At least 343 records · Page 19

A Reliable, Cost-Effective Transformerless Medium-Voltage Inverter for Grid Integration of Combined Solar and Energy Storage

The goal of this project is to utilize an innovative holistic power electronic inverter design approach, which can leverage best-in-class silicon carbide (SiC) power modules, novel multi-level power electronic circuits, high frequency transformers, switching sequence based control and co-designed electro-thermal management methods, to realize a 300 kW transformerless medium-voltage (MV) inverter system. The system cost of the inverter is considered as a primary design objective alongside high power density, efficiency, low electromagnetic interference (EMI) and long lifespan. This design-oriented research activity, especially the proposed multi-objective optimization approach, will have broad impacts in holistic power electronic system design methods and in technologies that can be commercialized into a wide variety of wide bandgap power electronic applications.

14 SOLAR ENERGY↗

Power Solitons in Inverter-based Electric Energy Systems: Observation, Analysis and Implications

The discovery of an unfamiliar class of nonlinear energy waves in electric energy systems with dominating coupled inverter-based energy resources has been reported in a recent research project. Whenever there are slight but persistent differences among the reference signals used by inverters in pulse-width modulation, i.e., a weak group modulation instability condition, the unfamiliar energy waves appear, which contain not only the familiar frequency components present in electric power systems but also self-organized components in the ultra-high frequency region of the energy spectrum. These components are found to be exploding solitary waves with concentrated energy masses, hence we call them power solitons. This paper explains the work of the discovery reported, and the implications of the presence of power solitons for grid integration of inverter-based resources and power system protection.

14 SOLAR ENERGY↗

WBG-Enabled Current-Source Inverters for Integrated PM Motor Drives

This project takes advantage of the special capabilities of wide-bandgap (WBG) power semiconductor devices to develop innovative power electronics in the form of new current-source inverters (CSIs) that offer promising advantages over the dominant voltage-source inverter (VSI) topology. These CSIs, in turn, are extremely well-suited for integration into the housings of permanent magnet synchronous machines (PMSMs) to form integrated motor drives (IMDs). These new IMDs offer great promise for achieving major energy savings in a wide variety of applications that benefit from adjustable-speed control, including air conditioners, laundry appliances, industrial pumps/compressors, electric vehicles, and aerospace drives. WBG devices play a critical enabling role in these new IMDs because of their transformative features including much higher switching frequencies, lower losses, and compatibility with high operating temperatures. When incorporated into new CSI-based IMDs with PM machines, these WBG switches open the door to achieving major increases in power density, drive system efficiency, and fault tolerance, as well as substantial reductions in electromagnetic interference (EMI), manufacturing cost, and temperature-induced failures. The higher operating temperature capability of WBG devices compared to conventional silicon power devices is very appealing in IMD applications because the power electronics is mounted in close proximity to the motors which typically operate at temperatures well above the maximum limits of today’s silicon-based power electronics. This project has succeeded in designing, building, and testing multiple prototype versions of this CSI-IMD that have overcome many technical challenges in order to demonstrate the impressive performance improvements that can be achieved by the WBG-enabled CSI-IMD. The preliminary demo and bench-top versions of the current-source inverter developed during the first two years of the project were critical to laying the technical foundations for the 3 kW prototype CSI-IMD unit that was successfully built and tested during the third year. This prototype CSI-IMD unit was designed to fit within the housing envelope of the original permanent magnet (PM) synchronous machine in order to meet the demanding power density requirements that were set at the beginning of the project. All of the remaining performance objectives set for the prototype CSI-IMD unit including efficiency and electromagnetic interference (EMI) were also met. The last 18 months of the project were devoted to developing further enhancements of the WBG-enabled CSI-IMD technology that better prepare it for commercial production. More specifically, an upgraded version of the prototype CSI-IMD unit was developed that moved the power electronics into the same machine housing chamber as the motor, substantially raising the thermal demands on the power electronics. Tests with five different combinations of motor enclosure types and air cooling configurations were evaluated. Importantly, this work confirmed that the power electronics can deliver its full rated power and still operate well within its maximum temperature limits even for worst-case conditions when the housing is “totally-enclosed” without any openings for air to enter or exit the enclosure, and no blower/fan is provided to blow air over the outside surface of the enclosure. Reaching the full performance and energy-savings potential of this disruptive CSI-IMD motor drive technology is highly consistent with ARPA-E’s stated mission to “enhance the economic and energy security of the United States” while also supporting its commitment to “ensure that the U.S. maintains a technological lead in developing and deploying advanced energy technologies”. Follow-on projects are under way to explore the scalability of WBG-enabled CSI-IMD technology to 100 kW (peak) electric vehicle traction drives and fault-tolerant modular motor drives for future electrified aircraft propulsion applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Autonomous Inverter Controls for Resilient and Secure Grid Operation: Vector Control Design for Grid Forming

The project addresses both fundamental and practical challenges of GFM/GFL inverter control for the power grids with high inverter based resources (IBRs) penetration. A data- driven modeling technique is applied to accurately model dynamics of PWM inverters, including electromagnetic-transient (EMT). Systematic and integrative designs of grid- forming (GFM) and grid-following (GFL) primary controls are developed to guarantee system performance under either normal or abnormal operating conditions without violating constraints. This modeling and control framework provides black-start capability in case of an outage without relying on rotating generators, and its secondary control is also shown to enhance resilience against cyber-physical attacks.

14 SOLAR ENERGY↗

How Inverter-Based Resources (IBRs) Affect Protection Relay Elements

Inverter-based resources (IBRs) exhibit fault responses that differ significantly from those of synchronous generators, which can challenge the reliable operation of many commonly used power system protection elements. The fault response of IBRs is primarily influenced by their control algorithms and configurations, but the impact of these controls on protection relays is not yet fully understood. This presentation provides a comprehensive study of how IBR modeling and controls affect transmission line protection. Key modeling and control aspects include the DC source, inverter model, power level control, current control, and current limiting. The study reveals that certain aspects - such as the type of DC source (battery, PV, or hybrid), inverter model (average vs. switching), and power level control methods (PQ dispatch vs. Vdc-Vac control for grid-following IBRs, and droop vs. VSM for grid-forming IBRs) - do not significantly affect relay response. However, faster control loops, such as current control and current limiting, do influence the relay behavior. Additionally, the study explores the effects of other factors, including momentary cessation, operating points, fast/slow current responses, and grid strength on relay performance. Finally, the study offers recommendations for both IBR and protection engineers to improve IBR fault response and enhance the reliability of protection systems.

14 SOLAR ENERGY↗

UNIFI 1-MW Multi-Vendor Grid-Forming Inverter Test Updates

This presentation gives an update on UNIFI 1MW multi-vendor GFM inverter testing. The 1MW demo enters the last stage of the test, which is the integration test. And the main objectives of the integration tests include: 1) explore the interoperability of dispatching a future grid with energy mix (GFM inverters, GFL inverters and synchronous machine). The presentation highlights one example test, ROCOF, and summarizes all the key learning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Cryogenically-Cooled MW Inverter for Electric Aircraft Propulsion

Power electronic converter will be a key enabler for future electrified aircraft propulsion system. In aircraft applications, superconducting technologies such as superconducting motors and generators along with supporting power systems will grow in importance. Utilizing cryogenic cooling for power converter potentially can significantly improve the inverter system efficiency and specific power. This paper presents the cooling, hardware,and testing of a cryogenically-cooled MW inverter developed for electrified aircraft propulsion system. The 1 MVA full load testing with cryogenic cooling is demonstrated. The developed inverter system achieves 18 kVA/kg specific power and 99% efficiency, which provides a promising solution to achieve high power density and efficiency for future electrified aircraft propulsion system.

cryogenically-cooled inverter↗

Grid-Following Inverters and Synchronous Condensers: A Grid-Forming Pair?: Preprint

As power systems across the globe continue to achieve higher instantaneous penetrations of power electronic converterinterfaced renewable sources, the stability of these power systems is challenged because of the removal of synchronous machines, from which stability is traditionally derived. Although technological solutions to these stability challenges are on the horizon, such as the use of grid-forming inverters, they are not yet widely applied to larger power systems, which presents operational challenges for power systems achieving these high instantaneous penetrations today. An interim solution using existing technologies is to pair synchronous condensers with grid-following inverters, which might prolong the stability of an operating power system while synchronous generators are turned off during periods of high renewable energy availability. This work examines the transient stability of such a solution using PSCAD simulations of a two-bus system coupled to a variedlength transmission line, with a synchronous condenser at one bus and a grid-following inverter with grid-support functionality at the other. The system is exposed to load step, balanced fault, and unbalanced fault perturbations. It was found that this simple system returned to a steady state for transmission line lengths up to 125 km after 10% load steps, or a variety of fault types.

14 SOLAR ENERGY↗

Open-Source PSCAD Grid-Following and Grid-Forming Inverters and a Benchmark for Zero-Inertia Power System Simulations: Preprint

This paper presents open-source, flexible, and easily-scalable models of grid following and grid forming inverters for the PSCAD software platform. The models are intended for system integration studies, particularly stability analyses of power systems with high penetration of inverter-based generation. To verify the model functionality, they are implemented in a IEEE9-bus system in a zero-inertia operational scenario of 100% inverter-based generation. The models have been made available open source at the PyPSCAD NREL GitHub page.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Impact of Blockchain Delay on Grid-Tied Solar Inverter Performance: Preprint

This paper investigates the impact of the delay resulting from a blockchain, a promising security measure, for a hierarchical control system of inverters connected to the grid. The blockchain communication network is designed at the secondary control layer for resilience against cyberattacks. To represent the latency in the communication channel, a model is developed based on the complexity of the blockchain framework. Taking this model into account, this work evaluates the plant’s performance subject to communication delays, introduced by the blockchain, among the hierarchical control agents. In addition, this article considers an optimal model-based control strategy that performs the system’s internal control loop. The work shows that the blockchain’s delay size influences the convergence of the power supplied by the inverter to the reference at the point of common coupling. In the results section, real-time simulations on OPAL-RT are performed to test the resilience of two parallel inverters with increasing blockchain complexity.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Empirical Evaluation of GPS Clock Accuracy for Isochronous Droop-Based Inverters: Preprint

Grid-forming inverters rely upon an internal reference to regulate the grid’s voltage and frequency. Without a reliable reference, issues such as loss of synchronism, frequency instability, and unequal power sharing can occur. One proposed internal phase reference for grid-forming inverters is generated by the controller’s clock, but this is affected by nonidealities in the crystal oscillator leading to time drift in the phase reference. To improve the controller’s clock accuracy, the Global Positioning System (GPS) can be used to calibrate the internal clock. Previously, GPS-based clock calibration was explored theoretically and various methods were developed for mitigating frequency/phase drift at the power system level. This paper experimentally validates the direct performance of GPS time-calibration at the controller level and justifies its use in maintaining an accurate phase reference for droop-based grid-forming inverters.

clock drift↗

Inverters: A Pivotal Role in PV Generated Electricity

This presentation discusses the pivotal role inverters play in PV generated electricity. Topics include: the inverter as the center of the system--increasingly becoming the brain, with more features and capabilities (hybrid systems, safety, islanding, monitoring, etc.); increasing inverter-based generated electricity associated with many renewable energy sources; increased dependence for grid support and forming capability; communication within the grid and security increasingly required; increasing complexity leads to more chances to fail; as in most PV segments, there is cost reduction pressure, which makes it more challenging to keep the reliability high.

ENGINEERING,SOLAR ENERGY↗

Real-Time Testbed for Studying Cyberattacks and Defense in DER-integrated Smart Inverter Systems

In this paper, we propose a Hardware-in-the-Loop (HIL) simulation testbed suitable for the implementation and testing of realistic cyberattacks on grid-tied smart inverter systems integrated with Distributed Energy Resources (DER) that use the Distributed Network Protocol-3 (DNP3) protocol for communications between grid components. Specifically, our testbed combines a Real-Time Digital Simulator (RTDS) NovaCor device, outfitted with GNETx2 network interface cards, a gridtied DER topology implemented via the RTDS software package RSCAD, and a custom virtual network that emulates a man in the middle attacker. The Man-in-the-Middle (MITM) attacker captures DNP3 traffic and falsifies telemetry data in DNP3 packets to trigger unwarranted commands from a DNP3 controller that exploit smart inverter grid support functions. We choose DNP3 and implement grid support functions according to the IEEE Std. 1547-2018 mandated for the interconnection and interoperability of DER power systems with associated power components. Furthermore, we develop a protocol payload agnostic attack detection framework that leverages the round-trip time (RTT) anomalies between DNP3 requests and responses and can detect the presence of attacks without having to analyze the payload’s contents, while balancing trade-offs between false alarm counts, missed detections, and time to detection. To facilitate further research, we publicly release benign and attack network traffic exchanged between various sensors, controllers, and actuators in our grid-tied inverter testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber Threat Landscape and Engineering Mitigations for Grid Forming Inverters

This talk will cover the cyber threat landscape and engineering mitigations for grid forming (GFM) inverters. It will discuss the penetration of inverter-based resources (IBRs) in the United States and expected growth. It will then discuss the threat landscape for IBRs based on current and expected penetration. Real-world examples of cyber incidents affecting IBRs will be presented, concluding with an introduction to Cyber-Informed Engineering (CIE) and a guide on applying it to GFM inverters.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Stability Analysis of Power Systems with High Penetration of State-of-the-Art Inverter Technologies

With the increasing level of inverter-based resources (IBRs) in modern power systems, this paper presents a small-signal stability analysis for power systems comprising synchronous generators (SGs) and IBRs. Four types of inverter controls are considered: two grid-following (GFL) controls, with or without grid support functions; droop-based grid-forming (GFM) controls; and virtual oscillator control-based GFM. We also analyze the impact of STATCOM and synchronous condensers on system stability to assess their role in the energy mix transition. With the small-signal dynamic behavior of the major technologies modeled, this paper provides stringent stability assessments using the IEEE 39-bus benchmark system modified to simulate future power systems. The exhaustive test cases allow for (a) assessing the impacts of different types and controls of generation and supplementary grid assets, as well as system inertia and line impedance on grid stability, and (b) elucidating pathways for the stabilization of IBR-dominated power systems. The analysis also indicates that future power systems can be stabilized with only a fraction of the total generation as voltage sources without SGs or significant system inertia if they are well distributed. This study provides insights into future power system operations with a high level of IBRs that can also be used for planning and operation studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Masking of photovoltaic system performance problems by inverter clipping and other design and operational practices

We describe how performance problems can be “masked,” or not readily evident by several causes: by photovoltaic (PV) system configuration (such as the size of the PV array capacity relative to the size of the inverter and the resultant clipped operating mode); by instrumentation design, installation, and maintenance (such as a misaligned or dirty pyranometer); by contract clauses (when operational availability is transformed to contractual availability, which excludes many factors); and by identified management and operational practices (such as reporting on a portfolio of plants rather than individually). A simple method based on a duration curve is introduced to overcome shortcomings of Performance Ratio based on nameplate capacity and Performance Index based on hourly simulation when quantifying masking effects, and inverter clipping and pyranometer soiling are presented as two examples of the new method. With a better understanding of the non-transparency of masking issues, stakeholders can better interpret performance data and deliver improved AC and DC plant conditions through PV system operation and maintenance (O&M) for improved performance, reduced O&M costs, and a more consistently delivered, and reduced, levelized cost of energy (LCOE).

14 SOLAR ENERGY↗

Experimental Setup and Learning-Based AI Model for Developing Accurate PV Inverter Models [Slides]

The integration of power electronics-based interfaces presents challenges due to the absence of detailed models and the high computational complexity. Generic models used in system studies lack accuracy in capturing converter dynamics. This paper proposes a data-driven approach developed from experimental setup data. This approach enhances accuracy in photovoltaic inverter modeling. We used two types of PV inverters in the experiment. The recorded experimental data undergo processing through a machine learning model. Results from the model trained through machine learning is also presented.

14 SOLAR ENERGY↗