Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image reconstruction techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Distributed Tomographic Reconstruction with Quantization

Conventional tomographic reconstruction typically depends on centralized servers for both data storage and computation, leading to concerns about memory limitations and data privacy. Distributed reconstruction algorithms mitigate these issues by partitioning data across multiple nodes, reducing server load and enhancing privacy. However, these algorithms often encounter challenges related to memory constraints and communication overhead between nodes. In this paper, we introduce a decentralized Alternating Directions Method of Multipliers (ADMM) with configurable quantization. By distributing local objectives across nodes, our approach is highly scalable and can efficiently reconstruct images while adapting to available resources. To overcome communication bottlenecks, we propose two quantization techniques based on K-means clustering and JPEG compression. Numerical experiments with benchmark images illustrate the tradeoffs between communication efficiency, memory use, and reconstruction accuracy.

Miao, Runxuan↗

Three-dimensional imaging of hidden objects using positron emission backscatter

Positron emission backscatter imaging is a technique for interrogation and three-dimensional (3-D) reconstruction of hidden objects when we only have access to the objects from one side. Using time-of-flight differences in detected direct and backscattered positron-emitted photons, we construct 3-D images of target objects. Recently at Los Alamos National Laboratory, a fully three-dimensional imaging system has been built and the experimental results are discussed in this paper. Quantitative analysis of images reconstructed in both two- and three-dimensions are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-FG-207B-03: Multi-Energy CT Reconstruction with Spatial Spectral Nonlocal Means Regularization

Purpose: Multi-energy computed tomography (MECT) is an emerging application in medical imaging due to its ability of material differentiation and potential for molecular imaging. In MECT, image correlations at different spatial and channels exist. It is desirable to incorporate these correlations in reconstruction to improve image quality. For this purpose, this study proposes a MECT reconstruction technique that employes spatial spectral non-local means (ssNLM) regularization. Methods: We consider a kVp-switching scanning method in which source energy is rapidly switched during data acquisition. For each energy channel, this yields projection data acquired at a number of angles, whereas projection angles among channels are different. We formulate the reconstruction task as an optimziation problem. A least square term enfores data fidelity. A ssNLM term is used as regularization to encourage similarities among image patches at different spatial locations and channels. When comparing image patches at different channels, intensity difference were corrected by a transformation estimated via histogram equalization during the reconstruction process. Results: We tested our method in a simulation study with a NCAT phantom and an experimental study with a Gammex phantom. For comparison purpose, we also performed reconstructions using conjugate-gradient least square (CGLS) method and conventional NLM method that only considers spatial correlation in an image. ssNLM is able to better suppress streak artifacts. The streaks are along different projection directions in images at different channels. ssNLM discourages this dissimilarity and hence removes them. True image structures are preserved in this process. Measurements in regions of interests yield 1.1 to 3.2 and 1.5 to 1.8 times higher contrast to noise ratio than the NLM approach. Improvements over CGLS is even more profound due to lack of regularization in the CGLS method and hence amplified noise. Conclusion: The proposed ssNLM method for kVp-switching MECT reconstruction can achieve high quality MECT images.

60 APPLIED LIFE SCIENCES↗

SU-D-17A-01: Geometric and Dosimetric Evaluation of a 4D-CBCT Reconstruction Technique Using Prior Knowledge

Purpose: To evaluate a 4D-CBCT reconstruction technique both geometrically and dosimetrically Methods: A prior-knowledge guided 4DC-BCT reconstruction method named the motion-modeling and free-form deformation (MM-FD) has been developed. MM-FD views each phase of the 4D-CBCT as a deformation of a prior CT volume. The deformation field is first solved by principal component analysis based motion modeling, followed by constrained free-form deformation.The 4D digital extended-cardiac- torso (XCAT) phantom was used for comprehensive evaluation. Based on a simulated 4D planning CT of a lung patient, 8 different scenarios were simulated to cover the typical on-board anatomical and respiratory variations: (1) synchronized and (2) unsynchronized motion amplitude change for body and tumor; tumor (3) shrinkage and (4) expansion; tumor average position shift in (5) superior-inferior (SI) direction, (6) anterior-posterior (AP) direction and (7) SI, AP and lateral directions altogether; and (8) tumor phase shift relative to the respiratory cycle of the body. Orthogonal-view 30° projections were simulated based on the eight patient scenarios to reconstruct on-board 4D-CBCTs. For geometric evaluation, the volume-percentage-difference (VPD) was calculated to assess the volumetric differences between the reconstructed and the ground-truth tumor.For dosimetric evaluation, a gated treatment plan was designed for the prior 4D-CT. The dose distributions were calculated on the reconstructed 4D-CBCTs and the ground-truth images for comparison. The MM-FD technique was compared with MM-only and FD-only techniques. Results: The average (±s.d.) VPD values of reconstructed tumors for MM-only, FDonly and MM-FD methods were 59.16%(± 26.66%), 75.98%(± 27.21%) and 5.22%(± 2.12%), respectively. The average min/max/mean dose (normalized to prescription) of the reconstructed tumors by MM-only, FD-only, MM-FD methods and ground-truth tumors were 78.0%/122.2%/108.2%, 13%/117.7%/86%, 58.1%/120.8%/103.6% and 57.6%/118.6%/101.8%,respectively. Conclusion: The MM-FD method provides superior reconstruction accuracy both geometrically and dosimetrically, which can potentially be used for 4D target localization, dose tracking and adaptive radiation therapy. This research is supported by grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Textureless Macula Swelling Detection with Multiple Retinal Fundus Images

Retinal fundus images acquired with non-mydriatic digital fundus cameras are a versatile tool for the diagnosis of various retinal diseases. Because of the ease of use of newer camera models and their relatively low cost, these cameras can be employed by operators with limited training for telemedicine or Point-of-Care applications. We propose a novel technique that uses uncalibrated multiple-view fundus images to analyse the swelling of the macula. This innovation enables the detection and quantitative measurement of swollen areas by remote ophthalmologists. This capability is not available with a single image and prone to error with stereo fundus cameras. We also present automatic algorithms to measure features from the reconstructed image which are useful in Point-of-Care automated diagnosis of early macular edema, e.g., before the appearance of exudation. The technique presented is divided into three parts: first, a preprocessing technique simultaneously enhances the dark microstructures of the macula and equalises the image; second, all available views are registered using non-morphological sparse features; finally, a dense pyramidal optical flow is calculated for all the images and statistically combined to build a naiveheight- map of the macula. Results are presented on three sets of synthetic images and two sets of real world images. These preliminary tests show the ability to infer a minimum swelling of 300 microns and to correlate the reconstruction with the swollen location.

60 APPLIED LIFE SCIENCES↗

WE-FG-207B-04: Noise Suppression for Energy-Resolved CT Via Variance Weighted Non-Local Filtration

Purpose: The photon starvation problem is exacerbated in energy-resolved CT, since the detected photons are shared by multiple energy channels. Using pixel similarity-based non-local filtration, we aim to produce accurate and high-resolution energy-resolved CT images with significantly reduced noise. Methods: Averaging CT images reconstructed from different energy channels reduces noise at the price of losing spectral information, while conventional denoising techniques inevitably degrade image resolution. Inspired by the fact that CT images of the same object at different energies share the same structures, we aim to reduce noise of energy-resolved CT by averaging only pixels of similar materials - a non-local filtration technique. For each CT image, an empirical exponential model is used to calculate the material similarity between two pixels based on their CT values and the similarity values are organized in a matrix form. A final similarity matrix is generated by averaging these similarity matrices, with weights inversely proportional to the estimated total noise variance in the sinogram of different energy channels. Noise suppression is achieved for each energy channel via multiplying the image vector by the similarity matrix. Results: Multiple scans on a tabletop CT system are used to simulate 6-channel energy-resolved CT, with energies ranging from 75 to 125 kVp. On a low-dose acquisition at 15 mA of the Catphan©600 phantom, our method achieves the same image spatial resolution as a high-dose scan at 80 mA with a noise standard deviation (STD) lower by a factor of >2. Compared with another non-local noise suppression algorithm (ndiNLM), the proposed algorithms obtains images with substantially improved resolution at the same level of noise reduction. Conclusion: We propose a noise-suppression method for energy-resolved CT. Our method takes full advantage of the additional structural information provided by energy-resolved CT and preserves image values at each energy level. Research reported in this publication was supported by the National Institute Of Biomedical Imaging And Bioengineering of the National Institutes of Health under Award Number R21EB019597. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.

60 APPLIED LIFE SCIENCES↗

First M87 Event Horizon Telescope Results. IV. Imaging the Central Supermassive Black Hole

We present the first Event Horizon Telescope (EHT) images of M87, using observations from April 2017 at 1.3 mm wavelength. These images show a prominent ring with a diameter of ~40 μas, consistent with the size and shape of the lensed photon orbit encircling the "shadow" of a supermassive black hole. The ring is persistent across four observing nights and shows enhanced brightness in the south. To assess the reliability of these results, we implemented a two-stage imaging procedure. In the first stage, four teams, each blind to the others' work, produced images of M87 using both an established method (CLEAN) and a newer technique (regularized maximum likelihood). This stage allowed us to avoid shared human bias and to assess common features among independent reconstructions. In the second stage, we reconstructed synthetic data from a large survey of imaging parameters and then compared the results with the corresponding ground truth images. This stage allowed us to select parameters objectively to use when reconstructing images of M87. Across all tests in both stages, the ring diameter and asymmetry remained stable, insensitive to the choice of imaging technique. We describe the EHT imaging procedures, the primary image features in M87, and the dependence of these features on imaging assumptions.

79 ASTRONOMY AND ASTROPHYSICS↗

Application of morphological synthesis for understanding electrode microstructure evolution as a function of applied charge/discharge cycles

Morphological analysis and synthesis operations were employed for analysis of electrode microstructure transformations and evolution accompanying the application of charge/discharge cycles to electrochemical storage systems (batteries). Using state-of-the-art morphological algorithms, it was possible to predict microstructure evolution in porous Si electrodes for Li-ion batteries with sufficient accuracy. Algorithms for image analyses (segmentation, feature extraction, and 3D-reconstructions using 2D-images) were also developed. Altogether, these techniques could be considered supplementary to phase-field mesoscopic approach to microstructure evolution that is based upon clear and definitive changes in the appearance of microstructure. However, unlike in phase-field, the governing equations for morphological approach are geometry-, not physics-based. Similar non-physics based approach to understanding different phenomena was attempted with the introduction of cellular automata. It is anticipated that morphological synthesis and analysis will represent a useful supplementary tool to phase-field and will render assistance to unraveling the underlying microstructure-property relationships. The paper contains data on electrochemical characterization of different electrode materials that was conducted in parallel to morphological study.

25 ENERGY STORAGE↗

Region-of-interest diffuse optical tomography system

Diffuse optical tomography (DOT) using near-infrared light is a promising tool for non-invasive imaging of deep tissue. This technique is capable of quantitative reconstruction of absorption (μ{sub a}) and scattering coefficient (μ{sub s}) inhomogeneities in the tissue. The rationale for reconstructing the optical property map is that the absorption coefficient variation provides diagnostic information about metabolic and disease states of the tissue. The aim of DOT is to reconstruct the internal tissue cross section with good spatial resolution and contrast from noisy measurements non-invasively. We develop a region-of-interest scanning system based on DOT principles. Modulated light is injected into the phantom/tissue through one of the four light emitting diode sources. The light traversing through the tissue gets partially absorbed and scattered multiple times. The intensity and phase of the exiting light are measured using a set of photodetectors. The light transport through a tissue is diffusive in nature and is modeled using radiative transfer equation. However, a simplified model based on diffusion equation (DE) can be used if the system satisfies following conditions: (a) the optical parameter of the inhomogeneity is close to the optical property of the background, and (b) μ{sub s} of the medium is much greater than μ{sub a} (μ{sub s} > > μ{sub a}). The light transport through a highly scattering tissue satisfies both of these conditions. A discrete version of DE based on finite element method is used for solving the inverse problem. The depth of probing light inside the tissue depends on the wavelength of light, absorption, and scattering coefficients of the medium and the separation between the source and detector locations. Extensive simulation studies have been carried out and the results are validated using two sets of experimental measurements. The utility of the system can be further improved by using multiple wavelength light sources. In such a scheme, the spectroscopic variation of absorption coefficient in the tissue can be used to arrive at the oxygenation changes in the tissue.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Designing Antifouling and Antimicrobial Interfaces: Structural Characterization using CryoEM, Automated Microscopy, and AI Image Segmentation

The design of functionalized surfaces for interactions with biological systems is critical across sectors such as healthcare, energy, and agriculture. Tailoring materials for specific applications, such as antifouling and antimicrobial surfaces, demands a comprehensive understanding of topology and chemistry across multiple length and time scales on both biological and materials systems. This work presents the development and characterization of nanostructured surfaces with controlled topographies and chemistries that enhance bacterial membrane disruption, reduce biofilm formation, and improve antimicrobial and antifouling capabilities. Two specific use cases will be presented - the use of cellulose nanocrystals (CNCs) for bacterial growth inhibition and the development of antifouling surfaces to prevent protein and bacterial adsorption [1-4]. By leveraging large language models (LLMs) for image segmentation and training [5], we enable automated analysis of terabyte-scale cryogenic electron microscopy (cryoEM) datasets. This analysis provides statistical insights into the biotic/abiotic interface and facilitates automated electron microscopy experiments to mitigate time and dose. The integration of cryogenic electron tomography (cryoET) and cryogenic focused ion beam (cryoFIB) milling enables high-resolution, near-native-state imaging and 3D reconstructions of bio/material interfaces [6]. Orthogonal characterization techniques and computational modeling further enhances our understanding, offering a robust platform for the design and optimization of next-generation functional surfaces [7].

Williams, Alexis [ORNL] (ORCID:0000000252835822)↗

Testing light-traces-mass in Hubble Frontier Fields Cluster MACS-J0416.1-2403

Here, we reconstruct the projected mass distribution of a massive merging Hubble Frontier Fields cluster MACSJ0416 using the genetic algorithm based free-form technique called Grale. The reconstructions are constrained by 149 lensed images identified by Jauzac et al. using HFF data. No information about cluster galaxies or light is used, which makes our reconstruction unique in this regard. Using visual inspection of the maps, as well as galaxy-mass correlation functions we conclude that overall light does follow mass. Furthermore, the fact that brighter galaxies are more strongly clustered with mass is an important confirmation of the standard biasing scenario in galaxy clusters. On the smallest scales, approximately less than a few arcseconds, the resolution afforded by 149 images is still not sufficient to confirm or rule out galaxy-mass offsets of the kind observed in ACO 3827. We also compare the mass maps of MACSJ0416 obtained by three different groups: Grale, and two parametric Lenstool reconstructions from the CATS and Sharon/Johnson teams. Overall, the three agree well; one interesting discrepancy between Grale and Lenstool galaxy-mass correlation functions occurs on scales of tens of kpc and may suggest that cluster galaxies are more biased tracers of mass than parametric methods generally assume.

79 ASTRONOMY AND ASTROPHYSICS↗

Four years experience in APMS star plate processing - Results and future plans

The present paper describes an automated system for measuring stellar proper motions on the basis of information contained in photographic plates. In this system, the images on a star plate are digitized by a scanning microdensitometer using light from a He-Ne gas laser, and a special-purpose computer arranges the measurements in computer-compatible form on magnetic tape. The scanning and image-reconstruction processes are briefly outlined, and the image-evaluation techniques are discussed. It is shown that the present system has been especially successful in measuring the proper motions of low-luminosity stars, including 119 stars with less than 1/10,000 of the solar bolometric luminosity. Plans for measurements of high-density Milky Way star plates are noted.

Newcomb, J. S.↗

Spectral analysis of linear, shift-invariant interpolants

The use of a spectral analysis technique to evaluate the reconstruction/interpolation performance of linear, shift-invariant interpolants is examined. The technique was utilized to measure the performance of cubic hermite, quintic hermite, exponential, cubic, spline, Nu, PCC, Keys cubic, and BAWA cubic interpolants. The performance criterion is based upon the mean square error of the difference between the sampled and reconstructed functions. The reconstruction properties, interpolation functions, and reconstruction filters for the interpolants are studied and compared. It is noted that the spectral analysis technique is applicable to reconstruction algorithms used in signal and image processes, and interpolants used in numerical analysis, computer-aided design, and computer graphics.

Lansing, Donald L.↗

Lamb Wave Tomography for Corrosion Mapping

As the world-wide civil aviation fleet continues to age, methods for accurately predicting the presence of structural flaws-such as hidden corrosion-that compromise airworthiness become increasingly necessary. Ultrasonic guided waves, Lamb waves, allow large sections of aircraft structures to be rapidly inspected. However, extracting quantitative information from Lamb wave data has always involved highly trained personnel with a detailed knowledge of mechanical-waveguide physics. Our work focuses on using a variety of different tomographic reconstruction techniques to graphically represent the Lamb wave data in images that can be easily interpreted by technicians. Because the velocity of Lamb waves depends on thickness, we can convert the travel times of the fundamental Lamb modes into a thickness map of the inspection region. In this paper we show results for the identification of single or multiple back-surface corrosion areas in typical aluminum aircraft skin structures.

Hinders, Mark K.↗

Dual-Energy CT Pulmonary Angiography: Quantification of Disease Burden and Impact on Management

Purpose of Review: Computed tomography pulmonary angiography (CTPA) has become the imaging modality of choice for patients with suspected pulmonary embolism (PE). Post-processing techniques currently available for dual-energy CT pulmonary angiography (DE-CTPA) enhance image quality and provide additional value in the diagnosis of PE. The objective of this article is to summarize these recent developments and discuss the appropriate use of DE-CTPA post-processing applications. Recent Findings: DE-CTPA post-processing applications enable reconstruction of virtual monoenergetic images (VMI) and color-coded iodine-perfusion maps to increase contrast conditions and visualize lung perfusion defects in case of embolic occlusion of pulmonary arteries. Both techniques revealed a superior diagnostic performance for the detection of pulmonary emboli and assessment of the pulmonary perfusion compared to the standard image reconstructions. Summary: DE-CTPA is a well-established method for excluding or diagnosing PE. Continued developments in DE-CTPA post-processing techniques improve patient management and allow for a quantification of disease burden.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exploring the Inner Acceleration Region of Solar Wind: A Study Based on Coronagraphic UV and Visible Light Data

This work combined coronagraphic visible light (VL) and UV data to provide with an unprecedented view of the inner corona where the nascent solar wind is accelerated. The UV (H i Lyα) and VL (polarized brightness) images (reconstructed with SOHO/UVCS, LASCO, and Mauna Loa data) have been analyzed with the Doppler dimming technique to provide for the first time daily 2D images of the radial wind speed between 1 and 6 R {sub ⊙} over 1 month of observations. Results show that both polar and equatorial regions are characterized at the base of the corona by plasma outflows at speeds >100 km s{sup −1}. The plasma is then decelerated within ∼1.5 R {sub ⊙} at the poles and ∼2.0 R {sub ⊙} at the equator, where local minima of the expansion speeds are reached, and gently reaccelerated higher up, reaching speeds typical of fast and slow wind components. The mass flux is highly variable with latitude and time at the equator and more uniform and stable over the poles. The polar flow is asymmetric, with speeds above the south pole lower than those above the north pole. A correlation (anticorrelation) between the wind speed and its density is found below (above) ∼1.8 R {sub ⊙}. The 2D distribution of forces responsible for deceleration and reacceleration of solar wind is provided and interpreted in terms of Alfvén waves. These results provide a possible connection between small-scale outflows reported with other instruments at the base of the corona and bulk wind flows measured higher up.

79 ASTRONOMY AND ASTROPHYSICS↗

Non-uniform Neutron Source Approximation for Iterative Reconstruction of Coded Source Images

X-ray and neutron optics both lack ray focusing capabilities. An x-ray source can be made small and powerful enough to facilitate high-resolution imaging while providing adequate flux. This is not yet possible for neutrons. One remedy is to employ a computational imaging technique such as magnified coded source imaging. The greatest challenge associated with successful reconstruction of high-resolution images from such radiographs is to precisely model the flux distribution for complex non-uniform neutron sources. We have developed a framework based on Monte Carlo simulation and iterative reconstruction that facilitates high- resolution coded source neutron imaging. In this paper, we define a methodology to empirically measure and approximate the flux profile of a non-uniform neutron source, and we show how to incorporate the result within the forward model of an iterative reconstruction algorithm. We assess improvement in image quality by comparing reconstructions based respectively on the new empirical forward model and our previous analytic models.

Gregor, Jens↗

A Hierarchical Gibbs Sampler for Spatially Varying Multi-Regularization Image Reconstructions

This is a presentation for SIAM's (Society for Industrial and Applied Mathematics) conference on computational science and engineering. This presentation describes research on novel techniques to deblur images under a Bayesian framework. The title of the conference is SIAM Conference on Computational Science and Engineering (CSE21). This is a VIRTUAL conference; it was originally scheduled in Fort Worth, TX. The conference dates are March 1-5, 2021. The link to the conference's website is https://www.siam.org/conferences/cm/conference/cse21

97 MATHEMATICS AND COMPUTING↗