Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GHZ RANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

DSN Radio Astronomy Spectrometer

The Deep Space Network (DSN) enables NASA to communicate with its deep space spacecraft. By virtue of its large antennas, the DSN can be used as a powerful instrument for radio astronomy. In particular, Deep Space Station (DSS) 43, the 70 m antenna at the Canberra Deep Space Communications Complex (CDSCC) has a K-band radio astronomy system covering a 10 GHz bandwidth at 17 to 27 GHz. This spectral range covers a number of atomic and molecular lines, produced in a rich variety of interstellar gas conditions. A new high-resolution spectrometer was deployed at CDSCC in November 2019 and connected to the K-band downconverter. The system has two different firmware modes: 1) Using a 65k-pt FFT to provide 32,768 spectral channels at ~30.5 kHz (0.45 km/s velocity resolution) and 2) Using a 16k-pt polyphase filterbank (PFB) to provide 8,192 spectral channels with ~122 kHz resolution (1.8 km/s velocity resolution). Previous work extensively described the spectrometer system. In this paper we present added functionality and updates to the commissioned spectrometer. The changes include developments in system timing, metadata, firmware and data products.

Bradford, Brian↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗

A segmented mirror antenna for radiometers

An antenna is designed for the radiometer application of the planned NASA Earth Science Geostationary Platforms in the 1990's. The antenna consists of two parts: a regular parabolic dish of 5 meters in diameter which converts the radiation from feeds into a collimated beam, and a movable mirror that redirects the beam to a prescribed scan direction. The mirror is composed of 28 segmented planar conducting plates, mostly one square meter in size. The secondary pattern of the antenna was analyzed based on a physical optics analysis. For frequencies between 50 and 230 GHz, and for a scan range of + or -8 deg (270 beamwidths scan at 230 GHz), the worst calculated beam efficiency is 95 percent. To cover such a wide frequency and scan range, each of the 28 plates is individually controlled for a tilting less than 4 deg, and for a sliding less than 0.5 cm. The sliding is done at discrete steps. At 230 GHz, a step size of 2 mil is sufficient. The plate positions must be reset for each frequency and for each scan direction. Once the position is set, the frequency bandwidth of the antenna is very narrow.

Lee, S. W.↗

A method for modeling discontinuities in a microwave coaxial transmission line

A method for modeling discontinuities in a coaxial transmission line is presented. The methodology involves the use of a nonlinear least-squares fit program to optimize the fit between theoretical data (from the model) and experimental data. When this method was applied to modeling discontinuities in a slightly damaged Galileo spacecraft S-band (2.295-GHz) antenna cable, excellent agreement between theory and experiment was obtained over a frequency range of 1.70-2.85 GHz. The same technique can be applied for diagnostics and locating unknown discontinuities in other types of microwave transmission lines, such as rectangular, circular, and beam waveguides.

Otoshi, T. Y.↗

Feasibility Study of Millimeter Wave Radars For Safeguards Applications

Containment and surveillance are fundamental measures in nuclear safeguards. Techniques such as video surveillance and laser curtain for containment provide effective monitoring in areas where maintaining continuity of knowledge is required. These systems, however, can be susceptible to loss of monitoring capabilities under certain environmental conditions such as poor visibility (i.e. low light conditions, smoke, fog, etc.) or extended power loss past the duration that the backup power system is designed for. Brookhaven National Laboratory has been investigating the feasibility of millimeter waves (mmWave) as a new perimeter seal in which radio frequency waves in the range of 60-64 GHz are used to detect and monitor objects of interest. Signals in this frequency range are not susceptible to environmental conditions. For proof-of-concept tests, mmWave sensors from Texas Instruments (TI), specificallyIWR6843, are used in a test bed at BNL's Waste Management facility to simulate the operations at nuclear facilities. The unique design of TI mmWave sensors requires less memory and power consumption compared to counterpart systems. These devices are capable of exporting 3D point-cloud data, which is visualized graphically and compared to videos recorded at the same time to validate the performance of the mmWave sensor. A set of experiments were planned to test the feasibility of the mmWave in this application, including monitoring static containers in a storage area and detecting intrusions at the boundaries of the area. In addition, the experiments also identify potential blind spots relative to sensor position and utilize multiple operating sensors simultaneously to reduce or eliminate such blind spots. The optimal positioning of multiple sensors was determined for the experimental room configuration. In this paper, we will discuss the details of this novel perimeter sealing concept and present the test results.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Pressure broadening of ClO by N2 and O2 near 204 and 649 GHz and new frequency measurements between 632 and 725 GHz

The N2 and O2 pressure broadening of the ClO transitions near 204 and 649 GHz have been measured between 200 and 300 K. Oxygen broadening has been measured for the transitions near 278 GHz. The accuracy of the derived air broadening is comparable to that for the air broadening of stable species and is estimated to be within approximately 3% over the entire temperature range. These transitions are currently being used for satellite, balloon, and ground based monitoring of atmospheric ClO, respectively. Some new frequency measurements are reported in the 632 - 725 GHz range. These are in good agreement with previous measurements and predictions.

Oh, J. J.↗

Millimeter- and submillimeter-wave surveys of Orion A emission lines in the ranges 200.7-202.3, 203.7-205.3, and 330-360 GHz

A continuous spectral line survey of the Orion A position from 330.5 to 360.1 GHz was carried out. This survey covers nearly the entire 870 micron atmospheric window accessible from ground-based observations. Approximately 160 distinct spectral features composed of about 180 lines were detected, 29 of which could not be readily identified. In addition, Orion A from 200.7 to 202.3 GHz and from 203.7 to 205.3 GHz and 42 distinct new spectral lines were detected, including four that are unidentified at present. These data sets are the first thorough survey results in these spectral regions. The new interstellar lines in the survey bands are tabulated and displayed graphically. Moreover, the data are being made available to the Astronomical Data Center at the Goddard Space Flight Center for distribution by request to the astronomical community.

Jewell, P. R.↗

Flat-Panel Wideband Dual-Circularly Polarized 8X8 Phased Array Antenna for SATCOM Applications

A wideband, dual-circularly polarized (CP) 8×8 phased array is designed for operation at K-/Ka-band, which exhibits wide impedance and axial ratio (AR) bandwidths that encompass both of the desired satellite communication (SATCOM) bands of 22.55–23.55 GHz and 25.5–27.5 GHz. The array has a scan range of ±50° and ±36° at 23.05 GHz and 26.5 GHz, which are the center frequencies of the two aforementioned bands. The array has been integrated with a beamforming network utilizing 5G silicon RFICs, and the measurement results will be presented during the conference.

phased array antenna↗

Effect of Low Temperature Nitrogen Baking on Superconducting Radio Frequency Cavities With Different Frequency

We report the rf performance of several single-cell superconducting radiofrequency cavities frequency ranging from 1.3-3.0 GHz after low temperature baking in nitrogen environment The cavities are treated at different temperature in the range of (120-160oC) for extended period of time (~24-48 hours) with nitrogen gas injection in the furnace. The improvement in Q0 with Q-rise in some case was observed when nitrogen gas was injected at elevated temperature (~250-290 oC) and held at the temperature range 120-200 oC without any degradation in accelerating gradient over the baseline performance. The temperature and time of baking play significant role in dependence of quality factor on accelerating gradient.

Khanal, B.↗

Forged Ingot Niobium Technology for Accelerator Applications and Scientific Frontiers

We report the rf performance of several single-cell superconducting radiofrequency cavities frequency ranging from 1.3-3.0 GHz after low temperature baking in nitrogen environment The cavities are treated at different temperature in the range of (120-160oC) for extended period of time (~24-48 hours) with nitrogen gas injection in the furnace. The improvement in Q0 with Q-rise in some case was observed when nitrogen gas was injected at elevated temperature (~250-290 oC) and held at the temperature range 120-200 oC without any degradation in accelerating gradient over the baseline performance. The temperature and time of baking play significant role in dependence of quality factor on accelerating gradient.

Khanal, B.↗

Measurements and Calculations of Microwave Radiance and Reflectivity for Storm-Associated Frozen Hydrometeors

During the TEFLUN-B (Texas-Florida under-flights for the Tropical Rainfall Measuring Mission (TRMM)) field experiment of August-September, 1998, a number of ER-2 aircraft flights with a host of microwave instruments were conducted over many convective storms, including some hurricanes, in the coastal region of Florida and Texas. These instruments include MIR (Millimeter-wave Imaging Radiometer), AMPR (Advanced Microwave Precipitation Radiometer), and EDOP (ER-2 Doppler Radar). EDOP is operated at the frequency of 9.7 GHz, while the AMPR and the MIR together give eleven channels of radiometric measurements in the frequency range of 10-340 GHz. The concurrent measurements from these instruments provide unique data sets for studying the details of the microphysics of hydrometeors. Preliminary examination of these data sets shows features that are generally well understood; i.e., radiometric measurements at frequencies <= 37 GHz mainly respond to rain, while those at frequencies >= 150 GHz, to snow and ice clouds above the freezing level. In this paper we present results of comparisons between these measurements and model calculations of brightness temperature and radar reflectivity. For simplicity the analysis is limited to the anvil region of the storms where only frozen hydrometeors are present. Various models of particle size distribution (e.g., Gunn-Marshall, Sekhon-Srivastava, and the Central Equatorial Pacific Experiment (CEPEX)) are examined in the calculations of brightness temperatures at the MIR frequencies and radar reflectivity at the EDOP frequency. Estimation of ice water path is made based on the best agreement between the measurements and calculations of brightness temperature and reflectivity. Problems associated with these analyses and measurement accuracy will be discussed.

Wang, James R.↗

Measurements and Calculations of Microwave Radiance and Reflectivity for Storm-Associated Frozen Hydrometeors

During the TEFLUN-B (Texas-Florida under-flights for TRMM) field experiment of August-September, 1998, a number of ER-2 aircraft flights with a host of microwave instruments were conducted over many convective storms, including some hurricanes, in the coastal region of Florida and Texas. These instruments include MIR (Millimeter-wave Imaging Radiometer), AMPR (Advanced Microwave Precipitation Radiometer), and EDOP (ER-2 Doppler Radar). EDOP is operated at the frequency of 9.7 GHz, while the AMPR and the MIR together give eleven channels of radiometric measurements in the frequency range of 10-340 GHz. The concurrent measurements from these instruments provide unique data sets for studying the details of the microphysics of hydrometeors. Preliminary examination of these data sets shows features that are generally well understood; i.e., radiometric measurements at frequencies less than or equal to 37 GHz mainly respond to rain, while those at frequencies greater than or equal to 150 GHz, to ice particles above the freezing level. Model calculations of brightness temperature and radar reflectivity are performed and results compared with these measurements. For simplicity the analysis is limited to the anvil region of the storms where hydrometeors are predominantly frozen. Only one ice particle size distribution is examined in the calculations of brightness temperature and radar reflectivity in this initial study. Estimation of ice water path is made based on the best agreement between the measurements and calculations of brightness temperature and reflectivity. Problems associated with these analyses and measurement accuracy will be discussed.

Wang, James R.↗

High-resolution imaging of rain systems with the advanced microwave precipitation radiometer

An advanced Microwave Precipitation Radiometer (AMPR) has been developed and flown in the NASA ER-2-high-altitude aircraft for imaging various atmospheric and surface processes, primarily the internal structure of rain clouds. The AMPR is a scanning four-frequency total power microwave radiometer that is externally calibrated with high-emissivity warm and cold loads. Separate antenna systems allow the sampling of the 10.7- and 19.35-GHz channels at the same spatial resolution, while the 37.1- and 85.5-GHz channels utilize the same multifrequency feedhorn as the 19.35-GHz channel. Spatial resolutions from an aircraft altitude of 20-km range from 0.6 km at 85.5 GHz to 2.8 km at 19.35 and 10.7 GHz. All channels are sampled every 0.6 km in both along-track and cross-track directions, leading to a contiguous sampling pattern of the 85.5-GHz 3-dB beamwidth footprints, 2.3X oversampling of the 37.1-GHz data, and 4.4X oversampling of the 19.35- and 10.7-GHz data. Radiometer temperature sensitivities range from 0.2 to 0.5 C. Details of the system are described, including two different calibration systems and their effect on the data collected. Examples of oceanic rain systems are presented from Florida and the tropical west Pacific that illustrate the wide variety of cloud water, rainwater, and precipitation-size ice combinations that are observable from aircraft altitudes.

Spencer, Roy W.↗

A 75-116-Ghz LNA with 23-K Noise Temperature at 108 Ghz

In this paper we present the design and measurement results, both on-wafer and in package, of an ultra-low-noise and wideband monolithic microwave integrated circuit (MMIC) amplifier in the frequency range of 75 to 116 GHz. The three-stage amplifier packaged in a WR10 waveguide housing and fabricated using a 35-nm InP HEMT technology achieves a record noise temperature of 23 K at 108 GHz when cryogenically cooled to 27 K. The measured gain is 22 to 27 dB for frequency range of 75 to 116 GHz. Furthermore, the amplifier utilizes four finger devices with total gate width of 60 um resulting for improved linearity.

monolithic microwave integrated circuit (MMIC)↗

An adjustable RF tuning element for microwave, millimeter wave, and submillimeter wave integrated circuits

Planar RF circuits are used in a wide range of applications from 1 GHz to 300 GHz, including radar, communications, commercial RF test instruments, and remote sensing radiometers. These circuits, however, provide only fixed tuning elements. This lack of adjustability puts severe demands on circuit design procedures and materials parameters. We have developed a novel tuning element which can be incorporated into the design of a planar circuit in order to allow active, post-fabrication tuning by varying the electrical length of a coplanar strip transmission line. It consists of a series of thin plates which can slide in unison along the transmission line, and the size and spacing of the plates are designed to provide a large reflection of RF power over a useful frequency bandwidth. Tests of this structure at 1 GHz to 3 Ghz showed that it produced a reflection coefficient greater than 0.90 over a 20 percent bandwidth. A 2 GHz circuit incorporating this tuning element was also tested to demonstrate practical tuning ranges. This structure can be fabricated for frequencies as high as 1000 GHz using existing micromachining techniques. Many commercial applications can benefit from this micromechanical RF tuning element, as it will aid in extending microwave integrated circuit technology into the high millimeter wave and submillimeter wave bands by easing constraints on circuit technology.

Lubecke, Victor M.↗

Assimilation of Precipitation Measurement Missions Microwave Radiance Observations With GEOS-5

The Global Precipitation Mission (GPM) Core Observatory satellite was launched in February, 2014. The GPM Microwave Imager (GMI) is a conically scanning radiometer measuring 13 channels ranging from 10 to 183 GHz and sampling between 65 S 65 N. This instrument is a successor to the Tropical Rainfall Measurement Mission (TRMM) Microwave Imager (TMI), which has observed 9 channels at frequencies ranging 10 to 85 GHz between 40 S 40 N since 1997. This presentation outlines the base procedures developed to assimilate GMI and TMI radiances in clear-sky conditions, including quality control methods, thinning decisions, and the estimation of, observation errors. This presentation also shows the impact of these observations when they are incorporated into the GEOS-5 atmospheric data assimilation system.

GPM/GMI↗