Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

AutoCCS: automated collision cross-section calculation software for ion mobility spectrometry–mass spectrometry

Abstract Motivation Ion mobility spectrometry (IMS) separations are increasingly used in conjunction with mass spectrometry (MS) for separation and characterization of ionized molecular species. Information obtained from IMS measurements includes the ion’s collision cross section (CCS), which reflects its size and structure and constitutes a descriptor for distinguishing similar species in mixtures that cannot be separated using conventional approaches. Incorporating CCS into MS-based workflows can improve the specificity and confidence of molecular identification. At present, there is no automated, open-source pipeline for determining CCS of analyte ions in both targeted and untargeted fashion, and intensive user-assisted processing with vendor software and manual evaluation is often required. Results We present AutoCCS, an open-source software to rapidly determine CCS values from IMS-MS measurements. We conducted various IMS experiments in different formats to demonstrate the flexibility of AutoCCS for automated CCS calculation: (i) stepped-field methods for drift tube-based IMS (DTIMS), (ii) single-field methods for DTIMS (supporting two calibration methods: a standard and a new enhanced method) and (iii) linear calibration for Bruker timsTOF and non-linear calibration methods for traveling wave based-IMS in Waters Synapt and Structures for Lossless Ion Manipulations. We demonstrated that AutoCCS offers an accurate and reproducible determination of CCS for both standard and unknown analyte ions in various IMS-MS platforms, IMS-field methods, ionization modes and collision gases, without requiring manual processing. Availability and implementation https://github.com/PNNL-Comp-Mass-Spec/AutoCCS. Supplementary information Supplementary data are available at Bioinformatics online. Demo datasets are publicly available at MassIVE (Dataset ID: MSV000085979).

47 OTHER INSTRUMENTATION↗

Laser‐ablation electrospray ionization mass spectrometry with ion mobility separation reveals metabolites in the symbiotic interactions of soybean roots and rhizobia

Summary Technologies enabling in situ metabolic profiling of living plant systems are invaluable for understanding physiological processes and could be used for rapid phenotypic screening (e.g., to produce plants with superior biological nitrogen‐fixing ability). The symbiotic interaction between legumes and nitrogen‐fixing soil bacteria results in a specialized plant organ (i.e., root nodule) where the exchange of nutrients between host and endosymbiont occurs. Laser‐ablation electrospray ionization mass spectrometry ( LAESI ‐ MS ) is a method that can be performed under ambient conditions requiring minimal sample preparation. Here, we employed LAESI ‐ MS to explore the well characterized symbiosis between soybean ( Glycine max L. Merr.) and its compatible symbiont, Bradyrhizobium japonicum . The utilization of ion mobility separation ( IMS ) improved the molecular coverage, selectivity, and identification of the detected biomolecules. Specifically, incorporation of IMS resulted in an increase of 153 differentially abundant spectral features in the nodule samples. The data presented demonstrate the advantages of using LAESI – IMS – MS for the rapid analysis of intact root nodules, uninfected root segments, and free‐living rhizobia. Untargeted pathway analysis revealed several metabolic processes within the nodule (e.g., zeatin, riboflavin, and purine synthesis). Compounds specific to the uninfected root and bacteria were also detected. Lastly, we performed depth profiling of intact nodules to reveal the location of metabolites to the cortex and inside the infected region, and lateral profiling of sectioned nodules confirmed these molecular distributions. Our results established the feasibility of LAESI – IMS – MS for the analysis and spatial mapping of plant tissues, with its specific demonstration to improve our understanding of the soybean‐rhizobial symbiosis.

Stopka, Sylwia A.↗

Non-Destructive Evaluation of Polyolefin Thermal Aging Using Infrared Spectroscopy

Fourier transform infrared (FTIR) spectroscopy is an information-rich method that reveals chemical bonding near the surface of polymer composites. FTIR can be used to verify composite composition, identify chemical contaminants and expose composite moisture content. Polymer matrix changes due to thermal exposure including loss of additives, chain scission, oxidation and changes in crystallinity may also be determined using FTIR spectra. Portable handheld instruments using non-contact reflectance or surface contact attenuated total reflectance (ATR) may be used for non-destructive evaluation (NDE) of thermal aging in polymer and composite materials of in-service components. We report the use of ATR FTIR to track oxidative thermal aging in ethylene-propylene rubber (EPR) and chlorinated polyethylene (CPE) materials used in medium voltage nuclear power plant electrical cable insulation and jacketing. Mechanical property changes of the EPR and CPE materials with thermal degradation for correlation with FTIR data are tracked using indenter modulus (IM) testing. IM is often used as a local NDE metric of cable jacket health. The FTIR-determined carbonyl index was found to increase with IM and may be a valuable NDE metric with advantages over IM for assessing cable remaining useful life.

aging↗

Associations between environmental quality and infant mortality in the United States, 2000–2005

Background: The United States (U.S.) suffers from high infant mortality (IM) rates and there are significant racial/ethnic differences in these rates. Prior studies on the environment and infant mortality are generally limited to singular exposures. We utilize the Environmental Quality Index (EQI), a measure of cumulative environmental exposure (across air, water, land, sociodemographic, and land domains) for U.S. counties from 2000 to 2005, to investigate associations between ambient environment and IM across maternal race/ethnicity. Methods: We linked 2000–2005 infant data from the U.S. Centers for Disease Control and Prevention to the EQI (n = 22,702,529; 144,741 deaths). We utilized multi-level regression to estimate associations between quartiles of county-level EQI and IM. We also considered associations between quartiles of county level domain specific indices with IM. We controlled for rural-urban status (RUCC1: urban, metropolitan; RUCC2: urban, non-metropolitan; RUCC3: less urbanized; RUCC4: thinly populated), maternal age, maternal education, marital status, infant sex, and stratified on race/ethnicity. Additionally, we estimated associations for linear combinations of environmental quality and rural-urban status. Results: We found a mix of positive, negative, and null associations and our findings varied across domain and race/ethnicity. Poorer overall environmental quality was associated with decreased odds among Non-Hispanic whites (OR and 95% CI: EQIQ4 (ref. EQIQ1): 0.84[0.80,0.89]). For Non-Hispanic blacks and Hispanics, some increased odds were observed. Poorer air quality was monotonically associated with increased odds among Non-Hispanic whites (airQ4 (ref. airQ1): 1.05[0.99,1.11]) and blacks (airQ4 (ref. airQ1): 1.09 [0.9,1.31]). Rural status was associated with increased IM odds among Hispanics (RUCC4-Q4:1.36[1.04,1.78]; RUCC1-Q4: 1.04[0.92,1.16], ref. for both RUCC1-Q1). Conclusions: This study is the first to report on associations between ambient environmental quality and IM across the United States. It corroborates prior research suggesting an association between air pollution and IM and identifies residence in thinly populated (rural) areas as a potential risk factor towards IM amongst Hispanics. Some of the counterintuitive findings highlight the need for additional research into potentially differential drivers of environmental quality across the rural-urban continuum, especially with regards to the sociodemographic environment.

60 APPLIED LIFE SCIENCES↗

Issues Management Process Course # 38401

The purpose of this training it to advise Issues Management Coordinators (IMCs) on the revised Contractor Assurance System (CAS) Issues Management (IM) process. Terminal Objectives: Understand the Laboratory’s IM process; Understand your role in the Laboratory’s IM process. Learning Objectives: Describe the IM process within the context of the CAS; Describe the importance of implementing an institutional IM process at LANL; Describe the process flow for the Laboratory’s IM process; Apply the definition of an issue; Use available resources to determine initial screening risk levels for issues; Describe the required major process steps for each risk level; Describe the personnel responsibilities for IM process implementation; Access available resources to support IM process implementation.

99 GENERAL AND MISCELLANEOUS↗

Avionics Configuration Assessment for Flightdeck Interval Management: A Comparison of Avionics and Notification Methods

Flightdeck Interval Management is one of the NextGen operational concepts that FAA is sponsoring to realize requisite National Airspace System (NAS) efficiencies. Interval Management will reduce variability in temporal deviations at a position, and thereby reduce buffers typically applied by controllers - resulting in higher arrival rates, and more efficient operations. Ground software generates a strategic schedule of aircraft pairs. Air Traffic Control (ATC) provides an IM clearance with the IM spacing objective (i.e., the TTF, and at which point to achieve the appropriate spacing from this aircraft) to the IM aircraft. Pilots must dial FIM speeds into the speed window on the Mode Control Panel in a timely manner, and attend to deviations between actual speed and the instantaneous FIM profile speed. Here, the crew is assumed to be operating the aircraft with autothrottles on, with autopilot engaged, and the autoflight system in Vertical Navigation (VNAV) and Lateral Navigation (LNAV); and is responsible for safely flying the aircraft while maintaining situation awareness of their ability to follow FIM speed commands and to achieve the FIM spacing goal. The objective of this study is to examine whether three Notification Methods and four Avionics Conditions affect pilots' performance, ratings on constructs associated with performance (workload, situation awareness), or opinions on acceptability. Three Notification Methods (alternate visual and aural alerts that notified pilots to the onset of a speed target, conformance deviation from the required speed profile, and reminded them if they failed to enter the speed within 10 seconds) were examined. These Notification Methods were: VVV (visuals for all three events), VAV (visuals for all three events, plus an aural for speed conformance deviations), and AAA (visual indications and the same aural to indicate all three of these events). Avionics Conditions were defined by the instrumentation (and location) used to present IM information to crews: (1) Integrated (IM information is embedded in extant PFD (Primary Flight Display), ND (Navigation Display), EICAS (Engine Indicating and Crew Alerting System) displays); (2) EFB_Aft (IM information is only supplied in an EFB and mounted in location similar to that for MITRE's UPS work); (3) EFB_Fore (IM information is only supplied in an EFB which is mounted more forward, under the side window), and (4) EFB_Aft plus use of an AGD (the same IM information is supplied in an EFB and on an AGD, both mounted in locations similar to that in MITRE's UPS work ). Twelve commercial pilot crews flew descent scenarios (VNAV Speed with the mode control panel (MCP) speed window open until flaps extended, then VNAV Path) in a commercial transport flight simulator with realistic visual scene and communications. The results of this study serve three practical aims: (1) contribute to the down-select of avionics configuration for future assessment of the ASTAR spacing algorithm at NASA; (2) provide information useful to the FAA Human Factors Division (ANG-C1)'s mission to identify issues pertinent to flight certification of, and flight standards; (3) identify methodological considerations in support of future FIM human-in-the-loop (HITL) investigations.

Latorella, Kara A.↗

The String Stability of a Trajectory-Based Interval Management Algorithm in the Midterm Airspace

NASA's first Air Traffic Management (ATM) Technology Demonstration (ATD-1) was created to facilitate the transition of mature ATM technologies from the laboratory to operational use. The technologies selected for demonstration are the Traffic Management Advisor with Terminal Metering (TMA-TM), which provides precise time-based scheduling in the terminal airspace; Controller Managed Spacing (CMS), which provides terminal controllers with decision support tools enabling precise schedule conformance; and Interval Management (IM), which consists of flight deck automation that enables aircraft to achieve or maintain a precise spacing interval behind a target aircraft. As the percentage of IM equipped aircraft increases, controllers may provide IM clearances to sequences, or strings, of IM-equipped aircraft. It is important for these strings to maintain stable performance. This paper describes an analytic analysis of the string stability of the latest version of NASA's IM algorithm and a fast-time simulation designed to characterize the string performance of the IM algorithm. The analytic analysis showed that the spacing algorithm has stable poles, indicating that a spacing error perturbation will be reduced as a function of string position. The fast-time simulation investigated IM operations at two airports using constraints associated with the midterm airspace, including limited information of the target aircraft's intended speed profile and limited information of the wind forecast on the target aircraft's route. The results of the fast-time simulation demonstrated that the performance of the spacing algorithm is acceptable for strings of moderate length; however, there is some degradation in IM performance as a function of string position.

Swieringa, Kurt A.↗

System and Method for Providing Visualization Aids for Effective Interval Management Procedure Execution

Methods and apparatus are provided for simulating an interval management (IM) procedure for an ownship aircraft and a target aircraft before the start of the performance of the IM procedure. The method comprises receiving an IM clearance message from air traffic control (ATC), parsing the received IM clearance message into parsed information components identifying the complexity of the IM clearance message based on the number of elements in the information components, generating a flight chart depicting the area over which the proposed IM procedure is to traverse using the mapping information wherein the flight chart includes a vertical view and a plan view, and simulating the IM procedure on the generated flight chart before any steps of the IM procedure are performed.

Kashi, Rajanikanth Nagaraj↗

Image-based modeling of coupled electro-chemo-mechanical behavior of Li-ion battery cathode using an interface-modified reproducing kernel particle method

Abstract An interface-modified reproducing kernel particle method (IM-RKPM) is introduced in this work to allow for a direct model construction from image pixels of heterogeneous polycrystalline Li-ion battery microstructures. The interface-modified reproducing kernel (IM-RK) approximation is constructed through scaling of a kernel function by a regularized distance function in conjunction with strategic placement of interface node locations. This leads to RK shape functions with either weak or strong discontinuities across material interfaces, suitable for modeling various interface mechanics. With the placement of a triple junction node and distance-based scaling of kernel functions, the resulting IM-RK shape function also possesses proper discontinuities at the triple junctions. This IM-RK approximation effectively remedies the well-known Gibb’s oscillation in the smooth approximation of discontinuities. Different from the conventional meshfree approaches for interface discontinuities, this IM-RK approach is done without additional degrees of freedom associated with the enrichment functions, and it is formulated with the standard procedures in the RK shape function construction. This work focuses on identifying the accuracy and convergence properties of IM-RKPM for modeling the coupled electro-chemo-mechanical system. A linear patch test is formulated and numerically tested for the electro-chemo-mechanical coupled problem with a Butler–Volmer boundary condition representing the physical conditions in Li-ion battery microstructures. This is followed by verification of the optimal rates of convergence of IM-RKPM for solving the coupled problem with higher order solutions. The image-based modeling of Li-ion battery microstructures in the numerical examples demonstrates the applicability of the proposed method to realistic Li-ion battery materials modeling.

25 ENERGY STORAGE↗

Comparison of Different Ion Mobility Setups Using Poly (Ethylene Oxide) PEO Polymers: Drift Tube, TIMS, and T-Wave Comparison of Different Ion Mobility Setups Using Poly (Ethylene Oxide) PEO Polymers: Drift Tube, TIMS, and T-Wave

Over the years, polymer analyses using ion mobility-mass spectrometry (IM-MS) measurements have been performed on different ion mobility spectrometry (IMS) setups. In order to be able to compare literature data taken on different IM(-MS) instruments, ion heating and ion temperature evaluations have already been explored. Nevertheless, extrapolations to other analytes are difficult and thus straightforward same-sample instrument comparisons seem to be the only reliable way to make sure that the different IM(-MS) setups do not greatly change the gas-phase behavior. We used a large range of degrees of polymerization (DP) of poly(ethylene oxide) PEO homopolymers to measure IMS drift times on three different IM-MS setups: a homemade drift tube (DT), a trapped (TIMS), and a traveling wave (T-Wave) IMS setup. The drift time evolutions were followed for increasing polymer DPs (masses) and charge states, and they are found to be comparable and reproducible on the three instruments. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of Gas-Phase Ion Mobility Coefficients Using Voltage Sweep Multiplexing

In a standard single averaged, drift tube ion mobility spectrometry (IMS) experiment, typically less than 1% of the ions are utilized, with the rest of the ions neutralizing on a closed ion gate or ion optic element. Though some efforts at lower pressures (e.g., 4 Torr) have been made to address this issue by concentrating ions prior to release into a drift cell, the ion current reaching the detector during an IMS experiment is often diminished due to this lower duty cycle. Additionally, when considering the temporal nature of the drift tube IMS experiment and the trajectory of IMS towards higher resolution separations and lower duty cycles, increased detector sampling rates are another factor also which further necessitates new modes of conducting the IMS experiment. Placing this trend in context with ion mobility-mass spectrometry instruments (IM-MS), there are numerous types of mass spectrometers that are simply incompatible with the single averaged ion mobility spectrometry experiments due to timing incompatibilities (i.e., ion traps are an order of magnitude slower than the IMS experiment). However, by utilizing a dual gate ion mobility spectrometer for ion multiplexing, ion utilization efficiency can be significantly increased while creating a measurement signal that can be recorded at low sampling rates. In this work, we present the fundamental theory and first results from proof-of-concept measurements using a new type of ion multiplexing that relies on changing the electric field within the drift cell during the course of an experiment while simultaneously opening the ion gates at a constant frequency. For brevity, this mode is termed voltage sweep multiplexing (VSM). Key variables for this type of experiment are discussed and verified with measurements from traditional signal averaged experiments. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Editorial overview: Omics

The great complexity of biological systems and their environment poses similarly vast challenges for accurate analytical evaluations of their identity, structure and quantity. Post genomic science, has predicted much regarding the static populations of biological systems, but a further challenge for analysis is to test the accuracy of these predictions, as well as provide a better representation of the transient nature of the molecules of life. Accurate measurements of biological systems have wide applications for biological, forensic, biotechnological and healthcare fields. Therefore, the holy grail is to find a technique which can identify and quantify biological molecules with high throughput, sensitivity and robustness, as well evaluate molecular structure(s) in order to understand how the specific molecules interact and function. While wrapping all of these characteristics into one platform may sound difficult, ion mobility spectrometry (IMS) is addressing all of these challenges. Over the last decade, the number of analytical studies utilizing IMS for the evaluation of complex biological and environmental samples has greatly increased. In most cases IMS is coupled with mass spectrometry (IM-MS), but even alone IMS provides the unique capability of rapidly assessing a molecule’s structure, which can be extremely difficult with other techniques. The robustness of the IMS measurement is bourne out by its widespread use in security, environmental and military applications. The multidimensional IM-MS measurements however have been proven to be ever more powerful, as applied to complex mixtures as they enable the evaluation of both the structure and mass of every molecular component in a sample during a single measurement, without the need for continual reference calibration.

Barran, Perdita↗

Growth kinetics of Al–Fe intermetallic compounds during annealing treatment of friction stir lap welds

In this study, we explored the growth kinetics of the Al–Fe intermetallic (IM) layer at the joint interface of the St-12/Al-5083 friction stir lap welds during post-weld annealing treatment at 350, 400 and 450 °C for 30 to 180 min. Optical microscope (OM), field emission gun scanning electron microscope (FEG-SEM) and transmission electron microscope (TEM) were employed to investigate the structure of the weld zone. The thickness and composition of the IM layers were evaluated using image analysis system and electron back-scatter diffraction (EBSD), respectively. Moreover, kernel average misorientation (KAM) analysis was performed to evaluate the level of stored energy in the as-welded state. The results showed that the growth kinetics of the IM layer was not governed by a parabolic diffusion law. Presence of the IM compounds as well as high stored energy near the joint interface of the as-welded sample was recognized to be the origin of the observed deviation from the parabolic diffusion law. - Highlights: • This work provided a new insight into growth kinetics of Al–Fe IM thickness. • The growth kinetics of IM layer was not governed by a parabolic diffusion law. • IM near the joint interface was the origin of deviation from the parabolic law. • High stored energy at joint interface was origin of deviation from parabolic law.

36 MATERIALS SCIENCE↗

Ion mobility spectrometry and the omics: Distinguishing isomers, molecular classes and contaminant ions in complex samples

Ion mobility spectrometry (IMS) is a widely used analytical technique providing rapid gas phase separations. IMS alone is useful, but its coupling with mass spectrometry (IMS-MS) and various front-end separation techniques has greatly increased the molecular information achievable from omic analyses, including the sensitivity and peak capacity extracted from complex biological and environmental sample analyses. Due to these characteristics, IMS-MS is rapidly gaining attention for improving metabolomic, lipidomic, glycomic, proteomic and exposomic analyses. Numerous studies including national security-related analyses, disease screenings and environmental evaluations are illustrating that IMS-MS is able to extract information not possible with MS alone. Furthermore, IMS-MS has shown great utility in salvaging molecular information for low abundance molecules of interest when high concentration contaminant ions are present in the sample. This review highlights how IMS-MS is currently being used in omic analyses to distinguish structurally similar molecules, isomers, molecular classes and contaminant ions.

Ion mobility spectrometry,, Mass Spectometry, Omic↗

Improved Sensitivity and Separations for Phosphopeptides using Online Liquid Chromotography Coupled with Structures for Lossless Ion Manipulations Ion Mobility–Mass Spectrometry

Phosphoproteomics greatly augments proteomics and holds tremendous potential for insights into the modulation of biological systems for various disease states, etc. However, numerous challenges hinder conventional methods in terms of measurement sensitivity, throughput, and capabilities for confident phosphopeptide and phosphosite identification. In this work, we report the first example of integrating structures for lossless ion manipulations ion mobility (SLIM) IM-MS with online reversed-phase liquid chromatography (LC) to evaluate its potential for addressing the aforementioned challenges. A mixture of 51 heavy-labeled phosphopeptides was analyzed with a SLIM IM module having integrated ion accumulation and long-path separation regions. The SLIM IM-MS provided improved sensitivity over an established LC-SRM method, with limits of detection as low as 50 pM (50 amol/µl) for several peptides. Conventionally problematic phosphopeptide isomers could be resolved following an 18 m SLIM IM separation. The 2-D peak capacity was estimated as ~9000 for 90 min LC separation coupled to an 18 m SLIM IM separation, considerably higher than LC alone and providing a basis for both improved identification and quantification, with additional gains projected with the future use of longer path SLIM IM separations. Thus, LC-SLIM IM-MS offers great potential for improving the sensitivity, separation, and throughput of phosphoproteomics analyses.

Chouinard, Christopher D.↗

Anhydrous vs Hydrated f-Element Acetate Polymers Dictated by the Stoichiometry of Protic Acidic/Basic Azole Mixtures

Continuing our investigations of ionic liquid (IL) based routes to a library of f-element/soft donor complexes which could be studied crystallographically, we have explored the dissolution of f-element salts in protic imidazole-based ILs containing only soft donors at high temperatures to drive off volatiles, including water and carboxylic or mineral acids. Here we present our results, reacting acidic and basic azoles in 1:3 or 1:1 stoichiometric compositions at elevated temperature, followed by saturation with Nd(OAc) 3 ·xH 2 O or Ce(OAc) 3 ·xH 2 O, which led to 13 new metal–acetate polymeric complexes identified by single-crystal X-ray diffraction. We found that the diversity in coordination modes of the simple acetate ligand that interfere with substitution of the softer N donors led to several readily crystallizable complexes forming two distinct groups with respect to f-element interaction with the ionic liquid precursors. When the acidic/basic azole ratio was 1:3, acetate and a neutral basic azole were found to be coordinated to the metal centers but no water, although in one case (2) water was observed in the secondary coordination sphere: [Ce(μ 2 -OAc) 3 (C 1 im)] n (1, C 1 im = 1-methylimidazole), [Nd(μ 2 -(OAc) 3 (C 1 im)] n ·nH 2 O (2), [Ce(μ 2 -OAc) 3 (C 2 im)] n (3, C 2 im = 1-ethylimidazole), [Ln(μ 2 -OAc) 3 DMF] n (Ln = Nd (4), Ce (5); dimethylformamide (DMF) was substituted for the azole mixture), and [Nd(μ 2 -OAc) 3 (C 4 im)] n (6, C 4 im = 1-butylimidazole). However, when the stoichiometric ratio was 1:1, water was always observed coordinated to the metal ions with the acidic azole included in the structure as a solvate or cocrystal, despite a higher reaction temperature: [Nd(μ 2 -OAc) 3 (OH 2 )] n ·n(1,2,3-Taz) (7, 1,2,3-Taz = 1,2,3-triazole), [Ln(μ 2 -OAc) 3 (OH 2 )] n ·n(4,5-DCim) (Ln = Nd (8), Ce (9), 4,5-DCim = 4,5-dicyanoimidazole), [Ln(μ 2 -OAc) 3 (OH 2 )] n ·n(3,5-diNH 2 -1,2,4-Taz) (Ln = Nd (10), Ce (11), 3,5-diNH 2 -1,2,4-Taz = 3,5-diamino-1,2,4-triazole), [Ce(μ 2 -OAc) 3 (OH 2 )] n ·n(3-NH 2 -1,2,4-Taz) (12, 3-NH 2 -1,2,4-Taz = 3-amino-1,2,4-triazole), and [Nd(μ 2 -OAc) 3 (OH 2 )] n ·n(5-NH 2 -Tz) (13, 5-NH2-Tz = 5-aminotetrazole). All of the compounds retain the Ln:OAc– ratio of 1:3 and form 1D polymeric chains; however, they exhibit a variety of coordination modes affecting the degree of chain condensation. The isolation of both hydrated and anhydrous products revealed different abilities of the investigated soft N-donors to compete with O-donors finding their place in the coordination sphere of the lanthanide or in the crystal lattice.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of a Reference-Free Collision Cross Section Calibration Strategy for Proteomics Using SLIM-Based High-Resolution Ion Mobility Spectrometry–Mass Spectrometry

Ion mobility spectrometry (IMS) is a gas-phase analytical technique that separates ions with different sizes and shapes and is compatible with mass spectrometry (MS) to provide an additional separation dimension. The rapid nature of the IMS separation combined with the high sensitivity of MS-based detection and the ability to derive structural information on analytes in the form of the property collision cross section (CCS) makes IMS particularly well-suited for characterizing complex samples in -omics applications. In such applications, the quality of CCS from IMS measurements is critical to confident annotation of the detected components in the complex -omics samples. However, most IMS instrumentation in mainstream use requires calibration to calculate CCS from measured arrival times, with the most notable exception being drift tube IMS measurements using multifield methods. The strategy for calibrating CCS values, particularly selection of appropriate calibrants, has important implications for CCS accuracy, reproducibility, and transferability between laboratories. The conventional approach to CCS calibration involves explicitly defining calibrants ahead of data acquisition and crucially relies upon availability of reference CCS values. In this work, we present a novel reference-free approach to CCS calibration which leverages trends among putatively identified features and computational CCS prediction to conduct calibrations post-data acquisition and without relying on explicitly defined calibrants. We demonstrated the utility of this reference-free CCS calibration strategy for proteomics application using high-resolution structures for lossless ion manipulations (SLIM)-based IMS-MS. In conclusion, we first validated the accuracy of CCS values using a set of synthetic peptides and then demonstrated using a complex peptide sample from cell lysate.

59 BASIC BIOLOGICAL SCIENCES↗

Surface directed reversible imidazole ligation to nickel(ii) octaethylporphyrin at the solution/solid interface: a single molecule level study

Scanning tunneling microscopy (STM) is used to study for the first time the reversible binding of imidazole (Im) and nickel(II) octaethylporphyrin (NiOEP) supported on highly oriented pyrolytic graphite (HOPG) at the phenyloctane/NiOEP/HOPG interface at 25 °C. The ligation of Im to the NiOEP receptor while not observed in fluid solution is readily realized at the solution/HOPG interface. The coordination process scales with increasing Im concentration and can be effectively modeled by the Langmuir isotherm. At room temperature it is determined that the standard free energy of adsorption is ΔG c = -15.8 kJ mol -1 and the standard enthalpy of adsorption is estimated to be ΔH c ≈ -80 kJ mol -1 . The reactivity of imidazole toward NiOEP adsorbed on HOPG is attributed to charge donation from the graphite stabilizing the Im–Ni bond. This charge transfer pathway is supported by molecular and periodic modeling calculations which indicate that the Im ligand behaves as a π-acceptor. DFT calculations also show that the nickel ion in the Im–NiOEP/HOPG complex is in a singlet ground state. This is surprising since both our calculations and previous experimental studies find a triplet ground state for the five and six coordinated Im–nickel(II) porphyrins in the gas-phase or in solution. Both the experimental and the theoretical findings provide information that is useful for better understanding of chemical sensing/recognition and catalytic processes that utilize metal–organic complexes adsorbed on surfaces where the reactivity of the metal is moderated by the substrate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗