Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GLOVEBOXES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Assembly of Arbitrary Designer Heterostructures with Atomically Clean Interfaces

Van der Waals heterostructures are an excellent platform for studying intriguing interface phenomena, such as moiré and proximity effects. Many of these phenomena occurring in such heterostructures' interfaces and surfaces have so far been hampered because of their high sensitivity to disorder and interface contamination. Here, it reports a dry polymer-based assembly technique to fabricate arbitrary designer van der Waals heterostructures with atomically clean surfaces. The key features of the suspended dry pick-up and flip-over assembly technique are: 1) the heterostructure surface never comes into contact with polymers, 2) the assemble is entirely solvent-free, 3) it is entirely performed in a glovebox, and 4) it only requires temperatures below 130 °C. By performing ambient atomic force microscopy and atomically-resolved scanning tunneling microscopy on example heterostructures, it demonstrates the fabrication of air-sensitive heterostructures with ultra-clean interfaces and surfaces. It envisions that, due to the avoidance of polymer melting, this technique is potentially compatible with heterostructure assembly under ultra-high vacuum conditions, which promises ultimate heterostructure quality.

2D materials↗

Evaluation of preservation protocols for oxygen-sensitive minerals within laminated aquatic sediments

Laminated sediments can record seasonal changes in sedimentation of material from anoxic waters, including minerals of the redox-sensitive elements Fe, Mn, and S that form under varying oxygen levels, mineral saturation conditions, and from microbial metabolism. However, preserving the oxygen-sensitive minerals for identification is challenging when preservation of the spatial arrangement of laminae is also required. In this study, we compare methods for embedding sedimentary materials from anoxic waters and sediments from Brownie Lake, Minnesota, USA for analysis of the speciation for Fe, Mn, and S using synchrotron-based X-ray absorption near edge spectroscopy (XANES). We found that acetone dehydration and resin replacement in a 100% N 2 glovebox successfully preserved the speciation of Fe and Mn minerals within laminated sediments. However, acetone removed some sulfur species from sediments, and epoxies contained sulfur species, which challenged identification of native sulfur species. Results from this study will aid researchers who are interested in spatial analysis of oxygen sensitive sediments, soils, or microbial mats in choosing a preservation method.

58 GEOSCIENCES↗

Calibration curves for commercial copper and aluminum alloys using handheld laser-induced breakdown spectroscopy

Handheld laser-induced breakdown spectroscopy (HH LIBS) was used to study the elemental composition of four copper alloys and four aluminum alloys to produce calibration curves. The HH LIBS instrument used is a SciAps Z-500, commercially available, that contains a class-1 solid-state laser with an output wavelength of 1532 nm, a laser energy of 5 mJ/pulse, and a pulse duration of 5 ns. Test samples were solid specimens comprising of copper and aluminum alloys and data were collected from the samples’ surface at three different locations, employing a 12-point-grid pattern for each data set. All three data sets of the spectra were averaged, and the intensity, corrected by subtraction of background, was used to produce the elemental calibration curves. Calibration curves are presented for the matrix elements, copper and aluminum, as well as several minor elements. The surface damage produced by the laser was examined by microscopy. The alloys were tested in air and in a glovebox to evaluate the instrument’s ability to identify the constituents within materials under different environmental conditions. The main objective of using this HH LIBS technology is to determine its capability to fingerprint the presence of certain elements related to subpercent level within materials in real time and in-situ, as a starting point for undertaking future complex material characterization work.

36 MATERIALS SCIENCE↗

Changing the Rules of the Game: Used Fuel Studies Outside of a Remote Handling Facility

Recent advances in micro-fabrication tools like the FEI Helios NanoLab 660 dual Focused Ion Beam (FIB) and Scanning Electron Microscope (SEM) now make it possible to easily and reliably prepare micron (or smaller) specimens for analyses or further experimentation. Pacific Northwest National Laboratory (PNNL) has leveraged this capability at the Category II Nuclear Facility, the Radiochemical Processing Laboratory, to facilitate nuclear materials analysis and experimentation of used nuclear fuel. Micron-scale specimens of un-irradiated UO2 fuel pellets of various enrichments from depleted to 4.95% enriched, relative to 235U, were prepared at PNNL and shipped to the University of Missouri’s Research Reactor (MURR) for irradiation. Prior to shipping, samples were attached to commercially available Transmission Electron Microscopy half-grids via ion deposition, which were then housed in specially designed aluminum sample holders approved for use at the reactor facility. This minimized handling and preparation requirements prior to materials analysis after irradiation. Samples were irradiated to a burnup equivalent of 8 – 3,700 MWd/MTU. Additionally, by reducing the size of the specimens, and therefore their emitted radiation dose, the required cooling time after irradiation and prior to analysis was greatly diminished, and handling of these samples could proceed outside of a hot cell facility. Results from these experiments provided insight into the initial production of noble metal phase particles in used nuclear fuel at extremely low burnup levels. Some incompatibility with the container was observed at higher burnup. Micro-scale irradiation experiments were performed at roughly 1/7th of the time, effort and expense a similar bulk-scale study requiring a shielded hot cell facility would require. Conducting nuclear materials analysis at the micron-scale holds the promise of enhancing collaboration and material accessibility to the broader research community, improving accessibility to cutting edge research tools by the nuclear materials science community, lowering the risk to the scientist by reducing radiation dose and exposure, reducing facility and research costs associated with the requirement to conduct nuclear materials science within glovebox or remote handling facilities, and minimizing waste.

Schwantes, Jon M.↗

Molar Absorptivities of U(VI), U(IV), and Pu(III) in Nitric Acid Solutions of Various Concentrations Relevant to Developing Nuclear Fuel Recycling Flowsheets

Testing of a co-decontamination (CoDCon) tributyl phosphate (TBP) based solvent extraction flowsheet is being performed to optimize conditions for achieving a target U/Pu ratio in the Pu-containing product. The flowsheet is designed to directly produce a mixture of U and Pu with a U/Pu mass ratio of 7/3. The system is monitored in real time using optical spectroscopy, which allows for control of the U/Pu ratio in the aqueous U/Pu nitrate product. On-line spectrophotometric monitoring of the aqueous stream at the reductive stripping step involves determination of U(VI), U(IV) and Pu(III) concentrations and relies on molar absorptivities of these species in nitric acid at a number of wavelengths corresponding to their peaks’ maxima. The magnitudes of these molar absorptivities are a sensitive function of nitric acid concentration and have to be determined as precisely as possible using an off-line spectrophotometry under well controlled conditions. This step (called training set acquisition) is typically performed not in a high contamination area of radiological glovebox where flow-through cells and other on-line equipment are installed but in a less aggressive environment of a radiological fume hood with much better control of stock solutions quality, dilution factors, optical absorbance scale calibration, etc. This is followed by the calibration transfer between the off-line instrument and the instrument deployed during extraction and stripping runs. This paper reports values of molar absorptivities of U(VI), U(IV), and Pu(III) in nitric acid solution of 0.5 M to 4 M concentration and compares them with available technical literature data. Results of off-line spectrophotometric analysis of selected aqueous grab samples from one of CoDCon runs show satisfactory agreement with total uranium and plutonium concentrations determined in the same samples by ICP-MS.

Sinkov, Sergey I.↗

Apollo Next Generation Sample Analysis (ANGSA): an Apollo Participating Scientist Program to Prepare the Lunar Sample Community for Artemis

As a first step in preparing for the return of samples from the Moon by the Artemis Program, NASA initiated the Apollo Next Generation Sample Analysis Program (ANGSA). ANGSA was designed to function as a low-cost sample return mission and involved the curation and analysis of samples previously returned by the Apollo 17 mission that remained unopened or stored under unique conditions for 50 years. These samples include the lower portion of a double drive tube previously sealed on the lunar surface, the upper portion of that drive tube that had remained unopened, and a variety of Apollo 17 samples that had remained stored at -27 °C for approximately 50 years. ANGSA constitutes the first preliminary examination phase of a lunar “sample return mission” in over 50 years. It also mimics that same phase of an Artemis surface exploration mission, its design included placing samples within the context of local and regional geology through new orbital observations collected since Apollo and additional new “boots-on-the-ground” observations, data synthesis, and interpretations provided by Apollo 17 astronaut Harrison Schmitt. ANGSA used new curation techniques to prepare, document, and allocate these new lunar samples, developed new tools to open and extract gases from their containers, and applied new analytical instrumentation previously unavailable during the Apollo Program to reveal new information about these samples. Most of the 90 scientists, engineers, and curators involved in this mission were not alive during the Apollo Program, and it had been 30 years since the last Apollo core sample was processed in the Apollo curation facility at NASA JSC. There are many firsts associated with ANGSA that have direct relevance to Artemis. ANGSA is the first to open a core sample previously sealed on the surface of the Moon, the first to extract and analyze lunar gases collected in situ, the first to examine a core that penetrated a lunar landslide deposit, and the first to process pristine Apollo samples in a glovebox at -20 °C. All the ANGSA activities have helped to prepare the Artemis generation for what is to come. The timing of this program, the composition of the team, and the preservation of unopened Apollo samples facilitated this generational handoff from Apollo to Artemis that sets up Artemis and the lunar sample science community for additional successes.

79 ASTRONOMY AND ASTROPHYSICS↗

Bronze Alloy Development for Zinc Vapor Capture

After gamma-emitting 65 Zinc was detected in a vacuum pumping system contained in a tritium glovebox, a series of experiments were undertaken to develop a method and material to trap zinc vapors in an area that is more suitable for preventing dose to workers. In this study, bronze alloys with 0–30% tin were prepared using a powder metallurgical process and exposed to three levels of zinc vapors. Furthermore, all of the alloys demonstrated acceptable zinc gettering capacity; however, low tin content bronzes are considered for further testing.

36 MATERIALS SCIENCE↗

Effectiveness of Bronze as a Zinc Getter After Being Subjected to Simulated Exposures

We report that gamma-emitting zinc-65 was detected in piping contained in a tritium glovebox after a vacuum thermal process. This contaminate was created during irradiation of components in a nuclear reactor and was borne of natural zinc. The Tritium Extraction Facility prefers to capture the zinc in a high radiation area to minimize potential dose to the worker and to reduce the likelihood of spreading contamination to other areas of the facility. Previous efforts have shown that bronze is an excellent candidate material to act as a zinc getter in the as-fabricated condition. In reality, the extraction process may contain moisture and hydrogen which could cause oxidation or reduction of the surfaces of the zinc getters. A series of experiments was conducted to determine the efficacy of the zinc getters after oxidation and reduction exposures. Lastly, it was determined that the bronze coupons were moderately effective in most of the oxidized conditions and in all the oxidized and reduced conditions.

36 MATERIALS SCIENCE↗

Impact of nitrate on the redox chemistry and solubility of Tc(IV) in alkaline, dilute to concentrated aqueous NaCl solutions

Here, the impact of nitrate on the redox behaviour and solubility of 99 Tc(IV) was investigated in 0.1–5.0 M NaCl–NaNO 3 –NaOH solutions with 0.1 M ≤ [NO 3 – ] ≤ 1.0 M and 8.5 ≤ pH m ≤ 14.5 (with pH m = –log [H + ]) in the presence or absence of reducing agents (as Fe powder, Na 2 S 2 O 4 , Sn(II)). The evolution of the redox conditions as a function of time (for t ≤ 450 days) was investigated: (i) in the absence of technetium (inactive samples), (ii) in the presence of 99 Tc(IV) (added as 1–2 mg of TcO 2 ∙0.6H 2 O(am)), and (iii) in the presence of 137 Cs(I) (and absence of 99 Tc). All experiments were conducted in an Ar-glovebox (O 2 < 1 ppm) at T = (22 ± 2) °C. An improved understanding of Tc redox processes in nitrate-rich alkaline solutions is relevant to predict Tc behaviour in specific nuclear waste disposal scenarios and a topic of fundamental scientific interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of a Ag/Ag 2 S reference electrode with long-term stability for electrochemistry in ionic liquids

We report on a reference electrode designed for use in ionic liquids, based on a silver wire coated with silver sulfide. The reference electrode potential is determined by the concentrations of Ag + and S 2- , which are established by the solubility of the Ag 2 S coating on the Ag wire. While potential shifts of >100 mV during an experiment have been reported when using silver or platinum wire quasi-reference electrodes, the reference electrode reported here provides a stable potential over several months of experimental use. Additionally, our reference electrode can be prepared and used in a normal air atmosphere, and does not need to be assembled and used in a glovebox, or protected from light. In conclusion, the reference electrode has been characterized by voltammetry measurements of ferrocene and cobaltocenium hexafluorophosphate, and was found to slowly drift to more positive potentials at a rate of <1 mV/day for five of the six ionic liquids investigated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The influence of LiH and TiH 2 on hydrogen storage in MgB 2 II. XPS study of surface and near-surface phenomena

We report that Mg(BH 4 ) 2 is a promising solid-state hydrogen storage material, releasing 14.9 wt% hydrogen upon conversion to MgB 2 . The rehydrogenation of MgB 2 is particularly challenging, requiring prolonged exposure to high pressures of hydrogen at high temperature. Here we report an XPS study probing the influence of LiH and TiH 2 on the hydrogen storage properties of MgB 2 in the surface and near-surface regions, as a complementary investigation to a preceding study of the bulk properties. Surface and near-surface properties are important considerations for nanoscale and bulk hydrogen storage materials. If there are reactions occurring at the surface that modify the chemical composition in the near-surface region, species diffusion can alter the chemical composition even deep into the bulk of the material. For LiH/MgB 2 , metastable LiH–B and LiH–Mg species are produced that are more reactive than Bulk MgB 2 . With prolonged glovebox storage, the LiH/MgB 2 material shows increased reactivity towards O and C and enriched levels of Li and B in the near-surface region. In addition, Li induces the growth of Li 2 CO 3 in the surface and near surface regions. Exposing LiH/MgB 2 to hydrogen at 700 bar and 280 °C for 24 h produces borohydride at a temperature 100 °C below the threshold for bulk MgB 2 hydrogenation. In a specifically surface process with macroscopic implications, the hydrogenation conditions also cause Li 2 CO 3 to react with boron hydroxide in the sample to form a Li-deficient glassy lithium borate melt at the interfaces of the particles, bonding them together. Subsequent heating to 380 °C dehydrogenates the borohydride and eliminates the Li-deficient glassy lithium borate. The LiH/MgB 2 material is not reversible because desorption does not lead back to LiH/MgB 2 , but rather to elemental B and Mg metal in the near-surface region. In contrast to LiH, TiH 2 does not react with MgB 2 , despite the favorable thermodynamics for destabilization via TiB 2 formation. Furthermore, high pressure hydrogenation yields only unreacted TiH 2 and MgB 2 in the surface and near-surface regions. Thus, added TiH 2 provides no benefit to MgB 2 hydrogenation, in agreement with the findings of the preceding bulk study.

08 HYDROGEN↗

Novel use of a hand-held laser induced breakdown spectroscopy instrument to monitor hydride corrosion in uranium

With a compact hand-held laser-induced breakdown spectroscopy (LIBS) instrument, studies were performed on specimens of uranium charged with controlled hydrogen concentrations for a qualitative evaluation of hydride corrosion. Four samples of depleted uranium with two different starting microstructures (cast and rolled) were used for this study. The hydrogen charged samples (rolled 1.8 wppm H and cast 14 wppm H by weight) are representative of the pre-corrosion states with hydrides distributed throughout the bulk. In-depth LIBS measurements were carried out, after the thick surface corrosion layer was removed, by applying 100 laser pulses from sample surface into the bulk on five different sample locations. Three additional areas on each sample were investigated by laser ablation using a 12-point grid approach. The atomic emission signals of elemental uranium, carbon, hydrogen, and oxygen were identified and analyzed. All four samples showed similar uranium and carbon concentrations, as expected. Hydrogen content was consistent with each sample's specification, such that the hydrogen charged samples exhibited higher hydrogen concentration than their references. Both specimens charged with hydrogen showed elevated oxygen content as well, due to rapid oxidation of uranium and uranium hydrides. The oxidation process was facilitated by the laser ablation and plasma plume's high temperature effects on the sample combined with the glovebox environment. The uranium surface damage produced by laser ablation was quantitatively evaluated by optical microscopy.

36 MATERIALS SCIENCE↗

Uranium corrosion characterization by handheld laser-induced breakdown spectroscopy

In this study, a commercial-off-the-shelf handheld laser-induced breakdown spectroscopy system was modified, calibrated and tested for discrimination between uranium oxide and uranium hydride when assessing uranium corrosion products. Operating parameters, system modifications, and onboard data analysis were developed to accomplish the analytical task. This work represents the first laser-induced breakdown spectroscopy analysis of bulk uranium hydride, a pyrophoric material, within an inert glovebox. Finally, the work shown here illustrates a rapid identification technique for uranium corrosion types from pure UO 2 or U 3 O 8 to pure UH 3 .

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Synthesis of metal chloride films: Influence of growth conditions on crystallinity

This paper presents the first deposition of metal chlorides by RF magnetron sputtering. By integrating the sputter chamber with an Ar-filled glovebox, films of hygroscopic chlorides can be synthesized and studied. The structure, composition, and morphology of FeCl 3 and FeCl 2 films were investigated as a function of deposition rate. In FeCl 3 films, the deposition rate has a large impact on the crystallinity of as-deposited films regardless of the substrate used. At high deposition rates, 24 Å/s, FeCl 3 films are crystalline with a preferred orientation along the 003-plane, while at low deposition rates, 0.5 Å/s, no crystalline peaks are observed for FeCl 3 . In FeCl 2 , the highest deposition rate achieved in this study was 0.2 Å/s which yields films with no crystalline peaks; therefore, Raman spectroscopy was used to confirm the presence of FeCl 2 . Here, the deposition of iron chlorides by RF magnetron sputtering opens the way for the study of thin film metal halides to understand their growth, magnetic and electronic properties, and understand ion transport through their layered structures.

36 MATERIALS SCIENCE↗

Understanding the Reactions Between Fe and Se Binary Diffusion Couples

Spurred by recent discoveries of high-temperature superconductivity in Fe-Se based materials, the magnetic, electronic, and catalytic properties of iron-chalcogenides have drawn significant attention. Furthermore, much remains to be understood about the sequence of phase formation in these systems. In this work, we shed light on this issue by preparing a series of binary Fe-Se ultrathin diffusion couples via designed thin film precursors and investigating their structural evolution as a function of composition and annealing temperature. Two previously unreported Fe-Se phases crystallized during the deposition process on a nominally room-temperature Si substrate in the 27-33% and 37-47% Fe (atomic percent) composition regimes. Both phases completely decompose after annealing to 200°C in a nitrogen glovebox. At higher temperatures, the sequence of phase formation is governed by Se loss in the annealing process, consistent with what would be expected from the phase diagram. Films rich in Fe (53-59% Fe) crystalized during deposition as β-FeSe (P4/nmm) with preferred c-axis orientation to the amorphous SiO 2 substrate surface, providing a means to non-epitaxial self-assembly of crystallographically aligned, iron-rich β-FeSe for future research. Our findings suggest the crystallization of binary Fe-Se compounds at room temperature via near diffusionless transformations should be a significant consideration in future attempts to prepare metastable ternary and higher order compounds containing Fe and Se.

36 MATERIALS SCIENCE↗

UV–Vis–NIR Reflectance Spectroscopy and Chemometrics for Monitoring Pu Directly on an Ion Exchange Column

Here, we present a fiber-optic UV–vis–NIR reflectance spectroscopy method for direct, noninvasive monitoring of Pu(IV) in a glass ion exchange column during dynamic loading and elution in a glovebox. A movable probe enables spatially resolved spectral acquisition along the column axis, capturing distinct features associated with Pu(IV) nitrate complexes during loading and free ions during elution. Principal component analysis was applied to extract the dominant spectral variance and resolve relative concentration profiles without requiring precise knowledge of optical penetration depth or species identity. This in situ approach reveals spatial gradients and speciation dynamics in real time, which provides actionable insight into Pu(IV) ion migration, resin saturation, and breakthrough behavior under evolving flow conditions. The method offers a practical, fiber-compatible strategy to monitor glass column–based separations for Pu and other lanthanides or actinides and to characterize metal–resin interactions in flow-through systems.

actinide↗

Ion-Assisted Ligand Exchange for Efficient and Stable Inverted FAPbI 3 Quantum Dot Solar Cells

Perovskite quantum dot (QD) has emerged as a promising material for photovoltaics with its superior stability compared to their three-dimensional bulk counterparts, owing to its thermodynamically stabilized photoactive phase. However, ligand management on perovskite QD surfaces is extremely difficult due to the ionic nature of the perovskite lattice, which often leads to either incomplete removal of the native insulating ligands or formation of trap states during the ligand-exchange process, greatly hampering the photovoltaic performances. In this work, we report an ion-assisted ligand-exchange method for FAPbI 3 QDs using AOAc (A = formamidinium (FA + ), guanidinium (GA + ), and phenethylammonium (PEA + ), OAc = acetate), with the A + and OAC - ions promoting the removal of native long-chain insulating ligands. Further, the more complete ligand exchange results in dense and well-oriented packing of QDs, together with the enhancement of electronic coupling and charge transport across QDs. In addition, the A + and OAC - ions can fill the surface A-/X-site vacancies, respectively, reducing the QD surface trap state density and hence suppressing charge recombination and iodide migration. The p-i-n inverted QD solar cells fabricated with this ligand-exchange method exhibit significant enhancement in shortcircuit current density (J SC ), reaching a PCE of 10.13%. Moreover, unencapsulated devices show impressive stabilities of more than 7300 h (10 months) storage time in a N 2 -filled glovebox.

36 MATERIALS SCIENCE↗