Integration of Large-Scale Electrical Imaging into Geological Framework Development and Refinement

Geologic framework models (GFMs) are critical to the construction of reliable simulation models of groundwater flow and contaminant transport. To support GFM development, direct information (e.g., core samples, fluid samples, hydraulic testing) tends to be sparse and separated by large distances relative to the spatial scales of aquifer heterogeneity. There are additional challenges associated with highly contaminated legacy waste sites, where drilling is particularly costly, and invasive sampling requires specialized handling and disposal of hazardous materials. At these sites in particular, non-invasive geophysical imaging can play an important role in filling spatial gaps between boreholes and reducing characterization costs by optimizing and minimizing the number of necessary boreholes. Here this paper presents a case study demonstrating the use of large-scale (> 30 km 2 ) electrical mapping to identify hydrostratigraphy and potential paleochannels at the Hanford Site, located in Washington State, USA. In two field campaigns, over 36 line-kilometers of electrical resistivity tomography (ERT) data were collected along 14 transects. ERT surveys were sited and performed to image critical aspects (e.g., paleochannels, stratigraphic contacts) of the subsurface, demonstrating a general workflow for integrating ERT with GFM development. Inconsistencies between the GFM and ERT were catalogued to provide a basis for future site characterization using complementary geophysical methods and (or) direct sampling.

58 GEOSCIENCES↗

PFLOTRAN modeling data and scripts associated with “Refining the Hydrogeologic Framework of a Large River Corridor Model Using Waterborne Transient Electromagnetics”

NOTE: The manuscript associated with this data package is currently in review. The data may be revised based on reviewer feedback. Upon manuscript acceptance, this data package will be updated with the final dataset and additional metadata. This data package is associated with the publication “Refining the Hydrogeologic Framework of a Large River Corridor Model Using Waterborne Transient Electromagnetics” submitted to Water Resources Research (Terry et al. 2025). The data package contains the groundwater modeling dataset from PFLOTRAN software. It includes the python script for mesh generation, boundary condition setting, PFLOTRAN input deck formation and postprocessing. It couples groundwater flow and species transport for Hanford Reach river corridor and pipelines the model generation and processing. This model can be used to easily generate the model and analysis for Hanford site. It can also be adjusted to other hydrologic area with ease. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. The data package consists of 6 folders: (1) “data” contains all necessary data as input and intermediate data for processing; (2) “mesh” contains all mesh related files to generate mesh in Hanford Reach river corridor; (3) “model_run” contains the generated script for PFLOTRAN modeling; (4) “notebooks” contains all the Python script to generate the model; (5) “output” contains all the output from the computation; (6) “postprocessing” contains the Python script to generate scientific figure for manuscript. All files are .csv (comma-separated values), .h5 (HDF5 format), .in (input files), .ipynb (Jupyter notebooks), .p (Python pickle), .png (images), .PNG (images), .py (Python scripts), .pyc (Python bytecode), .r (R scripts), .sh (shell scripts), .txt (text files), .vtu (3D mesh/visualization format), .xz (compressed archive), or .zip (compressed archive).

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Material Balance Approaches for Hanford Direct-Feed Low Activity Waste Processing - 20022

The Hanford Site has accumulated millions of gallons of tank waste from reprocessing spent fuel to recover plutonium, uranium, cesium, and strontium. The supernatant from the accumulated tank waste will be treated using a Direct Feed Low-Activity Waste approach. The supernatant will be treated to remove solids and cesium in the Tank-Side Cesium Removal process in the Hanford tank farm, then vitrified in a semi-batch process in the Hanford Waste Treatment and Immobilization Plant (WTP). Currently, each batch of feed is sampled at three locations prior to being fed to the melter: the feed qualification tank in the Hanford tank farm as well as the concentrate receipt vessel (CRV) and melter feed preparation vessel (MFPV) in the WTP. The feed qualification sample is taken from a large batch of accumulated feed, only two to three samples are expected each year. Approximately 275 samples from the CRVs and 1100 samples from the MFPV are expected each year. An evaluation was performed to determine if a material balance based on the feed qualification sample could replace most of the sampling in the CRVs and MFPVs. The evaluation consisted of three elements: (1) determination of the practicality of using a material balance to estimate the stream composition of the CRV and MFPV contents, (2) evaluation of whether the material balance could be automated using the existing process control system, and (3) determination of the uncertainty in glass composition using the material balance approach. It is assumed that periodic sampling at the CRV and MFPV would be performed periodically to re-baseline the material balance, evaluations are in progress to determine the frequency of this periodic sampling. Process sample locations downstream of the melter were reviewed as well, but the partitioning of semi-volatile species in the melter was determined to preclude extending the material balance approach past the melter. It was determined that replacement of the CRV sample location was feasible and did not increase process uncertainty or significantly impact waste loading. Replacement of the MFPV sample was also determined to be feasible, but that measurement of the glass former chemical addition may be needed prior to addition of these chemicals to the MFPV. This measurement could be performed by an in situ laser-induced breakdown spectroscopy (LIBS) system. Limited tests were performed to evaluate LIBS for direct measurements of the low-activity waste melter feed. The use of a material balance would eliminate over 1200 samples each year if only 10% of the CRV and MFPV batches are sampled and could likely allow the WTP laboratory to operate on days only versus 24/7 operation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Computationally Aided Design of a Small-Scale Waste-Glass Melter - 20452

To provide mission support to the WTP for the vitrification of legacy nuclear tank waste at the Hanford site, a reduced-scale vitrification pilot system is being designed to process simulated and actual radioactive tank wastes. The waste stored in underground tanks will be separated into HLW and LAW fractions, where the majority is LAW by mass (approximately 90%) and HLW by activity (greater than 95%). The first tank waste to be processed at the WTP will be LAW. Because Hanford tank waste and the resultant melter feed compositions are known to vary widely, pilot-scale operations are essential to identify potential problems, provide needed data, confirm assumptions, and determine impacts to full-scale melters and off-gas systems from these different feeds. In addition, the reduced-scale melter system must be capable of quickly providing results to operations without the typically high cost of full-scale radioactive operations and to provide an engineering platform in close proximity to local operations staff. The objectives of this computational modeling effort are to produce process conditions like those encountered in the WTP LAW melters and to minimize the volume of radioactive waste necessary for the evaluations. To this end, melter design features are being explored to increase production without significantly increasing surface area or melter-glass volumes or compromising data quality. In support of these objectives, a set of computational fluid dynamic models was developed to provide insight into the flow patterns within these small melters and evaluate design features to increase production without significantly increasing glass inventory. Computed velocities were evaluated at the interface between the cold cap and the molten-glass pool and within the bulk-glass pool. Since melt rate correlates with the velocity underneath the cold cap, this information can be used to select design features that produce the highest gains. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Geophysical Methods for Stratigraphic Identification

The goal of this work is to identify geophysical methods that can be used to delineate (in 3D) a large-scale paleochannel that has been inferred to exist between the 200 West and 200 East Areas of the Hanford Site’s Central Plateau . This paleochannel is of particular importance because it will significantly impact flow and contaminant transport from 200 West to 200 East. Its high permeability can both accelerate contaminant transport and lower contaminant concentrations through spreading. Information about the spatial extent and structure of such features is needed to inform subsurface flow and contaminant transport models that support remedy decisions at Hanford.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling Interfaces to Support Low-Level Waste Disposal System Performance Assessments - 20366

In low-level waste (LLW) disposal sites, interfaces between cementitious materials, used as waste forms and/or engineered barriers, and the surrounding soil or backfill material are often encountered. Reactions across these interfaces may lead to chemical and structural alteration of the cementitious and backfill materials that may ultimately affect long-term performance. For example, the ingress of carbon dioxide from soil gas into a waste tank concrete shell at the Hanford Site or Savannah River Site (SRS) or a low-level waste disposal vault at SRS leads to carbonation of cement hydration products (e.g. portlandite, calcium-silicate hydrate or C-S-H, and ettringite). The result of carbonation is a decrease in pH in the cement paste portion of the tank wall or vault concrete structure that could ultimately lead to de-passivation of the embedded structural steel and, eventually, to cracking. Cracking can lead to increased ingress of water into the structure, corresponding increased release of constituents of concern, and to subsequent increased transport of these constituents to the surrounding environment. The mobility of trace constituents (e.g., radionuclides of concern) in waste forms may increase in response to changes in pH, pore structure, and mineralogical gradients. Depletion of portlandite results in subsequent decalcification of C-S-H that leads to changes in the cement strength and may lead to structural failure. At the boundary between waste forms and concrete vaults, the migration of sulfate ions from the salt waste form (e.g., the saltstone waste form used for LLW disposal at the Savannah River Site in Saltstone Disposal Units, or SDUs) into the barrier or vault concrete has been predicted to result in expansive mineral phase formation (or 'sulfate attack'). Expansive mineral formation could result in cracking and potential loss of structural integrity in the vault concrete. In the performance assessment (PA) for the SRS SDUs, prediction of both the carbonation and sulfate attack fronts are critical to assessing the long-term performance of these LLW disposal vaults. A general purpose geochemical reactive transport model has been developed in LeachXS/ORCHESTRA to evaluate typical interfaces for LLW disposal environments, including SDUs at SRS. The model may be used to predict the long-term performance of interfaces between cementitious materials and saltstone or backfill materials with respect to primary phases by considering mass transport, cement chemistry, geochemical speciation, and multi-ionic diffusion over interfaces between different materials. The present study compares the performance and interactions between vault concrete and saltstone waste form for a representative SDU scenario. The materials were characterized using pH-dependence leaching test (EPA 1313) and semi-dynamic transport tests (EPA 1315) with test results used to parameterize the interface model. The development of a credible inter model provides an important basis for supporting future PAs where carbonation and sulfate attack are important aging and degradation mechanisms. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Carbon Tetrachloride Degradation Results for 200-ZP-1 Operable Unit

Carbon tetrachloride (CT) contamination in the 200-ZP-1 Operable Unit (OU) at the Hanford Site originated from large-volume discharges to the subsurface during plutonium production operations between 1955 and 1973. Contamination migrated through more than 70 meters of unsaturated sediment to reach the underlying unconfined aquifer, where it persists as a large and complex groundwater plume. The 200-ZP-1 OU Record of Decision (ROD) requires that groundwater CT concentrations be reduced to 3.4 µg/L within 125 years. Current groundwater modeling projections estimate that the existing pump-and-treat, even when combined with monitored natural attenuation (specifically hydrolysis), will not achieve this target within the designated timeframe. A fundamental contributor to this shortfall is the extremely slow rate of CT hydrolysis under Hanford aquifer conditions, which has been estimated to have a half-life of 630 years. If faster-acting biotic and abiotic degradation processes are operating within the aquifer, their contribution to CT mass reduction could have a meaningful impact. However, site-specific measurements of these processes and their rates have not previously been performed. This report documents the results of a two-phase laboratory investigation designed to characterize and quantify the capacity of site-specific 200-ZP-1 OU sediments and groundwater to support natural attenuation of CT through biotic and abiotic pathways. In this context, degradation capacity is defined as the intrinsic potential of the subsurface matrix to transform CT under optimized, controlled conditions. System capacity is evaluated in two ways: (1) as rate-limited capacity, which establishes the maximum kinetic velocity of CT transformation and is measured using half-lives and first order rate constants; and (2) as mass limited capacity, which defines the total contaminant mass the batch experimental system can degrade before reactants are exhausted, representing the maximum amount of contaminant the microbial community and reactive mineral phases can transform under the experimental conditions.

abiotic degradation↗

LDR Inorganic Spiked Simulants in Pozzolan-Substituted Cast Stone for Hanford Pretreated Low-Activity Tank Waste

Pretreated Low Activity Waste (PTW/LAW) at the Hanford Site, is currently projected for disposition through a cementitious waste form. The current standard formulation, Cast Stone, uses Class F fly ash, blast furnace slag, and Portland cement. However, the future availability of Class F fly ash is uncertain, as many coal-fired power plants—the source of this byproduct—are being decommissioned or converted to natural gas. This issue has prompted research into identifying and evaluating suitable alternative materials to replace fly ash in the cementitious waste forms used by the Department of Energy (DOE). The Savannah River National Laboratory (SRNL) successfully identified four natural pozzolans for the replacement of Class F fly ash in the current Savannah River Site (SRS) low-level waste (LLW) form, Saltstone.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurement of Iodine, Iodide, and Iodate in Hanford Tank Waste: Technology Transfer from PNNL to Hanford 222-S Laboratory

This report summarizes the measurement of the inorganic chemical forms of iodine in Hanford tank waste. The Hanford tank wastes have roughly a part per million iodine. Part of the iodine is the long-lived beta emitter 129I, and the rest is stable 127I. Because tank waste iodine is radioactive and radiotoxic, its chemical form must be known so that its behavior in the vitrification process can be reliably known and anticipated in various waste streams (glass, secondary liquid and solid waste, and offgas emissions) at Hanford. Iodine in tank wastes exists in the inorganic chemical forms iodide and iodate (and possibly also periodate) and also as organic forms such as alkyl iodides. The measurement of organic iodides is very different from the measurement of inorganic forms and is outside the scope of this report. The inorganic chemical forms are chemically separated, in sequence, from the raw tank waste using solvent extractions and several redox reactions, then measured by ICP-MS. The inorganic chemical forms of iodine are chemically reactive, and so is the tank waste. The chemistry must be carefully designed to avoid unintended reactions that could convert one form of iodine to another during the analysis, which would skew the data and report iodine in the wrong chemical form. This iodine analysis, developed at PNNL, is being transferred to the DOE 222-S Laboratory on the Hanford Site, in Washington State, for implementation during waste processing operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Follow-on Report of Analysis of Approaches to Supplemental Treatment of Low-Activity Waste at the Hanford Nuclear Reservation (Vol. I)

The Hanford Site, in southeast Washington State, is preparing to disposition approximately 56,000,000 gallons (56 Mgal) of radioactive and chemically hazardous wastes currently stored in underground tanks at the site. Tank wastes will be divided into a high-activity fraction and a low-activity fraction for subsequent treatment and disposition. A waste processing and treatment facility, the Waste Treatment and Immobilization Plant (WTP), will include the high-level waste (HLW) vitrification facility (WTP HLW Vitrification Facility) for immobilizing the high-activity fraction and a low-activity waste (LAW) vitrification facility (WTP LAW Vitrification Facility) for immobilizing the low-activity fraction. Both facilities will use vitrification technology to immobilize the Hanford tank wastes in a glass waste form. The volume of LAW to be treated and disposed of following waste retrieval and WTP operations will exceed the planned processing capacity of the WTP LAW Vitrification Facility. ORP-11242,-River Protection Project System Plan, estimates a shortfall in LAW treatment capacity of approximately 56 Mgal, approximately 50% of the projected LAW volume. To maintain the planned tank waste processing mission schedule, the U.S. Department of Energy (DOE) will require additional LAW treatment capacity (termed “supplemental LAW”) external to the WTP process. LAW must be solidified by a treatment technology before the waste can be permanently disposed of in an approved DOE on-site disposal facility or a commercial (state or U.S. Nuclear Regulatory Commission [NRC-licensed]) off-site mixed low-level waste disposal facility. A decision on the approach to supplemental LAW treatment, processing, and disposal has not yet been made

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sediment Mineralogy Data Review for the Hanford Central Plateau

The compendium of Hanford site sediment mineralogy data provided in this report was initiated in 2012 to support flux mitigation technologies and real-time monitoring that could limit contaminant fluxes to the groundwater in the Central Plateau. Recent efforts in advancing spectral induced polarization as a method for monitoring contaminant transformations for active biogeochemical remedies have underscored the need for a published compendium of sediment characterization data. Although the data are primarily focused on the mineralogical composition of Hanford sediments, other soil measurements such as particle size distribution such as particle size distribution and carbon content are provided. The data have been reproduced from the original reports and are provided here for information only (FIO).

58 GEOSCIENCES↗

Part II: Predicting performance of $\mathrm{DOWEX 21K}$ resin for remediation of comingled contaminants in groundwater

The selectivity of ion exchange (IX) resins for aqueous contaminant removal can be impacted by changing concentrations of competing natural groundwater ions. In a two-part investigation, the Hanford Site 200 West Area pump-and-treat (P&T) facility in Washington State, USA is used as a case study to evaluate the performance of two IX resins for groundwater treatment: Purolite® A532E for pertechnetate (TcO 4 - ) removal, explored in Part I, and DOWEX 21K (DOWEX) for uranium (U) removal. In Part II, DOWEX selectivity for U, as uranyl carbonate species, and uptake kinetics is quantified in a series of laboratory-scale aqueous batch experiments containing Hanford-relevant concentrations of competing anions nitrate (NO 3 - ), sulfate (SO 4 2- ), chloride (Cl - ), and carbonate (CO 3 2- ), as well as co-mingled contaminant TcO 4 - . Here the results demonstrate that DOWEX trimethylammonium functional groups are highly selective for U carbonate species (85–100 % uptake) under all conditions investigated. Only NO 3 - concentrations of 100 mM were shown to decrease U removal, with the extent (85–99 %) depending on competing anion concentrations present in solution. However, at the highest NO 3 - concentrations reported for groundwaters treated at the P&T facility (25 mM), the effect on U uptake is minimal. The batch sorption results are modeled to obtain chloride normalized equilibrium exchange coefficients (K) for predicting DOWEX performance: K SO4--/Cl- = 2.0, K NO3-/Cl- = 5.0, K HCO3-/Cl- = 1.5, K TcO4-/Cl- = 2,000, and K U/Cl- = 50,000. These K values predict little effect of current and future influent chemistries on U removal by DOWEX, where both uranyl carbonate species and TcO 4 - are removed such that effluent concentrations meet groundwater treatment requirements.

54 ENVIRONMENTAL SCIENCES↗

Quantification of Raman-Interfering Polyoxoanions for Process Analysis: Comparison of Different Chemometric Models and a Demonstration on Real Hanford Waste

The Hanford site represents a complicated environmental remediation challenge, remaining from the production of nuclear weapons. Over 100 million gallons of liquid radioactive waste of unknown composition will be chemically processed and vitrified, but the varying chemical composition and highly radioactive nature of the waste preclude the implementation of more developed, offline technologies to determine the composition. The only practical approach to waste treatment will require the significant utilization of real-time, chemometric modeling approaches. Although chemometric approaches have been applied to the analysis of Hanford waste, the models developed were highly tank-specialized, and limited discussion was provided on how models fared with interfering signals. As the tank waste is largely composed of oxoanions, which tend to have interfering Raman spectra, the general question was posed as to what chemometric approach is best suited to accurately quantify analytes in the presence of interfering signals. This was carried out by examining the ability of classical least square (CLS), principal component regression (PCR), partial least square (PLS), and locally weighted regression (LWR) to quantify NO 3 – and CO 3 2– using their bands around 1050 cm –1 . Finally, for all samples, the PLS-based model was found to be the most efficient approach from a model building and application perspective.

54 ENVIRONMENTAL SCIENCES↗

Follow-on Report of Analysis of Approaches to Supplemental Treatment of Low–Activity Waste at the Hanford Nuclear Reservation (Volumes I & II)

The Hanford Site, in southeast Washington State, is preparing to disposition approximately 56,000,000 gallons (56 Mgal) of radioactive and chemically hazardous wastes currently stored in underground tanks at the site. Tank wastes will be divided into a high-activity fraction and a low-activity fraction for subsequent treatment and disposition. A waste processing and treatment facility, the Waste Treatment and Immobilization Plant (WTP), will include the high-level waste (HLW) vitrification facility (WTP HLW Vitrification Facility) for immobilizing the high-activity fraction and a low-activity waste (LAW) vitrification facility (WTP LAW Vitrification Facility) for immobilizing the low-activity fraction. Both facilities will use vitrification technology to immobilize the Hanford tank wastes in a glass waste form.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Follow-On Report of Analysis of Approaches to Supplemental Treatment of Low-Activity Waste at the Hanford Nuclear Reservation (Volumes I & II)

The Hanford Site, in southeast Washington State, is preparing to disposition approximately 56,000,000 gallons (56 Mgal) of radioactive and chemically hazardous wastes currently stored in underground tanks at the site. Tank wastes will be divided into a high-activity fraction and a low-activity fraction for subsequent treatment and disposition. A waste processing and treatment facility, the Waste Treatment and Immobilization Plant (WTP), will include the high-level waste (HLW) vitrification facility (WTP HLW Vitrification Facility) for immobilizing the high-activity fraction and a low-activity waste (LAW) vitrification facility (WTP LAW Vitrification Facility) for immobilizing the low-activity fraction. Both facilities will use vitrification technology to immobilize the Hanford tank wastes in a glass waste form.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Findings from Large Bench-Scale Testing of Denitration Electrolyzers for the EDCGe Project

This report highlights the key findings and outcomes relevant to the processability of waste supernatant at Hanford using a denitration electrolyzer. The Electrosynthesis Company issued a Phase 1 report to the Savannah River National Laboratory (SRNL), summarizing the evaluation of large bench-scale denitration electrolyzers to support the electrochemical denitration and caustic generation (EDCGe) project. The Electrosynthesis Company’s report (attached as Appendix A) provides insights into the initial steps required to implement an electrolyzer system at Hanford. Phase 1 experiments focused on validating the denitration electrolyzer’s performance, operating parameters, and reaction products. The robustness of the electrochemical denitration process was demonstrated by two electrolyzer flow cell systems (a 100 cm 2 ElectroCell MP and a 150 cm 2 NESI NS01 cell), both of which achieved significant nitrate and nitrite removal (>50%) with a current efficiency of ~95% for both systems. Higher current densities (500 mA cm –2 ) improved nitrate and nitrite removal rates compared to lower current densities (333 mA cm –2 ), while maintaining a current efficiency of ~94%. The NS01 cell achieved a nitrate species removal rate of ~0.41 mol h –1 at 5 kA m –2 (equiv. to 500 mA cm –2 ). The primary reaction product was ammonia (NH 3 ), constituting 78.3–91.6% of the products (excluding OH – formation). NH 3 was predominantly retained in the catholyte liquid phase rather than being off-gassed. Additionally, the NS01 cell reported an NH 3 generation rate of ~0.36 mol h –1 at 5 kA m –2 . Other gas formation included ~7% N 2 , ~7% H 2 , and trace amounts of N 2 O. The estimated power requirement (extrapolated from the 0.015 m 2 cell data) for a full-scale denitration electrolyzer is approximated to be ~1.6 MW (DC-only) to treat 50% of nitrate and nitrite in a waste stream and generates ~2.1 kmol h –1 of NH 3 with an initial concentration of 4 M NO 3 – /NO 2 – at 300 gal h –1 . Simulated waste containing aluminate, carbonate, oxalate, and halogens exhibited no adverse effects on denitration performance. A preliminary experiment comparing alkaline anolyte (5 M NaOH) with a nickel based anode to acidic media (2 M H 2 SO 4 ) with a DSA-O 2 anode showed a lower operating voltage and generated less H 2 than the acid media. Maintaining a stable 5 M OH – concentration in the anolyte through periodic additions of caustic did not significantly impact denitration performance. This operational mode will be required for long-term experiments. All the experiments demonstrated that electrochemical denitration is a promising approach for treating nitrate and nitrite in simulated waste streams, achieving significant conversion and robustness across varying experimental conditions and electrochemical cell configurations. Lastly, the ability to generate a nearly pure NH 3 stream may prove advantageous for processing at other locations within the Hanford site.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Predicting future well performance for environmental remediation design using deep learning

Here in this study, we developed a deep learning (DL) framework with a multi-channel three-dimensional convolutional neural network (MC3D-CNN) to predict well performance and thereby assist future environmental remediation design. Such prediction of extraction well performance at designated locations is critical for configuring pump-and-treat (P&T) well network design and operation, setting reasonable target closure dates for overall remedying, and estimating remedy costs. The framework is developed with operational and monitoring data routinely collected during P&T remedy operations, including well extraction and injection rates as well as in situ contaminant concentrations. Traditionally, the collected data were rarely used for purposes other than assessing past well performance and the accuracy of the conceptual site model. However, recent advances in data-driven computational approaches enable better use of the large datasets to inform future well performance, enhance site characterization, and improve remediation planning. In this study, we established a DL framework to integrate transient three-dimensional contaminant plumes and multiple aquifer properties (e.g., hydraulic conductivity and hydrostratigraphic maps) to identify characteristic patterns controlling and representing extraction well mass recovery, aiming at providing future mass recovery estimates for existing wells and candidate wells at any proposed locations. We evaluated our framework by using a realistic synthetic dataset generated from a well-calibrated flow and transport model used in the 200 West Area of the U.S. Department of Energy’s Hanford Site in southeastern Washington state. The multi-channel feature in our framework allows integration of various types and temporal densities of training datasets for DL model development. Overall, we found that the trained DL model achieved an accuracy of over 90% in ranking extraction well performance in validation datasets, and over 80% in predicting high-performance-ranking well locations. This data-informed approach provides a flexible tool to support adaptive site management, streamline decision-making, and potentially reduce remediation time and costs. Our DL framework can be used as a filtering tool to improve the current P&T network optimization design by reducing the number of candidate well locations.

54 ENVIRONMENTAL SCIENCES↗