Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERFEROMETERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Three-colour digital holographic microscopy based on a Mach – Zender interferometer and a solid-state RGB laser

We have developed a facility for recording colour digital holograms involving a Mach – Zender interferometer and a pulsed solid-state RGB laser, which radiates simultaneously at three wavelengths: 451, 532, and 634 nm. These wavelengths are obtained in the conversion of the radiation of a pulsed Nd{sup 3+} : YAG laser (1064 nm), which operates in the regime of intracavity parametric oscillation at a wavelength of 1570 nm, with the subsequent conversion of its frequencies to the red, green, and blue spectral regions in nonlinear KTP-crystal elements. The combination of this three-wavelength pulsed light source with the Mach – Zender interferometer provides the simultaneous recording of three spectral digital holograms with one matrix RGB radiation detector. Pulsed three-colour digital holography shows promise for the analysis of fast processes and rapidly varying colour phase objects. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FUNDAMENTAL PERFORMANCE OF A DISPERSED FIXED DELAY INTERFEROMETER IN SEARCHING FOR PLANETS AROUND M DWARFS

We present a new method to calculate fundamental Doppler measurement limits with a dispersed fixed delay interferometer (DFDI) in the near-infrared (NIR) wavelength region for searching for exoplanets around M dwarfs in the coming decade. It is based on calculating the Q factor, a measure of flux-normalized Doppler sensitivity in the fringing spectra created with DFDI. We calculate the Q factor as a function of spectral resolution R, stellar-projected rotational velocity Vsin i, stellar effective temperature T{sub eff}, and optical path difference (OPD) of the interferometer. We also compare the DFDI Q factor to that for the popular cross-dispersed echelle spectrograph method (the direct echelle (DE) method). We find that (1) Q{sub DFDI} is a factor of 1.5-3 higher than Q{sub DE} at R ranging from 5000 to 20,000; (2) Q{sub DFDI} and Q{sub DE} converge at a very high R (R {>=} 100,000); (3) Q{sub DFDI} increases as R increases and Vsin i deceases; (4) for a given R, Q{sub DFDI} increases as T{sub eff} drops from 3100 K to 2400 K (M4V to M9V). We also investigate how Q{sub DFDI} is affected by OPD and find that a 5 mm deviation from the optimal OPD does not significantly affect Q{sub DFDI} (10% or less) for a wide range of R. Given that the NIR Doppler measurement is likely to be detector-limited for a while, we introduce new merit functions, which is directly related to photon-limited radial velocity (RV) uncertainty, to evaluate Doppler performance with the DFDI and DE methods. We find that DFDI has strength in wavelength coverage and multi-object capability over the DE for a limited detector resource. We simulate the performance of the InfraRed Exoplanet Tracker (IRET) based on the DFDI design, being considered for the next generation IR Doppler measurements. The predicted photon-limited RV uncertainty suggests that IRET is capable of detecting Earth-like exoplanets in habitable zone around nearby bright M dwarfs if they exist. A new method is developed to quantitatively estimate the influence of telluric lines on RV uncertainty. Our study shows that photon-limited RV uncertainty can be reached if 99% of the strength of telluric lines can be removed from the measured stellar spectra. At low to moderate levels of telluric line strength removal (50%-90%), the optimal RV uncertainty is typically a factor of two to three times larger than photon-limited RV uncertainty.

79 ASTRONOMY AND ASTROPHYSICS↗

LOCALIZING COMPACT BINARY INSPIRALS ON THE SKY USING GROUND-BASED GRAVITATIONAL WAVE INTERFEROMETERS

The inspirals and mergers of compact binaries are among the most promising events for ground-based gravitational-wave (GW) observatories. The detection of electromagnetic (EM) signals from these sources would provide complementary information to the GW signal. It is therefore important to determine the ability of GW detectors to localize compact binaries on the sky, so that they can be matched to their EM counterparts. We use Markov Chain Monte Carlo techniques to study sky localization using networks of ground-based interferometers. Using a coherent-network analysis, we find that the Laser Interferometer Gravitational Wave Observatory (LIGO)-Virgo network can localize 50% of their detected neutron star binaries to better than 50 deg{sup 2} with a 95% confidence interval. The addition of the Large Scale Cryogenic Gravitational Wave Telescope (LCGT) and LIGO-Australia improves this to 12 deg{sup 2}. Using a more conservative coincident detection threshold, we find that 50% of detected neutron star binaries are localized to 13 deg{sup 2} using the LIGO-Virgo network, and to 3 deg{sup 2} using the LIGO-Virgo-LCGT-LIGO-Australia network. Our findings suggest that the coordination of GW observatories and EM facilities offers great promise.

79 ASTRONOMY AND ASTROPHYSICS↗

THE KECK INTERFEROMETER NULLER

The Keck Interferometer Nuller (KIN), the first operational separated-aperture infrared nulling interferometer, was designed to null the mid-infrared emission from nearby stars so as to ease the measurement of faint circumstellar emission. This paper describes the basis of the KIN's four-beam, two-stage measurement approach and compares it to the simpler case of a two-beam nuller. In the four-beam KIN system, the starlight is first nulled in a pair of nullers operating on parallel 85 m Keck-Keck baselines, after which 'cross-combination' on 4 m baselines across the Keck apertures is used to modulate and detect residual coherent off-axis emission. Comparison to the constructive stellar fringe provides calibration. The response to an extended source is similar in the two cases, except that the four-beam response includes a term due to the visibility of the source on the cross-combiner baseline-a small effect for relatively compact sources. The characteristics of the dominant null depth errors are also compared for the two cases. In the two-beam nuller, instrumental imperfections and asymmetries lead to a series of quadratic, positive-definite null leakage terms. For the four-beam nuller, the leakage is instead a series of correlation cross-terms combining corresponding errors in each of the two nullers, which contribute offsets only to the extent that these errors are correlated on the timescale of the measurement. This four-beam architecture has allowed a significant ({approx}order of magnitude) improvement in mid-infrared long-baseline fringe-visibility accuracies.

79 ASTRONOMY AND ASTROPHYSICS↗

PLATFORM DEFORMATION PHASE CORRECTION FOR THE AMiBA-13 COPLANAR INTERFEROMETER

We present a new way to solve the platform deformation problem of coplanar interferometers. The platform of a coplanar interferometer can be deformed due to driving forces and gravity. A deformed platform will induce extra components into the geometric delay of each baseline and change the phases of observed visibilities. The reconstructed images will also be diluted due to the errors of the phases. The platform deformations of The Yuan-Tseh Lee Array for Microwave Background Anisotropy (AMiBA) were modeled based on photogrammetry data with about 20 mount pointing positions. We then used the differential optical pointing error between two optical telescopes to fit the model parameters in the entire horizontal coordinate space. With the platform deformation model, we can predict the errors of the geometric phase delays due to platform deformation with a given azimuth and elevation of the targets and calibrators. After correcting the phases of the radio point sources in the AMiBA interferometric data, we recover 50%-70% flux loss due to phase errors. This allows us to restore more than 90% of a source flux. The method outlined in this work is not only applicable to the correction of deformation for other coplanar telescopes but also to single-dish telescopes with deformation problems. This work also forms the basis of the upcoming science results of AMiBA-13.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring the cosmological 21 cm monopole with an interferometer

A measurement of the cosmological 21 cm signal remains a promising but as-of-yet unattained ambition of radio astronomy. A positive detection would provide direct observations of key unexplored epochs of our cosmic history, including the cosmic dark ages and reionization. In this paper, we concentrate on measurements of the spatial monopole of the 21 cm brightness temperature as a function of redshift (the “global signal”). Most global experiments to date have been single-element experiments. In this paper, we show how an interferometer can be designed to be sensitive to the monopole mode of the sky, thus providing an alternate approach to accessing the global signature. We provide simple rules of thumb for designing a global signal interferometer and use numerical simulations to show that a modest array of tightly packed antenna elements with moderately sized primary beams (FWHM of ∼40{sup ∘}) can compete with typical single-element experiments in their ability to constrain phenomenological parameters pertaining to reionization and the pre-reionization era. We also provide a general data analysis framework for extracting the global signal from interferometric measurements (with analysis of single-element experiments arising as a special case) and discuss trade-offs with various data analysis choices. Given that interferometric measurements are able to avoid a number of systematics inherent in single-element experiments, our results suggest that interferometry ought to be explored as a complementary way to probe the global signal.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of machine learning systems trained to detect Alfvén eigenmodes using the CO 2 interferometer on DIII-D

Abstract A Machine-Learning (ML) based detection scheme that automatically detects Alfvén Eigenmodes (AE) in a labelled DIII-D database is presented here. Controlling AEs is important for the success of planned burning plasma devices such as ITER, since resonant fast ions can drive AEs unstable and degrade the performance of the plasma or damage the first walls of the machine vessel. Artificial Intelligence could be useful for real-time detection and control of AEs in steady-state plasma scenarios by implementing ML-based models into control algorithms that drive actuators for mitigation of AE impacts. Thus, the objective is to compare differences in performance between using two different recurrent neural network systems (Reservoir Computing Network and Long Short Term Memory Network) and two different representations of the C O 2 phase data (simple and crosspower spectrograms). All C O 2 interferometer chords are used to train both models, but only one is processed during each training step. The results from the model and data comparison show higher performance for the RCN model (True Positive Rate = 90% and False Positive Rate = 14%), and that using simple magnitude spectrograms is sufficient to detect AEs. Also, the vertical C O 2 interferometer chord passing near the center is better for ML-based detection of AEs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stable generation of quadrature entanglement using a ring interferometer

We propose and demonstrate a scheme to stably generate quadrature-entangled optical pulses using a ring interferometer composed of an optical parametric amplifier and a dispersive media. The entangled light pulses at telecommunication wavelength are generated by combining two squeezed beams. In our scheme, the relative phase between the two beams is kept stable by the ring interferometer and is controllable using dispersive media. The amplitude and phase quadratures of the entangled beams are measured using two time-domain pulsed homodyne detectors. When the relative phase is fixed at {pi}/2, we verify the inseparability of the states by a sufficient criterion <{delta}{sup 2}[X{sub a}({phi}{sub 0})+X{sub b}({pi}-{phi}{sub 0})]>+<{delta}{sup 2}[X{sub a}({phi}{sub 0}{sup '})-X{sub b}(-{phi}{sub 0}{sup '})]>=0.64<1 where {phi}{sub 0}{sup '}-{phi}{sub 0}={pi}/2.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Resolution and sensitivity of a Fabry-Perot interferometer with a photon-number-resolving detector

With photon-number resolving detectors, we show compression of interference fringes with increasing photon numbers for a Fabry-Perot interferometer. This feature provides a higher precision in determining the position of the interference maxima compared to a classical detection strategy. We also theoretically show supersensitivity if N-photon states are sent into the interferometer and a photon-number resolving measurement is performed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct observation of geometric phases using a three-pinhole interferometer

We present a method to measure the geometric phase defined for three internal states of a photon (polarizations) using a three-pinhole interferometer. From the interferogram, we can extract the geometric phase related to the three-vertex Bargmann invariant as the area of a triangle formed by interference fringes. Unlike the conventional methods, our method does not involve the state evolution. Moreover, the phase calibration of the interferometer and the elimination of the dynamical phase are not required. The gauge invariance of the geometric phase corresponds to the fact that the area of the triangle is never changed by the local phase shift in each internal state.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comment on ''Rovibrational quantum interferometers and gravitational waves''

In a recent paper, Wicht, Laemmerzahl, Lorek, and Dittus [Phys. Rev. A 78, 013610 (2008)] come to the conclusion that a molecular rotational-vibrational quantum interferometer may possess the sensitivity necessary to detect gravitational waves. We do not agree with their results and demonstrate here that the true sensitivity of such an interferometer is many orders of magnitude worse than that claimed in the paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Continuous phase amplification with a Sagnac interferometer

We describe a phase-amplification technique using a Sagnac interferometer. We monitor the relative phase between two paths of a precisely misaligned interferometer by measuring the average position of a split-Gaussian mode in the dark port. Although we monitor only the dark port, we show that the signal varies linearly with phase and that we can obtain similar sensitivity to balanced homodyne detection. We derive the source of the amplification using classical wave optics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical simulation of a multilevel atom interferometer

We present a comprehensive numerical simulation of an echo-type atom interferometer. The simulation confirms an interesting theoretical description of this interferometer that includes effects due to spontaneous emission and magnetic sublevels. Both the simulation and the theoretical model agree with the results of experiments. These developments provide an improved understanding of several observable effects. The evolution of state populations due to stimulated emission and absorption during the standing-wave interaction imparts a time-dependent phase on each atomic momentum state. This manifests itself as an asymmetry in the signal shape that depends on the strength of the interaction as well as spontaneous emission due to a nonzero population in the excited states. The degree of asymmetry is a measure of a nonzero relative phase between interfering momentum states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal calcium atom interferometer with a phase resolution of a few milliradians based on a narrow-linewidth diode laser

A symmetrical atom interferometer with a thermal calcium atom beam has been developed using a narrow linewidth diode laser stabilized to the resonance of a high-finesse cavity. The linewidth of the diode laser was estimated to be less than 1 Hz relative to the cavity resonance in noise measurement over the range of 100 Hz to 1 MHz, and the phase instability of the interference fringes obtained from the Allan deviation was improved to 2 mrad at an integration time of 300 s. Using this atom interferometer, the ac Stark phase shift between the {sup 1}S{sub 0} and {sup 3}P{sub 1} states of a Ca atom was measured as a function of a laser power near the resonance of the {sup 1}S{sub 0}-{sup 1} P{sub 1} transition at a wavelength of 423 nm. The decay rate of the {sup 1}P{sub 1} state was determined to be {gamma}=1.91(33)x10{sup 8} s{sup -1}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of a free oscillation atom interferometer

We analyze a Bose-Einstein condensate (BEC)-based free oscillation atom Michelson interferometer in a weakly confining harmonic magnetic trap. A BEC at the center of the trap is split into two harmonics by a laser standing wave. The harmonics move in opposite directions with equal speeds and turn back under the influence of the trapping potential at their classical turning points. The harmonics are allowed to pass through each other and a recombination pulse is applied when they overlap at the end of a cycle after they return for the second time. We derive an expression for the contrast of the interferometric fringes and obtain the fundamental limit of performance of the interferometer in the parameter space.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Manipulation of the resonance interaction in Mach-Zehnder-Fano interferometers

We study tunable interaction of the resonances in the Mach-Zehnder-Fano interferometers (MZFIs). A discrete Mach-Zehnder interferometer (MZI) with balanced arms supports bound states in the continuum. We demonstrate that doping an impurity in conventional MZIs gives rise to robust high-Q Fano resonances with asymmetric line shapes. By means of the modified Fano-Anderson model and the scattering-matrix approach, we show that the transmission and the intensity spectra of the whole system are very sensitive to both the location and the strength of the impurity. The side-coupled Fano defects induce an interaction with different eigenmodes of the pure MZI loop. We explore this interaction by tuning the parameters of the Fano defects. The observed resonance interaction can be attributed to the Fano-Feshbach resonance. We further provide with a particular physical example of photonic crystal circuit the applicability of our concept.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prototyping method for Bragg-type atom interferometers

We present a method for rapid modeling of new Bragg ultracold atom-interferometer (AI) designs useful for assessing the performance of such interferometers. The method simulates the overall effect on the condensate wave function in a given AI design using two separate elements. These are (1) modeling the effect of a Bragg pulse on the wave function and (2) approximating the evolution of the wave function during the intervals between the pulses. The actual sequence of these pulses and intervals is then followed to determine the approximate final wave function from which the interference pattern can be calculated. The exact evolution between pulses is assumed to be governed by the Gross-Pitaevskii (GP) equation whose solution is approximated using a Lagrangian variational method to facilitate rapid estimation of performance. The method presented here is an extension of an earlier one that was used to analyze the results of an experiment [J. E. Simsarian et al., Phys. Rev. Lett. 85, 2040 (2000)], where the phase of a Bose-Einstein condensate was measured using a Mach-Zehnder-type Bragg AI. We have developed both 1D and 3D versions of this method and we have determined their validity by comparing their predicted interference patterns with those obtained by numerical integration of the 1D GP equation and with the results of the above experiment. We find excellent agreement between the 1D interference patterns predicted by this method and those found by the GP equation. We show that we can reproduce all of the results of that experiment without recourse to an ad hoc velocity-kick correction needed by the earlier method, including some experimental results that the earlier model did not predict. We also found that this method provides estimates of 1D interference patterns at least four orders-of-magnitude faster than direct numerical solution of the 1D GP equation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of asymptotic expansions for maximum likelihood estimators errors to gravitational waves from binary mergers: The single interferometer case

In this paper we apply to gravitational waves (GW) from the inspiral phase of binary systems a recently derived frequentist methodology to calculate analytically the error for a maximum likelihood estimate of physical parameters. We use expansions of the covariance and the bias of a maximum likelihood estimate in terms of inverse powers of the signal-to-noise ration (SNR)s where the square root of the first order in the covariance expansion is the Cramer Rao lower bound (CRLB). We evaluate the expansions, for the first time, for GW signals in noises of GW interferometers. The examples are limited to a single, optimally oriented, interferometer. We also compare the error estimates using the first two orders of the expansions with existing numerical Monte Carlo simulations. The first two orders of the covariance allow us to get error predictions closer to what is observed in numerical simulations than the CRLB. The methodology also predicts a necessary SNR to approximate the error with the CRLB and provides new insight on the relationship between waveform properties, SNR, dimension of the parameter space and estimation errors. For example the timing match filtering can achieve the CRLB only if the SNR is larger than the Kurtosis of the gravitational wave spectrum and the necessary SNR is much larger if other physical parameters are also unknown.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗