Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Integrated Energy System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Integrated Hydrogen Energy System Testing/Validation: Cooperative Research and Development Final Report, CRADA Number CRD-21-18272

Through the ARIES platform, this proposed project aims to bridge a gap and utilize the power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments and create open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid forming fuel cell inverters.

08 HYDROGEN↗

Development and test fuel cell powered on-site integrated total energy systems. Phase 3: Full-scale power plant development

The on-site system application analysis is summarized. Preparations were completed for the first test of a full-sized single cell. Emphasis of the methanol fuel processor development program shifted toward the use of commercial shell-and-tube heat exchangers. An improved method for predicting the carbon-monoxide tolerance of anode catalysts is described. Other stack support areas reported include improved ABA bipolar plate bonding technology, improved electrical measurement techniques for specification-testing of stack components, and anodic corrosion behavior of carbon materials.

Kaufman, A.↗

Develop and test fuel cell powered on-site integrated total energy system

Satisfactory performance is reported for the first 12-cell sub-stack of the 5 kW rebuild using improved ABA reactant distribution plates. Construction and test results are described for the first full-sized single-cell test (0.33 m x 0.56 m). Test duration was 450 hours. Plans are outlined for construction and testing of two methanol reformer units based on commercially-available shell-and-tube heat exchangers. A 5 kW-equivalent precursor and a 50 kW-equivalent prototype will be built. Supporting design and single-tube experimental data are presented. Stack support efforts are summarized on corrosion currents of graphite materials and acid-management of single-cell test facilities. Comparative properties are summarized for the two methanol/steam reforming catalysts evauated under Task V (now completed); T2107RS and C70-2RS.

Kaufman, A.↗

Develop and test fuel cell powered on-site integrated total energy systems. Phase 3: Full-scale power plant development

Satisfactory performance is reported for the first three 12-cell sub-stacks of the 5 kW stack rebuild. Early general conclusions are presented from an economic study. Results are reported on a successful 700-hour test of a 3-cell stack in the full-sized configuration (0.33m x 0.56m). Construction of a 5 kW equivalent methanol/steam reformer based on a commercial shell-and-tube heat exchanger was completed. Several test runs are summarized. Preliminary conclusions are presented on the technical and economic aspects of fuel cell/HVAC interaction. Physical data are presented on several dense graphite materials which are candidates for gas-distribution plates. Performance of a new cathode catalyst is reported.

Source record↗

Develop and test fuel cell powered on-site integrated total energy systems

On-going testing of an 11 cell, 10.7 in. x 14 in. stack (about 1 kW) reached 2600 hours on steady load. Nonmetallic cooling plates and an automated electrolyte replenishment system continued to perform well. A 10 cell, 10.7 in. x 14 in. stack was constructed with a modified electrolyte matrix configuration for the purpose of reducing cell IR loss. The desired effect was achieved, but the general cell performance level was irregular. Evaluation is continuing. Preparations for a long term 25 cell, 13 in. x 23 in. test stack (about 4 kW) approached completion. Start up in early May 1984 is expected.

Kaufman, A.↗

Develop and test fuel cell powered on-site integrated total energy systems. Phase 3: Full-scale power plant development

Two 25-cell, 13 inch x 23 inch (4kW) stacks were started up to evaluate the reliability of component and stack technology developed through the end of 1983. Both stacks started up well and are running satisfactorily on hydrogen-air after 1900 hours and 800 hours, respectively. A synthetic-reformat mixing station is nearing completion, and both stacks will be operated on reformate fuel. A stack-protection control system was placed in operation for Stack No. 2, and a similar set-up is in preparation for Stack No. 1. This system serves to change operating conditions or shut the stack down to avoid deleterious effects from nonstack-related upsets. The capability will greatly improve changes of obtaining meaningful long-term test data.

Kaufman, A.↗

Develop and test fuel cell powered on-site integrated total energy systems: Phase 3, full-scale power plant development

Two 25 cell stacks of the 13 inch x 23 inch cell size (about 4kW) remain on test after 4000 hours and 2900 hours, respectively, using simulated reformate fuel. These tests are focusing on the durability of fuel cell stack components developed through the end of 1983. Also, these stacks are serving as forerunners of a 25kW stack that will contain 175 cells of the same size and will employ the same technology base. The stack technology development program has focused on a new, low cost bipolar plate edge seal technique and evaluation of advanced cathode catalysts, an electrolyte replenishment system, and nonmetallic cooling plates in small stacks.

Kaufman, A.↗

Develop and test fuel cell powered on-site integrated total energy systems: Phase 3, full-scale power plant development

A 25 cell stack of the 13 inch x 23 inch cell size (about 4kW) remains on test after 6000 hours, using simulated reformate fuel. A similar stack was previously shut down after 7000 hours on load. These tests were carried out for the purpose of assessing the durability of fuel cell stack components developed through the end of 1983. In light of the favorable results obtained, a 25kW stack that will contain 175 cells of the same size is being constructed using the same technology base. The components for the 25kW stack have been completed. A methanol steam reformer with a design output equivalent to 50kW has been constructed to serve as a hydrogen generator for the 25kW stack. This reformer and the balance of the fuel processing sub system are currently being tested and debugged. The stack technology development program focused on cost reduction in bipolar plates, nonmetallic cooling plates, and current collecting plates; more stable cathode catalyst support materials; more corrosion resistant metal hardware; and shutdown/start up tolerance.

Kaufman, A.↗

Develop and test fuel cell powered on site integrated total energy systems. Phase 3: Full-scale power plant development

The third in a series of 4kW stacks, consisting of 24 cells of the 13 inch x 23 inch cell size, has been on test for about 1600 hours. This stack is similar to the first two stacks, which ran 7000 and 8400 hours, respectively. The present stack incorporates technology improvements relating to the electrolyte-matrix, the current-collector assembly, and a reduction in the number of cooling plates. Performance is currently averaging about 0.64 per cell at 161 mA sq cm.

Kaufman, A.↗

Develop and test fuel cell powered on-site integrated total energy systems. Phase 3: Full-scale power plant development

The testing of two 25-cell stacks of the 13 inch x 23 inch cell size (about 4kW) was carried out for 7000 and 8400 hours, respectively. A 25kW stack containing 175 cells of the same size and based on the same technology was constructed and is on test. A third 4kW stack, which will contain 24 cells, will comprise several new technology features; these will be assesed for performance and durability in long-term testing.

Kaufman, A.↗

Mathematical Models for Optimization of Grid-Integrated Energy Storage Systems

Energy storage has been proven to yield positive effects on planning, operation and control of electric grids. It has become a crucial task to properly model the energy storage systems (ESS) under the framework of grid optimization on transmission and distribution networks including microgrids. This paper presents a review on mathematical models and test cases of ESSs used for grid optimization studies, where the network constraints of power systems are included. The existing ESS models are mainly classified into two categories – linear and nonlinear models. The two main categories are further divided into several subcategories respectively; such as mixed-integer linear and convex nonlinear sub-categories. Based on the review and discussions, this paper aims at providing suggestions for choosing proper ESS models for specific grid optimization studies considering the chosen power network model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Learning from learning machines: improving the predictive power of energy-water-land nexus models with insights from complex measured and simulated data

Focal Area(s): Insights gleaned from complex data (observed and simulated) using AI; Predictive modeling through the use of AI techniques and AI-derived model components, including physics- and knowledge-informed models; Energy-water-land nexus and integrated energy systems – models of MultiSector dynamics. Science Challenge: Scientific communities are in need of tools for the computational integration of physics-based models, experimental data, and empirical/observational studies across a broad range of temporal and spatial scales to explore and meet EESSD grand challenges. We require AI algorithms for the discovery of process-drivers in the Earth-energy-human system and to link them with complex measured and simulated data. We aim to understand the energy-water-land nexus, particularly under extreme forcing scenarios and rare events, leveraging scale-aware AI process models, including probabilistic uncertainties, and benefiting from the emerging 5G-enabled landscape-scale sensing and edge computing capabilities. These models are needed to identify instabilities and tipping points that manifest extreme system behaviors with consequences for integrated energy systems and the environment. This work requires fundamental advances in uncertainty quantification, in particular, to identify and model unlikely but catastrophic outliers. Specifically, we need models that are interpretable to domain scientists and, essentially, explainable to public and private stake holders.

54 ENVIRONMENTAL SCIENCES↗

Human Dimensions of Energy Systems Workshop - September 6-7, 2022: Findings and Next Steps

Advanced energy technologies and informed policies are necessary but not sufficient to accelerate the energy transition at the speed required to meet our shared climate and energy resilience goals. To fully understand and implement integrated energy systems, we need to be able to model and analyze the complete system-of-systems, including the behavior of people interacting with and being impacted by energy systems. The purpose of this workshop is: Understand how human behavior and decisions affect the performance of energy systems with a focus on resilience and human well-being; Identify opportunities to improve energy system design to explicitly consider human behavior and well-being; Enhance our capability to model and predict human actions. Develop the ability to stress test these integrated systems; Identify or develop requirements and tools for more robust system designs that can be used for human-in-the-loop exercises and training; Identify opportunities for joint research, joint appointments, and collaboration; and Guide internal investments and strategic hires.

analyze↗

ARIES and ADMS Test Bed Overview and Updates

This presentation provides an overview and updates on the National Renewable Energy Laboratory's Advanced Research on Integrated Energy Systems (ARIES) platform and Advanced Distribution Management System (ADMS Test Bed).

ADMS↗

Demonstrate FARM supervisory capabilities for a thermal energy storage problem for the DETAIL facility: IES Simulation Ecosystem Control System Development

The goal of the power dispatch problem for an Integrated Energy System (IES) is to adjust the power output and the heat flow of each component to maximize the profitability of the whole unit. Facilities that can integrate real-time digital signals, mock nuclear power, thermal energy storage and industrial heat use via high-temperature electrolysis were constructed at INL to support the research activities. The Dynamic Energy Technology and Integration Laboratory (DETAIL) houses the Microreactor Agile Non-nuclear Experimental Test Bed (MAGNET) and the Thermal Energy Distribution System (TEDS). In this report, the hierarchical control system architecture proposed in June 2023 milestone for the flexible operation of DETAIL facility is finalized and demonstrated. A brief description of the components and the corresponding Dymola models from the HYRBID repository is first provided. Then, the current control strategy is presented. In particular, the approach for generating the set-point trajectories to be fed to the PI controllers is analyzed, and its limits were identified. To preserve safe operation over both long-time and real-time horizons, the integration of a Supervisory Control layer embedding a modified version of FARM (Feasible Actuator Range Modifier) module is proposed. FARM is a component of the RAVEN-based FORCE framework designed to support HERON module at optimizing the operation of IES units. The proposed control system for DETAIL foresees FARM to be applied twice, i.e., the original version (“FARM-Validator”) aiding the solution of the power dispatch problem, and a modified version (“FARM-Supervisory”) coordinating the PID controllers. Despite the kernel of the two modules is the same, their tasks are quite different. The former intervenes at the beginning of each hour to prevent constraint violations over long time periods, the latter addresses real-time control tasks and monitors the response of constrained variables at a much finer time resolution. A tentative procedure for training the embedded Digital Twins with the experimental data is also proposed. Finally, the capabilities of the designed architecture and the impact of the added Supervisory Control layer are demonstrated by simulating a representative power dispatch scenario.

25 ENERGY STORAGE↗

Integration of Dynamical System Scaling to RAVEN and Facility Application

As part of the design optimization and model validation effort within the hybrid energy systems program, the research to implement dynamical system scaling (DSS) code to RAVEN is funded under the Integrated Energy System program in collaboration with the Digital Reactor Technology & Development department. The DSS data processing algorithm has been coded within the RAVEN framework along with other metrics and postprocessing models. The implemented code was tested using a gravity-driven draining tank draining case modeled in RELAP5-3D and generated data was successfully postprocessed based on the scaling analyses defined by DSS. Postprocessed data concluded less agreement for the tank exit velocity and indicated that the modeled input deck for RELAP5-3D requires modification to enforce minimal pressure differential effects to the draining process.

97 MATHEMATICS AND COMPUTING↗

Future integrated mobility-energy systems: A modeling perspective

After over a century of petroleum dominance, the transportation sector is on the verge of radical transformations driven by rapid technology advancement of alternative fuels, automation, information technologies that create new mobility options and business models, and policies at all levels of government. While the technologies and fuels that will move people and goods in the future remain uncertain, the future transportation system will be more integrated with smart buildings, the electric grid, renewables, and information ecosystems, allowing for great opportunities to exploit these interconnections. Modeling tools for analyzing integrated mobility-energy systems require a deep understanding of these interconnections, of the infrastructure required to support alternative fuel vehicles, and a more nuanced understanding of transportation energy needs across multiple segments and spatiotemporal scales. In this paper, we assess the landscape of existing tools used to represent and model future mobility systems and their interactions with other energy systems. Here, we conclude that (a) out-of-sample extrapolation of emerging trends and future anticipated developments is more important than ever due to the plethora of factors driving disruptive change in mobility systems; (b) understanding adoption opportunities for alternative fuel light-duty vehicles requires modeling intra-household decisions affecting travel demand and mode choice; (c) mobility and energy systems need to be modeled as an integrated continuum, breaking the traditional approach in which dynamic energy supply models use relatively simple transportation demand and vice-versa; and (d) increased spatiotemporal fidelity and scalability are required to dynamically couple transportation/mobility and energy supply models and capitalize on these unprecedented interconnection opportunities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗