Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LASER OUTPUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Efficient Ho:LuLiF MOPA Laser Transmitter for Space Pathfinder Coherent Wind Lidar

Supported by NASA’s Earth Science Technology Office (ESTO), a new lidar transmitter system is developed under the Wind-Space Pathfinder coherent wind lidar project. It is an efficient Ho:LuLiF master oscillator power amplifier system (MOPA) that is capable of generating 15 watts power and 180 ns pulse width at 200 Hz PRF with excellent beam quality. The laser is injection seeded to provide stable single longitudinal frequency output. The laser beam polarization can be switched between “S” and “P” alternatively. Thus, the “S” and “P” beams can be directed to two separate telescopes at different directions to provide true horizontal wind measurement without a moving part in the lidar system. The laser power, pulse width and beam quality fulfill the space lidar system’s figure-of-merit (FOM) and measurement accuracy requirements.

Coherent Laser Radar↗

Lidar System for Airborne Measurement of Clouds and Aerosols

A lidar system for measuring optical properties of clouds and aerosols at three wavelengths is depicted. The laser transmitter is based on a Nd:YVO4 laser crystal pumped by light coupled to the crystal via optical fibers from laser diodes that are located away from the crystal to aid in dissipating the heat generated in the diodes and their drive circuits. The output of the Nd:YVO4 crystal has a wavelength of 1064 nm, and is made to pass through frequency-doubling and frequency-tripling crystals. As a result, the net laser output is a collinear superposition of beams at wavelengths of 1064, 532, and 355 nm. The laser operates at a pulse-repetition rate of 5 kHz, emitting per-pulse energies of 50 microJ at 1064 nm, 25 microJ at 532 nm and 50 microJ at 355 nm. An important feature of this system is an integrating sphere located between the laser output and the laser beam expander lenses. The integrating sphere collects light scattered from the lenses. Three energy-monitor detectors are located at ports inside the integrating sphere. Each of these detectors is equipped with filters such that the laser output energy is measured independently for each wavelength. The laser output energy is measured on each pulse to enable the most accurate calibration possible. The 1064-nm and 532-nm photodetectors are, more specifically, single photon-counting modules (SPCMs). When used at 1064 nm, these detectors have approximately 3% quantum efficiency and low thermal noise (fewer than 200 counts per second). When used at 532 nm, the SPCMs have quantum efficiency of about 60%. The photodetector for the 355-nm channel is a photon-counting photomultiplier tube having a quantum efficiency of about 20%. The use of photon-counting detectors is made feasible by the low laser pulse energy. The main advantage of photon-counting is ease of inversion of data without need for complicated calibration schemes like those necessary for analog detectors. The disadvantage of photon-counting detectors is that they inherently have narrow dynamic ranges. However, by using photon-counting detectors along with a high-repetition rate laser, it is possible to obtain wide dynamic range through accumulation of counts over many pulses.

McGill, Matthew↗

A dual-end-pumped Ho:YAG laser with a high energy output

We report a high energy output from a Ho:YAG oscillator resonantly double-end pumped by Tm:YLF lasers at room temperature. The maximum pulse energy of 52.5 mJ was achieved at a pulse repetition rate of 100Hz and a pulse duration of 35.2 ns, corresponding to a peak power of approximately 1.5 MW. The output wavelength was 2090.7 nm with beam quality factor M{sup 2} ∼ 1.2. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Free-flying experiment to measure the Schawlow-Townes linewidth limit of a 300 THz laser oscillator

Recent advances in laser diode-pumped solid state laser sources permit the design and testing of laser sources with linewidths that approach the Schawlow-Townes limit of 1 Hz/mW of output power. Laser diode pumped solid state ring oscillators have been operated with CW output power levels of 25 mW at electrical efficiencies that exceed 6 percent. These oscillators are expected to operate for lifetimes that approach those of the laser diode sources which is now approaching 20,000 hours. The efficiency and lifetime of these narrow linewidth laser sources will enable space measurements of gravity waves, remote sensing applications (including local range rate and measurements), and laser sources for frequency and time standards. A free-flight experiment, 'SUNLITE', is being designed to measure the linewidth of this all-solid-state laser system.

Byer, R. L.↗

High Output Maximum Efficiency Resonator (HOMER) Laser for NASA's Global Ecosystem Dynamics Investigation (GEDI) Lidar Mission

The Global Ecosystems Dynamics Investigation (GEDI) is a planned mission sending a LIDAR instrument to the International Space Station that will employ three NASA laser transmitters. This instrument will produce parallel tracks on the Earth's surface that will provide global 3D vegetation canopy measurements. To meet the mission goals a total of 5 High Output Maximum Efficiency Resonator lasers will to be built (1 ETU + 3 Flight + 1 spare) in-house at NASA-GSFC. This presentation will summarize the HOMER design, the testing the design has completed in the past, and the plans to successfully build the units needed for the GEDI mission.

soil↗

Metasurface quantum-cascade laser with electrically switchable polarization

Dynamic control of a laser’s output polarization state is desirable for applications in polarization sensitive imaging, spectroscopy, and ellipsometry. Using external elements to control the polarization state is a common approach. Less common and more challenging is directly switching the polarization state of a laser, which, however, has the potential to provide high switching speeds, compactness, and power efficiency. Here, we demonstrate a new approach to achieve direct and electrically controlled polarization switching of a semiconductor laser. This is enabled by integrating a polarization-sensitive metasurface with a semiconductor gain medium to selectively amplify a cavity mode with the designed polarization state, therefore leading to an output in the designed polarization. Here, the demonstration is for a terahertz quantum-cascade laser, which exhibits electrically controlled switching between two linear polarizations separated by 80°, while maintaining an excellent beam with a narrow divergence of ~3°×3° and a single-mode operation fixed at ~3.4 THz, combined with a peak power as high as 93 mW at a temperature of 77 K. The polarization-sensitive metasurface is composed of two interleaved arrays of surface-emitting antennas, all of which are loaded with quantum-cascade gain materials. Each array is designed to resonantly interact with one specific polarization; when electrical bias is selectively applied to the gain material in one array, selective amplification of one polarization occurs. The amplifying metasurface is used along with an output coupler reflector to build a vertical-external-cavity surface-emitting laser whose output polarization state can be switched solely electrically. In conclusion, this work demonstrates the potential of exploiting amplifying polarization-sensitive metasurfaces to create lasers with desirable polarization states—a concept which is applicable beyond the terahertz and can potentially be applied to shorter wavelengths.

47 OTHER INSTRUMENTATION↗

Determination of Spatial Distribution of Air Pollution by Dye Laser Measurement of Differential Absorption of Elastic Backscatter

This paper presents the results of an analytical study of a lidar system which uses tunable organic dye lasers to accurately determine spatial distribution of molecular air pollutants. Also described will be experimental work to date on simultaneous multiwavelength output dye laser sources for this system. Basically the scheme determines the concentration of air pollutants by measuring the differential absorption of an (at least) two wavelength lidar signal elastically backscattered by the atmosphere. Only relative measurements of the backscattered intensity at each of the two wavelengths, one on and one off the resonance absorption of the pollutant in question, are required. The various parameters of the scheme are examined and the component elements required for a system of this type discussed, with emphasis on the dye laser source. Potential advantages of simultaneous multiwavelength outputs are described. The use of correlation spectroscopy in this context is examined. Comparisons are also made for the use of infrared probing wavelengths and sources instead of dye lasers. Estimates of the sensitivity and accuracy of a practical dye laser system of this type, made for specific pollutants, snow it to have inherent advantages over other schemes for determining pollutant spatial distribution.

Ahmed, S. A.↗

Method and system for communicating with a laser power driver

A system for controlling a plurality of laser diodes includes an optical transmitter coupled to the laser diode driver for each laser diode. An optical signal including bi-phase encoded data is provided to each laser diode driver. The optical signal includes current level and pulse duration information at which each of the diodes is to be driven. Upon receiving a trigger signal, the laser diode drivers operate the laser diodes using the current level and pulse duration information to output a laser beam.

47 OTHER INSTRUMENTATION↗

Experimental study of a modulated beam AlGaAs/GaAs diode amplifier operating in the highly saturated gain regime

The variation in the modulation parameters of an optical signal in a diode power amplifier has been studied experimentally. The experimental data obtained agree well with theory that takes into account nonlinear interaction between fields in the gain medium of a laser through inversion beating. It is shown that the dominant type of output signal modulation is phase modulation, whose depth depends on the amplitude – phase coupling coefficient of the gain medium of the amplifier and the nature of the modulation (the phase relationships between the spectral components) of the output signal. (lasers)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Seven-core fibre Raman laser with intercore coupling

This paper reports results of a study aimed at producing a Raman fibre laser based on a multicore fibre with high-reflectivity fibre Bragg gratings inscribed in its peripheral cores using femtosecond laser pulses. We present spectral and power characteristics of a Raman laser whose output power at a wavelength of 1090 nm is 2.5 W. The laser emission linewidth has been shown to decrease as a result of the reduction in nonlinear effects owing to the larger effective mode area in the multicore fibre in comparison with a standard single-mode fibre Raman laser. (paper)

36 MATERIALS SCIENCE↗

Cold cathodes for sealed off CO2 lasers

Experimental results of a group of theoretically selected cold cathode materials are presented. These tests indicate Ag-CuO, Cu, and Pt-Cu as three new cold cathode materials for sealed-off CO2 lasers. The power output of a test laser with an Ag-CuO cathode and a gas volume of only 50 cu cm varied from 0.72 W to 1.1 W at 3000 hours and still yields 0.88 W after 8000 hours. Gas discharge tubes with Cu cathodes and a volume of 25 cu cm yield lifetimes in excess of 10,000 hours. Gas analysis results, obtained from a similar tube over a period of 3000 hours, look most promising. A Pt-Cu alloy cathode shows an extremely promising V-I characteristic over a period of 2800 hours.

Hochuli, U. E.↗

The recording and processing of pulsed laser diode spectra

A system capable of measuring and statistically analyzing wavelength and intensity fluctuations in pulsed laser diode output beams has been developed. The snapshot wavelength-intensity performance of laser diodes emitting discrete short-duration optical pulse is determined by isolating and recording individual pulses. Statistical processing of the resultant data generates information about the magnitude and/or frequency of occurrence of power variations or wavelength fluctuations in narrow optical bands. The system configuration along with plots depicting results based on measurements taken for various laser diodes are presented.

Fuhr, Peter L.↗

A rate equation approach to gain saturation effects in laser mode calculations

Space exploration and research require large amounts of power. Solar pumped laser systems have been shown to have the potential for meeting the performance requirements necessary for power transmission in space. The successful design of laser systems for these applications will depend, in part, on having a clear understanding of the development of the dynamical processes in the laser cavity and on the effects that changes in physical and design parameters have on laser performance. In particular, it is necessary to know the amplitude and phase distributions of the laser beam at the output aperture when steady state operation is achieved in order to determine the far-field power distribution. The output from the laser will depend on the active medium, the optical environment of the active material and on the gain distribution in the active region as laser action builds up and reaches steady state. An important component in the design process will be a realistic model of the active laser cavity. A computer model of the laser cavity, based on Huygens' principle was developed. The code calculates the amplitude and phase of an optical wave reflected back and forth between the mirrors of a laser cavity. The original code assumes a gain distribution which does not change with the buildup of oscillations in the cavity. A step in the direction of realism is the inclusion of a saturable gain medium in the cavity. The objective is to incorporate saturation effects into the existing computer model.

Roberts, Lila F.↗

Diode Laser Velocity Measurements by Modulated Filtered Rayleigh Scattering

The ability of solid-state lasers to be tuned in operating frequency at MHz rates by input current modulation, while maintaining a relatively narrow line-width, has made them useful for spectroscopic measurements. Their other advantages include low cost, reliability, durability, compact size, and modest power requirements, making them a good choice for a laser source in micro-gravity experiments in drop-towers and in flight. For their size, they are also very bright. In a filtered Rayleigh scattering (FRS) experiment, a diode laser can be used to scan across an atomic or molecular absorption line, generating large changes in transmission at the resonances for very small changes in frequency. The hyperfine structure components of atomic lines of alkali metal vapors are closely spaced and very strong, which makes such atomic filters excellent candidates for sensitive Doppler shift detection and therefore for high-resolution velocimetry. In the work we describe here we use a Rubidium vapor filter, and work with the strong D(sub 2) transitions at 780 nm that are conveniently accessed by near infrared diode lasers. The low power output of infrared laser diodes is their primary drawback relative to other laser systems commonly used for velocimetry. However, the capability to modulate the laser frequency rapidly and continuously helps mitigate this. Using modulation spectroscopy and a heterodyne detection scheme with a lock-in amplifier, one can extract sub-microvolt signals occurring at a specific frequency from a background that is orders of magnitude stronger. The diode laser modulation is simply achieved by adding a small current modulation to the laser bias current. It may also be swept repetitively in wavelength using an additional lower frequency current ramp.

Mach, J. J.↗

Performance Testing of TRL4-6 LISA Laser System

The Laser Interferometer Space Antenna (LISA) is an ESA-led future mission to measure gravitational waves from astronomical sources in space. LISA has been adopted as a formal mission by ESA in January 2024, and is expected to become a formal project at NASA within 2024. The laser system (LS), which includes four laser heads (LH) each containing a laser optical module (LOM) and laser electronics module (LEM), a frequency reference system (FRS, optical frequency reference) and four power monitor detectors (PMON), is one of the three U.S. contributions to LISA from NASA. The Lasers and Electro-Optics Branch at NASA GSFC has been developing and managing the design of the LISA LS. Currently, the TRL (technology readiness level) of the NASA LISA laser system is transitioning from 4 to 6. TRL 4/5 LISA LOM was sent to ESA in early 2023 and has undergone optical performance testing. [1] By late summer of 2024, NASA plans to deliver the TRL 6 LOM to ESA for performance evaluation. Since the delivery of the TRL4/5 LOM to ESA, we have taken steps to advance the TRL of the overall LS and have also started end-to-end system level testing involving other subsystems. They include 1) optical performance test of TRL6 LOM and TRL 5 LEM under thermal cycling, 2) end-to-end test of the laser head (LH) and the GSE (ground support equipment) FRS, driven by TRL 4 FRS electronics (FRS-E) provided by Ball Aerospace, 3) end-to-end test of the laser head (LH) with the GSE phase meter system (PMS) provided by Albert Einstein Institute, and 4) optical performance test of the LH with the PMON subsystem developed by NASA. The FRS, PMS, and PMON provide necessary frequency stability, relative phase stability between lasers, and output power stability, respectively. Since they are all vital for the sensitive laser interferometry performed in LISA, it is necessary to perform these system level testing by combining the LH and other subsystems, and to prove the optical performance at an early stage during the LS development. Our recent work has successfully demonstrated the intra-connectivity of the LS, as well as critical external interface with the PMS to meet the LISA’s performance requirements. In this talk, we will report on the latest status of the LH testing and system level test. We will also discuss the paths to bring each subsystem to TRL6+ and plans for future system level testing.

LISA↗

Performance Assessment of the Mercury Laser Altimeter on MESSENGER from Mercury Orbit

The Mercury Laser Altimeter (MLA) is one of seven instruments on the MErcury Surface, Space ENvironment GEochemistry, and Ranging (MESSENGER) spacecraft,a mission in NASA's Discovery Program. MESSENGER was launched on August 3, 2004, and entered into orbit about Mercury on March 29, 2011. As of June 30, 2011 MLA started to collect science Measurements on March 29, 2011. As of June 30, 2011 MLA had accumulated about 3 million laser ranging measurements to the Mercury surface through one Mercury year, i.e ., one complete cycle of the spacecraft thermal environment. The average MLA laser output-pulse energy remained steady despite the harsh thermal environment, in which the laser bench temperature changed by as much as 15 C over a 35 min operating period . The laser beam-collimating telescope experienced a 30 C temperature swing over the same period, and the thermal cycling repeated every 12 hours. Nonetheless, MLA receiver optics appeared to be aligned and in focus throughout these temperature excursions. The maximum ranging distance of MLA was 1500 km at near-zero laser-beam incidence angle (and emission angle) and 600 km at 60 deg incidence angle. The MLA instrument performance in Mercury orbit has been consistent with the performance demonstrated during MESSENGER's Mercury flybys in January and October 2008 and during pre-launch testing. In addition to range measurements, MLA data are being used to estimate the surface reflectance of Mercury at 1064 nm wavelength, including regions of permanent shadow on the floors of polar craters. MLA also provides a measurement of the surface reflectance of sunlight at 1064 nm wavelength by its noise counters, for which output is a monotonic function of the background light.

Sun, Xiaoli↗

High-repetition-rate plate-electrode CO{sub 2} laser

A high-repetition-rate CO{sub 2} laser with the inductive-capacitive discharge stabilisation is studied for the first time. A multisection discharge gap of length 250 mm was formed by pairs of anode - cathode plates arranged in the form of a broken line. The width of the discharge region between each pair of the plates was {approx} 1.3 mm and height {approx} 12 mm. The cross section of the laser beam on the output mirror of the resonator was {approx} 6 x 8 mm. The maximum output energy of the laser using the CO{sub 2}:N{sub 2}:He=32:32:96 Torr mixture was 15.9 mJ, the lasing efficiency being 1.7%. For a relatively low gas flow rate of 19 m s{sup -1}, a CO{sub 2} laser pulse repetition rate of 3 kHz was achieved, the relative root-mean-square deviation of the pulse energy being within 5%. The average output power of the laser was {approx} 40 W. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Room temperature Dy:YLF laser operation at 4.34 micron

A Dy:YLF laser operating on the 6H11/2 to 6H13/2 transition at 4.34 micron and using a laser pumping scheme is reported. This pumping scheme is necessitated by the short upper-laser-level lifetime and the small effective stimulated-emission cross section. A suitable laser for this application is the Er:YLF laser operating at 1.73 micron. A simple model that approximates Dy:YLF laser performance well is presented. Results on laser performance, including a determination of the slope efficiency and threshold as a function of the output mirror reflectivity and a correlation of the pulse length with the laser output energy, are reported. Overall laser efficiency is found to be limited primarily by the ratio of the pump wavelength to laser output wavelength and the terminated four-level laser operation. Spectroscopic results, including the measurement of the absorption spectra and the lifetimes of both the upper- and lower-laser manifolds, are given.

Barnes, Norman P.↗