SEARCH · Engineering Papers
Results for “HARDNESS”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Following the in-plane disorder of sodiated hard carbon through operando total scattering
Abstract not provided
Coupled hard–soft spinel ferrite-based core–shell nanoarchitectures: magnetic properties and heating abilities
The heating abilities of bi-magnetic core–shell nanostructures are studied depending on core size, nature of the shell, and shell thickness.
New reflections on hard X-ray photon-in/photon-out spectroscopy
Analysis of the electronic structure and local coordination of an element is an important aspect in the study of the chemical and physical properties of materials. This is particularly relevant at the nanoscale where new phases of matter may emerge below a critical size. X-ray emission spectroscopy (XES) at synchrotron radiation sources and free electron lasers has enriched the field of X-ray spectroscopy. Additionally, the spectroscopic techniques derived from the combination of X-ray absorption and emission spectroscopy (XAS–XES), such as resonant inelastic X-ray scattering (RIXS) and high energy resolution fluorescence detected (HERFD) XAS, are an ideal tool for the study of nanomaterials. New installations and beamline upgrades now often include wavelength dispersive instruments for the analysis of the emitted X-rays. With the growing use of XAS–XES, scientists are learning about the possibilities and pitfalls. We discuss some experimental aspects, assess the feasibility of measuring weak fluorescence lines in dilute, radiation sensitive samples, and present new experimental approaches for studying magnetic properties of colloidal nanoparticles directly in the liquid phase.
HANNA: hard-constraint neural network for consistent activity coefficient prediction
We introduce HANNA, the first hybrid neural network model that strictly complies with all thermodynamic consistency criteria for predicting activity coefficients and outperforms current benchmark methods in terms of accuracy and applicability.
Provider Perspectives: Identification and Follow-up of Infants who Are Deaf or Hard of Hearing
Objective Without timely screening, diagnosis, and intervention, hearing loss can cause significant delays in a child's speech, language, social, and emotional development. In 2019, Texas had nearly twice the average rate of loss to follow-up (LFU) or loss to documentation (LTD; i.e., missing documentation of services received) among infants who did not pass their newborn hearing screening compared to the United States overall (51.1 vs. 27.5%). We aimed to identify factors contributing to LFU/LTD among infants who do not pass their newborn hearing screening in Texas. Study Design Data were collected through semistructured qualitative interviews with 56 providers along the hearing care continuum, including hospital newborn hearing screening program staff, audiologists, primary care physicians, and early intervention (EI) program staff located in three rural and urban public health regions in Texas. Following recording and transcription of the interviews, we used qualitative data analysis software to analyze themes using a conventional content analysis approach. Results Frequently cited barriers included problems with family access to care, difficulty contacting patients, problems with communication between providers and referrals, lack of knowledge among providers and parents, and problems using the online reporting system. Providers in rural areas more often mentioned problems with family access to care and contacting families compared to providers in urban areas. Conclusion These findings provide insight into strategies that public health professionals and health care providers can use to work together to help further increase the number of children identified early who may benefit from EI services. Key Points
A large field-of-view high-resolution hard x-ray microscope using polymer optics
Here, we present an effective approach using a matched pair of polymer-based condenser-objective lenses to build a compact full-field X-ray microscope with a high spatial resolution. A unique condenser comprising arrays of high-aspect-ratio prisms with equilateral cross-section is used for uniformly illuminating samples over a large field of view (FoV) from all angles, which match the acceptance of an objective made of interdigitated orthogonal rows of one-dimensional lenses. State-of-the-art Talbot grating interferometry used to characterize these lenses for the first time revealed excellent focusing properties and minimal wave-front distortions. Using a specific lens-pair designed for 20 keV X-rays, short-exposure times, and image registration with a cross-correlation technique, we circumvent vibrational instabilities to obtain distortion-free images with a uniform resolution of 240 nm (smallest resolvable line pair) over a large FoV, 80 × 80 µm 2 in extent. The results were contrasted with those collected under illumination using commercial two-dimensional parabolic lenses with a smaller FoV. This approach implemented on a diffractometer would enable diffraction-contrast or dark-field microscopy for fast observations of ‘mesoscopic’ phenomena in real space complementing reciprocal-space studies using diffraction on the same instrument.
High resolution x-ray emission spectrometer for multiple hard x-ray emission lines: Demonstration for Cu Kα and Kβ emissions
In this work, we present a compact 3D printed x-ray emission spectrometer based on the von Hamos geometry that represents a significant upgrade to the existing von Hamos geometry-based miniature x-ray emission spectrometer (miniXES). The upgrades include the incorporation of a higher pixel density 500K detector for improved energy resolution and an enlarged sample area to accommodate a wider range of sample formats. The versatile spectrometer houses removable crystal holders that can be easily exchanged, as well as movable alignment eyelets that give flexibility in Bragg angle selection. Designed for ease of manufacture, all the components, except for the apertures, can be 3D printed and readily assembled. We describe its implementation in measurements of resonant and non-resonant Cu Kα and Kβ x-ray emission and report the theoretical and measured energy resolution and collected solid angle of the emission.
Platform development towards ultra-intense laser-based simultaneous hard X-ray and MeV neutron multimodal radiography
Explore the source record for details and available documents.
Generation of intense phase-stable femtosecond hard X-ray pulse pairs
Significance The generation of phase-stable femtosecond X-ray pulse pairs will advance nonlinear spectroscopies and imaging, providing direct insight into the coupled motions of electrons and nuclei with resolution on the electronic length scale and timescale. This paper presents the generation of such pulse pairs in the X-ray domain. The approach uses X-ray free-electron laser pulses to induce highly directional, intense, phase-stable pairs of superfluorescence and seeded stimulated emission at the 5.9 keV manganese Kα 1 line. The finding is evidenced by strong interference fringes in the superfluorescence and stimulated emission signals.
Advances in Operando Electrocatalysis with High-Resolution Hard X-Ray Spectroscopy
Electrocatalysis unfolds at the interface—where solids, liquids, and gases meet to exchange charge, transform molecules, and set the foundation for technologies like CO 2 conversion, and water splitting. These interfacial regions are inherently dynamic, chemically diverse, and structurally heterogeneous. How atoms rearrange, oxidize, coordinate ligands, or adsorb reaction intermediates under electro-chemical potential defines a catalyst’s performance. Furthermore, capturing these changes with element specificity and electronic sensitivity under operando conditions remains one of the most critical challenges in the field.
High-throughput evaluation of half-metallicity of Co 2 MnSi Heusler alloys using composition-spread films and spin-integrated hard X-ray photoelectron spectroscopy
Not Available
Role of mechanical stress localizations on the radiation hardness of AlGaN/GaN high electron mobility transistors
Multi-material, multi-layered systems such as AlGaN/GaN high electron mobility transistors (HEMTs) contain residual mechanical stresses that arise from sharp contrasts in device geometry and materials parameters. These stresses, which can be either tensile or compressive, are difficult to detect and eliminate because of their highly localized nature. We propose that their high-stored internal energy makes potential sites for defect nucleation sites under radiation, particularly if their locations coincide with the electrically sensitive regions of a transistor. In this study, we validate this hypothesis with molecular dynamic simulation and experiments exposing both pristine and annealed HEMTS to 2.8 MeV Au +3 irradiation. Our unique annealing process uses mechanical momentum of electrons, also known as the electron wind force (EWF) to mitigate the residual stress at room temperature. High-resolution transmission electron microscopy and cathodoluminescence spectra reveal the reduction of point defects and dislocations near the two-dimensional electron gas region of EWF-treated devices compared to pristine devices. The EWF-treated HEMTs showed relatively higher resilience with approximately 10% less degradation of drain saturation current and ON-resistance and 5% less degradation of peak transconductance. Both mobility and carrier concentration of the EWF-treated devices were less impacted compared to the pristine devices. Our results suggest that the lower density of nanoscale stress localization contributed to the improved radiation tolerance of the EWF-treated devices. Intriguingly, the EWF is found to modulate the defect distribution by moving the defects to electrically less sensitive regions in the form of dislocation networks, which act as sinks for the radiation induced defects and this assisted faster dynamic annealing.
LAMBDA 2M GaAs-A multi-megapixel hard X-ray detector for synchrotrons
Explore the source record for details and available documents.
Effect of deep gain layer and Carbon infusion on LGAD radiation hardness
Not provided.
Characterization of 128 × 128 MM-PAD-2.1 ASIC: a fast framing hard x-ray detector with high dynamic range
Here, we characterize a new x-ray Mixed-Mode Pixel Array Detector (MM-PAD-2.1) Application Specific Integrated Circuit (ASIC). Using an integrating pixel front-end with dynamic charge removal architecture, the MM-PAD-2.1 ASIC extends the maximum measurable x-ray signal (in 20 keV photon units) to > 10 7 x-rays/pixel/frame while maintaining a low read noise across the full dynamic range, all while imaging continuously at a frame rate of up to 10 kHz. The in-pixel dynamic charge removal mechanism prevents saturation of the input amplifier and proceeds in parallel with signal integration to achieve deadtime-less measurements with incident x-ray rates of > 10 10 x-rays/pixel/s. The ASIC format consists of 128 × 128 square pixels each 150 μm on a side and is designed to be 3-side buttable so large arrays can be effectively tiled. Here we use both laboratory x-ray sources and the Cornell High Energy Synchrotron Source (CHESS) to characterize two single ASIC prototype detectors for both low (single x-ray) and high incident flux detection. In the first detector the ASIC was solder bump-bonded to a 500 μm thick Si sensor for efficient detection of x-rays below 20 keV, whereas the second detector used a 750 μm thick CdTe sensor for x-rays above ~20 keV.
Automated Cryo-TEM of Highly Beam-Sensitive Hard-Soft Ionomer Interfaces in Green Hydrogen Devices
Explore the source record for details and available documents.