Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids: Preprint

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. Different types of DERs such as Photovoltaics (PV), energy storage, electric vehicles (EVs), etc. have varying effects on the grid based on how and where they are deployed. Again, the DER deployment and its impact are network-dependent, while the traditional electric grids were not designed to host DERs. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper investigates the impacts of integrating a mix of DERs in the utility distribution network in Colorado, U.S. Firstly, BTM DERs at the residential scale including distributed PV; battery energy storage systems (BESS); heating, ventilation, and air-conditioning (HVAC) load; electric water heater (EWH) load; and EVs are modeled. The impacts of integrating these resources on the distribution network are evaluated by conducting time-series simulations for different scenarios considering different days to capture the worst-case conditions. Monte Carlo simulations are conducted to generate the realistic EV charging profile. The voltage issues, substation transformer loadings, and critical nodes in the network are identified with the incorporation of uncoordinated EV charging loads and other DER in the network. This analysis helps visualize the DER impact on the grid, identify the challenges, and provides an insight into the new distribution management and control needs to enable reliable and resilient distribution grid operations. Additionally, further analysis is performed to estimate the daily residential electricity cost with the inclusion of DERs under time-of-use tariffs. The result shows the daily residential electricity cost reduced by 20:7% on average with DERs compared to the case without DERs.

27 ARPA - Advanced Research Projects Agency-Energy↗

Characterization of Connected Lighting System Potential for Grid Services Under Real-Time Pricing

Increasingly over the last decade, the management of end-use electricity demand has been examined as a potential source of services for the electric power grid beyond contracts with large commercial and industrial customers. Lighting represents about 17\% of U.S. commercial building annual electricity consumption; however, its potential rapid speed of response may position it to uniquely contribute to services that improve the reliability and resilience of the grid. Connected lighting systems (CLS), which build upon solid-state lamp technology, can change state by adjusting power demand more quickly than most other building electricity end uses and could be used as a platform to monitor lighting electricity use and space conditions. But the potential of CLS to provide grid services has not been extensively studied. In this paper, we describe initial research to evaluate the potential of CLS for grid services. We develop a model for CLS using a set of parameters to represent operation behaviors and constraints: maximal power, minimal power, nominal power, ramp rate, and time delay. Parameter values are generated for representative building types. CLS demand curves are constructed, indirectly capturing building occupant preferences for lighting as functions of electricity price. The CLS model and the demand curves are incorporated into a Transactive Control and Coordination (TCC) Platform to simulate CLS providing grid services. Previous research has shown TCC to be a powerful tool to enable end uses to provide grid services through a hybrid economic-control approach. Initial quantitative results will be provided for CLS grid services potential.

Wang, Peng↗

Achieving American Leadership in the Electric Grid Supply Chain Factsheet

The U.S. electric grid consists of more than 22,000 generators; 55,000 substations; 642,000 miles of high-voltage lines; and 6.3 million miles of distribution lines that serve 153 million customers. To date, much of the smart grid transformation has focused on applying advanced digital information and communication technologies to the power grid to improve the system’s efficiency, flexibility, and security. To achieve the full value of grid modernization, we also need advances in grid hardware. Many critical components supporting the power grid have limited to no domestic manufacturing capacity and face complex challenges in supporting a rapid expansion of the grid to meet multiple objectives, including decarbonization goals.

Source record↗

How to Build a Connected Community: Policies to Promote Grid-interactive Efficient Buildings and Demand Flexibility

Efficient, connected, grid-interactive, smart, and flexible buildings are key to decarbonizing the U.S. energy economy, optimizing energy use, reducing electric consumers’ bills, integrating variable renewable energy resources, and improving the reliability and performance of the nation’s electricity grids. Such grid-interactive efficient buildings have high levels of energy efficiency layered with other distributed energy resources (DERs) and intelligent controls to provide demand flexibility. Policy support is unfolding at the federal, state, and local levels to transform homes and workplaces into state-of-the-art energy-efficient buildings and community-level grid services. This paper starts by describing the potential benefits. Next, it highlights existing policies — with a focus on state-level actions — that support grid-interactive efficient building deployment and demand flexibility. Finally, it identifies current trends and gaps, policies and programs that promote grid-interactive efficient buildings, and aggregations of grid-interactive efficient buildings referred to as Virtual Power Plants.

Schwartz, Lisa C↗

Hydropower Role in a Power Grid with a High Proportion of Variable Renewables

The importance of hydropower increases as the power grid evolves with the higher variable renewable contribution. As conventional thermal power plants are retired, the importance of hydropower contribution increases to balance the variability of solar and wind generation. However, reservoir water resources are constrained by multiple constraints, and variability of water inflow to the reservoirs creates limitations to dam water releases for power grid needs. Coordination of multiple tools, including water resources modeling, ecological modeling, and technical and economic power grid modeling, informs dam water releases. Better representation of ecological constraints and other water use details in the suit of power grid models are required to identify the hydropower flexibility to provide multiple power grid services. Impacts of water planning and hydropower operation changes to a power grid are better understood by production cost model simulations with technical and economic data, including unserved energy, reserve failures, transmission congestion to serve load, and local marginal price increases. Similarly, PCM simulation of current and future projected power grid information, including LMP, and carbon emission rates, informs short-term water release plans and long-term investments for power plant upgrades for technical and ecological needs. Hydropower operations of several case studies are simulated to understand operation patterns, revenue, water release decisions in multiple time scales (month, day, minutes), hydropower contracts scheduling, and water variability impacts.

environmental↗

Fish Friendly Water Rules' Impact On the Power Grid with High VRE Levels

Columbia River basin multipurpose reservoirs are operated for hydropower production and many other purposes considering the aquatic habitat of the river basin. Specifically, the river basin fish population is a vital element for the tribal community of the river basin. When conventional thermal power plants are retired, hydropower flexibility balances the wind and solar variability of the power grid and provides grid services to maximize the high renewable power absorption. On the other hand, over-reliance on hydropower could harm the river basin fish habitat. For example, water release pulses during peak electricity demand hours and shorter-term water release variation could harm the fish population. Power grid planners, environmentalists, Columbia Basin tribes, hydro regulators, and water resource planners work together to understand the impacts of Columbia River basin operation in a fish-friendly way in the current power grid and power grid with higher renewable power share. We examine different levels of renewable share in the Western Interconnection to understand the multiple weather years and future climate projection and operating scenario impact on the power grid and water system. We measure power grid impacts for various water resources planning scenarios in terms of total system operating cost, system reliability indicators, changes in wind and solar generation and curtailments, local marginal prices, and revenue for hydropower producers. The study results inform reservoir operating rules decisions from hydropower power producers, system operators, other water users, tribes, environmentalists, and other stakeholders.

environmental↗

Grid and Wind Transient Ride Through Assessment of Type-5 Synchronous Wind Turbine

The integration of the inverter-based renewable energy resources is increasing and replacing conventional synchronous generators in the evolving bulk power system (BPS), impacting the system inertia along the way. Also, the limited over-current capability of power electronic converters continues to deteriorate the grid strength of the evolving power systems. Type-5 wind turbines have the potential to mitigate these problems because this configuration interfaces with the grid through a synchronous generator; hence, its operation and consequent grid impacts might mimic the conventional synchronous generator. The drivetrain of this type of turbines, however, is different from the more common Type-3 and Type-4 turbines. A hydraulic torque converter and gearbox with torque limiting feature are integral parts of a Type-5 wind turbine drivetrain, to isolate the wind speed variations at the wind turbine rotor from the grid connected generator side. This supports the synchronous operation of the generator. However, high fidelity models of Type-5 wind turbine drivetrain including these core components are not openly and widely available for grid integration and transient stability studies. Moreover, Type-5 turbines are not commonly deployed and hence its power generation and frequency stability characteristics are not widely publicized. This hinders appropriate assessment of Type-5 wind power plant's contribution to bulk grid resilience. This work provides transient stability assessment of a standalone Type-5 wind turbine. Normal operation and grid transient studies are performed to see the step load change and wind speed disturbance impacts on the Type-5 drivetrain and generation dispatch. Preliminary results show that Type-5 wind turbines can support load changes of between 0.6 p.u to 1.15 p.u. Beyond this point, the synchronization of the generator starts to deviate from its set point.

17 - WIND ENERGY↗

Residual estimation for grid modification in wall-modeled large eddy simulation using unstructured high-order methods

Here, the accuracy and computational cost of a large eddy simulation are highly dependent on the computational grid. Building optimal grids manually from a priori knowledge is not feasible in most practical use cases; instead, solution-adaptive strategies can provide a robust and cost-efficient method to generate a grid with the desired accuracy. We adapt the residual estimation algorithm developed by Toosi and Larsson for Discontinuous Galerkin Spectral Elements Methods (DGSEM) to guide the grid-adaptation process. The core of the method is the computation of the estimated modeling residual using the polynomial basis functions used in DGSEM, and the averaging of the estimated residual over each element. The final method is assessed in multiple channel flow test cases and for the transonic flow over an airfoil, in both cases making use of mortar interfaces between elements with hanging nodes. The method is found to be robust and reliable, and to provide solutions on grids with significantly fewer elements at comparable accuracy compared to when using human-generated grids.

97 MATHEMATICS AND COMPUTING↗

Adaptation of virtual synchronous generators to dynamic conditions in power grids

Virtual synchronous generators (VSGs) are widely adopted as grid-forming controls for inverter-based resources. However, when grid conditions vary significantly as characterized by changes in short-circuit ratio (SCR) and the reactance-to-resistance (X/R) ratio, fixed-gain designs and the commonly used P–Q decoupling assumption can become inaccurate. Such conditions can degrade transient power performance, leading to oscillations, prolonged settling, and overshoot, particularly in stiff-grid operating points. This paper quantifies how grid strength and impedance-dependent coupling affect the active–reactive power dynamics of a conventional VSG over a broad range of SCR and X/R values. An adaptive VSG tuning framework is then developed by combining (i) a coupling-explicit, impedance-parameterized state-space model to enable systematic controller synthesis, (ii) a full-state-feedback law designed via pole placement to meet prescribed damping and settling-time specifications, and (iii) a physics-informed neural network (PINN)–based online grid-impedance estimator that updates controller gains in real time as grid conditions vary. Offline simulations in MATLAB/Simulink and real-time validation on an OPAL-RT platform show that the proposed method preserves consistent damping and settling behavior with reduced overshoot across wide SCR and X/R ranges, compared with fixed-gain VSG baselines.

Adaptive control↗

Sequence Impedance Modeling of Grid-Forming Inverters

Grid-forming control of inverter-based resources has been identified as a critical technology for operating power systems with high levels of inverter-based resources. This paper presents the sequence impedance modeling of a grid-forming inverter to evaluate its small-signal stability properties. Droop control structure is implemented to control the inverter in grid-forming mode, and the impact of individual controller on the inverter impedance characteristics is discussed. The developed sequence impedance model is compared with that of the grid-following inverter. It is found from the developed sequence impedance models that grid-forming inverters are less prone to harmonic resonance problems during operation with weaker grids. The developed models are validated using PSCAD simulations.

grid- following inverter↗

Tractable Learning in Underexcited Power Grids

Estimating the structure of physical flow networks, such as power grids, is critical to secure delivery of energy. This article discusses statistical structure estimation in power grids in the “underexcited” regime, where a subset of internal nodes has zero injection fluctuations. Prior estimation algorithms based on nodal voltages fail for such grids as the voltage covariance matrix is not invertible. Here, we propose a novel topology learning algorithm for learning underexcited general networks. Our algorithm uses physics-informed conservation laws to first identify the zero-injection buses and their neighbors, and then estimates the remaining edges in the grid. We prove the asymptotic correctness of our algorithm for grids with nonadjacent internal zero-injection nodes. More important, we theoretically analyze our algorithm’s efficacy under noisy measurements, and determine bounds on maximum noise under which asymptotically correct recovery is guaranteed. Our approach is validated through simulations with voltage samples generated on test distribution grids with real injection data and nonlinear power flow models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Simple and Accurate Energy-Detector-Based Transient Waveform Detection for Smart Grids: Real-World Field Data Performance

Integration of distributed energy sources, advanced meshed operation, sensors, automation, and communication networks all contribute to autonomous operations and decision-making processes utilized in the grid. Therefore, smart grid systems require sophisticated supporting structures. Furthermore, rapid detection and identification of disturbances and transients are a necessary first step towards situationally aware smart grid systems. This way, high-level monitoring is achieved and the entire system kept operational. Even though smart grid systems are unavoidably sophisticated, low-complexity algorithms need to be developed for real-time sensing on the edge and online applications to alert stakeholders in the event of an anomaly. In this study, the simplest form of anomaly detection mechanism in the absence of any a priori knowledge, namely, the energy detector (also known as radiometer in the field of wireless communications and signal processing), is investigated as a triggering mechanism, which may include automated alerts and notifications for grid anomalies. In contrast to the mainstream literature, it does not rely on transform domain tools; therefore, utmost design and implementation simplicity are attained. Performance results of the proposed energy detector algorithm are validated by real power system data obtained from the DOE/EPRI National Database of power system events and the Grid Signature Library.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sequence Impedance Modeling of Grid-Forming Converters: Preprint

Grid-forming control of inverter-based resources (IBRs) has been identified as a critical technology for operating power systems with high levels of inverter-based resources. This paper presents sequence impedance modeling of grid-forming inverters to evaluate its small-signal stability properties. Droop based grid-forming control with full consideration of the multiloop structure is studied, and the impact of individual controller on the inverter impedance characteristics is discussed. The developed sequence impedance model is compared with that of the grid-following inverter. It is found from the developed sequence impedance models that grid-forming inverters are less prone to harmonic resonance problems during operation with weaker grids. The developed models are validated using PSCAD simulations.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Sequence Impedance Modeling of Grid-Forming Inverters

Grid-forming control of inverter-based resources has been identified as a critical technology for operating power systems with high levels of inverter-based resources. This paper presents the sequence impedance modeling of a grid-forming inverter to evaluate its small-signal stability properties. Droop control structure is implemented to control the inverter in grid-forming mode, and the impact of individual controller on the inverter impedance characteristics is discussed. The developed sequence impedance model is compared with that of the grid-following inverter. It is found from the developed sequence impedance models that grid-forming inverters are less prone to harmonic resonance problems during operation with weaker grids. The developed models are validated using PSCAD simulations.

grid-following inverter↗

Electricity Markets and Long-Duration Energy Storage: A Survey of Grid Services and Revenue Streams

Purpose of Review Long Duration Energy Storage (LDES) is increasingly viewed as a potential resource for providing grid services that enhance the stability and flexibility of electricity systems. While some LDES services are integrated into existing market frameworks, traditional mechanisms may not fully account for their operational characteristics, potentially leading to undervaluation. Within this context, this paper reviews the literature and industry practices to assess potential grid services for LDES, evaluates existing compensation mechanisms, and identifies challenges to full market integration. Recent Findings We first review existing literature and identify key grid services unique to LDES, including enhancing grid resilience during extreme weather events, enabling long-term energy shifting, and providing flexible and firm energy in systems with limited dispatchable resources. Here, we also review how LDES services are compensated in current market frameworks and the challenges associated with the full realization of LDES values. Additionally, we summarize market mechanisms for storage technologies across U.S. wholesale markets. We find that some markets are adjusting incentive structures, such as incorporating storage duration in capacity accreditation, to better align with system needs and LDES contributions to the grid. However, further refinements in capacity remuneration and dispatch timeframes may be needed for more effective realization of LDES value. Summary This review evaluates potential grid services for LDES, examines existing compensation mechanisms for LDES technologies, and identifies gaps between these mechanisms and LDES operational characteristics. The review concludes by outlining potential market enhancements for more effective LDES integration and articulating additional research needs to support its efficient participation in future power systems.

Flexible resources↗

Non-orthogonal computational grids for studying dislocation motion in phase field approaches

In this work, new non-orthogonal computational grids are implemented into a phase field model called Phase Field Dislocation Dynamics (PFDD). We demonstrate that the new non-orthogonal grid can accommodate multiple slip planes in either the face centered cubic (FCC) or body centered cubic (BCC) crystallographic systems. Here, we show that they avoid numerical errors induced when modeling glide on inclined slip planes in an orthogonal grid. The Gibbs effect that arises in the orthogonal or rotated orthogonal grids is substantially diminished when a non-orthogonal grid is employed. A few test cases demonstrate the effectiveness of using non-orthogonal grids in solving systems with multiple non-planar slip systems.

36 MATERIALS SCIENCE↗

Thermal and electric multidomain dynamic model for integration of power grid distribution with behind-the-meter devices

As renewable energy sources like solar and wind power become more integrated into the grid, coordinated control of behind-the-meter devices is crucial for enhancing grid flexibility and reliability and for meeting cost targets, with standardized models being developed to support this transition. The increasing flexibility and uncertainty of integrated renewable energy grids, along with interactions between various subsystems, make traditional steady-state modeling insufficient to capture transient and dynamic behaviors. Current models (e.g., composite load and battery equivalent models) focus on thermodynamic or electrical characteristics but overlook critical electromechanical interactions. This limits the ability to share performance information for grid services and hampers fast dynamic simulations. In addition, motor stalling is usually triggered by a fault event and attributed to the characteristics of the mechanical torque of the motor, resulting in absorption of a large amount of reactive power during the stalling period. Further, this significant withdrawal of reactive power will deteriorate the dynamic voltage stability of power grids and cause delayed voltage recovery. Therefore, an in-depth modeling of the thermodynamics or mechanical torque is essential to study the impacts of the realistic torque characteristics of those behind-the-meter devices on power system voltage stability. This study developed a dynamic multidomain model for building HVAC systems, such as air-source heat pumps, to simulate their thermal and electrical responses to grid transients. The model can accurately predict power metrics with a mean absolute percentage error of 10%, by validating against with power system computer-aided design performance data. Case studies demonstrate the model capability of capturing the transient response to sudden voltage changes, rapid load fluctuations, and system shutdowns respectively. During a sudden voltage drop (30% for 0.1s), a fully loaded heat pump’s motor speed dropped, continued declining, and shut down after 3.6s, with severe power oscillations and a torque spike. A partially loaded unit experienced temporary oscillations but stabilized. Under higher building loads, compressor speed increased from 64% to 100%, with power and torque rising before stabilizing. In safety-triggered shutdowns, power decreased after minor fluctuations, and torque briefly spiked before dropping to zero.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Propagation of non-Gaussian voltage angle fluctuations in high-voltage power grids

Recent measurements have reported non-Gaussian tails in the distribution of frequency data in electric power grids. Large frequency deviations may induce grid instabilities and it is therefore crucial to understand how noise disturbances with long, non-Gaussian tails propagate. Here, we investigate how fluctuations in power feed-in, characterized by non-zero cumulants of their distribution, propagate through high-voltage power grids. Unlike previous investigations which focused on the white-noise limit, we consider the limit of long noise correlation time, where power feed-in fluctuates over times longer than the inherent dynamical time scales of the grid - the relevant regime for large-scale, high-voltage distribution grids. In this work, we show that in this limit, the skewness and kurtosis of the power feed-in distribution propagate similarly as its variance, independently of the distribution of inertia. Non-Gaussianities from individual sources of noise therefore persist throughout the entire network. This finding is corroborated by numerical results on a realistic model of the synchronous grid of continental Europe.

42 ENGINEERING↗