Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IODINE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Norm - contaminated iodine production facilities decommissioning in Turkmenistan: experience and results

This report summarizes the data, including the cost parameters of the former iodine production facilities decommissioning project in Turkmenistan. Before the closure, these facilities were producing the iodine from the underground mineral water by the methods of charcoal adsorption. Balkanabat iodine and Khazar chemical plants' sites remediation, transportation and disposal campaigns main results could be seen. The rehabilitated area covers 47.5 thousand square meters. The remediation equipment main characteristics, technical solutions and rehabilitation operations performed are indicated also. The report shows the types of the waste shipping containers, the quantity and nature of the logistics operations. The project waste turnover is about 2 million ton-kilometers. The problems encountered during the remediation of the Khazar chemical plant site are discussed: undetected waste quantities that were discovered during the operational activities required the additional volume of the disposal facility. The additional repository wall superstructure was designed and erected to accommodate this additional waste. There are data on the volume and characteristics of the NORM waste disposed: 60.4 thousand cu.m. of NORM with total activity 1 439 x 10{sup 9} Bq (38.89 Ci) were disposed at all. This report summarizes the project implementation results, from 2009 to 15.02.2012 (the date of the repository closure and its placement under the controlled supervision), including monitoring results within a year after the repository closure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of x-ray energy dispersion in digital subtraction imaging at the iodine K-edge--A Monte Carlo study

The effect of the energy dispersion of a quasi-monochromatic x-ray beam on the performance of a dual-energy x-ray imaging system is studied by means of Monte Carlo simulations using MCNPX (Monte Carlo N-Particle eXtended) version 2.6.0. In particular, the case of subtraction imaging at the iodine K-edge, suitable for angiographic imaging application, is investigated. The average energies of the two beams bracketing the iodine K-edge are set to the values of 31.2 and 35.6 keV corresponding to the ones obtained with a compact source based on a conventional x-ray tube and a mosaic crystal monochromator. The energy dispersion of the two beams is varied between 0 and 10 keV of full width at half-maximum (FWHM). The signal and signal-to-noise ratio produced in the simulated images by iodine-filled cavities (simulating patient vessels) drilled in a PMMA phantom are studied as a function of the x-ray energy dispersion. The obtained results show that, for the considered energy separation of 4.4 keV, no dramatic deterioration of the image quality is observed with increasing x-ray energy dispersion up to a FWHM of about 2.35 keV. The case of different beam energies is also investigated by means of fast simulations of the phantom absorption.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-259: Particle Swarm Optimization in Radial Dose Function Fitting for a Novel Iodine-125 Seed

Purpose: To determine the coefficients of bi- and tri-exponential functions for the best fit of radial dose functions of the new iodine brachytherapy source: Iodine-125 Seed AgX-100. Methods: The particle swarm optimization (PSO) method was used to search for the coefficients of the biand tri-exponential functions that yield the best fit to data published for a few selected radial distances from the source. The coefficients were encoded into particles, and these particles move through the search space by following their local and global best-known positions. In each generation, particles were evaluated through their fitness function and their positions were changed through their velocities. This procedure was repeated until the convergence criterion was met or the maximum generation was reached. All best particles were found in less than 1,500 generations. Results: For the I-125 seed AgX-100 considered as a point source, the maximum deviation from the published data is less than 2.9% for bi-exponential fitting function and 0.2% for tri-exponential fitting function. For its line source, the maximum deviation is less than 1.1% for bi-exponential fitting function and 0.08% for tri-exponential fitting function. Conclusion: PSO is a powerful method in searching coefficients for bi-exponential and tri-exponential fitting functions. The bi- and tri-exponential models of Iodine-125 seed AgX-100 point and line sources obtained with PSO optimization provide accurate analytical forms of the radial dose function. The tri-exponential fitting function is more accurate than the bi-exponential function.

60 APPLIED LIFE SCIENCES↗

Model-based CT performance assessment and optimization for iodinated and noniodinated imaging tasks as a function of kVp and body size

Purpose: The goal of this study was to assess the comparative performance of iterative reconstruction in space (IRIS) and filtered back projection (FBP) reconstruction algorithms in terms of image quality and dose across kVps and phantom sizes. Methods: The ACR CT phantom (model 464) was supplemented with the addition of an iodinated spherical capsule (1.5 mm diameter, 3.4 mg iodine per ml) to simulate the contrast filled structures and with an additional circular attachment consisting of an array of 500 um brass beads for spatial resolution measurements. A larger sized phantom was also created by wrapping the original phantom with additional tissue equivalent material of 4 cm thickness. The phantoms were imaged on a 64 detector array multidetector computed tomography scanner (Somatom Definition, Siemens, Germany) using clinically applicable protocols (0.5 s rotation time; 80, 100, 120, and 140 kVp; 64 to 640 mA; 220 to 250 mm field of view). Images were reconstructed using the FBP and the IRIS algorithms. Combining measurements of image noise and spatial resolution with a task function, a figure of merit (FOM) for image quality was generated taking into account the type of visualization required from the image for the detection of either large or small image features with and without iodine content. The FOM was further reported in terms of area under the receiver operating characteristic (ROC) curve (A{sub Z}) to predict the comparative diagnostic performance of the two algorithms at different dose levels. Results: For a given dose level, the predicted A{sub Z} for IRIS consistently outperformed that of FBP. At comparative A{sub Z}, depending on protocol and task, the dose requirement for the optimal technique (optimized kVp with IRIS) was 2-3 times lower than that for standard technique (120 kVp with FBP). The potential for dose reduction was found to be higher when performing small feature detection tasks in comparison to larger feature detection tasks. The optimal kVp was from 80 to 100 kVp for the small phantom, 100 to 120 kVp for the larger phantom. Conclusions: Overall, greater dose reduction may be achieved with IRIS compared to FBP, with enhanced advantage at thinner slice reconstructions. The results highlight how IRIS may offer a superior balance between image quality and dose across a range of imaging tasks, thus enabling dose reduction at constant quality or image quality improvement at constant dose. The prediction of the investigation can be used toward effective design of subsequent clinical studies.

60 APPLIED LIFE SCIENCES↗

Kinetics of the processes, plasma parameters, and output characteristics of a UV emitter operating on XeI molecules and iodine molecules and atoms

A kinetic model of the processes occurring in the plasma of a high-power low-pressure gas-discharge lamp is presented, and the output characteristics of the lamp are described. The lamp is excited by a longitudinal glow discharge and emits the I{sub 2}(D Prime -A Prime ) 342-nm and XeI(B-X) 253-nm bands and the 206.2-nm spectral line of atomic iodine. When the emitter operates in a sealed-off mode on the p(He): p(Xe): p(I{sub 2}) = 400: 120: (100-200) Pa mixture, the fractions of the UV radiation power of iodine atoms, exciplex molecules of xenon iodide, and iodine molecules comprise 55, 10, and 35%, respectively. At the optimal partial pressure, the maximum total radiation power of the lamp reaches 37 W, the energy efficiency being about 15%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of iodine impurity on relaxation of photoexcited silver chloride

The time and temperature dependences of relaxation of excited AgCl and AgCl:I crystals is studied by the method of photostimulated flash of luminescence. The presence of iodine impurity in silver chloride gives rise to hole recombination (luminescence) centers and hole traps in the band gap. It is shown that the main contribution to the decrease in the concentration of electrons localized at deep traps is made by the recombination of electrons with holes released thermally from shallow localization levels (iodine-related centers). Estimation of activation energy for the relaxation process showed that these energies for the AgCl and AgCl:I samples under study are the same within the experimental error and are equal to E{sub rel1} = 0.01 {+-} 0.0005 eV for the initial stage of relaxation and E{sub rel2} = 0.09 {+-} 0.005 eV for the final state. This fact indicates that the majority of hole traps involved in the relaxation process in AgCl are related to iodine impurity. In the course of thermal relaxation in AgCl, relocalization of nonequilibrium charge carriers from shallow levels to deep levels is observed. The depth of the corresponding trap is E{sub arl} = 0.174 {+-} 0.03 eV.

36 MATERIALS SCIENCE↗

Process optimization of caustic scrubber and iodine-129 immobilization in sodalite-based waste forms

Caustic scrubbers are proposed to remove vaporized iodine from nuclear fuel reprocessing plants. Resulting caustic slurries of radioactive iodine ( 129 I) and other anions can be captured and immobilized into the cage structures of sodalite-type minerals. Here, mixed anion sodalites were hydrothermally synthesized from a simulated caustic scrubber solution containing hydroxide/water, carbonate, chlorine, bromine, iodine, nitrate, and nitrite ions with added kaolinite. Experiments were conducted with twenty-five different sets of process conditions. Resulting powders were characterized by quantitative X-ray diffraction (XRD) and multi-functional thermal analysis, including gravimetry, calorimetry, and mass spectrometry. Using statistical analysis, process variables were tailored to maximize conversion of kaolinite into cage silicates, immobilize caustic scrubber anions, and minimize amorphous content. Further, chemical analysis showed the incorporation of all the targeted ions into the solids. Detailed investigation of a batch characterized after washing (creating secondary waste) and one without washing but subsequent calcination is given. This work contributes to defining the constraints required for subsequent consolidation process steps of the waste form to avoid volatilization.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Initial Effects of NO x on Idodine and Methyl Iodine Loading of AgZ and Aerogels

This initial evaluation provides insight into the effect of NO on the adsorption of both I 2 and CH 3 I onto reduced silver-exchanged mordenite (Ag 0 Z). It was determined that adsorption of CH 3 I onto Ag 0 Z occurs at approximately 50% of the rate of I 2 adsorption onto Ag 0 Z, although total iodine capacities are comparable. Addition of 1% NO to the simulated off-gas stream results in very similar loading behaviors and iodine capacities for both iodine species. This is most likely an effect of CH 3 I oxidation to I 2 by NO prior to contact with the sorbent bed. Completion of tests including NO 2 in the simulated off-gas stream was delayed due to vendor NO 2 production schedules. A statistically designed test matrix is partially completed, and upon conclusion of the suggested experiments, the effects of temperature, NO, NO 2 , and water vapor on the sorption of CH 3 I and I 2 onto Ag 0 Z will be able to be statistically resolved. This work represents progress towards that aim.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Milestone Report - M4FT-17OR030107025 - Design of a tritium and iodine removal system for use with advanced TPOG

US regulations will require the removal of iodine and tritium, along with other volatile and semi-volatile radionuclides, from the off-gas streams of nuclear fuel reprocessing plants. Advanced tritium pretreatment (TPT) is an additional head-end operation that could be incorporated within nuclear fuel reprocessing plants. It utilizes nitrogen dioxide (NOR2R) as an oxidant to convert UOR2R to UR3ROR8R prior to traditional aqueous dissolution. Advanced TPT can result in the quantitative volatilization of both tritium and iodine. Up-front removal of iodine is of significant advantage because otherwise it distributes to several unit operations and the associated off-gas streams. The off-gas streams will then require treatment to comply with US regulations. Advanced TPT is currently under development at Oak Ridge National Laboratory, and a kilogram-scale hot cell demonstration with used nuclear fuel (UNF) is planned for fiscal year (FY) 2018.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact of Radiolysis on Iodine Speciation in a Variety of Matrices

This report details the work conducted in fiscal year 2023 with the aim of providing a better understanding of the speciation of iodine in support of domestic 99 Mo production Shine who uses a sulfate matrix in their process. Laboratory experiments to study the behavior of iodine speciation were conducted using spectroscopic methods including UV-vis and Raman as well as electrochemical studies. Radiolysis occurring in solution presents a unique challenge that is largely unaddressed with thermodynamic modeling, therefore a kinetic model was developed to address these issues. The focus of the studies conducted this year used surrogate radiolytic conditions induced by hydrogen peroxide for comparison to radiolytic conditions from direct gamma irradiation and neat acid solutions. For each case a model incorporating the kinetics was used to predict iodine speciation in the defined conditions where the output was directly compared to the experimental conditions. Further modeling was conducted incorporating the process conditions that are specific to Shine with incorporation of radiolysis and gas sparging.

07 ISOTOPE AND RADIATION SOURCES↗

LITERATURE SURVEY FOR GROUNDWATER TREATMENT OPTIONS FOR NITRATE IODINE-129 AND URANIUM 200-ZP-1 OPERABLE UNIT HANFORD SITE

This literature review presents treatment options for nitrate, iodine-129, and uranium, which are present in groundwater at the 200-ZP-I Groundwater Operable Unit (OU) within the 200 West Area of the Hanford Site. The objective of this review is to determine available methods to treat or sequester these contaminants in place (i.e., in situ) or to pump-and-treat the groundwater aboveground (i.e., ex situ). This review has been conducted with emphasis on commercially available or field-tested technologies, but theoretical studies have, in some cases, been considered when no published field data exist. The initial scope of this literature review included only nitrate and iodine-I 29, but it was later expanded to include uranium. The focus of the literature review was weighted toward researching methods for treatment of nitrate and iodine-129 over uranium because of the relatively greater impact of those compounds identified at the 200-ZP-I OU.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

Biocide↗

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

PWD↗

Development of iodine waste forms using low-temperature sintering glass.

This presentation will describe our recent work on the use of low temperature-sintering glass powders mixed with either AgI or AgI-zeolite to produce a stable waste form. Radioactive iodine ({sup 129}I, half-life of 1.6 x 10{sup 7} years) is generated in the nuclear fuel cycle and is of particular concern due to its extremely long half-life and its effects on human health. As part of the DOE/NE Advanced Fuel Cycle Initiative (AFCI), the separation of {sup 129}I from spent fuel during fuel reprocessing is being studied. In the spent fuel reprocessing scheme under consideration, the iodine is released in gaseous form and collected using Ag-loaded zeolites, to form AgI. Although AgI has extremely low solubility in water, it has a relatively high vapor pressure at moderate temperatures (>550 C), thus limiting the thermal processing. Because of this, immobilization using borosilicate glass is not feasible. Therefore, a bismuth oxide-based glasses are being studied due to the low solubility of bismuth oxide in aqueous solution at pH > 7. These waste forms were processed at 500 C, where AgI volatility is low but the glass powder is able to first densify by viscous sintering and then crystallize. Since the glass is not melted, a more chemically stable glass can be used. The AgI-glass mixture was found to have high iodine leach resistance in these initial studies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

IODINE ADSORPTION IN FIXED BED ADSORBER TESTS

I-129 emissions control is needed for used fuel aqueous reprocessing. I-129 capture has been studied for 40 years; Two sorbents tested in recent years – Silver Zeolite (AgZ) and silver-functionalized Aerogel (AGAero). Results show needed iodine adsorption efficiencies are possible, DFs up to10,000. Mass transfer zone (MTZ) depths ~2 in. for I2 and 8 in. for CH3I, but increase over time; deeper sorbent beds needed for efficient CH3I capture. Ag utilization between 10-70% for most test durations; lower for higher NOx. Iodine sorption capacities: ~10 g/100 AgZ and ~20 g/100 g AgAero; lower for high NOx. Nearly all adsorbed I was physisorbed iodine for I2 and CH3I.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Apatite Based Ceramic Waste Forms for Immobilization of Radioactive Iodine, An Overview - 16155

Apatite based ceramic waste forms are the most promising candidates for immobilization of radioactive iodine (I-129). While lead-vanadium based apatites have been studied for a long time, significant progress has been made in recent years in the domain of calcium-phosphate based apatites for iodine immobilization. This article is an attempt to present an overview of the progress that has been made in terms of developing novel synthesis and processing routes to contain iodine in apatite based ceramic waste forms. The challenges associated with current state-of-the art waste form synthesis techniques along with novel routes to synthesize these waste forms at low temperatures have also been discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigating the Durability of Iodine Waste Forms in Dilute Conditions

To prevent the release of radioiodine during the reprocessing of used nuclear fuel or in the management of other wastes, many technologies have been developed for iodine capture. The capture is only part of the challenge as a durable waste form is required to ensure safe disposal of the radioiodine. This work presents the first durability studies in dilute conditions of two AgI-containing waste forms: hot-isostatically pressed silver mordenite (AgZ) and spark plasma sintered silver-functionalized silica aerogel (SFA) iodine waste forms (IWF). Using the single-pass flow-through (SPFT) test method, the dissolution rates respective to Si, Al, Ag and I were measured for variants of the IWFs. By combining solution and solid analysis information on the corrosion mechanism neutral-to-alkaline conditions was elucidated. The AgZ samples were observed to have corrosion preferentially occur at secondary phases with higher Al and alkali content. These phases contained a lower proportion of I compared with the matrix. The SFA samples experienced a higher extent of corrosion at Si-rich particles, but an increased addition of Si to the waste led to an improvement in corrosion resistance. The dissolution rates for the IWF types are of similar magnitude to other Si-based waste form materials measured using SPFT.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Portal Vein Embolization Using a Nitinol Plug (Amplatzer Vascular Plug) in Combination with Histoacryl Glue and Iodinized Oil: Adequate Hypertrophy with a Reduced Risk of Nontarget Embolization

The purpose of this study was to assess whether portal vein embolization (PVE) using a nitinol vascular plug in combination with histoacryl glue and iodinized oil minimizes the risk of nontarget embolization while obtaining good levels of future liver remnant (FLR) hypertrophy. Between November 2005 and August 2008, 16 patients (8 females, 8 males; mean age, 63 {+-} 3.6 years), each with a small FLR, underwent right ipsilateral transhepatic PVE prior to major hepatectomy. Proximal PVE was initially performed by placement of a nitinol vascular plug, followed by distal embolization using a mixture of histoacryl glue and iodinized oil. Pre- and 6 weeks postprocedural FLR volumes were calculated using computed tomographic imaging. Selection for surgery required an FLR of 0.5% of the patient's body mass. Clinical course and outcome of surgical resection for all patients were recorded. At surgery, the ease of hepatectomy was subjectively assessed in comparison to previous experience following PVE with alternative embolic agents. PVE was successful in all patients. Mean procedure time was 30.4 {+-} 2.5 min. Mean absolute increase in FLR volume was 68.9% {+-} 12.0% (p = 0.00005). There was no evidence of nontarget embolization during the procedure or on subsequent imaging. Nine patients proceeded to extended hepatectomy. Six patients demonstrated disease progression. One patient did not achieve sufficient hypertrophy in relation to body mass to undergo hepatic resection. At surgery, the hepatobiliary surgeons observed less periportal inflammation compared to previous experience with alternative embolic agents, facilitating dissection at extended hepatectomy. In conclusion, ipsilateral transhepatic PVE using a single nitinol plug in combination with histoacryl glue and iodinized oil simplifies the procedure, offering short procedural times with minimal risk of nontarget embolization. Excellent levels of FLR hypertrophy are achieved enabling safe extended hepatectomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗