Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IRS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Ferromagnetic cluster-glass phase in Ca(Co 1-x Ir x ) 2-y As 2 crystals

In this study, single crystals of Ca(Co 1-x Ir x ) 2-y As 2 with 0≤x≤0.35 and 0.10≤y≤0.14 have been grown using the self-flux technique and characterized by single-crystal x-ray diffraction (XRD), energy-dispersive x-ray spectroscopy, magnetization M, and magnetic susceptibility χ measurements versus temperature T, magnetic field H, and time t, and heat-capacity C p (H,T) measurements. The XRD refinements reveal that all the Ir-substituted crystals crystallize in a collapsed-tetragonal structure as does the parent CaCo 2-y As 2 compound. A small 3.3% Ir substitution for Co in CaCo 1.86 As 2 drastically lowers the A-type antiferromagnetic (AFM) transition temperature T N from 52 to 23 K with a significant enhancement of the Sommerfeld electronic heat-capacity coefficient. The A-type AFM structure consists of ab-plane layers of spins ferromagnetically aligned along the c axis with AFM alignment of the spins in adjacent layers along this axis. The positive Weiss temperatures obtained from Curie-Weiss fits to the χ(T>T N ) data indicate that the dominant magnetic interactions are ferromagnetic (FM) for all x. A magnetic phase boundary is inferred to be present between x=0.14 and x=0.17 from a discontinuity in the x dependencies of the effective moment and Weiss temperature in the Curie-Weiss fits. FM fluctuations that strongly increase with increasing x are also revealed from the χ(T) data. Furthermore, the magnetic ground state for x≥0.17 is a spin glass as indicated by hysteresis in χ(T) between field-cooled and zero-field-cooled measurements and from the relaxation of M in a small field that exhibits a stretched-exponential time dependence. The spin glass has a small FM component to the ordering and is hence inferred to be comprised of small FM clusters. The competing AFM and FM interactions along with crystallographic disorder associated with Ir substitution are inferred to be responsible for the development of a FM cluster-glass phase. A logarithmic T dependence of Cp at low T for x=0.14 is consistent with the presence of significant FM quantum fluctuations. This composition is near the T=0 boundary at x≈0.16 between the A-type AFM phase containing ferromagnetically-aligned layers of spins and the FM cluster-glass phase.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spin-orbit tuned metal-insulator transitions in single-crystal Sr₂Ir 1–x Rh x O₄ (0≤x≤1)

Sr₂IrO₄ is a magnetic insulator driven by spin-orbit interaction (SOI) whereas the isoelectronic and isostructural Sr₂RhO₄ is a paramagnetic metal. The contrasting ground states have been shown to result from the critical role of the strong SOI in the iridate. Our investigation of structural, transport, magnetic, and thermal properties reveals that substituting 4d Rh⁴⁺ (4d⁵) ions for 5d Ir⁴⁺ (5d⁵) ions in Sr₂IrO₄ directly reduces the SOI and rebalances the competing energies so profoundly that it generates a rich phase diagram for Sr₂Ir 1–x Rh x O₄ featuring two major effects: (1) Light Rh doping (0 ≤ x ≤ 0.16) prompts a simultaneous and precipitous drop in both the electrical resistivity and the magnetic ordering temperature TC, which is suppressed to zero at x = 0.16 from 240 K at x = 0. (2) However, with heavier Rh doping [0.24 < x < 0.85 (±0.05)] disorder scattering leads to localized states and a return to an insulating state with spin frustration and exotic magnetic behavior that only disappears near x = 1. The intricacy of Sr₂Ir 1–x Rh x O₄ is further highlighted by comparison with Sr₂Ir 1–x Ru x O₄ where Ru⁴⁺ (4d⁴) drives a direct crossover from the insulating to metallic states.

Qi, T. F.↗

Simultaneous metal-insulator and antiferromagnetic transitions in orthorhombic perovskite iridate Sr 0.94 Ir 0.78 O 2.68 single crystals

The orthorhombic perovskite SrIrO 3 is a semimetal, an intriguing exception in iridates where the strong spin-orbit interaction coupled with electron correlations tends to impose an insulating state. Here, we report results of our investigation of bulk single-crystal Sr 0.94 Ir 0.78 O 2.68 or Ir-deficient, orthorhombic perovskite SrIrO 3 . It retains the same crystal structure as stoichiometric SrIrO 3 but exhibits a sharp, simultaneous antiferromagnetic (AFM) and metal-insulator (MI) transition occurring in the basal-plane resistivity at 185 K. Above it, the basal-plane resistivity features an extended regime of almost linear temperature dependence up to 800 K but the strong electronic anisotropy renders an insulating behavior in the out-of-plane resistivity. The Hall resistivity undergoes an abrupt sign change and grows below 40 K, which along with the Sommerfeld constant of 20 mJ/mol K 2 suggests a multiband effect. All results including our first-principles calculations underscore a delicacy of the paramagnetic, metallic state in SrIrO 3 that is in close proximity to an AFM insulating state. The contrasting ground states in isostructural Sr 0.94 Ir 0.78 O 2.68 and SrIrO 3 illustrate a critical role of lattice distortions and Ir deficiency in rebalancing the ground state in the iridates. Finally, the concurrent AFM and MI transitions reveal a direct correlation between the magnetic transition and formation of an activation gap in the iridate, which is conspicuously absent in Sr 2 IrO 4 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Strong anisotropy within a Heisenberg model in the J eff = 1 2 insulating state of Sr 2 Ir 0.8 Ru 0.2 O 4

The dispersive magnetic excitations in Sr 2 IrO 4 have previously been well described within an isospin-1/2 Heisenberg model on a square lattice that revealed parallels with La 2 CuO 4 . In this paper, we investigate the inelastic spectra of Sr 2 Ir 0.8 Ru 0.2 O 4 with resonant inelastic x-ray scattering (RIXS) at the Ir L 3 edge. The results are well described using linear spin-wave theory within a similar Heisenberg model applicable to Sr 2 IrO 4 ; however, the disorder induced by the substitution of 20% Ir 4+ ions for Ru 4+ removes longer range exchange interactions. A large spin gap (40 meV) is measured indicating strong anisotropy from spin-orbit coupling that is manifest due to the altered magnetic structure in Sr 2 Ir 0.8 Ru 0.2 O 4 with c-axis aligned moments compared to the basal plane moments in the parent. Finally, collectively the results indicate the robustness of a Heisenberg model description even when the magnetic structure is altered and the J eff = 1/2 moments are diluted.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Feeding of the 11/2{sup -} isomers in stable Ir and Au isotopes

Excited states in {sup 191}Ir, {sup 193}Ir, and {sup 197}Au were studied and absolute partial {gamma}-ray cross sections were measured using the (n,n{sup '}{gamma}) reaction. A Compton-suppressed germanium-detector array (GEANIE) for {gamma}-ray spectroscopy was used for the measurement and the broad-spectrum pulsed neutron source of the Los Alamos Neutron Science Center's WNR facility provided energetic neutrons. The energy of the incident neutrons was determined using the time-of-flight technique. Absolute partial {gamma}-ray cross sections were measured up to incident neutron energy of 20 MeV for several transitions feeding directly the 11/2{sup -} isomers and ground states in {sup 191}Ir, {sup 193}Ir, and {sup 197}Au. The feeding of the 11/2{sup -} isomers, which originate from the odd proton occupying the h{sub 11/2} orbital, was found for the three targets to be very similar and increasing relative to the feeding of the corresponding ground state with increasing neutron energy up to E{sub n}{approx}10 MeV. Above this neutron energy the opening of the (n,2n) reaction channel strongly affects the population of the isomers and leads to a decrease of their relative population compared to the population of the ground states. The experimental results are compared with theoretical predictions from the GNASH reaction model calculation implementing a version of the spin distribution for the pre-equilibrium reaction piece with either a compound nucleus spin distribution (CN-GNASH) or a Feshbach-Kerman-Koonin (FKK-GNASH) quantum mechanical spin distribution. The effects of the spin cutoff parameter values on the population of states are examined. Evidence is presented that FKK-GNASH provides a description of the experimental data that mitigates the need for adjustment of the level density parameter to fit the data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Properties of the {pi}h{sub 11/2} band in the stable nucleus {sup 193}Ir

Excited states in the stable nucleus {sup 193}Ir have been investigated through an in-beam {gamma}-ray spectroscopic technique following the {sup 192}Os({sup 7}Li, {alpha}2n) reaction at a beam energy of 44 MeV. A level scheme built on the {pi}h{sub 11/2} isomer has been extended to high-spin states using eleven newly observed {gamma} transitions. The {pi}h{sub 11/2} band is proposed to be formed by coupling an h{sub 11/2} proton to a core with large triaxial deformation. Three-quasiparticle states are suggested in {sup 193}Ir on referring to the similar states in {sup 187}Ir. The features of signature splitting in the {pi}h{sub 11/2} bands of {sup 187-193}Ir are discussed with the help of total Routhian surface calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

UV massive resonance from IR double copy consistency

From the perspective of effective field theory (EFT), Wilson coefficients of the low energy theory are determined by integrating out modes of the full ultraviolet (UV) theory. The spectrum can be in principle resummed if one has access to all available infrared (IR) coefficients at low energies. In this work we show that there exists a general class of consistent massive resonance double-copy (CMRDC) models where UV massive residues are reconstructed through double-copy consistency conditions between the IR Wilson coefficients of the full EFT expansion. Through a color-dual bootstrap, we find surprisingly that double-copy consistency alone introduces the kinematic factors of CMRDC models that soften high energy behavior by exponentiating color-dual contacts. This bootstrap suggests that our massive resonance paradigm is an inevitable consequence of the duality between color and kinematics, thereby providing a path towards emergent UV structure directly from the IR. We then demonstrate how CMRDC models can capture a spectrum of massive modes compatible with general multiplicity, and use Padé extrapolation to solve the inverse problem of identifying massive UV resonance from a small number of IR Wilson coefficients. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Complex transport and magnetism in inhomogeneous mixed valence Ce 3 Ir 4 Ge 13

We report the discovery of Ce 3 Ir 4 Ge 13 , a Remeika phase with a complex array of structural, electronic, and magnetic properties. In this work, our single crystal x-ray diffraction measurements show that Ce 3 Ir 4 Ge 13 forms in the tetragonally distorted $I4_1/amd$ space group, which has three distinct rare earth sites. The electrical resistivity is almost temperature independent over three decades in temperature, from 0.4 K to 400 K, while the Hall coefficient measurements are consistent with a low-carrier semimetal. Magnetic susceptibility measurements reveal an effective moment, $μ^\text{exp}_\text{eff} = 1.87μ_B/$Ce, that falls significantly short of the expected value for Ce 3+ , suggesting that two of the rare earth sites are occupied by magnetic Ce 3+ while the third is occupied by nonmagnetic Ce 4+ . Upon cooling, Ce 3 Ir 4 Ge 13 first enters a short range magnetically ordered state below $T_\text{SRO}$ = 10 K, marked by a deviation from Curie-Weiss behavior in susceptibility and a broad field-independent heat capacity anomaly. At lower temperatures, we observe a second, sharper peak in the heat capacity at $T^\ast$ = 1.7 K, concurrent with a splitting of the field-cooled and zero-field-cooled susceptibilities. A small resistivity drop at $T^\ast$ suggests a loss of spin disorder scattering consistent with a magnetic ordering or spin freezing transition. Ce 3 Ir 4 Ge 13 is therefore a rare example of an inhomogeneous mixed valence compound with a complex array of thermodynamic and transport properties.

36 MATERIALS SCIENCE↗

IR laser-induced protein crystal transformation

A novel method and the associated instrumentation for improving crystalline order (higher resolution of X-ray diffraction and reduced mosaicity) of protein crystals by precisely controlled heating is demonstrated. Crystal transformation is optically controlled by a video system. A method and the design of instrumentation, and its preliminary practical realisation, including test experiments, with the object of inducing phase changes of biomolecular crystals by controlled dehydration through heating with infrared (IR) light are described. The aim is to generate and select crystalline phases through transformation in the solid state which have improved order (higher resolution in X-ray diffraction experiments) and reduced mosaic spread (more uniformly aligned mosaic blocks) for diffraction data collection and analysis. The crystal is heated by pulsed and/or constant IR laser irradiation. Loss of crystal water following heating and its reabsorption through equilibration with the environment is measured optically by a video system. Heating proved superior to traditional controlled dehydration by humidity change for the test cases CODH (carbon monoxide dehydrogenase) and CLK2 (a protein kinase). Heating with IR light is experimentally simple and offers an exploration of a much broader parameter space than the traditional method, as it allows the option of varying the rate of phase changes through modification of the IR pulse strength, width and repeat frequency. It impacts the crystal instantaneously, isotropically and homogeneously, and is therefore expected to cause less mechanical stress.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determination of absorbed dose in water at the reference point D(r{sub 0},{theta}{sub 0}) for an {sup 192}Ir HDR brachytherapy source using a Fricke system

A ring-shaped Fricke device was developed to measure the absolute dose on the transverse bisector of a {sup 192}Ir high dose rate (HDR) source at 1 cm from its center in water, D(r{sub 0},{theta}{sub 0}). It consists of a polymethylmethacrylate (PMMA) rod (axial axis) with a cylindrical cavity at its center to insert the {sup 192}Ir radioactive source. A ring cavity around the source with 1.5 mm thickness and 5 mm height is centered at 1 cm from the central axis of the source. This ring cavity is etched in a disk shaped base with 2.65 cm diameter and 0.90 cm thickness. The cavity has a wall around it 0.25 cm thick. This ring is filled with Fricke solution, sealed, and the whole assembly is immersed in water during irradiations. The device takes advantage of the cylindrical geometry to measure D(r{sub 0},{theta}{sub 0}). Irradiations were performed with a Nucletron microselectron HDR unit loaded with an {sup 192}Ir Alpha Omega radioactive source. A Spectronic 1001 spectrophotometer was used to measure the optical absorbance using a 1 mL quartz cuvette with 1.00 cm light pathlength. The PENELOPE Monte Carlo code (MC) was utilized to simulate the Fricke device and the {sup 192}Ir Alpha Omega source in detail to calculate the perturbation introduced by the PMMA material. A NIST traceable calibrated well type ionization chamber was used to determine the air-kerma strength, and a published dose-rate constant was used to determine the dose rate at the reference point. The time to deliver 30.00 Gy to the reference point was calculated. This absorbed dose was then compared to the absorbed dose measured by the Fricke solution. Based on MC simulation, the PMMA of the Fricke device increases the D(r{sub 0},{theta}{sub 0}) by 2.0%. Applying the corresponding correction factor, the D(r{sub 0},{theta}{sub 0}) value assessed with the Fricke device agrees within 2.0% with the expected value with a total combined uncertainty of 3.43%(k=1). The Fricke device provides a promising method towards calibration of brachytherapy radiation sources in terms of D(r{sub 0},{theta}{sub 0}) and audit HDR source calibrations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a water calorimetry-based standard for absorbed dose to water in HDR {sup 192}Ir brachytherapy

Purpose: The aim of this article is to develop and evaluate a primary standard for HDR {sup 192}Ir brachytherapy based on 4 deg. C stagnant water calorimetry. Methods: The absolute absorbed dose to water was directly measured for several different Nucletron microSelectron {sup 192}Ir sources of air kerma strength ranging between 21 000 and 38 000 U and for source-to-detector separations ranging between 25 and 70 mm. The COMSOL MULTIPHYSICS software was used to accurately calculate the heat transport in a detailed model geometry. Through a coupling of the ''conduction and convection'' module with the ''Navier-Stokes incompressible fluid'' module in the software, both the conductive and convective effects were modeled. Results: A detailed uncertainty analysis resulted in an overall uncertainty in the absorbed dose of 1.90%(1{sigma}). However, this includes a 1.5% uncertainty associated with a nonlinear predrift correction which can be substantially reduced if sufficient time is provided for the system to come to a new equilibrium in between successive calorimetric runs, an opportunity not available to the authors in their clinical setting due to time constraints on the machine. An average normalized dose rate of 361{+-}7 {mu}Gy/(h U) at a source-to-detector separation of 55 mm was measured for the microSelectron {sup 192}Ir source based on water calorimetry. The measured absorbed dose per air kerma strength agreed to better than 0.8%(1{sigma}) with independent ionization chamber and EBT-1 Gafchromic film reference dosimetry as well as with the currently accepted AAPM TG-43 protocol measurements. Conclusions: This work paves the way toward a primary absorbed dose to water standard in {sup 192}Ir brachytherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development and implementation of a remote audit tool for high dose rate (HDR) Ir-192 brachytherapy using optically stimulated luminescence dosimetry

Purpose: The aim of this work was to create a mailable phantom with measurement accuracy suitable for Radiological Physics Center (RPC) audits of high dose-rate (HDR) brachytherapy sources at institutions participating in National Cancer Institute-funded cooperative clinical trials. Optically stimulated luminescence dosimeters (OSLDs) were chosen as the dosimeter to be used with the phantom.Methods: The authors designed and built an 8 × 8 × 10 cm{sup 3} prototype phantom that had two slots capable of holding Al{sub 2}O{sub 3}:C OSLDs (nanoDots; Landauer, Glenwood, IL) and a single channel capable of accepting all {sup 192}Ir HDR brachytherapy sources in current clinical use in the United States. The authors irradiated the phantom with Nucletron and Varian {sup 192}Ir HDR sources in order to determine correction factors for linearity with dose and the combined effects of irradiation energy and phantom characteristics. The phantom was then sent to eight institutions which volunteered to perform trial remote audits.Results: The linearity correction factor was k{sub L}= (−9.43 × 10{sup −5}× dose) + 1.009, where dose is in cGy, which differed from that determined by the RPC for the same batch of dosimeters using {sup 60}Co irradiation. Separate block correction factors were determined for current versions of both Nucletron and Varian {sup 192}Ir HDR sources and these vendor-specific correction factors differed by almost 2.6%. For the Nucletron source, the correction factor was 1.026 [95% confidence interval (CI) = 1.023–1.028], and for the Varian source, it was 1.000 (95% CI = 0.995–1.005). Variations in lateral source positioning up to 0.8 mm and distal/proximal source positioning up to 10 mm had minimal effect on dose measurement accuracy. The overall dose measurement uncertainty of the system was estimated to be 2.4% and 2.5% for the Nucletron and Varian sources, respectively (95% CI). This uncertainty was sufficient to establish a ±5% acceptance criterion for source strength audits under a formal RPC audit program. Trial audits of four Nucletron sources and four Varian sources revealed an average RPC-to-institution dose ratio of 1.000 (standard deviation = 0.011).Conclusions: The authors have created an OSLD-based {sup 192}Ir HDR brachytherapy source remote audit tool which offers sufficient dose measurement accuracy to allow the RPC to establish a remote audit program with a ±5% acceptance criterion. The feasibility of the system has been demonstrated with eight trial audits to date.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-223: Investigation of the Accuracy of Two-Dimensional Dose Distributions Measurement From High-Dose-Rate Brachytherapy Ir-192 Source Using Multiple-Diode-Array Detector (MapCheck2)

Purpose: To investigate the dosimetric accuracy of multiple-diode-array detector (Mapcheck2) for high-dose-rate brachytherapy Ir-192 source. The two-dimensional (2D) dose distributions measured with MapCheck2 were validated with EBT2 Gafchromic film measurement and AAPM task-group- 43 (TG-43) modeling. Methods: 2D-dose distributions from Ir-192 source were measured with MapCheck2 and EBT2-films. MapCheck2 response was corrected for effects: directional dependence, diode and phantom heterogeneity. Optical density growth of the film was controlled by synchronized scanning of the film exposed to Ir-192 and calibration films exposed to 6 MV linac beams. Similarly, MapCheck2 response was calibrated to dose using 6 MV beams. An empirical model was developed for the dose distributions measured with Mapcheck2 that considered directional, diode and phantom heterogeneity corrections. The dose deposited in solid-state-detectors was modeled using a cavity theory model for the diode. This model was then validated with measurements using EBT2-films and calculations with TG-43. Results: The response of MapCheck2 has been corrected for different effects including: (a) directional dependence of 0–20% over angular range 0o–90o, (b) phantom heterogeneity (3%) and (c) diode heterogeneity (9%). The corrected dose distributions measured with MapCheck2 agreed well with the measured dose distributions from EBT2-film and with calculations using TG-43 within 5% over a wide range of dose levels and rates. The advantages of MapCheck2 include less noisy, linear and stable response compared with film. The response of MapCheck2 exposed to 192Ir-source showed no energy dependence similar to its response to MV energy beam. Detection spatial-resolution of individual diodes was 0.8×0.8 mm2, however, 2DMapCheck2 resolution is limited by distance between diodes (7.07 mm). Conclusion: The dose distribution measured with MapCheck2 agreed well within 5% with that measured using EBT2-films; and calculations with TG- 43. Considering correction of artifacts, MapCheck2 provides a compact, practical and accurate dosimetric tool for measurement of 2D-dose distributions for brachytherapy Ir-192.

60 APPLIED LIFE SCIENCES↗

SU-F-BRA-10: Fricke Dosimetry: Determination of the G-Value for Ir-192 Energy Based On the NRC Methodology

Purpose: Use the methodology developed by the National Research Council Canada (NRC), for Fricke Dosimetry, to determine the G-value used at Ir-192 energies. Methods: In this study the Radiology Science Laboratory of Rio de Janeiro State University (LCR),based the G-value determination on the NRC method, using polyethylene bags. Briefly, this method consists of interpolating the G-values calculated for Co-60 and 250 kV x-rays for the average energy of Ir-192 (380 keV). As the Co-60 G-value is well described at literature, and associated with low uncertainties, it wasn’t measured in this present study. The G-values for 150 kV (Effective energy of 68 keV), 250 kV (Effective energy of 132 keV)and 300 kV(Effective energy of 159 keV)were calculated using the air kerma given by a calibrated ion chamber, and making it equivalent to the absorbed to the Fricke solution, using a Monte Carlo calculated factor for this conversion. Instead of interpolations, as described by the NRC, we displayed the G-values points in a graph, and used the line equation to determine the G- value for Ir-192 (380 keV). Results: The measured G-values were 1.436 ± 0.002 µmol/J for 150 kV, 1.472 ± 0.002 µmol/J for 250 kV, 1.497 ± 0.003 µmol/J for 300 kV. The used G-value for Co-60 (1.25 MeV) was 1,613 µmol/J. The R-square of the fitted regression line among those G-value points was 0.991. Using the line equation, the calculate G-value for 380 KeV was 1.542 µmol/J. Conclusion: The Result found for Ir-192 G-value is 3,1% different (lower) from the NRC value. But it agrees with previous literature results, using different methodologies to calculate this parameter. We will continue this experiment measuring the G-value for Co-60 in order to compare with the NRC method and better understand the reasons for the found differences.

07 ISOTOPE AND RADIATION SOURCES↗

SU-G-201-17: Verification of Dose Distributions From High-Dose-Rate Brachytherapy Ir-192 Source Using a Multiple-Array-Diode-Detector (MapCheck2)

Purpose: To investigate quantitatively the accuracy of dose distributions for the Ir-192 high-dose-rate (HDR) brachytherapy source calculated by the Brachytherapy-Planning system (BPS) and measured using a multiple-array-diode-detector in a heterogeneous medium. Methods: A two-dimensional diode-array-detector system (MapCheck2) was scanned with a catheter and the CT-images were loaded into the Varian-Brachytherapy-Planning which uses TG-43-formalism for dose calculation. Treatment plans were calculated for different combinations of one dwell-position and varying irradiation times and different-dwell positions and fixed irradiation time with the source placed 12mm from the diode-array plane. The calculated dose distributions were compared to the measured doses with MapCheck2 delivered by an Ir-192-source from a Nucletron-Microselectron-V2-remote-after-loader. The linearity of MapCheck2 was tested for a range of dwell-times (2–600 seconds). The angular effect was tested with 30 seconds irradiation delivered to the central-diode and then moving the source away in increments of 10mm. Results: Large differences were found between calculated and measured dose distributions. These differences are mainly due to absence of heterogeneity in the dose calculation and diode-artifacts in the measurements. The dose differences between measured and calculated due to heterogeneity ranged from 5%–12% depending on the position of the source relative to the diodes in MapCheck2 and different heterogeneities in the beam path. The linearity test of the diode-detector showed 3.98%, 2.61%, and 2.27% over-response at short irradiation times of 2, 5, and 10 seconds, respectively, and within 2% for 20 to 600 seconds (p-value=0.05) which depends strongly on MapCheck2 noise. The angular dependency was more pronounced at acute angles ranging up to 34% at 5.7 degrees. Conclusion: Large deviations between measured and calculated dose distributions for HDR-brachytherapy with Ir-192 may be improved when considering medium heterogeneity and dose-artifact of the diodes. This study demonstrates that multiple-array-diode-detectors provide practical and accurate dosimeter to verify doses delivered from the brachytherapy Ir-192-source.

60 APPLIED LIFE SCIENCES↗

Multiphoton dissociation of CF{sub 3}I clusters by IR laser radiation

The results of investigation of dissociation of (CF{sub 3}I){sub n} clusters upon resonant excitation of vibrations of CF{sub 3}I molecules by pulsed CO{sub 2} laser radiation are reported. The kinetics of dissociation of such clusters is studied and the dissociation yield is measured. It is shown that its value is completely controlled by fluence {phi}{sub IR} of transmitted IR radiation energy and its time dependence is exponential. The results of measurements show that the dissociation lifetime of clusters is shorter than 10{sup -8} s. The velocity and translational temperature of free CF{sub 3}I molecules formed during dissociation of clusters are measured, as well as the dependence of these parameters on {phi}{sub IR}. It is concluded that, under these conditions of IR excitations, the dissociation of (CF{sub 3}I){sub n} clusters can be treated as consecutive evaporation of molecules.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-octave visible to long-wave IR femtosecond continuum generated in Cr:ZnS-GaSe tandem

We report a technique for generation of broad and coherent femtosecond (fs) continua that span several octaves from visible to long-wave IR parts of the spectrum (0.4–18 µm). The approach is based on simultaneous amplification of few-cycle pulses at 2.5 µm central wavelength at 80 MHz repetition rate, and augmentation of their spectrum via three-wave mixing in a tandem arrangement of polycrystalline Cr:ZnS and single crystal GaSe. The obtained average power levels include several mW in the 0.4–0.8 µm visible, 0.23 W in the 0.8–2 µm near-IR, up to 4 W in the 2–3 µm IR, and about 17 mW in the 3–18 µm long-wave IR bands, respectively. High brightness and mutual coherence of all parts of the continuum was confirmed by direct detections of the carrier envelope offset frequency of the master oscillator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

GROWTH on S190425z: Searching Thousands of Square Degrees to Identify an Optical or Infrared Counterpart to a Binary Neutron Star Merger with the Zwicky Transient Facility and Palomar Gattini-IR

The third observing run by LVC has brought the discovery of many compact binary coalescences. Following the detection of the first binary neutron star merger in this run (LIGO/Virgo S190425z), we performed a dedicated follow-up campaign with the Zwicky Transient Facility (ZTF) and Palomar Gattini-IR telescopes. The initial skymap of this single-detector gravitational wave (GW) trigger spanned most of the sky observable from Palomar Observatory. Covering 8000 deg2 of the initial skymap over the next two nights, corresponding to 46% integrated probability, ZTF system achieved a depth of ≈21 m AB in g- and r-bands. Palomar Gattini-IR covered 2200 square degrees in J-band to a depth of 15.5 mag, including 32% integrated probability based on the initial skymap. The revised skymap issued the following day reduced these numbers to 21% for the ZTF and 19% for Palomar Gattini-IR. We narrowed 338,646 ZTF transient "alerts" over the first two nights of observations to 15 candidate counterparts. Two candidates, ZTF19aarykkb and ZTF19aarzaod, were particularly compelling given that their location, distance, and age were consistent with the GW event, and their early optical light curves were photometrically consistent with that of kilonovae. These two candidates were spectroscopically classified as young core-collapse supernovae. The remaining candidates were ruled out as supernovae. Palomar Gattini-IR did not identify any viable candidates with multiple detections only after merger time. We demonstrate that even with single-detector GW events localized to thousands of square degrees, systematic kilonova discovery is feasible.

79 ASTRONOMY AND ASTROPHYSICS↗