Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Functionally Graded”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Randomized Control Trial: Evaluating Aluminum-Based Antiperspirant Use, Axilla Skin Toxicity, and Reported Quality of Life in Women Receiving External Beam Radiotherapy for Treatment of Stage 0, I, and II Breast Cancer

Purpose: Standard skin care instructions regarding the use of antiperspirants during radiotherapy to the breast varies across North America. Women have articulated that when instructed to not use antiperspirant, the potential for body odor is distressing. Historical practices and individual opinions have often guided practice in this field. The present study had 2 purposes. To evaluate whether the use of aluminum-based antiperspirant while receiving external beam radiotherapy for stage 0, I, or II breast cancer will increase axilla skin toxicity and to evaluate whether the use of antiperspirant during external beam radiotherapy improves quality of life. Methods: A total of 198 participants were randomized to either the experimental group (antiperspirant) or control group (standard care-wash only). The skin reactions in both groups were measured weekly and 2 weeks after treatment using the National Cancer Institute Common Toxicity Criteria Adverse Events, version 3, toxicity grading criteria. Both groups completed the Functional Assessment for Chronic Illness Therapy's questionnaire for the breast population quality of life assessment tool, with additional questions evaluating the effect of underarm antiperspirant use on quality of life before treatment, immediately after treatment, and 2 weeks after treatment during the study. Results: The skin reaction data were analyzed using the generalized estimating equation. No statistically significant difference was seen in the skin reaction between the 2 groups over time. The quality of life data also revealed no statistically significant difference between the 2 groups over time. Conclusions: Data analysis indicates that using antiperspirant routinely during external beam radiotherapy for Stage 0, I, or II breast cancer does not affect the intensity of the skin reaction or the self-reported quality of life. This evidence supports that in this particular population, there is no purpose to restrict these women from using antiperspirants during their treatment, and the decision to use an antiperspirant or not in this setting should be left to the discretion of the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bursting into space: alterations of sympathetic control by space travel

AIM: Astronauts return to Earth with reduced red cell masses and hypovolaemia. Not surprisingly, when they stand, their heart rates may speed inordinately, their blood pressures may fall, and some may experience frank syncope. We studied autonomic function in six male astronauts (average +/- SEM age: 40 +/- 2 years) before, during, and after the 16-day Neurolab space shuttle mission. METHOD: We recorded electrocardiograms, finger photoplethysmographic arterial pressures, respiration, peroneal nerve muscle sympathetic activity, plasma noradrenaline and noradrenaline kinetics, and cardiac output, and we calculated stroke volume and total peripheral resistance. We perturbed autonomic function before and during spaceflight with graded Valsalva manoeuvres and lower body suction, and before and after the mission with passive upright tilt. RESULTS: In-flight baseline sympathetic nerve activity was increased above pre-flight levels (by 10-33%) in three subjects, in whom noradrenaline spillover and clearance also were increased. Valsalva straining provoked greater reductions of arterial pressure, and proportionally greater sympathetic responses in space than on Earth. Lower body suction elicited greater increases of sympathetic nerve activity, plasma noradrenaline, and noradrenaline spillover in space than on Earth. After the Neurolab mission, left ventricular stroke volume was lower and heart rate was higher during tilt, than before spaceflight. No astronaut experienced orthostatic hypotension or pre-syncope during 10 min of post-flight tilting. CONCLUSION: We conclude that baseline sympathetic outflow, however measured, is higher in space than on earth, and that augmented sympathetic nerve responses to Valsalva straining, lower body suction, and post-flight upright tilt represent normal adjustments to greater haemodynamic stresses associated with hypovolaemia.

NASA Program Biomedical Research and Countermeasur↗

The MPC&A Questionnaire

The questionnaire is the instrument used for recording performance data on the nuclear material protection, control, and accountability (MPC&A) system at a nuclear facility. The performance information provides a basis for evaluating the effectiveness of the MPC&A system. The goal for the questionnaire is to provide an accurate representation of the performance of the MPC&A system as it currently exists in the facility. Performance grades for all basic MPC&A functions should realistically reflect the actual level of performance at the time the survey is conducted. The questionnaire was developed after testing and benchmarking the material control and accountability (MC&A) system effectiveness tool (MSET) in the United States. The benchmarking exercise at the Idaho National Laboratory (INL) proved extremely valuable for improving the content and quality of the early versions of the questionnaire. Members of the INL benchmark team identified many areas of the questionnaire where questions should be clarified and areas where additional questions should be incorporated. The questionnaire addresses all elements of the MC&A system. Specific parts pertain to the foundation for the facility's overall MPC&A system, and other parts pertain to the specific functions of the operational MPC&A system. The questionnaire includes performance metrics for each of the basic functions or tasks performed in the operational MPC&A system. All of those basic functions or tasks are represented as basic events in the MPC&A fault tree. Performance metrics are to be used during completion of the questionnaire to report what is actually being done in relation to what should be done in the performance of MPC&A functions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Lunar Health Monitor (LHM)

Orbital Research, Inc., has developed a low-profile, wearable sensor suite for monitoring astronaut health in both intravehicular and extravehicular activities. The Lunar Health Monitor measures respiration, body temperature, electrocardiogram (EKG) heart rate, and other cardiac functions. Orbital Research's dry recording electrode is central to the innovation and can be incorporated into garments, eliminating the need for conductive pastes, adhesives, or gels. The patented dry recording electrode has been approved by the U.S. Food and Drug Administration. The LHM is easily worn under flight gear or with civilian clothing, making the system completely versatile for applications where continuous physiological monitoring is needed. During Phase II, Orbital Research developed a second-generation LHM that allows sensor customization for specific monitoring applications and anatomical constraints. Evaluations included graded exercise tests, lunar mission task simulations, functional battery tests, and resting measures. The LHM represents the successful integration of sensors into a wearable platform to capture long-duration and ambulatory physiological markers.

Lisy, Frederick J.↗

Experimental Investigation of Gas/Slag/Matte/Tridymite Equilibria in the Cu-Fe-O-S-Si System in Controlled Gas Atmospheres: Experimental Results at 1473 K (1200 °C) and P(SO{sub 2}) = 0.25 atm

Experimental studies were undertaken to determine the gas/slag/matte/tridymite equilibria in the Cu-Fe-O-S-Si system at 1473 K (1200 °C), P(SO{sub 2}) = 0.25 atm, and a range of P(O{sub 2})’s. The experimental methodology involved high-temperature equilibration using a substrate support technique in controlled gas atmospheres (CO/CO{sub 2}/SO{sub 2}/Ar), rapid quenching of equilibrium phases, followed by direct measurement of the chemical compositions of the phases with Electron Probe X-ray Microanalysis (EPMA). The experimental data for slag and matte were presented as a function of copper concentration in matte (matte grade). The data provided are essential for the evaluation of the effect of oxygen potential under controlled atmosphere on the matte grade, liquidus composition of slag and chemically dissolved copper in slag. The new data provide important accurate and reliable quantitative foundation for improvement of the thermodynamic databases for copper-containing systems.

36 MATERIALS SCIENCE↗

Oxide heterostructures for ecient solar cells

We propose an unexplored class of absorbing materials for high-efficiency solar cells: heterostructures of transition-metal oxides. In particular, LaVO3 grown on SrTiO3 has a direct band gap ~1.1 eV in the optimal range as well as an internal potential gradient, which can greatly help to separate the photogenerated electron-hole pairs. Furthermore, oxide heterostructures afford the flexibility to combine LaVO3 with other materials such as LaFeO3 in order to achieve even higher efficiencies with band-gap graded solar cells. We use density-functional theory to demonstrate these features.

oxide heterostructures↗

Pre-Commercial Demonstration of Direct Non-Iterative State Estimator (DNSE+)

The objective of this DOE co-funded project is to demonstrate functionality and performance of a production-grade Direct Non-iterative State Estimator (DNSE) through its integration with NYPA’s Energy Management System (EMS) and an enhanced Real Time Dynamics Monitoring System (RTDMS) synchrophasor platform from Electric Power Group (EPG). A production-grade DNSE aims to overcome a major obstacle to the operational use of synchrophasor data in Synchro-Phasor Management Systems (SPMS) by providing SPMS applications with a consistent and a complete synchrophasor data foundation in the same way that a traditional EMS State Estimator (SE) provides to EMS applications. Specifically, the DNSE uses synchrophasor measurements and Supervisory Control and Data Acquisition (SCADA) measurements, together with the complete power system model, to simultaneously obtain the complete state of the entire utility’s operating model at rates that are close to the synchrophasor data rates. The full system coverage property is what distinguishes the DNSE from the linear synchrophasor SEs (which cover only parts of the operating model that are visible through synchrophasor measurements), and DNSE differs from traditional EMS SE in that the solution is obtained without iterations, without initial values (hence the “direct” in the name), and at a much higher execution rate. This presentation provides an overview of the project objectives, a brief description of the main tasks including the development work to productize and optimize DNSE from its current MATLAB code base, RTDMS enhancement for interfacing with the DNSE, factory acceptance testing, field installation, testing and demonstration, as well as the current status of the project execution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multijunction solar cells with graded buffer Bragg reflectors

Distributed Bragg reflectors are incorporated into the compositionally graded buffers of metamorphic solar cells, adding functionality to the buffer without adding cost. The reflection aids in collection in subcells that are optically thin due to low diffusion length, high bulk recombination, radiation hardness, partially-absorbing quantum structures, or simply for cost savings. Performance enhancements are demonstrated in GaAs subcells with QWs, which is beneficial when GaAs is not the ideal bandgap.

France, Ryan Matthew↗

Mathematics Integrated with Computer Science through Scratch: Curricular Modules for the Middle Grades

A project funded by the National Science Foundation, Computer Science Integrated with Mathematics in Middle Schools (CSIMMS) (DRL-1640039), brought middle-school mathematics teachers together with university computer science (CS) faculty and STEM education faculty to design, develop, and test curriculum modules in which CS is integrated into instruction for middle-school general-mathematics courses. The project developed integrated math/CS curriculum modules (for grades 6, 7, and 8), complete with student tasks and teacher materials to guide classroom implementation. Across the project, sixteen teachers from four middle schools representing different school contexts (both urban and suburban, serving students from a range of demographic and socioeconomic backgrounds) participated as members of the design team and trial testers of the math/CS modules. All modules underwent multiple years of testing and refinement, with extensive input from the teachers who co-designed and implemented them. Approximately 50-100 middle-school students participated in the classes of those who taught each year. The modules in this volume feature a range of models for integrating mathematics and computer science at the 6th and 7th grade levels. All modules foreground the teaching of grade-level mathematics content, with computer science functioning to motivate and/or reinforce these ideas.

Andrews larson, Christine↗

Reconstruction of Thermal Protection System Aeroheating using a Green’s Function Approach

Inverse heat transfer (IHT) techniques are often used to reconstruct the surface heating conditions on spacecraft thermal protection systems (TPS) during atmospheric entry. Current IHT techniques for entry spacecraft applications, however, demand substantial computational resources, and are impractical for analyses such as uncertainty quantification and real-time health monitoring. In this paper, a Green’s function sensor fusion approach is used to reconstruct the TPS surface aeroheating conditions on experimental spaceflight and ground test systems from collocated temperature and heat flux sensors embedded in the TPS. The algorithm leverages Green’s functions to model the heat conduction within the spacecraft TPS and stabilizes the recovery of the surface heating condition using the direct heat flux sensor measurement. The algorithm is validated using arc-jet ground test data and applied to the reconstruction of the Mars 2020 backshell heating during Martian atmospheric entry. The performance of the algorithm is benchmarked against a current state-of-the-art IHT framework, FIAT_Opt. The Green’s function-based reconstruction algorithm recovers the net hot-wall heat flux absorbed by the TPS and the incident heat flux from the atmospheric entry environment in close agreement with FIAT_Opt. Notably, computation of the surface heating condition is completed in three orders of magnitude less time with the Green’s function sensor fusion approach using a consumer-grade PC, versus with FIAT_Opt running on a high performance computer cluster. The efficiency of the algorithm is leveraged to compute the uncertainty contributions of input parameters to the total uncertainty in reconstructed Mars 2020 backshell heating for the full atmospheric entry heat pulse. The sensitivity analysis uncovers that, at different times throughout the entry heat pulse, uncertainties in the TPS specific heat, thermal conductivity, and emissivity are all dominant drivers of the reconstruction uncertainty. These results demonstrate Green’s functions and sensor-fusion techniques as promising IHT approaches to reconstruct atmospheric entry environments from TPS-embedded measurements, and highlight how these techniques may give access to post-flight analyses previously hindered by the prohibitive cost of current methods.

Kenneth McAfee↗

Reconstruction of Thermal Protection System Aeroheating using a Green’s Function Approach

Inverse heat transfer (IHT) techniques are often used to reconstruct the surface heating conditions on spacecraft thermal protection systems (TPS) during atmospheric entry. Current IHT techniques for entry spacecraft applications, however, demand substantial computational resources, and are impractical for analyses such as uncertainty quantification and real-time health monitoring. In this paper, a Green’s function sensor fusion approach is used to reconstruct the TPS surface aeroheating conditions on experimental spaceflight and ground test systems from collocated temperature and heat flux sensors embedded in the TPS. The algorithm leverages Green’s functions to model the heat conduction within the spacecraft TPS and stabilizes the recovery of the surface heating condition using the direct heat flux sensor measurement. The algorithm is validated using arc-jet ground test data and applied to the reconstruction of the Mars 2020 backshell heating during Martian atmospheric entry. The performance of the algorithm is benchmarked against a current state-of-the-art IHT framework, FIAT_Opt. The Green’s function-based reconstruction algorithm recovers the net hot-wall heat flux absorbed by the TPS and the incident heat flux from the atmospheric entry environment in close agreement with FIAT_Opt. Notably, computation of the surface heating condition is completed in three orders of magnitude less time with the Green’s function sensor fusion approach using a consumer-grade PC, versus with FIAT_Opt running on a high performance computer cluster. The efficiency of the algorithm is leveraged to compute the uncertainty contributions of input parameters to the total uncertainty in reconstructed Mars 2020 backshell heating for the full atmospheric entry heat pulse. The sensitivity analysis uncovers that, at different times throughout the entry heat pulse, uncertainties in the TPS specific heat, thermal conductivity, and emissivity are all dominant drivers of the reconstruction uncertainty. These results demonstrate Green’s functions and sensor-fusion techniques as promising IHT approaches to reconstruct atmospheric entry environments from TPS-embedded measurements, and highlight how these techniques may give access to post-flight analyses previously hindered by the prohibitive cost of current methods.

Kenneth McAfee↗

Thermal Aging Effects on the Yield and Tensile Strength of 9Cr-1Mo-V (Grade 91)

The long-term exposure of 9Cr-1Mo-V (Grade 91) steel to elevated temperature can have a significant effect on reducing its yield and tensile strength. The yield and tensile strength changes, in turn, have potential implications to the assurance of the integrity of components constructed with this material over their design or intended lifetime. The ASME Boiler & Pressure Vessel Code (BPVC), Section III, Division 5 (III-5, high temperature reactors) provides tabulated reduction factors for Grade 91 yield and tensile strength as a function of exposure temperature and time up to 300,000 h. ASME BPVC III-5 s intent to extend these factors to an exposure duration of 500,000 h, the lack of available historic information to support the existing factors, and the recent development of a physics-based prediction model for ASME BPVC application are prime motivation for this study. This work describes results of the conventional time-temperature Hollomon–Jaffe parameter, strength reduction ratio prediction method using an updated, extensive Grade 91 unaged and related aged material strength database. The method, previously used by Oak Ridge National Laboratory in its evaluation of Grade 91 and likely used in development of the existing BPVC III-5 reduction factors, provides strength reduction ratio predictions useful for general component fitness-for-service assessments and for computing BPVC III-5 reduction factors as defined. Specific reduction factors to 500,000 h at 650 °C applicable to ASME BPVC III-5 are computed from the strength reduction ratios.

36 MATERIALS SCIENCE↗

Impact of Toxicity Grade and Scoring System on the Relationship Between Mean Lung Dose and Risk of Radiation Pneumonitis in a Large Cohort of Patients With Non-Small Cell Lung Cancer

Purpose: To compute the risk of radiation pneumonitis (RP) as a function of mean lung dose (MLD), with RP scored using three grading systems and analyzed at four threshold levels of toxicity in a large cohort of patients with non-small cell lung cancer (NSCLC) treated with definitive radiotherapy (RT). Methods and Materials: On the basis of medical records and radiographic images, RP was scored retrospectively in 442 patients with NSCLC who had {>=}6 months of follow-up after the end of RT. The severity of RP was scored for each patient using the National Cancer Institute (NCI) Common Toxicity Criteria, version 2.0 (CTC2.0); the NCI Common Terminology Criteria for Adverse Events, version 3.0 (CTCAE3.0); and the grading system of the Radiation Therapy Oncology Group (RTOG). For each grading system and for each of four levels of toxicity (Grade {>=}1, {>=}2, {>=}3, {>=}4), the Lyman, logistic, and log-logistic normal tissue complication probability (NTCP) models were fitted to the data as functions of MLD. The parameter estimates from the model fits are listed in table form, and the RP risk estimates are presented graphically for the Lyman and log-logistic NTCP models. Results: The results presented here illustrate the impact of scoring system and level of toxicity on the relationship between MLD and RP risk. Conclusions: These results facilitate quantitative comparisons between our data and studies of RP risk reported by others, and several examples of such comparisons are provided.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TREATMENT TANK OFF-GAS TESTING FOR THE ENHANCED CHEMICAL CLEANING PROCESS

The purpose of this activity was to provide a bounding estimate of the volume of hydrogen gas generated during Enhanced Chemical Cleaning (ECC) of residual sludge remaining in a Type I or Type II treatment tank as well as to provide results independent of the sludge volume in the waste tank to be cleaned. Previous testing to support Chemical Cleaning was based on a 20:1 oxalic acid to sludge ratio. Hydrogen gas evolution is the primary safety concern. Sealed vessel coupon tests were performed to estimate the hydrogen generation rate due to corrosion of carbon steel by 2.5 wt.% oxalic acid. These tests determined the maximum instantaneous hydrogen generation rate, the rate at which the generation rate decays, and the total hydrogen generated. These values were quantified based on a small scale methodology similar to the one described in WSRC-STI-2007-00209, Rev. 0. The measured rates support identified Safety Class functions. The tests were performed with ASTM A285 Grade C carbon steel coupons. Bounding conditions were determined for the solution environment. The oxalic acid concentration was 2.5 wt.% and the test temperature was 75 C. The test solution was agitated and contained no sludge simulant. Duplicate tests were performed and showed excellent reproducibility for the hydrogen generation rate and total hydrogen generated. The results showed that the hydrogen generation rate was initially high, but decayed rapidly within a couple of days. A statistical model was developed to predict the instantaneous hydrogen generation rate as a function of exposure time by combining both sets of data. An upper bound on the maximum hydrogen generation rate was determined from the upper 95% confidence limit. The upper bound confidence limit for the hydrogen generation rate is represented by the following equation. ln (G{sub v}) = -8.22-0.0584 t + 0.0002 t{sup 2}. This equation should be utilized to estimate the instantaneous hydrogen generation rate per unit surface area, G{sub v}, at a given time, t. The units for G{sub v} and t are ft{sup 3}/ft{sup 2}/min and hours, respectively. The total volume of hydrogen gas generated during the test was calculated from the model equation. An upper bound on the total gas generated was determined from the upper 95% confidence limit. The upper bound limit on the total hydrogen generated during the 163 hour test was 0.332 ft{sup 3}/ft{sup 2}. The maximum instantaneous hydrogen generation rate for this scenario is greater than that previously measured in the 8 wt.% oxalic acid tests due to both the absence of sludge in the test (i.e., greater than 20:1 ratio of acid to sludge) and the use of polished coupons (vs. mill scale coupons). However, due to passivation of the carbon steel surface, the corrosion rate decays by an order of magnitude within the first three days of exposure such that the instantaneous hydrogen generation rates are less than that previously measure in the 8 wt.% oxalic acid tests. While the results of these tests are bounding, the conditions used in this study may not be representative of the ECC flowsheet, and the applicability of these results to the flowsheet should be evaluated for the following reasons: (1) The absence of sludge results in higher instantaneous hydrogen generation rates than when the sludge is present; and (2) Polished coupons do not represent the condition of the carbon steel interior of the tank, which are covered with mill scale. Based on lower instantaneous corrosion rates measured on mill scale coupons exposed to oxalic acid, lower instantaneous hydrogen generation rates are expected for the tank interior than measured on the polished coupons. Corrosion rates were determined from the coupon tests and also calculated from the measured hydrogen generation rates. Excellent agreement was achieved between the time averaged corrosion rate calculated from the hydrogen generation rates and the corrosion rates determined from the coupon tests. The corrosion rates were on the order of 18 to 28 mpy. Good agreement was also observed between the maximum instantaneous corrosion rate as calculated from the hydrogen generation rate and the corrosion rate determined by previous electrochemical tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Predicting Pneumonitis Risk: A Dosimetric Alternative to Mean Lung Dose

Purpose: To determine whether the association between mean lung dose (MLD) and risk of severe (grade {>=}3) radiation pneumonitis (RP) depends on the dose distribution pattern to normal lung among patients receiving 3-dimensional conformal radiation therapy for non-small-cell lung cancer. Methods and Materials: Three cohorts treated with different beam arrangements were identified. One cohort (2-field boost [2FB]) received 2 parallel-opposed (anteroposterior-posteroanterior) fields per fraction initially, followed by a sequential boost delivered using 2 oblique beams. The other 2 cohorts received 3 or 4 straight fields (3FS and 4FS, respectively), ie, all fields were irradiated every day. The incidence of severe RP was plotted against MLD in each cohort, and data were analyzed using the Lyman-Kutcher-Burman (LKB) model. Results: The incidence of grade {>=}3 RP rose more steeply as a function of MLD in the 2FB cohort (N=120) than in the 4FS cohort (N=138), with an intermediate slope for the 3FS group (N=99). The estimated volume parameter from the LKB model was n=0.41 (95% confidence interval, 0.15-1.0) and led to a significant improvement in fit (P=.05) compared to a fit with volume parameter fixed at n=1 (the MLD model). Unlike the MLD model, the LKB model with n=0.41 provided a consistent description of the risk of severe RP in all three cohorts (2FB, 3FS, 4FS) simultaneously. Conclusions: When predicting risk of grade {>=}3 RP, the mean lung dose does not adequately take into account the effects of high doses. Instead, the effective dose, computed from the LKB model using volume parameter n=0.41, may provide a better dosimetric parameter for predicting RP risk. If confirmed, these findings support the conclusion that for the same MLD, high doses to small lung volumes ('a lot to a little') are worse than low doses to large volumes ('a little to a lot').

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Theory of biaxial graded-index optical fiber

A biaxial graded-index fiber with a homogeneous cladding is studied. Two methods, wave equation and matrix differential equation, of formulating the problem and their respective solutions are discussed. For the wave equation formulation of the problem it is shown that for the case of a diagonal permittivity tensor the longitudinal electric and magnetic fields satisfy a pair of coupled second-order differential equations. Also, a generalized dispersion relation is derived in terms of the solutions for the longitudinal electric and magnetic fields. For the case of a step-index fiber, either isotropic or uniaxial, these differential equations can be solved exactly in terms of Bessel functions. For the cases of an istropic graded-index and a uniaxial graded-index fiber, a solution using the Wentzel, Krammers and Brillouin (WKB) approximation technique is shown. Results for some particular permittivity profiles are presented. Also the WKB solutions is compared with the vector solution found by Kurtz and Streifer. For the matrix formulation it is shown that the tangential components of the electric and magnetic fields satisfy a system of four first-order differential equations which can be conveniently written in matrix form. For the special case of meridional modes, the system of equations splits into two systems of two equations. A general iterative technique, asymptotic partitioning of systems of equations, for solving systems of differential equations is presented. As a simple example, Bessel's differential equation is written in matrix form and is solved using this asymptotic technique. Low order solutions for particular examples of a biaxial and uniaxial graded-index fiber are presented. Finally numerical results obtained using the asymptotic technique are presented for particular examples of isotropic and uniaxial step-index fibers and isotropic, uniaxial and biaxial graded-index fibers.

Kawalko, Stephen F.↗

Hemithoracic Intensity Modulated Radiation Therapy After Pleurectomy/Decortication for Malignant Pleural Mesothelioma: Toxicity, Patterns of Failure, and a Matched Survival Analysis

Purpose: To investigate safety, efficacy, and recurrence after hemithoracic intensity modulated radiation therapy after pleurectomy/decortication (PD-IMRT) and after extrapleural pneumonectomy (EPP-IMRT). Methods and Materials: In 2009-2013, 24 patients with mesothelioma underwent PD-IMRT to the involved hemithorax to a dose of 45 Gy, with an optional integrated boost; 22 also received chemotherapy. Toxicity was scored with the Common Terminology Criteria for Adverse Events v4.0. Pulmonary function was compared at baseline, after surgery, and after IMRT. Kaplan-Meier analysis was used to calculate overall survival (OS), progression-free survival (PFS), time to locoregional failure, and time to distant metastasis. Failures were in-field, marginal, or out of field. Outcomes were compared with those of 24 patients, matched for age, nodal status, performance status, and chemotherapy, who had received EPP-IMRT. Results: Median follow-up time was 12.2 months. Grade 3 toxicity rates were 8% skin and 8% pulmonary. Pulmonary function declined from baseline to after surgery (by 21% for forced vital capacity, 16% for forced expiratory volume in 1 second, and 19% for lung diffusion of carbon monoxide [P for all = .01]) and declined still further after IMRT (by 31% for forced vital capacity [P=.02], 25% for forced expiratory volume in 1 second [P=.01], and 30% for lung diffusion of carbon monoxide [P=.01]). The OS and PFS rates were 76% and 67%, respectively, at 1 year and 56% and 34% at 2 years. Median OS (28.4 vs 14.2 months, P=.04) and median PFS (16.4 vs 8.2 months, P=.01) favored PD-IMRT versus EPP-IMRT. No differences were found in grade 4-5 toxicity (0 of 24 vs 3 of 24, P=.23), median time to locoregional failure (18.7 months vs not reached, P not calculable), or median time to distant metastasis (18.8 vs 11.8 months, P=.12). Conclusions: Hemithoracic intensity modulated radiation therapy after pleurectomy/decortication produced little high-grade toxicity but led to progressive declines in pulmonary function; OS and PFS were better in PD-IMRT compared with EPP-IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗