Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Influence of building heat distribution temperatures on the energy performance and sizing of 5th generation district heating and cooling networks

This paper investigates the energy performance and sizing criteria of 5th generation district heating and cooling (5GDHC) networks as a function of the heat distribution temperature in the building systems connected to the district network. An energy simulation model of a 5GDHC network was developed in Modelica for a case study located in Denmark. Calculations were carried out for four different building heating systems. Simulation results show that reducing the heat distribution temperatures from 70 °C to 23 °C leads to around 40% annual electric energy savings (from 10.4 kWh/m 2 to 6.2 kWh/m 2 ) for the operation of the heat pumps. Heat distribution temperatures of 23 °C cause higher water mass flow rates through the network, leading to annual electric energy consumption for the circulation pumps that are almost doubled (from 0.16 kWh/m 2 to 0.3 kWh/m 2 ) compared to the reference case at 70 °C. Furthermore, the paper discusses how the results obtained from the Danish case study can be generalized and applied to other cases using a simplified mathematical approach. In conclusion, it is found that about 1.5% of electric energy savings can be achieved for each temperature degree reduction in the heat distribution system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cross-Beam Energy Transfer Saturation by Ion Heating

Cross-beam energy transfer (CBET) saturation by ion heating was measured in a gas-jet plasma characterized using Thomson scattering. Here, a wavelength-tunable ultraviolet (UV) probe laser beam was interacted with four intense UV pump beams to drive large-amplitude ion-acoustic waves. For the highest-intensity interactions, the power transferred to the probe laser dropped, demonstrating ion-acoustic wave saturation. Over this time, the ion temperature was measured to increase by a factor of 7 during the 500-ps interaction. Particle-in-cell simulations show ion trapping and a subsequent ion heating consistent with measurements. Linear kinetic CBET models were found to agree well with the observed energy transfer when the measured plasma conditions were used.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An HPC-Based Hydrothermal Finite Element Simulator for Modeling Underground Response to Community-Scale Geothermal Energy Production

Geothermal heat, as renewable energy, shows great advantage with respect to its environmental impact due to its significantly lower CO2 emissions than conventional fossil fuel. Open and closed-loop geothermal heat pumps, which utilize shallow geothermal systems, are an efficient technology for cooling and heating buildings, especially in urban areas. Integrated use of geothermal energy technologies for district heating, cooling, and thermal energy storage can be applied to optimize the subsurface for communities to provide them with multiple sustainable energy and community resilience benefits. The utilization of the subsurface resources may lead to a variation in the underground environment, which might further impact local environmental conditions. However, very few simulators can handle such a highly complex set of coupled computations on a regional or city scale. We have developed high-performance computing (HPC) based hydrothermal finite element (FE) simulator that can simulate the subsurface and its hydrothermal conditions at a scale of tens of km. The HPC simulator enables us to investigate the subsurface thermal and hydrologic response to the built underground environment (such as basements and subways) at the community scale. In this study, a coupled hydrothermal simulator is developed based on the open-source finite element library deal.II. The HPC simulator was validated by comparing the results of a benchmark case study against COMSOL Multiphysics, in which Aquifer Thermal Energy Storage (ATES) is modeled and a process of heat injection into ATES is simulated. The use of an energy pile system at the Treasure Island redevelopment site (San Francisco, CA, USA) was selected as a case study to demonstrate the HPC capability of the developed simulator. The simulator is capable of modeling multiple city-scale geothermal scenarios in a reasonable amount of time.

Sun, Xiang↗

A coupled ground heat flux–surface energy balance model of evaporation using thermal remote sensing observations

Abstract. One of the major undetermined problems in evaporation (ET) retrieval using thermal infrared remote sensing is the lack of a physically based ground heat flux (G) model and its integration within the surface energy balance (SEB) equation. Here, we present a novel approach based on coupling a thermal inertia (TI)-based mechanistic G model with an analytical surface energy balance model, Surface Temperature Initiated Closure (STIC, version STIC1.2). The coupled model is named STIC-TI. The model is driven by noon–night (13:30 and 01:30 local time) land surface temperature, surface albedo, and a vegetation index from MODIS Aqua in conjunction with a clear-sky net radiation sub-model and ancillary meteorological information. SEB flux estimates from STIC-TI were evaluated with respect to the in situ fluxes from eddy covariance measurements in diverse ecosystems of contrasting aridity in both the Northern Hemisphere and Southern Hemisphere. Sensitivity analysis revealed substantial sensitivity of STIC-TI-derived fluxes due to the land surface temperature uncertainty. An evaluation of noontime G (Gi) estimates showed 12 %–21 % error across six flux tower sites, and a comparison between STIC-TI versus empirical G models also revealed the substantially better performance of the former. While the instantaneous noontime net radiation (RNi) and latent heat flux (LEi) were overestimated (15 % and 25 %), sensible heat flux (Hi) was underestimated (22 %). Overestimation (underestimation) of LEi (Hi) was associated with the overestimation of net available energy (RNi−Gi) and use of unclosed surface energy balance flux measurements in LEi (Hi) validation. The mean percent deviations in Gi and Hi estimates were found to be strongly correlated with satellite day–night view angle difference in parabolic and linear pattern, and a relatively weak correlation was found between day–night view angle difference versus LEi deviation. Findings from this parameter-sparse coupled G–ET model can make a valuable contribution to mapping and monitoring the spatiotemporal variability of ecosystem water stress and evaporation using noon–night thermal infrared observations from future Earth observation satellite missions such as TRISHNA, LSTM, and SBG.

Bhattacharya, Bimal K.↗

A Propane Hydronic Heat Pump with Energy Storage

Propane is an environment-friendly refrigerant, having a 20-year GWP (global warming potential) of 0.072 and a 100-year GWP of 0.02, as compared to R-410A having a GWP > 2000. It has superior thermodynamic cycle performance and heat transfer characteristics. However, propane is classified as a A3 refrigerant, which is highly flammable, and not allowed to be used indoor if the system charge is higher than 150 grams. It is a challenge to use propane in residential applications requiring a rated capacity larger than 10 k Watts. A hydronic heat pump, i.e., containing propane in an outdoor unit and distributing the cooling and heating capacity through a hydronic coil to the indoor space addresses the flammability issue, while maintaining a high efficiency. We developed a hydronic heat pump with propane, it uses a two-stage compressor, a brazed plate indoor heat exchanger, and a microchannel outdoor heat exchanger. It achieves a rated cooling capacity larger than 10 k Watts, and a cooling SEER (cooling seasonal energy efficiency rating) > 16.0 (cooling seasonal COP > 4.7) and a heating HSPF (heating seasonal performance factor) > 9.5 (heating seasonal COP > 2.78), while requiring a system charge < 1200 grams. Additionally, the hydronic heat pump was evaluated in a laboratory water heating loop to heat a 50-gallon water tank in a full condensing mode. Experiments of heating the tank water from 58F(14.4°C) to 150F(65.6°C) were conducted under ambient temperatures from 17F(-8.3°C) to 75F(23.9°C), at the compressor high and low stages.

Shen, Bo↗

Design and evaluation of a dilute flow particle-to-air heat exchanger for energy storage applications

The use of inert and redox-active particles for high-temperature energy storage requires the development of components that can efficiently transfer energy to high-pressure working fluids like supercritical carbon dioxide (sCO 2 ). Dilute flow reactors can enable high working fluid outlet temperatures and minimal parasitic losses compared to moving packed bed and fluidized bed reactors. This research uses both computational and experimental methods to explore the design trade-offs and practical challenges of a novel component for transferring energy from dilute flows of hot, reduced metal oxide (MO x ) particles to sCO 2 in tubes. A discretized thermal resistance network model, which accounts for particle hydrodynamics, multi-mode heat transfer, and reaction equilibrium, guides the design of a prototype device. This device is experimentally tested with a surrogate heat transfer fluids and inert particle temperatures up to 400°C and a heat duty exceeding 1 kW. The data are used to validate the thermal hydraulic sub-models, allowing for the simulation of reacting particle scenarios. Under nominal design conditions, the flow rate of reactive particles is predicted to be 30% lower than that of inert particles for the same energy recovered, with over 70% of the stored particle energy transferred to the sCO 2 . Furthermore, these findings can inform the design of more efficient energy recovery reactors for particle-based systems and can be integrated into system-level concentrated solar power models with thermal storage to optimize operating conditions.

14 SOLAR ENERGY↗

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

Ultra-High Operation Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR) enabled by additive manufacturing: Test Facility & Performance Evaluations

Solar Heat for Industrial Processes (SHIP) cavity receivers are capable of generating electricity or industrial process heat by absorbing thermal energy from solar radiation, focused on a small area. The concentration of solar radiation on the small area of the receiver enables the achievement of high temperatures (ranging from 400°C to 1,100°C) of a working fluid, thus making the SHIP technology thermodynamically comparable with conventional power plants. A volumetric receiver consists of a porous structure-generally made of silicon carbide or metal, which absorbs solar radiation and converts it into heat energy. Heat energy from the porous materials is then transferred to the fluid following through them. A volumetric receiver acts as a convective heat exchanger, transferring heat to the fluid through convection. Open-loop volumetric receivers work with air at atmospheric pressure and are suitable for single-cycle or multi-cycle energy plants. A Model Based Systems Engineering (MBSE) approach was used to develop a test bed at Sandia national Laboratories (SNL) capable of demonstrating an open-loop volumetric air receiver developed by General Electric Aerospace (GE Aerospace). This paper presents the development of the various MBSE methods, test bed, and testing operations for the GE air receiver, which was experimentally demonstrated to achieve 1,350°C for over 3 hours of operation and an approximate 70% receiver efficiency. By being able to achieve such high temperatures >1,000°C, this work provides the potential to support many SHIP industrial use cases.

14 SOLAR ENERGY↗

Solar energy for process heat: Design/cost studies of four industrial retrofit applications

Five specific California plants with potentially attractive solar applications were identified in a process heat survey. These five plants were visited, process requirements evaluated, and conceptual solar system designs were generated. Four DOE (ERDA) sponsored solar energy system demonstration projects were also reviewed and compared to the design/cost cases included in this report. In four of the five cases investigated, retrofit installations providing significant amounts of thermal energy were found to be feasible. The fifth was rejected because of the condition of the building involved, but the process (soap making) appears to be an attractive potential solar application. Costs, however, tend to be high. Several potential areas for cost reduction were identified including larger collector modules and higher duty cycles.

French, R. L.↗

Consumer Guide to Geothermal Heat Pumps

Learn how geothermal heat pumps can provide energy efficient heating and cooling using the earth's natural heat. This fact sheet from Energy Saver includes information on how geothermal heat pumps work, how they are different from air-source heat pumps, the types of geothermal heat pumps, and how they can help you save energy and money.

geothermal heat pump, heating, cooling, Energy Sav↗

Development and evaluation of a multi-functional heat pump with embedded thermal storage

We developed and tested a novel multi-functional packaged vertical heat pump designed for multi-family buildings, capable of providing space cooling, space heating, water heating, and energy storage integration. The system employs a 3-speed scroll compressor and supports energy-efficient cooling and heating across different ambient conditions, while utilizing both indoor and outdoor air sources for water heating. Key performance metrics include an integrated energy efficiency ratio of 18.0 for cooling, a heating seasonal performance factor of 10.0, and a coefficient of performance (COP) of 2.1 for heating in cold climates down to −15 ˚C. Additionally, the system delivers an annual water heating COP greater than 4.0, with outstanding performance in combined space cooling and water heating modes, achieving a total COP of 8.8 by recovering condenser waste heat. The heat pump also demonstrated thermal energy storage capabilities, integrating with phase change material systems to store heating and cooling energy. Furthermore, this versatile system offers a promising solution for improving energy efficiency and sustainability in multi-family buildings, providing high-performance heating, cooling, and water heating across a range of climates.

COP↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiative Heating Rates Computed With Clouds Derived From Satellite‐Based Passive and Active Sensors and their Effects on Generation of Available Potential Energy

Radiative heating rates computed with cloud properties derived from passive and active sensors are investigated. Zonal monthly radiative heating rate anomalies computed using both active and passive sensors show that larger variability in longwave cooling exists near the tropical tropopause and near the top of the boundary layer between ~50°N to ~50°S. Aerosol variability contributes to increases in shortwave heating rate variability. When zonal monthly mean cloud effects on the radiative heating rate computed with both active and passive sensors and those computed with passive sensor only are compared, the latter shows cooling and heating peaks corresponding to cloud top and base height ranges used for separating cloud types. The difference of these two sets of cloud radiative effect on heating rates in the middle to upper troposphere is larger than the radiative heating rate uncertainty estimated based on the difference of two active sensor radiative heating rate profile data products. In addition, radiative heating rate contribution to generation of eddy available potential energy is also investigated. Although radiation contribution to generation of eddy available potential energy averaged over a year and the entire globe is small, radiation increases the eddy available potential energy in the northern hemisphere during summer. Two key elements that longwave radiation contribute to the generation of eddy potential energy are (1) longitudinal temperature gradient in the atmosphere associated with land and ocean surface temperatures contrasts and absorption of longwave radiation emitted by the surface and (2) cooling near the cloud top of stratocumulus clouds.

Kato, Seiji↗

Heat Loss Characteristics and Energy Use of Piperazine with the Advanced Stripper (PZAS) at the UT-SRP Pilot Plant

Heat duty and heat loss were measured at the pilot plant at UT Austin. Heat loss was measured with energy balances using water. Heat loss was studied using surface temperature measurements over 68 different locations at the pilot plant. Surface temperature measurements indicated that bare metal surfaces were the primary source of heat loss from the pilot plant. Heat loss from bare metal surfaces was at least 50% controlled by natural convection and in many cases was as high as 75% natural convection controlled. Measured heat loss at the pilot plant was 20100 BTU/hr and overall heat loss did not show any dependence on the heat rate of the plant. Compared to PZAS™ at the National Carbon Capture Center, heat loss relative to heat rate was higher at 38%. The relative heat loss at the pilot plants was found to decrease by 20% per MW of added capacity. Measured net heat duty was found to be dependent on measured lean loading and cold rich bypass flow rate. Measured net heat duty was between 2.2 and 2.4 GJ/tonne at an optimum lean loading of 0.2–0.21 mol/mol. Data reconciliation by Aspen Plus® Data Fit™ underpredicted CO2 flow rate by 20% due to an overprediction of lean loading by 19%, indicating a necessary change in thermodynamic parameters in the model. This resulted in an over prediction of heat duty by 33% on average.

Amine scrubbing, stripper, energy requirement, hea↗

An approach for fast and accurate simulation of phase change material based thermal energy storage in buildings

Latent heat thermal energy storage (LHTES) has significant potential for mitigating peak electricity demand and enabling load shifting in buildings. Phase Change Material embedded heat exchangers (PCM-HX) can significantly improve energy demand management due to high storage capacity. However, PCM-HX evaluation typically depends on computationally expensive fully transient simulations, posing significant challenges for scalable system- and building-level energy assessments across different climates and system architectures. This paper presents a generalized, accurate, and computationally efficient methodology for simulating building energy systems integrated with LHTES. The PCM-HX transient performance is represented by performance maps generated using a Generalized Resistance-Capacitance Model (GRCM) that enables accurate predictions of arbitrary PCM-HXs at low computational cost. The feasibility of the proposed approach was verified using a case study considering a dual-mode heat pump-thermal energy storage (HP-TES) system simulated in Modelica with Spawn of EnergyPlus™ for a DOE prototype small office building in two locations: Tampa, FL, and International Falls, MN. The PCM-HX performance maps provided accurate predictions of PCM-HX transient behavior, with mean absolute percentage deviations within 2–4% compared to GRCM while also achieving at least 1800× reduction in computational time. Moreover, the HP-TES system achieved energy savings of up to 17.4% in Tampa, FL, and 62.2% in International Falls, MN, demonstrating the broader applicability of the proposed methodology across different climate zones. This work highlights the importance of robust PCM-HX models in enabling accurate and computationally efficient building-level simulations and enabling future research opportunities for investigating optimized HP-TES designs and advanced control strategies for grid-interactive buildings.

Modelica↗

Enhancing building resilience in cold climates: Integrating heat pump technologies with renewable energy

As electrification advances and Cold Climate Heat Pump technology progresses, ensuring grid stability becomes increasingly critical for effective heating in cold climates. However, natural disasters, especially during winter, pose significant threats to grid stability, impacting the reliability of air-source heat pumps. Despite these challenges, the integration of renewable energy sources and storage solutions in heating systems has not been extensively studied within the context of resilience. Here, this paper delves into the literature on renewable-powered heat pumps to assess their potential in enhancing building resilience in U.S. cold climate zones, which are particularly susceptible to extreme weather and grid disruptions. By leveraging renewable sources—solar, geothermal, and water—in conjunction with heat pump technology and supported by thermal or battery storage, this approach aims to provide a dependable solution for maintaining indoor heating during grid failures. Our analysis begins with a review of various renewable energy sources suitable for heat pumps, followed by an exploration of their application in cold climate regions across the U.S., and discussions on potential integration strategies with heat pump systems. This study highlights the advantages and suitability of solar irradiance and geothermal resources, emphasizing the importance of tailored, site-specific assessments to maximize energy efficiency and resilience. Additionally, it outlines the economic and environmental considerations necessary for implementing such systems and identifies potential challenges and areas for future research to facilitate the broader integration of renewable energy in heating solutions for enhanced resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗