Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High resolution X ray spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Calcium-Uranyl-Carbonato Species Kinetically Limit U(VI) Reduction by Fe(II) and Lead to U(V)-Bearing Ferrihydrite

Reaction conditions and mechanisms promoting or inhibiting U reduction exert a central control on U solubility and, therefore, U transport and its associated risks. Here, we vary and track common aqueous uranium species to show that a kinetic restriction inhibits homogeneous reduction of the calcium-uranyl-carbonato species (CaUO$_2$(CO$_3$)$_3$$^{2–}$ and Ca$_2$UO$_2$(CO$_3$)$_3$) by Fe(II)$_{(aq)}$, while ferrihydrite surface-catalyzed reduction of all aqueous uranyl by Fe(II) proceeds. Using U L$_3$ high energy resolution fluorescence detection (HERFD) X-ray absorption near edge structure (XANES) spectroscopy, U L$_3$ extended X-ray absorption fine structure (EXAFS) spectroscopy, and transmission electron microscopy (TEM), we also show that U(V) is generated and incorporated into ferrihydrite formed from homogeneous U(VI) reduction by Fe(II)(aq). Through elucidation of the mechanisms that inhibit reduction of the calcium-uranyl-carbonato species and promote stabilization of U(V), we advance our understanding of the controls on U solubility and thus improve prediction of U transport in surface and subsurface systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structure and Negative Thermal Expansion in Zr 0.3 Sc 1.7 Mo 2.7 V 0.3 O 12

A 2 M 3 O 12 -based materials have received considerable attention owing to their wide range of negative thermal expansion (NTE) and chemical flexibility toward novel materials design. However, the structure and NTE mechanism remain challenging. In this paper, Zr 4+ and V 5+ are used as a unit to compensatorily replace Sc 3+ and Mo 6+ in Sc 2 Mo 3 O 12 to tune its thermal expansion. Its crystal structure, phase transition, NTE property, and corresponding mechanisms are studied by high-resolution synchrotron X-ray diffraction, powder X-ray diffraction, ultralow-frequency Raman spectroscopy, and density functional theory calculations. The results show that Zr 0.3 Sc 1.7 Mo 2.7 V 0.3 O 12 adopts an orthorhombic (Pbcn) structure at room temperature, with V atoms occupying the position of Mo1 atoms and Zr atoms occupying the position of Sc atoms, and transforms to monoclinic (P2 1 /a) structure at similar to ~133 K (45 K lower than that of Sc 2 Mo 3 O 12 ). It exhibits excellent NTE in a broader range. Most of the phonon modes below 350 cm -1 have negative Grüneisen parameters, of which the lowest and next-lowest frequency (38.5 and 45.8 cm -1 ) optical phonon modes arising from the translational vibrations of the Sc/Zr and Mo/V atoms in the plane of the nonlinear linkage Sc/Zr-O-Mo/V have the largest and next-largest negative Grüneisen parameters and positive total anharmonicity, and contribute most to the NTE.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis, Structure, and Photophysical Properties of Platinum Compounds with Thiophene-Derived Cyclohexyl Diimine Ligands

Platinum(II) and platinum(IV) compounds were prepared by the stereoselective and regioselective reactions of thiophene-derived cyclohexyl diimine C^N^N-ligands with [Pt 2 Me 4 (μ-SMe 2 ) 2 ]. Newly synthesized ligands were characterized by NMR spectroscopy and elemental analysis, and Pt(II)/Pt(IV) compounds were characterized by NMR spectroscopy, elemental analysis, high-resolution mass spectrometry, and single-crystal X-ray diffraction. UV–vis absorbance and photoluminescence measurements were performed on newly synthesized complexes, as well as structurally related Pt(II)/Pt(IV) compounds with benzene-derived cyclohexyl diimine ligands, in dichloromethane solution, as solids, and as 5% by weight PMMA-doped films. DFT and TD-DFT calculations were performed, and the results were compared with the observed spectroscopic properties of the newly synthesized complexes. X-ray total scattering measurements and real space pair distribution function analysis were performed on the synthesized complexes to examine the local- and intermediate-range atomic structures of the emissive solid states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved precision in As speciation analysis with HERFD-XANES at the As K -edge: the case of As speciation in mine waste

High-energy-resolution fluorescence-detected (HERFD) X-ray absorption near-edge spectroscopy (XANES) is a spectroscopic method that allows for increased spectral feature resolution, and greater selectivity to decrease complex matrix effects compared with conventional XANES. XANES is an ideal tool for speciation of elements in solid-phase environmental samples. Accurate speciation of As in mine waste materials is important for understanding the mobility and toxicity of As in near-surface environments. In this study, linear combination fitting (LCF) was performed on synthetic spectra generated from mixtures of eight measured reference compounds for both HERFD-XANES and transmission-detected XANES to evaluate the improvement in quantitative speciation with HERFD-XANES spectra. The reference compounds arsenolite (As 2 O 3 ), orpiment (As 2 S 3 ), getchellite (AsSbS 3 ), arsenopyrite (FeAsS), kaňkite (FeAsO 4 ·3.5H 2 O), scorodite (FeAsO 4 ·2H 2 O), sodium arsenate (Na 3 AsO 4 ), and realgar (As 4 S 4 ) were selected for their importance in mine waste systems. Statistical methods of principal component analysis and target transformation were employed to determine whether HERFD improves identification of the components in a dataset of mixtures of reference compounds. LCF was performed on HERFD- and total fluorescence yield (TFY)-XANES spectra collected from mine waste samples. Arsenopyrite, arsenolite, orpiment, and sodium arsenate were more accurately identified in the synthetic HERFD-XANES spectra compared with the transmission-XANES spectra. In mine waste samples containing arsenopyrite and either scorodite or kaňkite, LCF with HERFD-XANES measurements resulted in fits with smaller R -factors than concurrently collected TFY measurements. The improved accuracy of HERFD-XANES analysis may provide enhanced delineation of As phases controlling biogeochemical reactions in mine wastes, contaminated soils, and remediation systems.

58 GEOSCIENCES↗

Flight Readiness of Mochii ISS-NL Portable Spectroscopic Electron Microscope

Electron microscopes (EM’s), are workhorse tools serving diverse fields such as materials science, biological science, and engineering. Scanning EM’s (SEM’s) in particular enable high magnification study and pinpoint chemical analyses of structures down to the nanoscale by providing a powerful blend of strong optical scattering, high native resolution, large depth of focus, and energy-dispersive X-ray spectroscopy (EDS). Mochii is the world’s smallest production electron microscope, scheduled to travel to the International Space Station (ISS) this spring where it will serve as an ISS National Laboratory (ISSNL) microgravity facility on successful demonstration. We previously reported on progress preparing Mochii for space flight, in particular flight integration verifications and science application testing. These included standard integration testing such as electromagnetic interference and flight vibration, and extend to unique functional testing such as magnetic susceptibility and extreme analog environment testing under the sea. Presently, Mochii payload flight hardware has completed testing and was handed over to NASA’s ISS payload processing facility in Houston. It will make its way to the the east coast for launch currently scheduled on Space-X CRS-20 for Mission increment 62 in March 2020.

Own, C. S.↗

X-Ray Weak Broad-Line Quasars: Absorption or Intrinsic X-Ray Weakness

XMM observations of X-ray weak quasars have been performed during 2003. The data for all but the last observation are now available (there has been a delay of several months on the initial schedule, due to high background flares which contaminated the observations: as a consequence, most of them had to be rescheduled). We have reduced and analyzed these data, and obtained interesting preliminary scientific results. Out of the eight sources, 4 are confirmed to be extrimely X-ray weak, in agreement with the results of previous Chandra observations. 3 sources are confirmed to be highly variable both in flux (by factors 20-50) and in spectral properties (dramatic changes in spectral index). For both these groups of objects, an article is in preparation. Preliminary results have been presented at an international workshop on AGN surveys in December 2003, in Cozumel (Mexico). In order to further understand the nature of these X-ray weak quasars, we submitted proposals for spectroscopy at optical and infrared telescopes. We obtained time at the TNG 4 meter telescope for near-IR observations, and at the Hobby-Eberly Telescope for optical high-resolution spectroscopy. These observations will be performed in early 2004, and will complement the XMM data, in order to understand whether the X-ray weakness of these sources is an intrinsic property or is due to absorption by circumnuclear material.

Risaliti, Guido↗

Simultaneous UV and X-ray Spectroscopy of the Seyfert 1 Galaxy NGC 5548. I: Physical Conditions in the UV Absorbers

We present new UV spectra of the nucleus of the Seyfert 1 galaxy NGC 5548, which we obtained with the Space Telescope Imaging Spectrograph at high spectral resolution, in conjunction with simultaneous Chandra X-ray Observatory spectra. Taking advantage of the low UV continuum and broad emission-line fluxes, we have determined that the deepest UV absorption component covers at least a portion of the inner, high-ionization narrow-line region (NLR). We find nonunity covering factors in the cores of several kinematic components, which increase the column density measurements of N V and C IV by factors of 1.2 to 1.9 over the full-covering case; however, the revised columns have only a minor effect on the parameters derived from our photoionization models. For the first time, we have simultaneous N V and C IV columns for component 1 (at -1040 km/s), and find that this component cannot be an X-ray warm absorber, contrary to our previous claim based on nonsimultaneous observations. We find that models of the absorbers based on solar abundances severely overpredict the O VI columns previously obtained with the Far Ultraviolet Spectrograph, and present arguments that this is not likely due to variability. However, models that include either enhanced nitrogen (twice solar) or dust, with strong depletion of carbon in either case, are successful in matching all of the observed ionic columns. These models result in substantially lower ionization parameters and total column densities compared to dust-free solar-abundance models, and produce little O VII or O VIII, indicating that none of the UV absorbers are X-ray warm absorbers.

Crenshaw, D. M.↗

X-ray Weak Broad-line Qquasars: Absorption or Intrinsic X-ray Weakness

XMM observations of X-ray weak quasars have been performed during 2003 and 2004. The data for all the observations have become available in 2004 (there has been a delay of several months on the initial schedule, due to high background flares which contaminated the observations: as a consequence, most of them had to be rescheduled). We have reduced and analyzed all the data, and obtained interesting scientific results. Out of the eight sources, 4 are confirmed to be extremely X-ray weak, in agreement with the results of previous Chandra observations. 3 sources are confined to be highly variable both in flux (by factor 20-50) and in spectral properties (dramatic changes in spectral index). For both these groups of objects we are completing a publication: 1) For the X-ray weak sources, a paper is submitted with a complete analysis of the X-ray spectra both from Chandra and XMM-Newton, and a comparison with optical and near-IR photometry obtained from all-sky surveys. Possible models for the unusual spectral energy distribution of these sources are also presented. 2) For the variable sources, a paper is being finalized where the X-ray spectra obtained with XMM-Newton are compared with previous X-ray observations and with observations at other wavelengths. It is shown that these sources are high luminosity and extreme cases of the highly variable class of narrow-line Seyfert Is. In order to further understand the nature of these X-ray weak quasars, we submitted proposals for spectroscopy at optical and infrared telescopes. We obtained time at the TNG 4 meter telescope for near-IR observations and at the Hobby-Eberly Telescope for optical high-resolution spectroscopy. These observations have been performed in early 2004. They will complement the XMM data and will lead to understanding of whether the X-ray weakness of these sources is an intrinsic property or is due to absorption by circum-nuclear material. The infrared spectra of the variable sources have been already analyzed and are discussed in the paper by Memola et al. which will be soon submitted.

Mushotzky, Richard↗

Overionized plasma in the supernova remnant Sagittarius A East anchored by XRISM observations

Sagittarius A East is a supernova remnant with a unique surrounding environment, as it is located in the immediate vicinity of the supermassive black hole at the Galactic center, Sagittarius A$^{*}$. The X-ray emission of the remnant is suspected to show features of overionized plasma, which would require peculiar evolutionary paths. We report on the first observation of Sagittarius A East with the X-Ray Imaging and Spectroscopy Mission (XRISM). Equipped with a combination of a high-resolution microcalorimeter spectrometer and a large field-of-view CCD imager, we for the first time resolved the Fe xxv K-shell lines into fine structure lines and measured the forbidden-to-resonance intensity ratio to be $1.39 \pm 0.12$, which strongly suggests the presence of overionized plasma. We obtained a reliable constraint on the ionization temperature just before the transition into the overionization state, of $\gt\! 4\:$keV. The recombination timescale was constrained to be $\lt\! 8 \times 10^{11} \:$cm$^{-3}\:$s. The small velocity dispersion of $109 \pm 6\:$km$\:$s$^{-1}$ indicates a low Fe ion temperature $\lt\! 8\:$keV and a small expansion velocity $\lt\! 200\:$km$\:$s$^{-1}$. The high initial ionization temperature and small recombination timescale suggest that either rapid cooling of the plasma via adiabatic expansion from dense circumstellar material or intense photoionization by Sagittarius A$^{*}$ in the past may have triggered the overionization.

galaxy center↗

Hybrid Molecular Beam Epitaxy for Single-Crystalline Oxide Membranes with Binary Oxide Sacrificial Layers

The advancement in thin-film exfoliation for synthesizing oxide membranes has led to possibilities for creating artificially assembled heterostructures with structurally and chemically incompatible materials. The sacrificial layer method is a promising approach to exfoliate as-grown films from a compatible material system, allowing for their integration with dissimilar materials. Nonetheless, the conventional sacrificial layers often possess an intricate stoichiometry, thereby constraining their practicality and adaptability, particularly when considering techniques such as molecular beam epitaxy (MBE). This is where easy-to-grow binary alkaline-earth-metal oxides with a rock salt crystal structure are useful. These oxides, which include (Mg, Ca, Sr, Ba)O, can be used as a sacrificial layer covering a much broader range of lattice parameters compared to conventional sacrificial layers and are easily dissolvable in deionized water. In this study, we show the epitaxial growth of the single-crystalline perovskite SrTiO 3 (STO) on sacrificial layers consisting of crystalline SrO, BaO, and Ba 1–x Ca x O films, employing a hybrid MBE method. Our results highlight the rapid (≤5 min) dissolution of the sacrificial layer when immersed in deionized water, facilitating the fabrication of millimeter-sized STO membranes. Using high-resolution X-ray diffraction, atomic-force microscopy, scanning transmission electron microscopy, impedance spectroscopy, and scattering-type near-field optical microscopy (SNOM), we demonstrate single-crystalline STO membranes with bulk-like intrinsic dielectric properties. The employment of alkaline earth metal oxides as sacrificial layers is likely to simplify membrane synthesis, particularly with MBE, thus expanding the research and application possibilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New reflections on hard X-ray photon-in/photon-out spectroscopy

Analysis of the electronic structure and local coordination of an element is an important aspect in the study of the chemical and physical properties of materials. This is particularly relevant at the nanoscale where new phases of matter may emerge below a critical size. X-ray emission spectroscopy (XES) at synchrotron radiation sources and free electron lasers has enriched the field of X-ray spectroscopy. Additionally, the spectroscopic techniques derived from the combination of X-ray absorption and emission spectroscopy (XAS–XES), such as resonant inelastic X-ray scattering (RIXS) and high energy resolution fluorescence detected (HERFD) XAS, are an ideal tool for the study of nanomaterials. New installations and beamline upgrades now often include wavelength dispersive instruments for the analysis of the emitted X-rays. With the growing use of XAS–XES, scientists are learning about the possibilities and pitfalls. We discuss some experimental aspects, assess the feasibility of measuring weak fluorescence lines in dilute, radiation sensitive samples, and present new experimental approaches for studying magnetic properties of colloidal nanoparticles directly in the liquid phase.

47 OTHER INSTRUMENTATION↗

MPEX AI Digital Twins

All magnetically confined plasma fusion power plant concepts (Tokamak, Spherical Tokamak, Stellarator, Mirror, ...) must exhaust the heat and plasma from the core confinement region to the material walls. The primary channel for this exhaust is through a plasma divertor which directs plasma along open magnetic field lines to a material target. The Material Plasma Exposure eXperiment (MPEX) illustrated in Figure 1, is a high-power, steady-state linear plasma device designed to produce the plasma material interaction (PMI) conditions of the divertor of future magnetic confinement fusion power plants: energy flux 20MW/m 2 , ion fluence 1031/m 2 , pulse duration 106 sec. These goals of plasma exposure in MPEX are well beyond those achieved in magnetic fusion experimental devices. Successfully achieving these high power steady state conditions for long pulses requires operational control of the heating and particle sources and the plasma flux to the walls and target. The MPEX AI Hot Spot Controller, proposed in this project, will help achieve the operational milestones of MPEX. The MPEX device will begin commissioning at the end of FY26. A smaller proto-MPEX was operated for 14,666 plasma discharges and will resume operation in September of 2025 as proto-MPEX-lite, with reduced capability, to test a new window for the Helicon plasma source. The proto-MPEX data has undergone surrogate modeling with machine learning methods (R. Archibald, 2022 IEEE International Conference on Big Data). This proto-MPEX data will be used to begin development of the AI digital twins described in this white paper. The scientific mission of MPEX is to qualify materials of different composition for use in the high energy and plasma flux conditions of a fusion power plant. The materials exposed in MPEX will in some cases be exposed to high neutron fluxes at other ORNL facilities to measure the changes to their PMI properties. The targets exposed in MPEX will be transported under vacuum to a Surface Analysis Station (SAS). The SAS will be equipped with the following diagnostics: Focused Ion Beam (FIB) for trench milling, 100-400 angstrom resolution scanning electron microscope (SEM), surface mapping x-ray spectrometer, high resolution camera, and a future upgrade to a laser induced breakdown spectroscopy quadruple mass spectrometer (LIBS-QMS). The MPEX experiments will generate diverse pre- and post-exposure measurement data of detailed material properties down to the crystal grain level in 3D for post-exposure assessment of PMI damage (e.g. cracking, melting, erosion and redeposition of the material). Physics models for the PMI, and how the material composition and manufacturing impact its performance under high energy plasma exposure, need to be validated with MPEX data to guide the selection of new candidate materials. Our vision for the MPEX AI Digital Twins project is to supply experimental and physics model simulation data to train Artificial Intelligence (AI) models for data processing, analysis, operational control, PMI and materials simulation to maximize the scientific output of the MPEX device. Ultimately, an AI digital twin of MPEX material assessment metrics for tested and synthetic material types with simulated PMI will be trained by the AI Modeling Teams on the experimental and physics simulation data submitted to the American Science Cloud by this project. A purely empirical search for the best material is inefficient given the finite number of samples that can be tested on MPEX. In order to expand the material properties database for training the MPEX Material Assessment AI Digital Twin, and to gain physics understanding of the PMI processes, physics models of the material properties and PMI processes are required. The physics simulations provide detailed simulation data, like impact angles for plasma ions, sputtering yields, transport of the ionized sputtered target material in the plasma, and redeposition locations. This simulation data expands the measurement data for deeper physics understanding. The experimental data is essential to validate the PMI and material structure simulation models. The validated models can then be used to generate new simulation data of MPEX material assessments for synthetic material compositions that have not been exposed in MPEX. These predictive simulations, plus the whole experimental dataset, will be used to train the MPEX Material Assessment AI Digital Twin allowing a rapid generative AI search for new materials with reduced PMI damage by interpolating the domain of the training set. These new optimum materials can be simulated with the physics codes and/or tested in MPEX. The ability of AI neural networks to interpolate multi-dimensional parameter spaces and generate virtual data is exploited for a more efficient search for optimum materials. The advent of the Transformational AI Models Consortium (TAIMC) is an opportunity to engage with state of the art private and public AI developers to achieve the goals of the AI digital twins and AI accelerated physics models proposed in this project. Our partners at ORNL from the Advance Scientific Computing Research (ASCR) organization will collaborate in accelerating the integrated plasma material interaction simulation framework. This simulation framework will provide a platform for generating simulation data across a range of physical fidelities, including hybrid methods that produce multi-fidelity results. This data will be leveraged for AI model development, both for generation of surrogates and the automation of simulation campaigns. A part of the research below will include collaborative efforts with the TAIMC to (i) adapt data storage approaches to ensure AI-readiness, (ii) provide a protypical exemplar to inform and exercise constructed workflows, and (iii) generate and share data, using the TAIMC unified AI data standard, for foundational models that will be trained from multiple sources across the DOE complex. We will also collaborate with the TAIMC, as well as the planned AI modeling teams, to develop approaches for reducing the cost of data generation. These include tailored multi-fidelity approaches as well as fine-tuning strategies to augment general, large-scale foundational models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Resolution Transmission Electron Microscopy Study of a Powder River Basin Coal-Derived Fly Ash

Examination of a fly ash derived from the combustion of a low-S, subbituminous Powder River Basin coal by Scanning Electron Microscopy (SEM) and High-resolution Transmission Electron Microscopy (HRTEM), both supplemented by Energy-dispersive X-ray spectroscopy (EDS), showed that the fly ashes were dominated by amorphous phases, Ca-rich plagioclase feldspars, Mg-rich phases, complex Ca-Mg-Al-Si-Ti-Fe grains, and trace amounts of REE-rich particles. Many of the particles were rimmed by a Ca-S, possibly a sulfate. HRTEM-EDS examination of a REE-rich particle proved it to be a mix of light- and heavy-rare earth minerals mixed with amorphous phases.

58 GEOSCIENCES↗

Bragg crystal spectroscopy on the OSO 8 satellite

Results are reported for high-resolution OSO 8 Bragg-crystal spectroscopy of a variety of cosmic X-ray sources in the energy range from 2 to 10 keV. A continuous spectrum of Sco X-1 is examined, and results of a search for narrow line emission due to iron near 6.7 keV are presented for 32 galactic X-ray sources, including Sco X-1, Cyg X-3, and Cen X-3. It is noted that the strongest evidence for iron line emission has been obtained for Cyg X-3 and that evidence for an iron line feature has also been found in the spectrum of Cen X-3.

Long, K. S.↗

Physical conditions, dynamics and mass distribution in the center of the galaxy

Investigations of the central 10 pc of the Galaxy, and conclusions on energetics, dynamics, and mass distribution derived from X and gamma ray measurements and from infrared and microwave studies, especially from spectroscopy, high resolution imaging, and interferometry are reviewed. Evidence for and against a massive black hole is analyzed.

Genzel, R.↗

Latest Progress on the Gamma-Ray Imager/Polarimeter for Solar Flares (GRIPS)

We present the latest progress on building the balloon-borne Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS) instrument, including testing and calibration of the detectors and development of the imaging and aspect systems. A continental-US test flight is slated for fall 2012. GRIPS will provide a near-optimal combination of high-resolution imaging, spectroscopy, and polarimetry of solar-flare gamma-ray/hard X-ray emissions from approx.20. keV to > approx.10 MeV. The spectrometer/polarimeter consists of sixteen 3D position-sensitive germanium detectors (3D-GeDs), where each energy deposition is individually recorded with an energy resolution of a few keV FWHM and a spatial resolution to within <0.1 cu mm. Imaging is accomplished by a single multi-pitch rotating modulator (MPRM), a 2.5-cm thick tungsten-alloy grid with pitches that range quasi-continuously from 1 to 13 mm. With the MPRM situated 8 meters from the spectrometer, this instrument will provide excellent image quality and unparalleled angular resolution at gamma-ray energies (12.5 arcsec FWHM), sufficient to separate the 2.2 MeV footpoint sources for almost all flares. Polarimetry is accomplished by analyzing the anisotropy of reconstructed Compton scattering in the 3D-GeDs (i.e. as an active scatterer), with an estimated minimum detectable polarization of a few percent at 150-650 keV in an X-class flare. GRIPS will address questions relevant to particle acceleration and energy release that ha-.e been raised by recent solar flare observations, such as: What causes the spatial separation between energetic electron producing hard X-rays and energetic ions producing gamma-ray lines? How anisotropic are the accelerated electrons, and why do relativistic electron dominate in the corona? How does the composition of accelerated and ambient material vary with space and time, and why?

Shih, Albert Y.↗

The Gamma-Ray Imager/Polarimeter for Solar Flares (GRIPS)

The balloon-borne Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS) instrument will provide a near-optimal combination of high-resolution imaging, spectroscopy, and polarimetry of solar-flare gamma-ray/hard X-ray emissions from approximately 20 keV to greater than approximately 10 MeV. GRIPS will address questions raised by recent solar flare observations regarding particle acceleration and energy release, such as: What causes the spatial separation between energetic electrons producing hard X-rays and energetic ions producing gamma-ray lines? How anisotropic are the relativistic electrons, and why can they dominate in the corona? How do the compositions of accelerated and ambient material vary with space and time, and why? The spectrometer/polarimeter consists of sixteen 3D position-sensitive germanium detectors (3D-GeDs), where each energy deposition is individually recorded with an energy resolution of a few keV FWHM and a spatial resolution of less than 0.1 cubic millimeter. Imaging is accomplished by a single multi-pitch rotating modulator (MPRM), a 2.5-centimeter thick tungsten alloy slit/slat grid with pitches that range quasi-continuously from 1 to 13 millimeters. The MPRM is situated 8 meters from the spectrometer to provide excellent image quality and unparalleled angular resolution at gamma-ray energies (12.5 arcsec FWHM), sufficient to separate 2.2 MeV footpoint sources for almost all flares. Polarimetry is accomplished by analyzing the anisotropy of reconstructed Compton scattering in the 3D-GeDs (i.e., as an active scatterer), with an estimated minimum detectable polarization of a few percent at 150-650 keV in an X-class flare. GRIPS is scheduled for a continental-US engineering test flight in fall 2013, followed by long or ultra-long duration balloon flights in Antarctica.

Shih, Albert Y.↗

CubeX: A Compact X-Ray Telescope Enables Both X-Ray Fluorescence Imaging Spectroscopy and Pulsar Timing Based Navigation

This paper describes the miniaturized X-ray telescope payload, CubeX, in the context of a lunar mission. The first part describes the payload in detail, the second part summarizes a small satellite mission concept that utilizes its compact form factor and performance. This instrument can be used for both X-ray fluorescence (XRF) imaging spectroscopy and X-ray pulsar timing-based navigation (XNAV). It combines high angular resolution (<1 arcminutes) Miniature Wolter-I X-ray optics (MiXO) with a common focal plane consisting of high spectral resolution (<150 eV at 1 keV) CMOS X-ray sensors and a high timing resolution (< 1 μsec) SDD X-ray sensor. This novel combination of the instruments enables both XRF measurements and XNAV operations without moving parts, in a small form factor (~1×1×6U, <6 kg). In this paper we illustrate one potential application for a lunar mission concept: The elemental composition of the Moon holds keys to understanding the origin and evolution of both the Moon and the Earth. X-ray fluorescence (XRF), induced either by solar X-ray flux or energetic ions, carries decisive signatures of surface elemental composition. In between XRF observations, CubeX also leverages the technology of high resolution X-ray imaging and time series measurements to conduct XNAV operations and evaluate their performance.

Lunar Science↗