

The gain of centrally obscured optical transmitting antennas is analyzed in detail. The calculations, resulting in near- and far-field antenna gain patterns, assume a circular antenna illuminated by a laser operating in the TEM-00 mode. A simple polynomial equation is derived for matching the incident source distribution to a general antenna configuration for maximum on-axis gain. An interpretation of the resultant gain curves allows a number of auxiliary design curves to be drawn that display the losses in antenna gain due to pointing errors and the cone angle of the beam in the far field as a function of antenna aperture size and its central obscuration. The results are presented in a series of graphs that allow the rapid and accurate evaluation of the antenna gain which may then be substituted into the conventional range equation.

Klein, B. J.↗

Investigating charm quark energy loss in medium with the nuclear modification factor of D 0 -tagged jets

The nuclear modification factor R AA of charm jets, identified by the presence of a D 0 meson among the jet constituents, has been measured for the first time in Pb–Pb collisions at a centre-of-mass energy per nucleon pair $\sqrt{s_{NN}} = 5.02$ TeV with the ALICE detector at the LHC. The D 0 mesons and their charge conjugates are reconstructed from the hadronic decay D 0 → K – π + . Jets are reconstructed from D 0 -meson candidates and charged particles using the anti-k T algorithm with jet resolution parameter R = 0.3, in the jet transverse momentum (p T ) range 5 < $p^{ch}_{T}$$^{jet}$ < 50 GeV/c and pseudorapidity |η ch jet| < 0.6. A hint of reduced suppression in the charm-jet R AA is observed in comparison to inclusive jets in central Pb–Pb collisions with a significance of about 2σ in 20 < $p^{ch}_{T}$$^{jet}$ < 50 GeV/c, suggesting the in-medium energy loss to depend on both the difference between quark and gluon coupling strength (Casimir colour-charge effect) and quark mass (dead-cone effect). The data are compared with model calculations that include mass effects in the in-medium energy loss. Several state-of-the-art models are consistent with the data, with the LIDO model providing the best description of the data in the common kinematic range of inclusive and D 0 -tagged jets, highlighting the role of mass effects in interpreting the results.

Acharya, S. (ORCID:0000000292135329)↗

Light-extraction enhancement in GaN-based light-emitting diodes using grade-refractive-index amorphous titanium oxide films with porous structures

Amorphous titanium oxide (a-TiO{sub x}:OH) films prepared by plasma-enhanced chemical-vapor deposition at 200 and 25 deg. C are in turn deposited onto the GaN-based light-emitting diode (LED) to enhance the associated light extraction efficiency. The refractive index, porosity, and photocatalytic effect of the deposited films are correlated strongly with the deposition temperatures. The efficiency is enhanced by a factor of {approx}1.31 over that of the uncoated LEDs and exhibited an excellent photocatalytic property after an external UV light irradiation. The increase in the light extraction is related to the reduction in the Fresnel transmission loss and the enhancement of the light scattering into the escape cone by using the graded-refractive-index a-TiO{sub x}:OH film with porous structures.

36 MATERIALS SCIENCE↗

Drag of heavy quarks in quark gluon plasma at energies available at the CERN Large Hadron Collider (LHC)

The drag and diffusion coefficients of charm and bottom quarks propagating through quark gluon plasma (QGP) have been evaluated for conditions relevant to nuclear collisions at the Large Hadron Collider (LHC). The dead cone and Landau-Pomeronchuk-Migdal (LPM) effects on radiative energy loss of heavy quarks have been considered. Both radiative and collisional processes of energy loss are included in the effective drag and diffusion coefficients. With these effective transport coefficients, we solve the Fokker-Plank (FP) equation for the heavy quarks executing Brownian motion in the QGP. The solution of the FP equation has been used to evaluate the nuclear suppression factor, R{sub AA}, for the nonphotonic single-electron spectra resulting from the semileptonic decays of hadrons containing charm and bottom quarks. The effects of mass on R{sub AA} have also been highlighted.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Classical strongly coupled quark-gluon plasma. VII. Energy loss

We use linear response analysis and the fluctuation-dissipation theorem to derive the energy loss of a heavy quark in the SU(2) classical Coulomb plasma in terms of the l=1 monopole and nonstatic structure factor. The result is valid for all Coulomb couplings {Gamma}=V/K, the ratio of the mean potential to kinetic energy. We use the Liouville equation in the collisionless limit to assess the SU(2) nonstatic structure factor. We find the energy loss to be strongly dependent on {Gamma}. In the liquid phase with {Gamma}{approx_equal}4, the energy loss is mostly metallic and soundless with neither a Cerenkov nor a Mach cone. Our analytical results compare favorably with the SU(2) molecular dynamics simulations at large momentum and for heavy quark masses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗