Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Inference of three-dimensional hot-spot and shell morphology in inertial confinement fusion experiments using a convolutional neural network

The performance of inertial confinement fusion (ICF) implosions is sensitive to the three-dimensional (3D) morphology of the hot-spot and shell configurations. The ability to infer shell-mass uniformity and reconstruct 3D hot spots is crucial for quantifying the degradation of ignition criteria and improving symmetry in ICF implosion experiments. In this work, we present a deep-learning convolutional neural network (CNN) for reconstructing 3D hot-spot and shell structures for ICF capsules. The 3D geometry of the hot spot is reconstructed from x-ray images measured from multiple lines of sight on OMEGA. The shell configuration is inferred indirectly through machine learning using a convolutional neural network extensively trained on a dec3d simulation database. This simulation-dependent approach yields consistent agreement between reconstructed 3D shell densities and machine-learning optimized dec3d simulation results. This work demonstrates a CNN framework that successfully reconstructs 3D capsule structures from two-dimensional images in ICF implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gaussian process analysis of electron energy loss spectroscopy data: multivariate reconstruction and kernel control

Abstract Advances in hyperspectral imaging including electron energy loss spectroscopy bring forth the challenges of exploratory and physics-based analysis of multidimensional data sets. The multivariate linear unmixing methods generally explore similarities in the energy dimension, but ignore correlations in the spatial domain. At the same time, Gaussian process (GP) explicitly incorporate spatial correlations in the form of kernel functions but is computationally intensive. Here, we implement a GP method operating on the full spatial domain and reduced representations in the energy domain. In this multivariate GP, the information between the components is shared via a common spatial kernel structure, while allowing for variability in the relative noise magnitude or image morphology. We explore the role of kernel constraints on the quality of the reconstruction, and suggest an approach for estimating them from the experimental data. We further show that spatial information contained in higher-order components can be reconstructed and spatially localized.

36 MATERIALS SCIENCE↗

Revealing Three-Dimensional Morphology in Nanoporous Gold Using Three-Dimensional X-Ray Fresnel Coherent Diffractive Imaging Tomography

Nanoporous metals fabricated by dealloying have a unique bi-continuous, sponge-like porous structure with ultra-high surface area. The unique properties of these materials, especially nanoporous gold, have numerous potential applications in sensors and actuators and in energy-related applications such as catalytic materials, super-capacitors, and battery supports. The degree of porosity and size of the metal ligaments are critical parameters that determine many properties and thus govern the functionalities of nanoporous metals in many applications including energy storage and conversion. Additionally, we used Fresnel coherent diffractive imaging combined with tomographic reconstruction to quantify the nanoscale three-dimensional spatial distribution and homogeneity of the porosity and ligament size within a bulk sample of nanoporous gold. The average porosity and its standard deviation along the axial direction through the sample were determined, as well as the characteristic feature size and its standard deviation. The result shows that free corrosion is an effective way to create homogeneous nanoporous metals with sample sizes on the order of 1 µm.

36 MATERIALS SCIENCE↗

Combined speckle- and propagation-based single shot two-dimensional phase retrieval method

Single-shot two-dimensional (2D) phase retrieval (PR) can recover the phase shift distribution within an object from a single 2D x-ray phase contrast image (XPCI). Two competing XPCI imaging modalities often used for single-shot 2D PR to recover material properties critical for predictive performance capabilities are: speckle-based (SP-XPCI) and propagation-based (PB-XPCI) XPCI imaging. However, PR from SP-XPCI and PB-XPCI images are, respectively, limited to reconstructing accurately slowly and rapidly varying features due to noise and differences in their contrast mechanisms. Herein, we consider a combined speckle- and propagation-based XPCI (SPB-XPCI) image by introducing a mask to generate a reference pattern and imaging in the near-to-holographic regime to induce intensity modulations in the image. We develop a single-shot 2D PR method for SPB-XPCI images of pure phase objects without imposing restrictions such as object support constraints. It is compared against PR methods inspired by those developed for SP-XPCI and PB-XPCI on simulated and experimental images of a thin glass shell before and during shockwave compression. Reconstructed phase maps show improvements in quantitative scores of root-mean-square error and structural similarity index measure using our proposed method.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CodEx: A Modular Framework for Joint Temporal De-Blurring and Tomographic Reconstruction

In many computed tomography (CT) imaging applications, it is important to rapidly collect data from an object that is moving or changing with time. Tomographic acquisition is generally assumed to be step-and-shoot, where the object is rotated to each desired angle, and a view is taken. However, step-and-shoot acquisition is slow and can waste photons, so in practice fly-scanning is done where the object is continuously rotated while collecting data. However, this can result in motion-blurred views and consequently reconstructions with severe motion artifacts. In this paper, we introduce CodEx, a modular framework for joint de-blurring and tomographic reconstruction that can effectively invert the motion blur introduced in sparse view fly-scanning. The method is a synergistic combination of a novel acquisition method with a novel non-convex Bayesian reconstruction algorithm. CodEx works by encoding the acquisition with a known binary code that the reconstruction algorithm then inverts. Using a well chosen binary code to encode the measurements can improve the accuracy of the inversion process. The CodEx reconstruction method uses the alternating direction method of multipliers (ADMM) to split the inverse problem into iterative deblurring and reconstruction sub-problems, making reconstruction practical to implement. Here we present reconstruction results on both simulated and binned experimental data to demonstrate the effectiveness of our method.

42 ENGINEERING↗

Reconstructed lung doses for the million person study cohort of 26,650 Tennessee Eastman corporation workers employed between 1942 and 1947

Abstract Tennessee Eastman Corporation workers were exposed to uranium dust resulting in high-linear energy transfer (LET) irradiation to lung tissue. In this work, radiation lung doses were reconstructed for 26 650 men and women working at the plant between 1942 and 1947. Site air monitoring data of uranium concentrations and payroll records were used to determine the daily inhaled activities and annualized lung doses. Variations in the activity median aerodynamic diameter of the uranium dust, the solubility of particulate matter in the lungs and the sex-specific breathing rate were investigated as part of a sensitivity analysis. Male and female mean lung doses of 18.9 and 32.7 mGy, respectively, from high-LET alpha irradiation, and there was general agreement with evaluations from previously published epidemiological studies. Annual lung dose estimates and sensitivity analysis for the 26 650 workers in the TEC cohort have been archived on the United States Department of Energy Comprehensive Epidemiologic Data Resource.

61 RADIATION PROTECTION AND DOSIMETRY↗

Neutron source reconstruction using a generalized expectation–maximization algorithm on one-dimensional neutron images from the Z facility

Magnetized Liner Inertial Fusion experiments have been performed at the Z facility at Sandia National Laboratories. These experiments use deuterium fuel, which produces 2.45 MeV neutrons on reaching thermonuclear conditions. To study the spatial structure of neutron production, the one-dimensional imager of neutrons diagnostic was fielded to record axial resolved neutron images. In this diagnostic, neutrons passing through a rolled edge aperture form an image on a CR-39-based solid state nuclear track detector. In this report we present a modified generalized expectation–maximization algorithm to reconstruct an axial neutron emission profile of the stagnated fusion plasma. We validate the approach by comparing the reconstructed neutron emission profile to an x-ray emission profile provided by a time-integrated pinhole camera.

47 OTHER INSTRUMENTATION↗

In situ laser profilometry for material segmentation and digital reconstruction of a multicomponent additively manufactured part

In addition to its ability to produce geometrically complex parts, additive manufacturing offers a unique opportunity to collect data about a component while it is being fabricated. However, there has only been limited effort to characterize parts morphologically and compositionally in situ. In this article, we present a layer-by-layer, laser profilometry-based in situ characterization technique as a method to digitally reconstruct a multi-material part. Data collected by the laser profilometer yields height maps and grayscale images which are voxelized using purpose-built software to volumetrically reconstruct the part. Additionally, the same part was also analyzed using X-ray computed tomography (CT) which was not able to resolve the different compositional regions within the part, but captured the filament morphology. The part was then bisected to compare the digital reconstruction to the actual part morphology and composition. Overall, the digital reconstruction was in good agreement with both the CT and bisected images. Deviations between the digital reconstruction and the CT/bisected images are likely the result of image segmentation settings or material shifts after data was collected. The in situ characterization method demonstrated here sets the stage for real time process monitoring and paves the way for additively manufactured parts that are “born qualified.”

36 MATERIALS SCIENCE↗

Processing-dependent chemical ordering in Cu 3 Au characterized via non-destructive Bragg coherent diffraction imaging

Of current importance for alloy design is controlling chemical ordering through processing routes to optimize an alloy's mechanical properties for a desired application. However, characterization of chemical ordering remains an ongoing challenge, particularly when nondestructive characterization is needed. Here, in this study, Bragg coherent diffraction imaging is used to reconstruct morphology and lattice displacement in model Cu 3 Au nanocrystals that have undergone different heat treatments to produce variation in chemical ordering. The magnitudes and distributions of the scattering amplitudes (proportional to electron density) and lattice strains within these crystals are then analyzed to correlate them to the expected amount of chemical ordering present. Nanocrystals with increased amounts of ordering are found to generally have less extreme strains present and reduced strain distribution widths. In addition, statistical correlations are found between the spatial arrangement of scattering amplitude and lattice strains.

Warren, Nathaniel [Pennsylvania State Univ., Unive↗

Circular dichroism in hard X-ray photoelectron diffraction observed by time-of-flight momentum microscopy

X-ray photoelectron diffraction (XPD) is a powerful technique that yields detailed structural information of solids and thin films that complements electronic structure measurements. Among the strongholds of XPD we can identify dopant sites, track structural phase transitions, and perform holographic reconstruction. High-resolution imaging of k ll -distributions (momentum microscopy) presents a new approach to core-level photoemission. It yields full-field k x -k y XPD patterns with unprecedented acquisition speed and richness in details. Here, we show that beyond the pure diffraction information, XPD patterns exhibit pronounced circular dichroism in the angular distribution (CDAD) with asymmetries up to 80%, alongside with rapid variations on a small k ll -scale (0.1 Å -1 ). Measurements with circularly-polarized hard X-rays (hν = 6 keV) for a number of core levels, including Si, Ge, Mo and W, prove that core-level CDAD is a general phenomenon that is independent of atomic number. The fine structure in CDAD is more pronounced compared to the corresponding intensity patterns. Additionally, they obey the same symmetry rules as found for atomic and molecular species, and valence bands. Further, the CD is antisymmetric with respect to the mirror planes of the crystal, whose signatures are sharp zero lines. Calculations using both the Bloch-wave approach and one-step photoemission reveal the origin of the fine structure that represents the signature of Kikuchi diffraction. To disentangle the roles of photoexcitation and diffraction, XPD has been implemented into the Munich SPRKKR package to unify the one-step model of photoemission and multiple scattering theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advanced multi-modal mass spectrometry imaging reveals functional differences of placental villous compartments at microscale resolution

The placenta is a complex and heterogeneous organ that links the mother and fetus, playing a crucial role in nourishing and protecting the fetus throughout pregnancy. Integrative spatial multi-omics approaches can provide a systems-level understanding of molecular changes underlying the mechanisms leading to the histological variations of the placenta during healthy pregnancy and pregnancy complications. Herein, we advance our metabolome-informed proteome imaging (MIPI) workflow to include lipidomic imaging, while also expanding the molecular coverage of metabolomic imaging by incorporating on-tissue chemical derivatization (OTCD). The improved MIPI workflow advances biomedical investigations by leveraging state-of-the-art molecular imaging technologies. Lipidome imaging identifies molecular differences between two morphologically distinct compartments of a placental villous functional unit, syncytiotrophoblast (STB) and villous core. Next, our advanced metabolome imaging maps villous functional units with enriched metabolomic activities related to steroid and lipid metabolism, outlining distinct molecular distributions across morphologically different villous compartments. Complementary proteome imaging on these villous functional units reveals a plethora of fatty acid- and steroid-related enzymes uniquely distributed in STB and villous core compartments. Integration across our advanced MIPI imaging modalities enables the reconstruction of active biological pathways of molecular synthesis and maternal-fetal signaling across morphologically distinct placental villous compartments with micrometer-scale resolution.

60 APPLIED LIFE SCIENCES↗

Experimental distinction of the molecularly induced Balmer emission contribution and its application for inferring molecular divertor density with 2D filtered camera measurements during detachment in JET L-mode plasmas

A previously presented model for generating 2D estimates of the divertor plasma conditions at JET from deuterium Balmer line intensity ratios, obtained from tomographic reconstructions of divertor camera images, was amended to consider also the Balmer emission arising from molecular processes. Utilizing the AMJUEL and H2VIBR atomic and molecular databases of EIRENE enabled also inference of the molecular divertor density from the distinguished molecularly induced emission. Analysis of a JET L-mode density scan suggests the molecularly induced emission accounting for up to 60%–70% and 10%–20% of the Balmer Dα and Dγ intensities, respectively, at the onset of detachment, while electron-ion recombination becomes increasingly dominant with deepening detachment. Similar observations were made by post-processing EDGE2D-EIRENE simulations, which indicated significant roles of molecular D$^{+}_{2}$ ions and vibrational excitation of the D 2 molecules as precursors for the molecularly induced emission. The experimentally inferred molecular density at the outer strike point was found to increase monotonously with decreasing strike point temperature, reaching approximately 30%–50% of the local electron density at n mol, osp = 1–2 X 10 20 m -3 at T e,osp ≈ 0.7 eV. A further steep increase by a factor of 3–5 was observed with decrease of T e,osp to 0.5 eV. The observations are in qualitative and reasonable quantitative agreement with EDGE2D-EIRENE predictions of n mol, osp within the uncertainties of the experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental 3-dimensional tracking of the dynamics of a single electron in the Fermilab Integrable Optics Test Accelerator (IOTA)

We present the results of experimental studies on the transverse and longitudinal dynamics of a single electron in the IOTA storage ring. IOTA is a flexible machine dedicated to beam physics experiments with electrons and protons. A method was developed to reliably inject and circulate a controlled number of electrons in the ring. A key beam diagnostic system is the set of sensitive high-resolution digital cameras for the detection of synchrotron light emitted by the electrons. With 60–130 electrons in the machine, we measured beam lifetime and derived an absolute calibration of the optical system. At exposure times of 0.5 s, the cameras were sensitive to individual electrons. Camera images were used to reconstruct the time evolution of oscillation amplitudes of a single electron in all 3 degrees of freedom. The evolution of amplitudes directly showed the interplay between synchrotron-radiation damping, quantum excitations, and scattering with the residual gas. From the distribution of measured single-electron oscillation amplitudes, we deduced transverse emittances, momentum spread, damping times, and beam energy. Estimates of residual-gas density and composition were calculated from the measured distributions of vertical scattering angles. Combining scattering and lifetime data, we also provide an estimate of the aperture of the ring. To our knowledge, this is the first time that the dynamics of a single electron are tracked in all three dimensions with digital cameras in a storage ring.

43 PARTICLE ACCELERATORS↗

High-resolution cryo-EM reconstructions in the presence of substantial aberrations

Here, an analysis is performed of how uncorrected antisymmetric aberrations, such as coma and trefoil, affect cryo-EM single-particle reconstruction (SPR) results, and an analytical formula quantifying information loss owing to their presence is inferred that explains why Fourier-shell coefficient-based statistics may report significantly overestimated resolution if these aberrations are not fully corrected. The analysis is validated with reference-based aberration refinement for two cryo-EM SPR data sets acquired with a 200 kV microscope in the presence of coma exceeding 40 µm, and 2.3 and 2.7 Å reconstructions for 144 and 173 kDa particles, respectively, were obtained. The results provide a description of an efficient approach for assessing information loss in cryo-EM SPR data acquired in the presence of higher order aberrations, and address inconsistent guidelines regarding the level of aberrations that is acceptable in cryo-EM SPR experiments.

3D reconstruction and image processing↗

Mechanical forces orchestrate the metabolism of the developing oilseed rape embryo

The initial free expansion of the embryo within a seed is at some point inhibited by its contact with the testa, resulting in its formation of folds and borders. Although less obvious, mechanical forces appear to trigger and accelerate seed maturation. However, the mechanistic basis for this effect remains unclear. Manipulation of the mechanical constraints affecting either the in vivo or in vitro growth of oilseed rape embryos was combined with analytical approaches, including magnetic resonance imaging and computer graphic reconstruction, immunolabelling, flow cytometry, transcriptomic, proteomic, lipidomic and metabolomic profiling. Our data implied that, in vivo, the imposition of mechanical restraints impeded the expansion of testa and endosperm, resulting in the embryo's deformation. An acceleration in embryonic development was implied by the cessation of cell proliferation and the stimulation of lipid and protein storage, characteristic of embryo maturation. The underlying molecular signature included elements of cell cycle control, reactive oxygen species metabolism and transcriptional reprogramming, along with allosteric control of glycolytic flux. Constricting the space allowed for the expansion of in vitro grown embryos induced a similar response. The conclusion is that the imposition of mechanical constraints over the growth of the developing oilseed rape embryo provides an important trigger for its maturation.

59 BASIC BIOLOGICAL SCIENCES↗

Deep Learning Super-Resolution X-Ray Computed Tomography Algorithms for Additive Manufacturing

Industrial X-ray computed tomography (XCT) is a nondestructive method for inspection and characterization of additively manufactured (AM) materials and parts. In practice, the resolution of XCT can be limited by factors such as detector binning, restricted field of view for large-scale objects, system blur, motion during scanning, and acquisition settings. These limitations can reduce the detectability of critical flaws such as pores, cracks, and lack of fusion. Super-resolution (SR) techniques offer a promising solution for improving the effective resolution and image quality of XCT reconstructions without the need for expensive hardware upgrades or laborious, time-consuming scans. In particular, deep learning-based SR methods have garnered attention in recent years as powerful tools for reconstructing high-resolution volumes from low-resolution inputs. In this work, a novel deep learning-based SR method is proposed for XCT scans of AM parts, and compared against several existing state-of-the-art (SOTA) methods. The proposed method, Simurgh-SR, is built on the pre-existing Simurgh framework and consists of a 2.5D U-Net trained to map low-quality inputs containing noise and artifacts to high-quality reconstructions characterized by higher flaw contrast, better noise texture, and reduced artifacts. The experimental results demonstrate superior performance of Simurgh-SR in performing 4× SR on real industrial XCT scans of thick 316L components, enhancing the structural similarity score and peak signal-to-noise ratio (>7dB) compared to the LR counterpart while improving the F1-score for flaw detection by more than 2.3× when compared to alternative SOTA SR methods. This improvement enables more accurate and significantly faster characterization of metal AM components. Additionally, Simurgh-SR was trained for both 2X and 4X SR and performs effectively at both levels, enabling the use of a single model for various SR factors.

Rahman, Obaid [ORNL] (ORCID:0000000277810840)↗

Toward inverse backscatter absorption gas imaging: imaging a dry gas plume with ambient H 2 O absorption

This paper introduces inverse backscatter absorption gas imaging (iBAGI), a transparent gas imaging technique based on absorption spectroscopy of gases naturally present in ambient air being displaced by transparent gases. We demonstrate reconstruction of a 2-D image of a dry gas plume by measuring light of a raster-scanned diode laser tuned to an absorption line of atmospheric H 2 O. We quantify the performance depending on the distance to the backdrop and show that the key transmission metric is independent of absorption path length. We conclude with an outlook toward calibration-free, single-ended iBAGI using scattering from low-reflectivity backdrops.

Klug, Joseph C.↗

3D Tracking of a Single Electron in IOTA

High-resolution observations of single-particle dynamics have potential as a powerful tool in the diagnostics, tuning and design of storage rings. We are presenting the results of experiments with single electrons that were conducted at Fermilab’s IOTA ring to explore the feasibility of this approach. A set of sensitive, high-resolution digital cameras was used to detect the synchrotron radiation emitted by an electron, and the resulting images were used to reconstruct the time evolution of oscillation amplitudes in all three degrees of freedom. From the evolution of the oscillation amplitudes, we deduce transverse emittances, momentum spread, damping times, beam energy and estimated residual-gas density and composition. To our knowledge, this is the first time that the dynamics of a single particle in a storage ring has been tracked in all three dimensions. We discuss farther development of a single particle diagnostics that may allow reconstruction of its turn-by-turn coordinates over macroscopic periods of time facilitating ultra-precise lattice diagnostics and direct benchmarking of tracking codes.

43 PARTICLE ACCELERATORS↗