Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gas Receiver”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Recent Stirling Conversion Technology Developments and Operational Measurements at NASA Glenn Research Center

In support of the Advanced Stirling Radioisotope Generator (ASRG) project and other potential applications, NASA Glenn Research Center (GRC) has initiated convertor technology development efforts in the areas of acoustic emission, electromagnetic field mitigation, thermoacoustic Stirling conversion, and multiple-cylinder alpha arrangements of Stirling machines. The acoustic emission measurement effort was developed as a health monitoring metric for several Stirling convertors undergoing life testing. While accelerometers have been used in the past to monitor dynamic signature, the acoustic sensors were chosen to monitor cycle events, such gas bearing operation. Several electromagnetic interference (EMI) experiments were performed on a pair of Advanced Stirling Convertors (ASC). These tests demonstrated that a simple bucking coil was capable of reducing the alternating current (ac) magnetic field below the ASRG system specification. The thermoacoustic Stirling concept eliminates the displacer typically found in Stirling machines by making use of the pressure oscillations of a traveling acoustic wave. A 100 W-class thermoacoustic Stirling prototype manufactured by Northrop Grumman Space and Technology was received and tested. Another thermoacoustic prototype designed and fabricated by Sunpower, Inc., will be tested in the near future. A four cylinder free piston alpha prototype convertor was received from Sunpower, Inc. and has been tested at GRC. This hardware was used as a proof of concept to validate thermodynamic models and demonstrate stable operation of multiple-cylinder free-piston Stirling conversion. This paper will discuss each of these activities and the results they produced.

Oriti, Salvatore M.↗

X-ray spectrum of the entire Cygnus Loop.

The spectrum of the entire Cygnus Loop has been obtained using gas-filled proportional counters and filters flown on a Nike-Aerobee rocket. The results indicate an average spectral temperature of (2.8 plus or minus 0.2) x 1,000,000 K and the presence of excess emission in the energy range from 0.530 to 0.693 keV. If the excess emission originates in a single line at 0.658 keV, the intensity at the earth corresponds to 1.8 plus or minus 0.7 photons per sq cm per sec, or about 10% of the total energy received from the Loop. The spectrum of the entire Loop is found to be attenuated by an average of (4.8 plus or minus 0.2) x 10 to the 20th hydrogen atoms per sq cm.

Stevens, J. C.↗

Fluid Dynamics of a Pressure Reducing Inlet

Instruments for the monitoring of hazardous gases in and near the space shuttle collect sample gas at pressures on the order of one atmosphere and analyze their properties in an ultra-high vacuum by means of a quadrupole-mass-spectrometer partial pressure transducer. Sampling systems for such devices normally produce the required pressure reduction through combinations of vacuum pumps, fluid Tees and flow restrictors (e.g. orifices, sintered metal frits or capillaries). The present work presents an analytical model of the fluid dynamics of such a pressure reduction system which enables the calculation of the pressure in the receiver vessal in terms of system parameters known from the specifications for a given system (e.g. rated pumping speeds of the pumping hardware and the diameters of two orifices situated in two branches of a fluid Tee). The resulting formulas will expedite the fine tuning of instruments now under development and the design of later generations of such devices.

Russell, John M.↗

In-Situ Detection of Process-Induced Porosity During Cure of Out-of-Autoclave Composites

Composite materials offer unique benefits in aerospace applications, including high strength-to-weight ratio, and are becoming increasingly used by industry manufacturers. Current manufacturing and processing methods can lead to defects in the composites, which are identified after fabrication using inspection methods. This study utilized a high-temperature ultrasonic inspection system to detect process-induced porosity in an out-of-autoclave (OOA) composite panel during cure. In order to perform ultrasonic scans in-situ during cure, the system needed to be able to operate at oven temperatures up to 200 °C. There are no commercially available ultrasonic scanning systems that can operate continuously at these temperatures, so an enclosure was fabricated to insulate the ultrasonic system in the curing oven. The enclosure housed a MISTRAS® motorized X-Y raster scanner and contact transducer (Olympus® X2002). The Olympus® X2002 contact transducer is a continuous high-temperature delay line transducer with a center frequency of 2.25 MHz. In order to prevent the inside of the enclosure from reaching high temperatures, a sparge pipe inside the cooling enclosure was connected to a liquid nitrogen (LN2) tank outside of the oven via insulated hoses. The cooling system was automatically controlled by a temperature controller that was programmed to open a solenoid valve along the hose at 31 ℃ and close at 28 ℃ inside the cooling enclosure. When the solenoid valve was open, LN2 would flow from the LN2 tank and vaporize prior to reaching cooling enclosure. A U-shaped sparge pipe had holes drilled along its length to uniformly introduce cold nitrogen gas into the cooling enclosure. This prevented the motors from ever reaching the maximum desired operating temperature of 38 ℃. In the bottom of the enclosure, the tool plate was placed with the composite facing the outside of the enclosure, exposing it to the temperatures of the oven. The tool plate was 63.5 mm thick borosilicate glass, which was chosen for its low ultrasonic attenuation and moderate thermal conductivity. A thin layer of ultrasonic couplant was placed on the tool plate. The transducer sent and received ultrasonic waves through the tool plate into the composite. A MISTRAS® Remote UT System performed all wave generation, analog to digital conversion, and data acquisition and processing. The transducer was connected directly to the Remote UT System via a high-temperature BNC cable (CD International, RG-316). Polyimide insulated copper wire was used to connect the scanner to a 2-axis motor drive, which was connected to the Remote UT System. The motor drive and Remote UT System were located outside the industrial oven. A diagram of the ultrasonic system is shown in Figure 1. Figure 1: Diagram of ultrasonic in-situ defect detection system. In this study, a porosity gradient was introduced into the carbon fiber reinforced polymer (CFRP) composite through a misfit of the part and caul plate. A 24-ply quasi-isotropic ([0/90, ±45]12S) composite panel was laid up using Newport® AS4C-M/NB321 out-of-autoclave (OOA) plain weave (PW) prepreg (42% resin content, 195 g/m2). The first 16 plies were 203 mm × 203 mm. Ply drops were incorporated into the panel by decreasing the length of plies 17-24. The sizes of each ply are included in Table 1. All plies were centered along their length (x-axis) creating a trapezoidal type cross-section. Table 1: Ply sizes Plies Length (mm) Width (mm) 1-16 203 203 17-18 102 203 19-20 85 203 21-22 68 203 23-24 51 203 A 15-5 stainless steel caul plate (Size: 203 × 203 × 1.2 mm) was placed on the laminate. The composite and caul plate were vacuum bagged to the tool plate. Per the product datasheet, Newport 321 can be cured between 121 °C and 149 °C, depending on service temperature, with a hold for 90-120 minutes. Based on prior thermal testing of the cooling enclosure, the desired composite temperature cycle could be attained when the air temperature of the oven was ramped to 160 °C at a rate of 1.7 °C/min with a 3 hour hold. The extended hold was not necessary to cure the composite, but did allow for additional scans at the cure temperature during preliminary testing. The composite panel was under vacuum pressure for the entire cure cycle. Under vacuum, the caul plate deformed causing high and low pressure regions. The low-pressure regions formed high porosity in the composite part. The ultrasonic data collected showed that the inspection system was able to monitor the evolution of porosity within the composite throughout the cure cycle. Fifty scans of a 203 mm × 51 mm (8 in. × 2 in.) area of the composite were completed throughout the cure cycle. The scan speed was set to 43 mm/s in the x-direction and 36 mm/s in the y-direction, with a 1.0 mm/pixel resolution in both directions. Each scan took approximately five minutes to complete. Figure 2 shows C-scan amplitude data (top view) from one scan during the cure cycle. The color map indicates the maximum amplitude (%) measured with a time gate that contains reflections from the back surface (furthest from the transducer in contact with the caul plate) of the composite. Because porosity in the composite increases the ultrasonic attenuation in the composite part, a higher amplitude (red) indicates low porosity and a lower amplitude (blue) indicates high porosity. The regions where the caul plate was applying increased pressure (center and ends of the panel) resulted in reduced porosity, whereas the ply drop regions had reduced pressure and thus had higher porosity. Figure 2: Amplitude C-scan (top view) of OOA composite from one scan during the 160 °C temperature hold. Higher amplitude (red) indicates low porosity. Lower amplitude (blue) indicates high porosity. A B-scan is a two-dimensional image plotting the ultrasonic signals from a single y-position at every x-location of the composite panel. The travel time (μs) of the ultrasonic wave (representing the through-thickness location) is plotted along the y-axis, and the ultrasonic wave signal is represented as a contour map. Based on the B-scan data, the location of the defects with respect to the composite thickness was able to be determined. The ply drop regions had high porosity near the front (tool plate) surface of the composite (Figure 3). Figure 3: B-scan (cross-section view) of OOA composite from one scan during the 160 °C temperature hold. Using the data obtained from amplitude C-scans and B-scans throughout the cure cycle, the high and low porosity regions within the composite laminate were detected and localized with high spatial resolution. This paper will discuss the evolution of porosity content in the OOA composite during cure. OOA tests aided the transition of this system to an autoclave, which is the primary method of curing aerospace-grade thermoset composites.

Tyler B. Hudson↗

Single and Multi-Node Modeling of Direct, Submerged, and Self-Pressurization of A Cryogenic Propellant Tank Using Nodal Tools

The pressurization of cryogenic propellant tanks will always be an important process so long as cryogenic liquids are being considered as fuel sources or used for other in-space applications. Pressure control of the tank ullage is necessary for managing propellant flowrates to an engine or a receiver tank, and modeling of the process is used to predict the pressurant requirements and the amount of propellant boiloff. Direct ullage pressurization is the more traditional approach to tank pressurization, as the physics are straight-forward, and ample test (flight) data have been collected and analyzed over the past several decades. Submerged injection pressurization is an alternate method for tank pressurization and has been shown to reduce pressurant requirements, subcool the propellant, and reduce the risk of ullage collapse. Additionally, the pressurant gas entering the ullage is usually much colder when using the submerged pressurization approach, resulting in reduced propellant boiloff. These benefits are at the expense of vaporizing a small percentage of the propellent. Both tank pressurization methods are viable options for current and future space missions, and it is important to have the capability of analyzing the tank ullage conditions for both approaches. Our previous work has demonstrated the development of a Generalized Fluid System Simulation Program (GFSSP) model, which contains a thermodynamic equilibrium heat and mass transfer subroutine capable of effectively analyzing both direct and submerged pressurization systems [1-2]. This subroutine has most recently been enhanced to include the non-equilibrium effect of pressurant dissolution into the propellant. To date the ullage has always been represented as a single node, and although the simulated single-node temperatures have good comparison with the volume-averaged ullage temperatures computed from test data, the physics of the thermal stratification in the ullage were never captured, and adjustment factors in the model were required. The purpose of this paper is to introduce the development of a multi-node ullage model using GFSSP and to discuss the improvements of the simulated ullage temperature distribution and its resulting effects on ullage heat transfer processes. Test data from the Cryogenic Propellant Storage and Transfer Engineering Developmental Unit (CPST EDU) was used for model validation. For additional comparison, a Thermal Desktop (TD) model was also developed to analyze the CPST EDU direct ullage pressurization tests using both a single node and multi-node approach. The model includes the direct pressurant line, vent line, fill/drain line, and a TD FloCAD Compartment. The TD FloCAD Compartment is employed to represent the liquid and ullage as single volumes inside the tank, to include a liquid/vapor interface, and to generate network level objects such as lumps (analogous to nodes in GFSSP), paths, and ties between the fluid and thermal elements. An established heat load on the model tank was leveraged from a pre-existing higher-fidelity model correlated to CPST EDU test data.

pressurization↗

GES DISC Datalist Improves Earth Science Data Discoverability

At American Geophysical Union(AGU) 2016 Fall Meeting, Goddard Earth Sciences Data Information Services Center (GES DISC) unveiled a novel way to access data: Datalist. Currently, datalist is a collection of predefined data variables from one or more archived datasets, curated by our subject matter expert (SME). Our science support team has curated a predefined Hurricane Datalist and received very positive feedback from the user community. Datalist uses the same architecture our new website uses and have the same look and feel as other datasets on our web site. and also provides a one-stop shopping for data, metadata, citation, documentation, visualization and other available services. Since the last AGU Meeting, we have further developed a few new datalists corresponding to the Big Earth Data Initiative (BEDI) Societal Benefit Areas and A-Train data. We now have four datalists: Hurricane, Wind Energy, Greenhouse Gas and A-Train. We have also started working with our User Working Group members to create their favorite datalists and working with other DAAC to explore the possibility to include their products in our datalists that may also lead to a future of potential federated (cross-DAAC) datalists. Since our datalist prototype effort was a success, we are planning to make datalist operational. It's extremely important to have a common metadata model to support datalist, this will also be the foundation of federated datalist. We mapped our datalist metadata model to the unpublished UMM(Universal Metadata Model)-Var (Variable) (June version) and found that the UMM-var together with UMM-C (Collection) and possible UMM-S (Service) will meet our basic requirements. For example: Dataset shortname, and version are already specified in UMM-C, variable name, long name, units, dimensions are all specified in UMM-Var. UMM-Var also facilitates Science Keywords to allow tagging at variable level and Characteristics for optional variable characteristics. Measurements is useful for grouping of the variables and Set is promising to define datalist. And finally, the UMM-Service model to specify the available services for the variable will be very beneficial. In summary, UMM-Var, UMM-C and UMM-S are the basis of federated datalist and the development and deployment of datalist will contribute to the evolution of the UMM.

datalist↗

BioSentinel: Leading the Way for Deep Space CubeSat Missions

Flagship science missions are not alone in Deep Space thanks to BioSentinel, a 6U spacecraft launched on Artemis-1. BioSentinel is one of the longest operating CubeSats beyond cislunar space. The subsystems and COTS components of the BioSentinel bus are a template for future deep space missions, and the lessons learned from over a year of operations will enable improved performance for the next missions. BioSentinel achieved its unprecedented performance for an SLS secondary payload due to preparation, planning, and a robust design. Pre-launch antenna and interface testing with both DSN and ESA confirmed command and data pathways and allowed for operational flexibility in the critical early hours post-deployment. Mission Operations simulations prior to launch identified potential risks and primed operators to respond in flight, preparing the team to react quickly to successfully detumble the spacecraft and enter a power-positive state. The spacecraft would not have survived without the inclusion of the trailblazing 3D-printed composite cold gas propulsion system. The non-standard tank geometry enabled efficient use of the limited space available in the CubeSat, as well as the capability to detumble the spacecraft and manage momentum, while providing sufficient margin to execute potential delta-V maneuvers. The Iris radio has operated for over 18 months with no significant issues. Initial Iris performance estimates have been accurate throughout the mission. BioSentinel continues to collect data on thermal conditions and to validate our performance models with real-world knowledge. We have received exemplary support from our DSN partners. Following the conclusion of the primary science mission, the Linear Energy Transfer (LET) Spectrometer continued to collect solar and galactic radiation data from its location in heliocentric orbit. The free space dataset offered by the BioSentinel LET is a valuable source of data for model validation and future mission planning. As the spacecraft travels farther from Earth it is poised to provide longitudinally distributed measurements of solar particle events during solar maximum. The lessons learned from BioSentinel suggest key areas to enhance performance. The ability to upload modified flight software can increase the stability of memory management. Additional heaters in the propulsion system design have already proven successful on the Starling mission. Streamlining mission operations can reduce costs, increase data return, and better utilize DSN time. Enhancements such as these will facilitate reliable, long-duration deep space exploration using the proven BioSentinel 6U CubeSat bus.

BioSentinel↗

Analysis and design of a capsule landing system and surface vehicle control system for Mars exporation

The problems related to the design and control of a mobile planetary vehicle to implement a systematic plan for the exploration of Mars were investigated. Problem areas receiving attention include: vehicle configuration, control, dynamics, systems and propulsion; systems analysis; navigation, terrain modeling and path selection; and chemical analysis of specimens. The following specific tasks were studied: vehicle model design, mathematical modeling of dynamic vehicle, experimental vehicle dynamics, obstacle negotiation, electromechanical controls, collapsibility and deployment, construction of a wheel tester, wheel analysis, payload design, system design optimization, effect of design assumptions, accessory optimal design, on-board computer subsystem, laser range measurement, discrete obstacle detection, obstacle detection systems, terrain modeling, path selection system simulation and evaluation, gas chromatograph/mass spectrometer system concepts, chromatograph model evaluation and improvement and transport parameter evaluation.

Frederick, D. K.↗

Elastomeric Seal Performance after Terrestrial Ultraviolet Radiation Exposure

Ultraviolet radiation was evaluated to determine its negative effects on the performance of elastomeric gas pressure seals. The leak rates of the silicone elastomer S0383-70 O-ring test articles were used to quantify the degradation of the seals after exposure to vacuum-ultraviolet and/or middle-to-near-ultraviolet wavelength radiation. Three groups of seals were exposed in terrestrial facilities to 115-165 nm wavelength radiation, 230-500 nm wavelength radiation, or both spectrums, for an orbital spaceflight equivalent of 125 hours. The leak rates of the silicone elastomer S0383-70 seals were quantified and compared to samples that received no radiation. Each lot contained six samples and statistical t-tests were used to determine the separate and combined influences of exposure to the two wavelength ranges. A comparison of the mean leak rates of samples exposed to 115-165 nm wavelength radiation to the control specimens showed no difference, suggesting that spectrum was not damaging. The 230-500 nm wavelength appeared to be damaging, as the mean leak rates of the specimens exposed to that range of wavelengths, and those exposed to the combined 115-165 nm and 230-500 nm spectrums, were significantly different from the leak rates of the control specimens. Most importantly, the test articles exposed to both wavelength spectrums exhibited mean leak rates two orders of magnitude larger than any other exposed specimens, which suggested that both wavelength spectrums are important when simulating the orbital environment.

leakage↗

Analysis and design of a capsule landing system and surface vehicle control system for Mars exploration

Investigation of problems related to the design and control of a mobile planetary vehicle to implement a systematic plan for the exploration of Mars has been undertaken. Problem areas receiving attention include: vehicle configuration, control, dynamics, systems and propulsion; systems analysis; terrain modeling and path selection; and chemical analysis of specimens. The following specific tasks have been under study: vehicle model design, mathematical modeling of a dynamic vehicle, experimental vehicle dynamics, obstacle negotiation, electromechanical controls, collapsibility and deployment, construction of a wheel tester, wheel analysis, payload design, system design optimization, effect of design assumptions, accessory optimal design, on-board computer sybsystem, laser range measurement, discrete obstacle detection, obstacle detection systems, terrain modeling, path selection system simulation and evaluation, gas chromatograph/mass spectrometer system concepts, chromatograph model evaluation and improvement.

Frederick, D. K.↗

Laser system for natural gas detection. Phase 1: Laboratory feasibility studies

This project demonstrated the feasibility of using laser remote sensing technology as a tool for leak survey work in natural gas distribution systems. A laboratory device was assembled using a pair of helium neon (HeNe) lasers to measure methane. One HeNe laser emits radiation at a wavelength of 3.3922 micrometers, which corresponds to a strong absorption feature of methane, while the other emits radiation at a wavelength of 3.3911 micrometers, which corresponds to a weak absorption by methane. As a particular area is scanned for leaks, the laser is pointed at convenient topographic targets within its operating range, about 25 m. A portion of the backscattered radiation is collected by a receiver and focused onto an indium antimonide (InSb) photodetector, cooled to 77K. Methane concentrations were determined from the differential absorption at the two wavelengths for the backscattered radiation.

Grant, W. B.↗

Total immersion crystal growth

Crystals of wide band gap materials are produced by positioning a holder receiving a seed crystal at the interface between a body of molten wide band gap material and an overlying layer of temperature-controlled, encapsulating liquid. The temperature of the layer decreases from the crystallization temperature of the crystal at the interface with the melt to a substantially lower temperature at which formation of crystal defects does not occur, suitably a temperature of 200 to 600 C. After initiation of crystal growth, the leading edge of the crystal is pulled through the layer until the leading edge of the crystal enters the ambient gas headspace which may also be temperature controlled. The length of the column of liquid encapsulant may exceed the length of the crystal such that the leading edge and trailing edge of the crystal are both simultaneously with the column of the crystal. The crystal can be pulled vertically by means of a pulling-rotation assembly or horizontally by means of a low-angle withdrawal mechanism.

Morrison, Andrew D.↗

Ozone and temperature trends

An update of the extensive reviews of the state of knowledge of measured ozone trends published in the Report of the International Ozone Trends Panel is presented. The update contains a review of progress since these reports, including reviewing of the ozone records, in most cases through March 1991. Also included are some new, unpublished reanalyses of these records including a complete reevaluation of 29 stations located in the former Soviet Union. The major new advance in knowledge of the measured ozone trend is the existence of independently calibrated satellite data records from the Total Ozone Mapping Spectrometer (TOMS) and Stratospheric Aerosol and Gas Experiment (SAG) instruments. These confirm many of the findings, originally derived from the Dobson record, concerning northern mid-latitude changes in ozone. We now have results from several instruments, whereas the previously reported changes were dependent on the calibration of a single instrument. This update will compare the ozone records from many different instruments to determine whether or not they provide a consistent picture of the ozone change that has occurred in the atmosphere. The update also briefly considers the problem of stratospheric temperature change. As in previous reports, this problem received significantly less attention, and the report is not nearly as complete. This area needs more attention in the future.

Stolarski, Richard S.↗

Retrieval Algorithm for the Column CO2 Mixing Ratio from Pulsed Multi-Wavelength Lidar Measurements

The retrieval algorithm for the column mixing ratio of CO2 from the measurements of a pulsed multi-wavelength integrated path differential absorption (IPDA) lidar is described. The lidar samples the shape of the 1572.33 nm CO2 absorption line at 15 or 30 wavelengths. The algorithm uses a least-squares fit between the CO2 line shape computed from a layered 10 atmosphere model to that sampled by the lidar. In addition to the column average CO2 dry air mole fraction (XCO2), several other parameters are also solved simultaneously from the fit. These include the Doppler shift in the received laser signal wavelengths, the product of the surface reflectivity and atmospheric transmission and a linear trend in the lidar receiver’s spectral response. The algorithm can also be used to solve for the average water vapor mixing ratio, which causes a secondary absorption in the wings of the CO2 absorption line under high humidity conditions. The least-squares fit is linearized about the 15 expected XCO2 value which allows the use of a standard linear least-squares fitting method and software tools. The standard deviation of the retrieved XCO2 is obtained from covariance matrix of the fit. An averaging kernel is defined similarly to that used for passive trace-gas sounding. Examples are presented of using the algorithm to retrieve XCO2 from the measurements from NASA Goddard’s airborne CO2 Sounder lidar made at a constant altitude and during spiral-down maneuvers.

Xiaoli Sun↗

Frequency and Phase-lock Control of a 3 THz Quantum Cascade Laser

We have locked the frequency of a 3 THz quantum cascade laser (QCL) to that of a far-infrared gas laser with a tunable microwave offset frequency. The locked QCL line shape is essentially Gaussian, with linewidths of 65 and 141 kHz at the -3 and -10 dB levels, respectively. The lock condition can be maintained indefinitely, without requiring temperature or bias current regulation of the QCL other than that provided by the lock error signal. The result demonstrates that a terahertz QCL can be frequency controlled with l-part-in-lO(exp 8) accuracy, which is a factor of 100 better than that needed for a local oscillator in a heterodyne receiver for atmospheric and astronomic spectroscopy.

Betz, A. L.↗

Wear and Reactivity Studies of Melt infiltrated Ceramic Matrix Composite

As interest grows in the use of ceramic matrix composites (CMCs) for critical gas turbine engine components, the effects of the CMCs interaction with the adjoining structure needs to be understood. A series of CMC/material couples were wear tested in a custom elevated temperature test rig and tested as diffusion couples, to identify interactions. Specifically, melt infiltrated silicon carbide/silicon carbide (MI SiC/SiC) CMC was tested in combination with a nickel-based super alloy, Waspaloy, a thermal barrier coating, Yttria Stabilized Zirconia (YSZ), and a monolithic ceramic, silicon nitride (Si3N4). To make the tests more representative of actual hardware, the surface of the CMC was kept in the as-received state (not machined) with the full surface features/roughness present. Test results include: scanning electron microscope characterization of the surfaces, micro-structural characterization, and microprobe analysis.

Jarmon, David C.↗

The atmosphere of Neptune - An analysis of radio occultation data acquired with Voyager 2

The vertical structure of Neptune's atmosphere is studied on the basis of recordings of the tracking signals received from Voyager 2 during its occultation by Neptune. The measurements began at a planetographic latitude of 62 deg north and ended near 45 deg south, and cover an altitude interval of about 5000 km. The 1-bar isobaric surface has equatorial and polar radii of 24,766 +/-15 km and 24,342 +/-30 km, respectively, and a corresponding oblateness of 0.0171 +/-0.0014. At this pressure, the temperature was 72 +/-2 K. The tropopause was detected approximately 40 km above the 1-bar level at a pressure of about 100 mbar. A comparison with IR observations indicates that the gas at the tropopause consists of 78-84-percent hydrogen by number density with the rest being mostly helium. The temperature in this region was 52 +/-2 K.

Lindal, Gunnar F.↗

A Three-Dimensional Receiver Operator Characteristic Surface Diagnostic Metric

Receiver Operator Characteristic (ROC) curves are commonly applied as metrics for quantifying the performance of binary fault detection systems. An ROC curve provides a visual representation of a detection system s True Positive Rate versus False Positive Rate sensitivity as the detection threshold is varied. The area under the curve provides a measure of fault detection performance independent of the applied detection threshold. While the standard ROC curve is well suited for quantifying binary fault detection performance, it is not suitable for quantifying the classification performance of multi-fault classification problems. Furthermore, it does not provide a measure of diagnostic latency. To address these shortcomings, a novel three-dimensional receiver operator characteristic (3D ROC) surface metric has been developed. This is done by generating and applying two separate curves: the standard ROC curve reflecting fault detection performance, and a second curve reflecting fault classification performance. A third dimension, diagnostic latency, is added giving rise to 3D ROC surfaces. Applying numerical integration techniques, the volumes under and between the surfaces are calculated to produce metrics of the diagnostic system s detection and classification performance. This paper will describe the 3D ROC surface metric in detail, and present an example of its application for quantifying the performance of aircraft engine gas path diagnostic methods. Metric limitations and potential enhancements are also discussed

Simon, Donald L.↗