Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Focusing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Fracture toughness of zirconia with a nanometer size notch fabricated using focused ion beam milling

Zirconia with 3 mol% yttria (3Y-TZP) has been used for dental crowns and bridges due to its excellent mechanical behavior. Performing fracture toughness testing on this nanograin material, however, can be a challenge. For reliable results, fracture toughness testing requires an extremely sharp notch in the test specimen that closely approximates a very sharp crack. This study was to investigate an alternative method to produce nanometer-sized notches, which are less than the average grain size of 3Y-TZP, during the preparation of single-edge V-notched beam specimens and report the resulting fracture toughness value. We present a method using focused ion beam (FIB) milling to fabricate nanometer-sized notches in 3Y-TZP. The notch tip is <100 nm wide, which is smaller than the grain size, and is consistent throughout the thickness of the specimen. The FIB-notched specimens show a much reduced average fracture toughness of 5.64 ± 1.14 MPa√m compared to 8.90 ± 0.23 MPa√m for the specimens without FIB-notches. The FIB-milling did not appear to create any monoclinic phase prior to fracture toughness testing. Fractures originated at the FIB-notches, and the notch size can be readily identified post-mortem using a microscope. A considerable amount of tetragonal-to-monoclinic phase transformation was observed throughout the fracture surfaces. FIB milling provides an alternative method to fabricate nanometer-sized notches that are smaller than the grain size of tetragonal zirconia polycrystal. The fracture toughness determined using FIB-notches was ~5.64 MPa√m, smaller than the specimens with V-notches fabricated using saw blades.

36 MATERIALS SCIENCE↗

Recent Progress and Development of Self-Aligned Focusing Schlieren

A broad range of developments and applications of self-aligned focusing schlieren (SAFS)systems is presented. The replacement of the Ronchi ruling (RR) with a𝜇LCD was demonstrated with digital SAFS, which provides the ability to modulate the pattern and orientation without physical intervention. Additionally, replacement of the traditional RR with spectral-spatial filters was demonstrated to yield the ability to simultaneously image horizontal and vertical index of refraction gradients using two separate wavelengths. The application of the Scheimpflug principle to SAFS systems enables off-axis imaging and allowed for extended fields-of-view to be captured using a two-camera system. The addition of a plenoptic camera to a baseline SAFS system enables refocusing capabilities, which is demonstrated on two jets offset along the optical axis. Furthermore, application of an event-based camera to SAFS was shown to enable acquisition of sparse, spatio-temporal data. Beyond the listed developments, SAFS was applied to difficult and constraining facilities, such as the National Full-Scale Aerodynamics Complex(NFAC) 80- by 120-ft Wind Tunnel and the Thermal Acoustic Engines (TAE) rig at NASA Ames Research Center and NASA Glenn Research Center, respectively. Behavior of Ronchi rulings, Rochon prisms, and the use of quarter-wave plates versus quarter-wave films are evaluated to provide insight for future experimental design of SAFS-systems.

Self-Aligned Focusing Schlieren↗

High–Yield Deterministic Focused Ion Beam Implantation of Quantum Defects Enabled by In Situ Photoluminescence Feedback

Focused ion beam implantation is ideally suited for placing defect centers in wide bandgap semiconductors with nanometer spatial resolution. However, the fact that only a few percent of implanted defects can be activated to become efficient single photon emitters prevents this powerful capability to reach its full potential in photonic/electronic integration of quantum defects. Here an industry adaptive scalable technique is demonstrated to deterministically create single defects in commercial grade silicon carbide by performing repeated low ion number implantation and in situ photoluminescence evaluation after each round of implantation. An array of 9 single defects in 13 targeted locations is successfully created—a ≈70% yield which is more than an order of magnitude higher than achieved in a typical single pass ion implantation. The remaining emitters exhibit non-classical photon emission statistics corresponding to the existence of at most two emitters. This approach can be further integrated with other advanced techniques such as in situ annealing and cryogenic operations to extend to other material platforms for various quantum information technologies.

36 MATERIALS SCIENCE↗

Nozzle-Free Printing of CNT Electronics Using Laser-Generated Focused Ultrasound

Printed electronics have made remarkable progress in recent years and inkjet printing (IJP) has emerged as one of the leading methods for fabricating printed electronic devices. However, challenges such as nozzle clogging, and strict ink formulation constraints have limited their widespread use. To address this issue, a novel nozzle-free printing technology is explored, which is enabled by laser-generated focused ultrasound, as a potential alternative printing modality called Shock-wave Jet Printing (SJP). Specifically, the performance of SJP-printed and IJP-printed bottom-gated carbon nanotube (CNT) thin film transistors (TFTs) is compared. While IJP required ten print passes to achieve fully functional devices with channel dimensions ranging from tens to hundreds of micrometers, SJP achieved comparable performance with just a single pass. For optimized devices, SJP demonstrated six times higher maximum mobility than IJP-printed devices. Furthermore, the advantages of nozzle-free printing are evident, as SJP successfully printed stored and unsonicated inks, delivering moderate electrical performance, whereas IJP suffered from nozzle clogging due to CNT agglomeration. Moreover, SJP can print significantly longer CNTs, spanning the entire range of tube lengths of commercially available CNT ink. The findings from this study contribute to the advancement of nanomaterial printing, ink formulation, and the development of cost-effective printable electronics.

47 OTHER INSTRUMENTATION↗

Rethinking radiation effects in materials science using the plasma-focused ion beam

This work demonstrates the viability of using a plasma-focused ion beam (PFIB) as a new platform to carry out radiation effects studies in solids. While materials subjected to irradiation in either nuclear reactors or energetic particle accelerators experience limitations with respect to inaccuracies in both flux measurements and lack of precise control of irradiation areas, we demonstrate a new irradiation technique that allows the exposure of a single specimen in multiple areas, at multiple doses, and in site-specific dependencies - all with flux variations on the order of only 1%. This versatile technique also allows materials to be exposed to significantly higher irradiation dose rates than conventional accelerators. To validate the new methodology, we selected the classical example of ion-beam-induced amorphization of pure single-crystal Si. By pioneering the use of the PFIB for radiation effects studies in materials science, we were able to exploit, in both micro- and nanometer-sized detail, the differences in electron image contrast arising from crystalline versus amorphous solid-state phases in classical semiconductors subjected to irradiation, thus providing new insights on amorphization mechanisms. This methodology opens new research frontiers at the fringe of materials science with promising applications beyond the scope of materials at extremes such as in nanopatterning, nanodevices and nanoarchitectonics.

36 MATERIALS SCIENCE↗

Focused ion beam deposited carbon-platinum nanowires for cryogenic resistive thermometry

The study of thermal effects, both classical and quantum, at cryogenic temperatures requires the use of on-chip, local, high-sensitivity thermometry. Carbon-platinum composites fabricated using focused ion beam (FIB) assisted deposition form a granular structure which is shown in this study to be uniquely suited for this application. Carbon-platinum thermometers deposited using a 24 pA ion beam current have high sensitivities below 1 K, comparable to the best cryogenic thermometers. In addition, these thermometers can be accurately placed to within 10s of nanometers on the chip using a mask-free process. Furthermore, they also have a weak magnetic field dependence, 3% change in resistance with applied magnetic fields from 0 to 8 T. Finally, these thermometers are integrable into a variety of nanoscale devices due to the existing wide spread use of FIB.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Focused ion beam milling of polycrystalline diamond

Focused ion beam (FIB) technology has a large potential for precise milling of ultrahard materials such as diamond. However, studies of the sputtering of diamond with ion species and energies relevant to the FIB technology are scarce. Here, we report a systematic study of the sputtering of polycrystalline diamond surfaces with ion beams in a wide range of ion energies (2 - 30 keV), incident beam angles (0 - 80°), and ion masses (N, O, Ar, and Xe). Results show that the sputter yield is relatively insensitive to ion energy but strongly depends on the ion species and incident beam angles. Bombardment with O ions results in sputter yields that are significantly larger than ballistic predictions due to chemical etching effects. Characteristic surface ripples develop for oblique beam incidence angle irradiation. The critical beam tilt angle for the onset of ripple formation and the wavelength of the ripples depend on ion species and energies. Ripples appear to suppress ion reflection at high beam tilt angles and, hence, a peak in the sputter yield angular dependence. In conclusion, these results have direct implications for the development of process parameter maps for high-precision ion-beam milling of diamond.

36 MATERIALS SCIENCE↗

Linear beam stability in periodic focusing systems: Krein signature and band structure

The general question of how a beam becomes unstable has been one of the fundamental research topics among beam and accelerator physicists for several decades. In this study, we revisited the general problem of linear beam stability in periodic focusing systems by applying the concepts of Krein signature and band structure. We numerically calculated the eigenvalues and other associated characteristics of one-period maps, and discussed the stability properties of single-particle motions with skew quadrupoles and envelope perturbations in high-intensity beams on an equal footing. In particular, an application of the Krein theory to envelope instability analysis was newly attempted in this study. Finally, the appearance of instabilities is interpreted as the result of the collision between eigenmodes of opposite Krein signatures and the formation of a band gap.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ionic Liquid Gating of SrTiO 3 Lamellas Fabricated with a Focused Ion Beam

Here, in this work, we combine two previously incompatible techniques for defining electronic devices: shaping three-dimensional crystals by focused ion beam (FIB), and two-dimensional electrostatic accumulation of charge carriers. The principal challenge for this integration is nanometer-scale surface damage inherent to any FIB-based fabrication. We address this by using a sacrificial protective layer to preserve a selected pristine surface. The test case presented here is accumulation of 2D carriers by ionic liquid gating at the surface of a micron-scale SrTiO 3 lamella. Preservation of surface quality is reflected in superconductivity of the accumulated carriers. This technique opens new avenues for realizing electrostatic charge tuning in materials that are not available as large or exfoliatable single crystals, and for patterning the geometry of the accumulated carriers.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Structural Changes in YBa 2 Cu 3 O 7 Thin Films Modified with He + -Focused Ion Beam for High-Temperature Superconductive Nanoelectronics

Irradiation of high-temperature superconductor YBa 2 Cu 3 O 7 (YBCO) with high-energy He + ions is known to cause structural changes in the YBCO film, decreasing the critical temperature T C and finally leading to a superconductor-to-insulator transition. Here, this allows one to pattern narrow insulating regions with a focused ion beam (FIB) and thus fabricate nanoscale Josephson junctions on YBCO films. Moreover, such ion irradiation is known to cause structural changes in the YBCO film. However, details of how these structural changes occur in nanoscale devices produced by FIB remain unknown. Using nanofocus X-ray diffraction, we study the changes in the YBCO crystal lattice and investigate how the nature of these changes depends on the size of the irradiated regions. These data provide an important understanding of how oxide superconductors can be tailored at the nanometer scale for various applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Three-Dimensional Free Gas Flow Focuses Basin-Wide Microbial Methane to Concentrated Methane Hydrate Reservoirs in Geological System

Here, we present a systematic model that links the generation, migration, phase partitioning, and accumulation of methane into a closed loop as the sediment is deposited from the seafloor and buried through the base of hydrate stability zone (BHSZ). In our model, methane is generated by biodegradation of organic carbon in muds. Hydrate does not form and methane is not trapped until a coarse-grained layer is deposited, because the small pores prevent hydrate formation in muds. Instead, methane diffuses into sands/silts where methane solidifies into hydrate. As hydrate-bearing sands/silts pass through the BHSZ during sediment burial, methane hydrate dissociates, and releases free gas. The released and the newly generated free gas below the BHSZ concentrates into a vertical/dipping zone with low capillary entry pressure and high permeability and flows upward driven its buoyancy. When free gas reaches the hydrate stability zone (HSZ), capillary forces drive free gas to flow laterally, preferentially enter sands/silts, feed hydrate growth, and elevate hydrate saturation. With three-dimensional focused free gas flow, microbial methane that is generated from a much larger fetch area of the entire basin, both above and below the BHSZ, is concentrated into coarse-grained layers at structural closures for hydrate formation. Our model illustrates how geological evolution, microbial methane generation, and gas flow by buoyancy couple to generate concentrated hydrate deposits in geological system. These insights can be used to explore for high-concentration methane hydrate and are important for understanding the methane budget and carbon cycle under the seafloor.

58 GEOSCIENCES↗

Spot size measurement of a deuterium–tritium dense plasma focus using neutron radiography

Neutron radiography is a technique uniquely suited to applications in nuclear diagnostics, non-destructive testing, and subcritical experiments. The spatial resolution of neutron radiographs is degraded by optical blur in the imaging system and the neutron source size, where the ideal source is point-like to optimize the point-spread function. A potential neutron source for radiography is the dense plasma focus (DPF), a coaxial Z-pinch that produces thermonuclear and beam-target neutrons. To assess if the source size is suitable for radiography, a neutron imaging system was used to measure the source size of the 4 MA Sodium DPF at the Nevada National Security Site operating with deuterium–tritium gas-fill. The source size was measured using the edge-spread function of tungsten objects, each having a rolled (convex) edge. The spot size was found to be 7–12 mm full-width at half-max (FWHM) assuming a Gaussian source, though comparison is presented for Lorentzian and Bennett distributions. The average FWHM was found to be 8.6 ± 1.2 mm vertically and 10.8 ± 1.2 mm horizontally with respect to the image plane, averaging over varied edges and alignments. The results were sensitive to source alignment and edge metrology, which introduced notable uncertainties. These results are consistent with separate experimental measurements as well as magnetohydrodynamics simulations of this DPF, which suggest that neutron production can originate from pinches ∼5–7 mm off-axis. These results suggest that the DPF should be used for radiography at low magnification (M < 1) where spot size does not dominate spatial blur.

47 OTHER INSTRUMENTATION↗

Design and evaluation of an open-source, conformable skin-cooling system for body magnetic resonance guided focused ultrasound treatments

Magnetic resonance guided focused ultrasound (MRgFUS) treatment of tumors uses inter-sonication delays to allow heat to dissipate from the skin and other near-field tissues. Despite inter-sonication delays, treatment of tumors close to the skin risks skin burns. This work has designed and evaluated an open-source, conformable, skin-cooling system for body MRgFUS treatments to reduce skin burns and enable ablation closer to the skin. A MR-compatible skin cooling system is described that features a conformable skin-cooling pad assembly with feedback control allowing continuous flow and pressure maintenance during the procedure. System performance was evaluated with hydrophone, phantom and in vivo porcine studies. Sonications were performed 10 and 5 mm from the skin surface under both control and forced convective skin-cooling conditions. 3D MR temperature imaging was acquired in real time and the accumulated thermal dose volume was measured. Gross analysis of the skin post-sonication was further performed. Device conformability was demonstrated at several body locations. Hydrophone studies demonstrated no beam aberration, but a 5–12% reduction of the peak pressure due to the presence of the skin-cooling pad assembly in the acoustic near field. Phantom evaluation demonstrated there is no MR temperature imaging precision reduction or any other artifacts present due to the coolant flow during MRgFUS sonication. The porcine studies demonstrated skin burns were reduced in size or eliminated when compared to the control condition. An open-source design of an MRgFUS active skin cooling system demonstrates device conformability with a reduction of skin burns while ablating superficial tissues.

60 APPLIED LIFE SCIENCES↗

Plasma Focused Ion Beam Milling of High-Aspect-Ratio Holes in Diamond

Plasma focused ion beam (PFIB) technology has a great potential for applications requiring rapid micro-machining of high-aspect-ratio features. Here, we use 30-keV Ar, Xe, and O 2 ion beams to study PFIB milling of high-aspect-ratio circular holes in polycrystalline diamond. Our results show that Xe and O 2 ion beams have the highest milling efficiency for low-aspect-ratio and high-aspect-ratio hole milling, respectively. Each ion beam species produces holes with its characteristic shape and wall surface morphology. In conclusion, based on these results, we demonstrate a “hybrid” hole milled in a two-step process with Xe and O 2 ion beams with the geometry and wall morphology attractive for the attachment of a fuel fill tube to the inertial confinement fusion capsule.

ICF targets↗

Electronic angle focusing for neutron time-of-flight powder diffractometers

A neutron time-of-flight (TOF) powder diffractometer with a continuous wide-angle array of detectors can be electronically focused to make a single pseudo-constant wavelength diffraction pattern, thus facilitating angle-dependent intensity corrections. The resulting powder diffraction peak profiles are affected by the neutron source emission profile and resemble the function currently used for TOF diffraction.

electronic focusing↗

Mirror-centered representation of a focusing hyperbolic mirror for X-ray beamlines

Conic sections are commonly used in reflective X-ray optics. Hyperbolic mirrors can focus a converging light source and are frequently paired with elliptical or parabolic mirrors in Wolter type configurations. This paper derives the closed-form expression for a mirror-centered hyperbolic shape, with zero-slope at the origin. Combined with the slope and curvature, such an expression facilitates metrology, manufacturing and mirror-bending calculations. Previous works consider ellipses, parabolas, magnifying hyperbolas or employ lengthy approximations. Here, the exact shape function is given in terms of the mirror incidence angle and the source and image distances.

47 OTHER INSTRUMENTATION↗

Comparison of Single-Event Transients in an Epitaxial Silicon Diode Resulting from Heavy Ion-, Focused X-Ray-, and Pulsed Laser-Induced Charge Generation

Heavy ion, focused x-ray, and pulsed laser single event transient experiments are performed on a silicon epitaxial diode. Collected charge, transient rise times, and transient fall times are calculated and compared between the different sources. It is observed that these transient shape characteristics depend on the source (ion, x-ray, or laser), even when similar amounts of charge are generated. Finally, the observed differences are examined and explained in terms of basic charge collection mechanisms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First Experiments and Radiographs on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) Dense Plasma Focus

We report a dense plasma focus (DPF) is a relatively compact coaxial plasma gun, which completes its discharge as a Z-pinch. These devices are designed to operate at a variety of scales to produce short (<100 ns) pulses of ions, X-rays, and/or neutrons. LLNL recently constructed and brought into operation a new device, the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF, which is designed for radiography and high-yield operations. This device has been commissioned and has achieved neutron yields of up to 3.8E11 neutrons/pulse at 2.5-MA peak current while operating at up to 1 MJ of stored energy in its original pulsed power configuration. MJOLNIR is equipped with a wide range of diagnostics, including nuclear activation detectors, neutron time-of-flight (nToF) detectors, a fast-framing camera, optical light gates, and a time-gated neutron and X-ray imager. LLNL also runs unique particle-in-cell (PIC) simulations of DPF discharges in the Chicago code and has gained significant insight into the various physical factors that influence neutron yield. MJOLNIR is one of the first DPFs whose design and continual upgrades are heavily influenced by model predictions. In this article, we describe insights from modeling, device operation, and recent results. Comparisons between modeling predictions and measurements, as well as X-ray and neutron images are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗