Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION EXCHANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Computational modeling predicts the stability of both Pd + and Pd2 + ion-exchanged into H-CHA

Passive NO x adsorbers (PNA) using Pd/zeolites have emerged as a promising solution for the reduction of cold-start emissions from vehicle exhaust. However, the nature of the active sites and the mechanisms underlying NO x adsorption in Pd/zeolites remain a subject of ongoing investigation. In this study, we employ quantum chemical simulations to investigate the structure of Pd species in cation-exchange sites at isolated Al and Al pairs in the 6-ring and 8-ring of the CHA framework before the introduction of NO x . Our calculations show that the speciation of Pd in these exchange sites strongly depends on the precise Al arrangement within the framework, as well as the operating conditions. Ionically dispersed Pd is found to be the most favorable species over a wide range of oxidizing and reducing conditions. Small oligomers of PdO and metallic Pd do not appear to be competitive at either isolated Al or Al pairs. Notably, our calculations show that ion exchange sites other than next–next–nearest neighbor Al pairs in the 6-ring will be preferentially occupied by Pd + instead of Pd 2+ . The stability of Pd + in the zeolite environment is an interesting contrast with its rareness in molecular Pd compounds. Nonetheless, a detailed analysis of the electronic structure shows that predicted Pd oxidation states are consistent with chemical intuition for all complexes investigated in this study. We also discuss the potential ambiguity in Pd characterization provided by typical experimental techniques such as XANES, EXAFS and UV-Vis, and highlight the need for additional EPR spectroscopy studies to further elucidate the initial Pd speciation in zeolites for PNA applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adsorption Equilibrium, Kinetics, and Column Breakthrough Data for Aqueous Solutions of Binary-Acid and Ternary-Acid Mixtures of Acetic Acid, Butyric Acid, and Lactic Acid on IRN-78 Ion-Exchange Resin at Initial pH Levels of ∼3–7 and at 25–55 °C

This work is part of an effort to develop thermophysical property data and models supporting adsorptive process development for organic acid separation from a dilute aqueous solution of fermentation broth. It presents systematic experimental measurements for aqueous-phase adsorption equilibrium, kinetics, and column breakthrough for three binary-acid aqueous mixtures (acetic acid + lactic acid, butyric acid + lactic acid, and acetic acid + butyric acid) and one ternary-acid aqueous mixture (acetic acid + butyric acid + lactic acid) on Amberlite IRN-78 ion-exchange resin. The equilibrium measurements covered broad ranges of the initial acid concentration (100–400 mmol/L), initial pH (∼3–7), and temperature (25–55 °C). The equilibrium data for the binary-acid and ternary-acid aqueous mixtures indicate selective adsorption of lactic acid at initial pH levels of ∼3 and 4, while acetic acid and butyric acid are selectively adsorbed at initial pH levels of 5, 6, and 7. The subsequent kinetics and column breakthrough experiments were performed at 200 mmol/L with equimolar ratios, an initial pH of 6, and 25 °C. In conclusion, the measurements provide essential data sets for rigorous thermodynamic modeling and process simulation of adsorptive separation processes for organic acid separation from fermentation broth.

Adsorption↗

Removal of Technetium-99 on Ion Exchange Resin - A Case Study at 200 West Pump and Treat - 17303

The 200 West Pump and Treat (P and T), on the U.S. Department of Energy's Hanford Site and operated by CH2M HILL Plateau Remediation Company, has a 9,464 liters per minute capacity designed to capture and treat an 8 km{sup 2} contaminated groundwater plume and reduce the mass of contaminants of concern (COCs) by 95 percent in 25 years. The plume is a complex mix of contaminants including technetium-99 (Tc-99), uranium, carbon tetrachloride, chromium, hexavalent chromium, nitrate, and iodine-129 (I-129). Ion exchange (IX), a common treatment approach for Tc-99 used by many nuclear remediation sites, is used to remove uranium and Tc-99 at 200 West P and T. The IX vessels are arranged in a sequence of three to provide a lead, lag and polish vessel. Tc-99 concentrations are monitored monthly to assure good performance of the system. Performance tracking revealed surprising results. On October 14, 2015, the resin in the lead vessels released Tc-99 at concentrations greater than what was being fed. Although Tc-99 was captured by the downstream lag and polish vessels, the facility staff grabbled with the sudden release of Tc-99 entertaining a variety of scenarios that might result in sudden failure of the IX processes. Subsequent sampling indicated Tc-99 removal began a steady return to normal. The incident raised many questions, chief among them whether the same events could recur and undermine Tc-99 treatment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NaGaS 2 : An Elusive Layered Compound with Dynamic Water Absorption and Wide‐Ranging Ion‐Exchange Properties

Abstract Most ternary sulfides belonging to the MGaS 2 structure‐type have been known for many years and are well‐characterized. Surprisingly, there have been no reports of the NaGaS 2 composition, which contains Na, a monovalent cation slightly larger in size than Li, found in LiGaS 2 , a compound known for its non‐linear optical properties. Now it is demonstrated for the first time that the unique reversible water absorption in NaGaS 2 has resulted in its absence from previous reports owing to difficulties encountered when characterizing this compound by SC XRD. The layered structure of this compound coupled with uniquely easy migration of water molecules between the layers allows for ion exchange with 3d and 5f metal cations. Some cations, for example, Ni 2+ , facilitate exfoliation of the layers, providing a facile synthetic route to a new class of 2D chalcogenide materials and furthermore demonstrating that NaGaS 2 can readily uptake uranyl species from aqueous solutions.

Klepov, Vladislav V.↗

Ion-Exchange Membrane-Centric Durability Testing and Degradation Characterization for Industry-Relevant CO 2 Reduction

Electrochemical CO 2 reduction is a promising conversion process for producing value-added fuels and chemicals from electricity and CO 2 as a sustainable carbon feedstock to domestically produce fuels and chemicals from industrial waste. Having reached industrially viable performance metrics with small-scale CO 2 electrolysis cells, the field must now increasingly focus on extending the device durability of large stacks to achieve equivalent metrics for 35,000+ hours to decrease maintenance and capital costs. Reported device lifetimes have increased in recent years, with the longest stability studies for CO, ethylene, and formic acid production being published in 2024–2025 with operation times of 4500, 1000, and 5200 h, respectively. Unfortunately, significant extension of the device durability is still required. Here, we provide an overview of ion-exchange membranes (IEMs) and provide insight into the variety of degradation mechanisms that must be overcome to enable the community to meet durability targets. In an effort to accelerate the extension of device lifetimes, we propose a general approach for characterizing CO 2 electrolysis cell degradation before and after durability testing to better elucidate the mechanisms and failure modes of IEMs in zero-gap cells. Furthermore, we encourage the adoption of operando characterizations in tandem with accelerated stress and durability tests, postulating that their combined applications will be increasingly valuable. We hope that this perspective motivates future durability studies to evaluate degradation across the entire electrolysis cell.

09 BIOMASS FUELS↗

Ion Exchange Processing of AP-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The U.S. Department of Energy (DOE) is working to expedite processing of Hanford tank waste supernate at the Hanford Waste Treatment and Immobilization Plant (WTP). To support this goal, Washington River Protection Solutions, LLC (WRPS, Richland, WA) is designing a system for suspended solids and cesium (Cs/ 137 Cs) removal from Hanford tank waste supernate. The effluent will then be sent to the WTP Low-Activity Waste (LAW) Facility for vitrification. The Cs removal is critical for eliminating the high dose rate associated with 137 Cs and facilitating a contact maintenance philosophy for the LAW Facility. The maximum 137 Cs concentration in the LAW sent to the WTP is targeted to be below the 3.18E-5 Ci 137 Cs/mole of Na waste acceptance criteria (WAC) limit. The filtration and ion exchange systems will be placed near the Hanford tanks and are collectively termed the Tank Side Cesium Removal (TSCR) system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The mechanism and kinetics of methyl isobutyl ketone synthesis from acetone over ion-exchanged hydroxyapatite

The synthesis of methyl isobutyl ketone (MIBK) can be carried out by the condensation of acetone in the presence of hydrogen over a supported metal catalyst. Previous studies have shown that hydroxyapatite is an excellent catalyst for condensation reactions. The present investigation was undertaken in order to elucidate the reaction mechanism and site requirements for acetone coupling to MIBK over a physical mixture of hydroxyapatite and Pd/SiO 2 . The reaction is found to proceed by consecutive aldol addition to form diacetone alcohol (DAA), dehydration of DAA to mesityl oxide (MO), and hydrogenation of MO to MIBK. The products formed by feeding DAA and MO reveal that aldol addition of acetone is rapid and reversible, and that the subsequent dehydration of DAA is rate-limiting. Pyridine and CO 2 titration show that aldol dehydration occurs over basic sites via an E 1cB mechanism. A series of cation-substituted hydroxyapatite samples were prepared by ion-exchange to further investigate the role of acid-base strength on catalyst performance. Characterization of these samples by PXRD, BET, ICP-OES, XPS, CO 2 -TPD, and Raman spectroscopy demonstrated that the exchange procedure used does not affect the bulk properties of hydroxyapatite. Here, DFT calculations reveal that in addition to affecting the Lewis acidity/basicity of the support, the size of the cation plays a significant role in the chemistry: cations that are too large (Ba 2+ ) or too small (Mg 2+ ) adversely affect reaction rates due to excessive stabilization of intermediate species. Strontium-exchanged hydroxyapatite was found to be the most active catalyst because it promoted α-hydrogen abstraction and C–O bond cleavage of DAA efficiently.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Critical role of polymer-ceramic ion exchange for high conductivity composite electrolytes

Polymer-ceramic composites offer a path to enhance the transport and mechanical properties of solid electrolytes. However, an in-depth understanding of the extent and role of ion transport along and across polymer-ceramic interfaces in these systems is lacking. We have recently shown that Li-conducting Li 0.11 Na 0.24 K 0.02 La 0.43 TiO 2.82 (LMTO) nanorods can be prepared by a molten flux method, and the addition of 30–50 weight (wt.)% LMTO to a bis[(trifluoromethyl)sulfonyl]imide-vinyl ethylene carbonate-based single-ion conducting (SIC) polymer electrolyte leads to a two-fold enhancement in Li-ion conductivity, from 1.4 to 3.0 × 10 −5 S/cm at 30 °C. In the present study, we use NMR methods to identify the Li-ion transport pathways and determine the timescale of chemical exchange between the SIC polymer and LMTO ceramic components. Tracer exchange NMR indicates preferential transport through the polymer or polymer-interfacial regions, and exchange spectroscopy (EXSY) and a new isotope exchange method reveal negligible Li exchange between the SIC polymer and LMTO ceramic up to several days. Here, LMTO nanorods act as a passive filler. Our results further highlight that significant (e.g., 10- or 100-fold) conductivity enhancements in composite electrolytes can only be achieved 1) with ionically-conductive fillers, and 2) when both the ceramic and polymer components actively participate in long-range transport. For this, fast interfacial ion exchange is needed. In conclusion, this leads us to introduce a critical interfacial ion exchange time to evaluate whether a filler actively contributes to conduction in a composite electrolyte, and screen for promising polymer-ceramic pairings to accelerate the development of high conductivity solid electrolytes.

Battery, Solid electrolyte↗

PFAS Removal by Ion Exchange Resins: Background and Knowledge Gaps with Respect to the Hanford Site

Per- and polyfluoroalkyl substances (PFAS) have been a rising concern for the past two decades, with the United States Department of Defense and Environmental Protection Agency investing millions of dollars in research into remediation and clean-up technologies. Due to the environmental persistence, toxicity, biological uptake, and ongoing changes in both federal and state regulatory space, understanding the fate and transport of PFAS compounds has been of growing concern to the US Department of Energy (DOE). The DOE’s Hanford Site is investigating historical use of PFAS and will be doing site characterization for PFAS. Thus, PFAS have not yet been identified as a contaminant concern in regulatory documents. Based on historical records that mention the discharge of aqueous film-forming foam containing PFAS and having on-site fire stations (a risk factor for PFAS contamination), it seems likely that environmental releases of PFAS may have occurred. Pump and treat (P&T) remediation is the selected remedy for multiple groundwater contaminant plumes at Hanford. These P&T systems use ion exchange (IX) as a component of aboveground treatment, with the specific resins depending on the target contaminants. There is potential that these IX resins may be able to remove PFAS from groundwater, but investigation is needed to understand affinity/selectivity and removal capacity given the groundwater composition and the operating conditions. This report provides background on PFAS uses and chemistry, then provides a review of IX resin applications for PFAS, identifying knowledge gaps. Recommendations are provided regarding research needed to address knowledge gaps and acquire information needed to propose IX as a future PFAS remediation technology at the Hanford Site, as well as other U.S. Department of Energy sites. Generally, PFAS compounds are fluorinated substances that contain at least one fully fluorinated methyl or methylene carbon – with a few noted exceptions, any chemical with at least a perfluorinated methyl group (–CF3) or a perfluorinated methylene group (–CF2–) is a PFAS. These chemical compounds are characterized as non-biodegradable, non-reactive, non-photolytic, and hydrolysis resistant. This makes them highly recalcitrant within the environment, however polyfluoroalkyl materials are less recalcitrant as the carbon chains contain C–H bonds which are more easily broken than carbon – fluorine (C–F) bonds. The backbone carbon structures are commonly punctuated with a head group, the most well-known of them are perfluorooctanesulfonic acid and perfluorooctanoic acid, which possess a sulfonate and a carboxylate group, respectively. IX resins are marketed for the removal of PFAS from water systems and industrial water, however, the mechanism of removal is not as well understood as for anion or cation removal. A better understanding of the mechanism of removal would enable the development of IX resins that have improved specificity for PFAS removal. Four knowledge gaps were identified: 1) the effect of dissolved ions on the IX resin PFAS removal effectiveness, 2) the effect of additional primary contaminants of concern (PCOCs) or secondary contaminants of concern (SCOCs) on the effectiveness of PFAS via IX resin, 3) the mechanisms of PFAS removal from water, and 4) practical solutions to IX resin regeneration and waste disposal.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Small to Full Height Scale Comparisons of Cesium Ion Exchange Performance with Crystalline Silicotitanate

The U.S. Department of Energy’s (DOE) Hanford Site houses 56 million gallons of high-level radioactive waste generated from plutonium production from 1944 to 1988. The supernatant waste, currently stored in underground tanks, is intended to be vitrified following filtration and 137 Cs removal at the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Vitrification Facility. The WTP Pretreatment Facility will not be operational for several years. The Tank Side Cesium Removal (TSCR) system is a technology demonstration that will remove cesium from tank waste supernate to support directly feeding LAW to the vitrification facility. The 137 Cs removal is important to meet the WTP LAW contract specification and ultimately for creating a contact-handled waste form. The waste acceptance criteria (WAC) limit for the WTP LAW Facility is <3.18E-5 Ci 137 Cs per mole Na. The TSCR system is skid mounted and employs two key technologies: dead end filtration for solids removal and ion exchange (IX) for cesium removal. Filtration is necessary to protect the functionality of the IX columns. The IX process utilizes sodium form crystalline silicotitanate (CST) IX media produced by UOP Honeywell, LLC (Des Plaines, IL) under the product name IONSIV R9140-B, 18 x 50 mesh, in a lead-lag-polish column configuration. Each column contains a CST bed height of 92 inches and a volume of approximately 157 gallons of CST IX media. The full-scale TSCR operation will run at a residence time of 1.9 bed volumes (BV)/h, which results in a superficial velocity of 7.3 cm/min and a flowrate of ~5 gal/min. Column testing at small (2.5% of the full bed height), medium (12% of the full bed height), and full-height scales has been previously conducted to evaluate process variables and scale up performance of Cs exchange onto the CST. Cesium load performances from various sieve cuts at the small scale indicated that a 30-mesh sieve cut be tested to determine if it better reflects the 12% and full-height column performances at the small scale. Two process flowrates were tested in the small-column configuration with <30-mesh CST and simulant solutions. These tests were compared to full-height column tests at the same residence times to assess CST particle size effect on column scaling. Table S.1 summarizes the observed column performance determined for the two flowrates juxtaposed to the previous work with 5.6 M Na simulant at higher scales (used as benchmarks). The WAC breakthroughs between the small and full-height tests at 1.3 BV/h differed by ~59 BVs. The WAC breakthroughs for small, medium, and full-height tests at 1.8 BV/h were consistent at 240 BVs. The 50% Cs breakthroughs were nominally equivalent for all column tests. The common transition zones and onsets of Cs breakthrough at the 1.8 BV/h tests indicated that the Cs mass transfers were equivalent and thus the <30-mesh CST Cs load performance at the small scale successfully modeled that of the full-height system. It is recommended that the <30-mesh CST be used in subsequent 10-mL CST bed tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Efficiencies and Optimization of Weak Base Anion Ion-Exchange Resin for Groundwater Hexavalent Chromium Removal at Hanford

The U.S. Department of Energy’s (DOE’s) contractor, CH2M HILL Plateau Remediation Company, has successfully converted a series of groundwater treatment facilities to use a new treatment resin that is delivering more than $3 million in annual cost savings and efficiency in treating groundwater contamination at the DOE Hanford Site in southeastern Washington State. During the production era, the nuclear reactors at the Hanford Site required a continuous supply of high-quality cooling water during operations. Cooling water consumption ranged from about 151,417 to 378,541 L/min (40,000 to 100,000 gal/min) per reactor, depending on specific operating conditions. Water from the Columbia River was filtered and treated chemically prior to use as cooling water, including the addition of sodium dichromate as a corrosion inhibitor. Hexavalent chromium was the primary component of the sodium dichromate and was introduced into the groundwater at the Hanford Site as a result of planned and unplanned discharges from the reactors starting in 1944. Groundwater contamination by hexavalent chromium and other contaminants related to nuclear reactor operations resulted in the need for groundwater remedial actions within the Hanford Site reactor areas. Beginning in 1995, groundwater treatment methods were evaluated, leading to the use of pump-and-treat facilities with ion exchange using Dowex™ 21K, a regenerable, strong-base anion exchange resin. This required regeneration of the resin, which was performed offsite. In 2008, DOE recognized that regulatory agreements would require significant expansion for the groundwater chromium treatment capacity. As a result, CH2M HILL performed testing at the Hanford Site in 2009 and 2010 to demonstrate resin performance in the specific groundwater chemistry at different waste sites. The testing demonstrated that a weak-base anion, single-use resin, specifically ResinTech SIR-700 ®, was effective at removing chromium, had a significantly higher capacity, could be disposed of efficiently onsite, and would eliminate the complexities and programmatic risks from sampling, packaging, transportation, and return of resin for regeneration.

54 ENVIRONMENTAL SCIENCES↗

Polyamide-Based Ion Exchange Membranes: Cation-Selective Transport through Water Purification Membranes

Ion-selective membranes are necessary components of many electrochemical systems including fuel cells, electrolyzers, redox flow batteries, and electrodialyzers. Perfluorinated sulfonated membranes (PFSMs) dominate these applications due to their excellent combination of fast ion transport, stability, and processability. However, perfluorinated cation exchange membranes (CEMs) are expensive, and their production process involves chemistry that generates toxic perfluorinated chemicals. The development of affordable, nonfluorinated membranes with a competitive combination of high ion selectivity, transport, and stability could help enable the widespread use of the technologies listed above while hastening the development of emerging electrochemical systems, including aqueous alkaline CO 2 sorbent regeneration. To this end, we pursue the use of thin-film composite polyamide (PA-TFCs) membranes–those that typically find application in reverse osmosis and nanofiltration desalination–as cation-selective exchange membranes. Given their negative surface charge under neutral-to-alkaline conditions, PA-TFCs can serve as effective CEMs in these pH regimes. We prepared a series of PA-TFCs from traditional monomers (trimesoyl chloride and piperazine) and compared their thicknesses, charge densities, water transport properties, ion transport properties, and long-term stability in a high pH environment to traditional CEMs (Nafion and FKE) and commercial nanofiltration and reverse osmosis membranes. We find that some of the best-performing PA-TFC membranes have similar resistances and Na + transference numbers compared to Nafion 117 in Na 2 SO 4 and NaHCO 3 -containing solutions. This proof-of-principle study suggests that further optimization of PA-TFCs could enable cost-effective ion exchange membrane alternatives to PFSMs.

36 MATERIALS SCIENCE↗

Method for lithium extraction via ion exchange

Methods for extracting lithium from solutions containing lithium ions via reversible cation exchange with H+ are provided. The methods utilize metal oxide or metalloid oxide cation exchange materials having an active sublattice that preferentially bind Li+ cations, relative to both H+ and Na+, in a sample solution and preferentially bind H+, relative to Li+, in an acidic solution.

Snydacker, David H.↗

Development of separation technique of sodium nitrate from low-level radioactive liquid waste using electrodialysis with selective ion-exchange membranes

An advanced method, in which electrodialysis separation of sodium nitrate and decomposition of nitrate ion are combined, has been developed to remove nitrate ion from low-level radioactive liquid wastes including nitrate salts of high concentration. An engineering scale apparatus with two electro-dialytic devices, in which the sodium and nitrate ions were separately removed by each device, was produced on the basis of the results of fundamental investigation previously reported, and the performance of the apparatus was tested. Both the ions were successfully removed at the same time, though these ions were separately transferred using two electro-dialytic devices. And also effect of several experimental parameters such as current and temperature on current efficiency of both the ions of each device was investigated. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion exchange selectivity for cross-linked polyacrylic acid

The ion separation factors for 21 common metal ions with cross-linked polyacrylic acid were determined as a function of pH and the percent of the cross-linked polyacrylic acid neutralized. The calcium ion was used as a reference. At a pH of 5 the decreasing order of affinity of the ions for the cross-linked polyacrylic acid was found to be: Hg++, Fe+++, Pb++, Cr+++, Cu++, Cd++, Al+++, Ag+, Zn++, Ni++, Mn++, Co++, Ca++, Sr++, Ba++, Mg++, K+, Rb+, Cs+, Na+, and Li+. Members of a chemical family exhibited similar selectivities. The Hg++ ion appeared to be about a million times more strongly bound than the alkali metal ions. The relative binding of most of the metal ions varied with pH; the very tightly and very weakly bound ions showed the largest variations with pH. The calcium ion-hydrogen ion equilibrium was perturbed very little by the presence of the other ions. The separation factors and selectivity coefficients are discussed in terms of equilibrium and thermodynamic significance.

May, C. E.↗