At least 343 records · Page 19

Microwave Soil Moisture Retrieval Under Trees

Soil moisture is recognized as an important component of the water, energy, and carbon cycles at the interface between the Earth's surface and atmosphere. Current baseline soil moisture retrieval algorithms for microwave space missions have been developed and validated only over grasslands, agricultural crops, and generally light to moderate vegetation. Tree areas have commonly been excluded from operational soil moisture retrieval plans due to the large expected impact of trees on masking the microwave response to the underlying soil moisture. Our understanding of the microwave properties of trees of various sizes and their effect on soil moisture retrieval algorithms at L band is presently limited, although research efforts are ongoing in Europe, the United States, and elsewhere to remedy this situation. As part of this research, a coordinated sequence of field measurements involving the ComRAD (for Combined Radar/Radiometer) active/passive microwave truck instrument system has been undertaken. Jointly developed and operated by NASA Goddard Space Flight Center and George Washington University, ComRAD consists of dual-polarized 1.4 GHz total-power radiometers (LH, LV) and a quad-polarized 1.25 GHz L band radar sharing a single parabolic dish antenna with a novel broadband stacked patch dual-polarized feed, a quad-polarized 4.75 GHz C band radar, and a single channel 10 GHz XHH radar. The instruments are deployed on a mobile truck with an 19-m hydraulic boom and share common control software; real-time calibrated signals, and the capability for automated data collection for unattended operation. Most microwave soil moisture retrieval algorithms developed for use at L band frequencies are based on the tau-omega model, a simplified zero-order radiative transfer approach where scattering is largely ignored and vegetation canopies are generally treated as a bulk attenuating layer. In this approach, vegetation effects are parameterized by tau and omega, the microwave vegetation opacity and single scattering albedo. One goal of our current research is to determine whether the tau-omega model can work for tree canopies given the increased scatter from trees compared to grasses and crops, and. if so, what are effective values for tau and omega for trees.

O'Neill, P.↗

Composite separators and redox flow batteries based on porous separators

Composite separators having a porous structure and including acid-stable, hydrophilic, inorganic particles enmeshed in a substantially fully fluorinated polyolefin matrix can be utilized in a number of applications. The inorganic particles can provide hydrophilic characteristics. The pores of the separator result in good selectivity and electrical conductivity. The fluorinated polymeric backbone can result in high chemical stability. Accordingly, one application of the composite separators is in redox flow batteries as low cost membranes. In such applications, the composite separator can also enable additional property-enhancing features compared to ion-exchange membranes. For example, simple capacity control can be achieved through hydraulic pressure by balancing the volumes of electrolyte on each side of the separator. While a porous separator can also allow for volume and pressure regulation, in RFBs that utilize corrosive and/or oxidizing compounds, the composite separators described herein are preferable for their robustness in the presence of such compounds.

25 ENERGY STORAGE↗

Effect of Initial Water Saturation on The Performance of Fracturing Fluids With and Without Polyallylamine under Simulated EGS Conditions

Objectives/Scope: StimuFrac (US Patents 9,873,828 B2 and 9,447,315 B2), a CO2-reactive polymer aqueous solution [polyallylamine (PAA) 1wt% in water] combined with CO2, can be used as a less water-intensive fracturing fluid for enhanced geothermal systems (EGS). Our previous results show that in hot dry rock (HDR), PAA/CO2 fracturing fluids outperformed other fluids such as water, CO2, and CO2/water in generating large fractures with less fluid consumed. The objective of this work is to study the effect of initial water saturation of rock on the performance of StimuFrac fluid in ½ foot cubic rock samples and under representative EGS pressure/temperature conditions using cyclic and constant flow rate injection strategies. The fracturing results are compared with results using different fracturing fluids in terms of controlling fracture propagation rates, fracture hydraulic conductivity, breakdown pressures and volumes of fluids required. Methods/Procedures/Process: In all tests, water was initially injected into the rock to increase the water saturation before the fracturing processes to simulate actual geothermal reservoir conditions. For the cyclic injection, one complete cycle consisted of (1) a PAA slug (or water slug) injection followed by (2) CO2 injection to initiate the fracture. In the second step of the first cycle, the pressure of CO2 is increased until a maximum pressure is reached (fracture is initiated at this moment), and then the injection of CO2 is allowed for another 30 seconds to propagate the fracture. Then, the two-step cycle of PAA followed by CO2 injection (up to 2-4 mL/min) was continued. For the constant flow rate injection strategies, the initial water saturation was increased by injecting water at 1000 psi and 200°C for three days. After that, an initial slug of water, CO2, or PAA was injected and then fracturing was initiated and propagated by injecting CO2 at a constant flow rate. Applications/Significance/Novelty: The results of this study suggest that water saturation, especially near the wellbore region, will significantly affect the fracturing fluid transmission into the rock porous media by changing the relative permeability of CO2 or water, thus affecting the fracture initiation and propagation. In this study, fracturing with cyclic injection or constant flow rate injection methods were performed using three different kinds of fluids systems. These fluids are water, CO2, or CO2 with PAA. Splitting the rock samples in half after fracturing reveals that the fracture propagation is significantly limited under these high water saturated conditions compared to dry initial conditions: The fractures propagate less than 1/3 length of the distance from the wellbore to rock surface, and in some cases no fracture is generated. This may be caused by the fact that leak-off is dominating the fracturing process and the injected fluid flow rate is not high enough to overcome the leak-off even under high flow rate injection conditions. Additionally, CO2 could be leaking off into the wellbore annulus and this may be making it more difficult to generate pressure gradients away from the near-wellbore region.

Jian, Guoqing↗

The Role of Technical Guidance and Analysis Tools in Remedy Decisions, Implementation, and Closure - 18307

Selection, design, and implementation of environmental remedies are conducted under regulatory frameworks that define the activities, communication, and documentation requirements for the remediation process. However, there are site situations that are not well described in the basic regulatory frameworks, and technical guidance and analysis tools can help facilitate remedy decisions and actions. An example where technical guidance and analysis tools are helpful is in the transition from pump-and-treat (P and T) remediation to monitored natural attenuation (MNA). Standard MNA regulatory guidance does not account for a plume initially controlled by P and T hydraulic conditions rather than natural-gradient conditions. For instance, MNA guidance discusses demonstrating plume stability as a means to evaluate the suitability of MNA. However, plume stability under long-term natural gradient conditions cannot be directly demonstrated while the plume is being contained by a P and T system. Thus, additional guidance is needed to describe other measures that can be used to support transition from P and T to MNA. As an additional example, standard MNA regulatory guidance is not written to provide suitable information for application to vadose-zone contamination; discussion and examples in the regulatory guidance are predominantly for groundwater. Use of contaminant transport assessments is an important component of vadose-zone remedy decisions where technical guidance and analysis tools can facilitate these decisions. For volatile compounds, the assessment may need to also consider flux to the surface and constraints associated with vapor intrusion. Recent technical guidance and associated analysis tools provide sites with approaches to support remedy decisions for the above conditions. In particular, these recent approaches target developing and implementing P and T and soil vapor extraction remediation exit strategies and facilitating assessment and implementation of remedies for coupled vadose-zone/groundwater contamination. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Physical and hydraulic properties of modern sinter deposits: El Tatio, Atacama

We report sinters are siliceous, sedimentary deposits that form in geothermal areas. Formation occurs in two steps. Hot water circulates in the subsurface and dissolves silica from the host rock, usually rhyolites. Silica then precipitates after hot water is discharged and cools. Extensive sinter formations are linked to up-flow areas of fluids originating from high temperature (> 175 °C) deep reservoirs. Fluid geochemistry, microbial communities, and environmental conditions of deposition determine the texture of sinter and pore framework. Porosity strongly influences physical and hydraulic properties of rocks. To better understand the properties controlling the transport of fluids, and interpret geophysical observations in geothermal systems, here we studied 17 samples of modern geyserite sinter deposits (< 10 ka) from the active El Tatio geothermal field in northern Chile. We measured the physical properties (hydraulic, seismic, and electrical), and internal microstructure (using μX-Ray computed tomography). We find that the pore structure, and thus hydraulic and physical properties, is controlled by the distribution of microbial matter. Based on velocity-porosity relationships, permeability-porosity scaling, and image analysis of the 3D pore structure; we find that the physical and hydraulic properties of sinter more closely resemble those of vesicular volcanic rocks and other material formed by precipitation in geothermal settings (i.e., travertine) than clastic sedimentary rocks.

15 GEOTHERMAL ENERGY↗

Analysis of BWR OPRM plant data and detection algorithms with DSSPP

All U.S. BWRs are required to have licensed stability solutions that satisfy General Design Criteria (GDC) 10 and 12 of 10 CFR 50 Appendix A. Implemented solutions are either detect and suppress or preventive in nature. Detection and suppression of power oscillations is accomplished by specialized hardware and software such as the Oscillation Power Range Monitor (OPRM) utilized in Option III and Detect and Suppress Solution - Confirmation Density (DSS-CD) stability Long-Term Solutions (LTSs). The detection algorithms are designed to recognize a Thermal-Hydraulic Instability (THI) event and initiate control rod insertion before the power oscillations increase much higher above the noise level that may threaten the fuel integrity. Option III is the most widely used long-term stability solution in the US and has more than 200 reactor years of operational history. DSS-CD represents an evolutionary step from the stability LTS Option III and its licensed domain envelopes the Maximum Extended Load Line Limit Analysis Plus (MELLLA +) domain. In order to enhance the capability to investigate the sensitivity of key parameters of stability detection algorithms, GEH has developed a new engineering analysis code, namely DSSPP (Detect and Suppress Solution Post Processor), which is introduced in this paper. The DSSPP analysis tool represents a major advancement in the method for diagnosing the design of stability detection algorithms that enables designers to perform parametric studies of the key parameters relevant for THI events and to fine tune these system parameters such that a potential spurious scram might be avoided. Demonstrations of DSSPPs application are also presented in this paper utilizing actual plant THI data. A BWR/6 plant had a plant transient that included unplanned recirculation pump transfer from fast to slow speed resulting in about 100% to {approx}40% rated power decrease and about 99% to {approx}30% rated core flow decrease. As the feedwater temperature is reduced to equilibrium conditions, the power increased from about {approx}40% to about {approx}60% with little change inflow. A THI event developed and subsequently, an OPRM initiated scram occurred with Option III. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A simulation-based study on different control strategies for variable speed pump in distributed ground source heat pump systems

Most commercial ground source heat pump systems (GSHP) in the United States are in a distributed configuration. These systems circulate water or an anti-freeze solution through multiple heat pump units via a central pumping system, which usually uses variable speed pump(s). Variable speed pumps have potential to significantly reduce pumping energy use; however, the energy savings in reality could be far away from its potential due to improper pumping system design and controls. In this paper, a simplified hydronic pumping system was simulated with the dynamic Modelica models to evaluate three different pumping control strategies. This includes two conventional control strategies, which are to maintain a constant differential pressure across either the supply and return mains, or at the most hydraulically remote heat pump; and an innovative control strategy, which adjusts system flow rate based on the demand of each heat pump. The simulation results indicate that a significant overflow occurs at part load conditions when the variable speed pump is controlled to main a constant differential pressure across the supply and return mains of the piping system. On the other hand, an underflow occurs at part load conditions when the variable speed pump is controlled to maintain a constant differential pressure across the furthest heat pump. The flow-demand-based control can provide needed flow rate to each heat pump at any given time, and with less pumping energy use than the two conventional controls. Finally, a typical distributed GSHP system was studied to evaluate the energy saving potential of applying the flow-demand-based pumping control strategy. This case study shows that the annual pumping energy consumption can be reduced by 62% using the flow-demand-based control compared with that using the conventional pressure-based control to maintain a constant differential pressure a cross the supply and return mains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Corrigendum to "Environmentally friendly, rheoreversible, hydraulic fracturing fluids for enhanced geothermal systems" [Geothermics 58 (2015) 22–31]

Cost-effective creation of high-permeability reservoirs inside deep crystalline bedrock is the primary challenge for the feasibility of enhanced geothermal systems (EGS). Current reservoir stimulation entails adverse environmental impacts and substantial economic costs due to the utilization of large volumes of water “doped” with chemicals including rheology modifiers, scale and corrosion inhibitors, biocides, friction reducers among others where, typically, little or no information of composition and toxicity is disclosed. An environmentally benign, CO2-activated, rheoreversible fracturing fluid has recently been developed that significantly enhances rock permeability at effective stress significantly lower than current technology. We evaluate the potential of this novel fracturing fluid for application on geothermal sites under different chemical and geomechanical conditions, by performing laboratory-scale fracturing experiments with different rock sources under different confining pressures, temperatures, and pH environments. The results demonstrate that CO2-reactive aqueous solutions of environmentally amenable Polyallylamine (PAA) represent a highly versatile fracturing fluid technology. This fracturing fluid creates/propagates fracture networks through highly impermeable crystalline rock at significantly lower effective stress as compared to control experiments where no PAA was present, and permeability enhancement was significantly increased for PAA compared to conventional hydraulic fracturing controls. This was evident in all experiments, including variable rock source/type, operation pressure and temperature (over the entire range for EGS applications), as well as over a wide range of formation-water pH values. This versatile novel fracturing fluid technology represents a great alternative to industrially available fracturing fluids for cost-effective and competitive geothermal energy production.

Shao, Hongbo↗

Electronics plus fluidics for V/STOL flight control

The redundant digital fly by wire flight control system coupled with a fluidic system, which uses hydraulic pressure as its signal transmission means to provide pilot and feedback sensor control of airframe forcing functions is considered for application to the V/STOL aircraft. A potential fluidics system is introduced, and anticipated performance, weight, and reliability is discussed. Integration with the redundant electronic channels is explored, with the safety and mission reliability of alternate configurations estimated.

Hendrick, R. C.↗

Methods and apparatus for handling or treating particulate material

An improved draft tube spout fluid bed (DTSFB) mixing, handling, conveying, and treating apparatus and systems, and methods for operating are provided. The apparatus and systems can accept particulate material and pneumatically or hydraulically conveying the material to mix and/or treat the material. In addition to conveying apparatus, a collection and separation apparatus adapted to receive the conveyed particulate material is also provided. The collection apparatus may include an impaction plate against which the conveyed material is directed to improve mixing and/or treatment. The improved apparatus are characterized by means of controlling the operation of the pneumatic or hydraulic transfer to enhance the mixing and/or reacting by controlling the flow of fluids, for example, air, into and out of the apparatus. The disclosed apparatus may be used to mix particulate material, for example, mortar; react fluids with particulate material; coat particulate material, or simply convey particulate material.

Littman, Howard↗

Waste Water Treatment Apparatus and Methods

An improved draft tube spout fluid bed (DTSFB) mixing, handling, conveying, and treating apparatus and systems, and methods for operating are provided. The apparatus and systems can accept particulate material and pneumatically or hydraulically conveying the material to mix and/or treat the material. In addition to conveying apparatus, a collection and separation apparatus adapted to receive the conveyed particulate material is also provided. The collection apparatus may include an impaction plate against which the conveyed material is directed to improve mixing and/or treatment. The improved apparatus are characterized by means of controlling the operation of the pneumatic or hydraulic transfer to enhance the mixing and/or reacting by controlling the flow of fluids, for example, air, into and out of the apparatus. The disclosed apparatus may be used to mix particulate material, for example, mortar; react fluids with particulate material; coat particulate material, or simply convey particulate material.

Littman, Howard↗

Design and Application of CSC-Roll for Heavy Reduction of the Bloom Continuous Casting Process

Center quality control is a key issue affecting large-section bloom production and product quality. The central convex roll could avoid the bloom side part and yield a high reduction amount, which benefit the implement of heavy reduction (HR) for bloom continuous casting process without upgrading the mechanical and hydraulic system of withdrawal and straightening machine. In this work, a curving surface convex roll (CSC-Roll), which could significantly improve bloom center quality, was designed by finite element simulation for a 360 mm × 450 mm #45 steel continuous casting bloom. The optimal roll surface shape of the CSC-Roll was determined based on an analysis of the distribution of the reduction amount in the bloom center and the strain of the bloom centerline and inner surface. The calculation results showed that the optimal size of the CSC-Roll was 200 mm in convex platform region length, 30 mm in convex platform region height, and 80 mm in gradient curvature region length. The bloom heat transfer and deformation behavior in the CSC-Roll reduction process were then analyzed. The results showed that in the CSC-Roll HR process, 61.71 pct of the reduction amount could be transmitted to the inner side of the porosity zone. Macrographs of the 360 mm × 450 mm #45 steel continuous casting bloom proved that the bloom center quality was significantly improved after CSC-Roll HR was applied.

36 MATERIALS SCIENCE↗

Control rod modeling in liquid metal-cooled fast reactors

Control rod modeling in Liquid Metal-cooled Fast Reactors (LMFRs) is important for an accurate simulation, especially in depletion calculations. Recently, control rod search and cusping models have been added to the LUPINE multiphysics fast reactor simulator. LUPINE stands for the 'LMFR Utility for Physics Informed Nuclear Engineering' and is currently being developed at North Carolina State University. LUPINE models the coupled multiphysics effects in LMFRs, including neutronics, thermal hydraulics, thermal expansion, and depletion. The control rod search has been implemented using a Newton-secant search in an inexact-Newton iteration and the cusping model uses a polynomial technique to correct for control rod cusping. The control rod cusping and search models were demonstrated by modeling the Advanced Burner Reactor (ABR) MET-1000 Sodium-cooled Fast Reactor (SFR) and a long-life Lead-cooled Fast Reactor (LFR) based on a Westinghouse Electric Company, LLC (WEC) design. A differential control rod worth curve was calculated for both reactor models to demonstrate the control rod cusping model. The SFR and LFR models were used to demonstrate the importance of modeling control rod movement during depletion calculations and the adverse effect of control rods on cycle length is demonstrated. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Measuring a Low Horizontal Hydraulic Gradient in a High Transmissivity Aquifer

Abstract High transmissivity aquifers typically have low hydraulic gradients (i.e., a flat water table). Measuring low gradients using water levels can be problematic because measurement error may be greater than the true difference in water levels (i.e., a low signal‐to‐noise ratio). In this study, the feasibility of measuring a hydraulic gradient in the range of 10 −6 to 10 −5 m/m was demonstrated. The study was performed at a site where the depth to water from land surface ranged from 40.1 to 94.2 m and the aquifer transmissivity was estimated at 41,300 m 2 /d (hydraulic conductivity of 18,800 m/d). The goals of the study were to reduce measurement error as much as practicable and assess the importance of factors affecting water level measurement accuracy. Well verticality was the largest source of error (0.000 to 0.168 m; median of 0.014 m), and geodetic survey of casing elevations was the next most important source of error (0.002 to 0.013 m; median of 0.005 m). Variability due to barometric pressure fluctuations was not an important factor at the site. Hydraulic heads were measured to an accuracy of ±0.0065 m, and the average hydraulic gradient was estimated to be 8.0 × 10 −6 (±0.9 × 10 −6 ) m/m. The improvement in accuracy allowed for two reversals in the groundwater flow direction to be identified, after which the gradient averaged 2.5 × 10 −5 (±0.4 × 10 −5 ) m/m. This study showed it is possible to sufficiently control sources of error to measure hydraulic gradients in the 10 −6 to 10 −5 m/m range.

McDonald, John P.↗

Prolonged experimental drought reduces plant hydraulic conductance and transpiration and increases mortality in a piñon–juniper woodland

Abstract Plant hydraulic conductance ( k s ) is a critical control on whole‐plant water use and carbon uptake and, during drought, influences whether plants survive or die. To assess long‐term physiological and hydraulic responses of mature trees to water availability, we manipulated ecosystem‐scale water availability from 2007 to 2013 in a piñon pine ( Pinus edulis ) and juniper ( Juniperus monosperma ) woodland. We examined the relationship between k s and subsequent mortality using more than 5 years of physiological observations, and the subsequent impact of reduced hydraulic function and mortality on total woody canopy transpiration ( E C ) and conductance ( G C ). For both species, we observed significant reductions in plant transpiration ( E ) and k s under experimentally imposed drought. Conversely, supplemental water additions increased E and k s in both species. Interestingly, both species exhibited similar declines in k s under the imposed drought conditions, despite their differing stomatal responses and mortality patterns during drought. Reduced whole‐plant k s also reduced carbon assimilation in both species, as leaf‐level stomatal conductance ( g s ) and net photosynthesis ( A n ) declined strongly with decreasing k s . Finally, we observed that chronically low whole‐plant k s was associated with greater canopy dieback and mortality for both piñon and juniper and that subsequent reductions in woody canopy biomass due to mortality had a significant impact on both daily and annual canopy E C and G C . Our data indicate that significant reductions in k s precede drought‐related tree mortality events in this system, and the consequence is a significant reduction in canopy gas exchange and carbon fixation. Our results suggest that reductions in productivity and woody plant cover in piñon–juniper woodlands can be expected due to reduced plant hydraulic conductance and increased mortality of both piñon pine and juniper under anticipated future conditions of more frequent and persistent regional drought in the southwestern United States.

54 ENVIRONMENTAL SCIENCES↗

Quantifying the Impact of Lagged Hydrological Responses on the Effectiveness of Groundwater Conservation

Many irrigated agricultural areas seek to prolong the lifetime of their groundwater resources by reducing pumping. However, it is unclear how lagged responses, such as reduced groundwater recharge caused by more efficient irrigation, may impact the long-term effectiveness of conservation initiatives. Here, we use a variably saturated, simplified surrogate groundwater model to: 1) analyze aquifer responses to pumping reductions, 2) quantify time lags between reductions and groundwater level responses, and 3) identify the physical controls on lagged responses. We explore a range of plausible model parameters for an area of the High Plains Aquifer (USA) where stakeholder-driven conservation has slowed groundwater depletion. We identify two types of lagged responses that reduce the long-term effectiveness of groundwater conservation, recharge-dominated and lateral-flow-dominated, with vertical hydraulic conductivity (K Z ) the major controlling variable. When high K z allows percolation to reach the aquifer, more efficient irrigation reduces groundwater recharge. By contrast, when low K z impedes vertical flow, short term changes in recharge are negligible, but pumping reductions alter the lateral flow between the groundwater conservation area and the surrounding regions (lateral-flow-dominated response). For the modeled area, we found that a pumping reduction of 30% resulted in median usable lifetime extensions of 20 or 25 years, depending on the dominant lagged response mechanism (recharge- vs. lateral-flow-dominated). These estimates are far shorter than estimates that do not account for lagged responses. To conclude, results indicate that conservation-based pumping reductions can extend aquifer lifetimes, but lagged responses can create a sizable difference between the initially perceived and actual long-term effectiveness.

54 ENVIRONMENTAL SCIENCES↗

Flight Test of the F/A-18 Active Aeroelastic Wing Airplane

Successful flight-testing of the Active Aeroelastic Wing airplane was completed in March 2005. This program, which started in 1996, was a joint activity sponsored by NASA, Air Force Research Laboratory, and industry contractors. The test program contained two flight test phases conducted in early 2003 and early 2005. During the first phase of flight test, aerodynamic models and load models of the wing control surfaces and wing structure were developed. Design teams built new research control laws for the Active Aeroelastic Wing airplane using these flight-validated models; and throughout the final phase of flight test, these new control laws were demonstrated. The control laws were designed to optimize strategies for moving the wing control surfaces to maximize roll rates in the transonic and supersonic flight regimes. Control surface hinge moments and wing loads were constrained to remain within hydraulic and load limits. This paper describes briefly the flight control system architecture as well as the design approach used by Active Aeroelastic Wing project engineers to develop flight control system gains. Additionally, this paper presents flight test techniques and comparison between flight test results and predictions.

Clarke, Robert↗