Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FURNACES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Comparison of the combustion reactivity of TGA and drop tube furnace chars from a bituminous coal

This paper compares the reactivity of chars generated in a drop tube furnace (DTF) to those from TGA. The implications of devolatilization temperature, heating rate and residence time are considered. For the smaller particle size ranges of the bituminous coal investigated (ATC), optimized devolatilization procedures were used to generate corresponding TGA burnout rates between the two char types. However, with fractions of >75 {mu}m, the DTF chars showed an increased burnout propensity when moving from combustion regime II to combustion regime III. Scanning electron microscope (SEM) images and internal surface areas indicate that this is because of incompatible char morphologies. Thus, while chars produced under the conditions of TGA pyrolysis strongly resemble raw coal and display an undeveloped pore network; the DTF chars are highly porous, extensively swollen and possess considerably larger internal surface areas. Subsequently, char burnout variability was quantified, with the reactivity distribution for the DTF samples found to be up to an order of magnitude more significant than for the TGA chars. This is attributed to a fluctuating devolatilization environment on the DTF. Finally, a TGA study observed a robust particle size based compensation effect for the TGA chars, with the relative reaction rates and activation energies demonstrating the presence of internal diffusion control. However this phenomenon was partly alleviated for the DTF chars, since their higher porosities reduce mass transfer restrictions. Moreover, it should be realized that DTF char fractions of <38 {mu}m, including those required to ensure true intrinsic control under the investigated burnout conditions, cannot be produced directly. This is because of bridging and sloughing in the DTF's screw-feeder. Instead, such samples must be created by grinding larger particles, which destroys the char's existing porosity. 60 refs., 9 figs., 5 tabs.

01 COAL, LIGNITE, AND PEAT↗

Kinetics of the reaction of iron blast furnace slag/hydrated lime sorbents with SO{sub 2} at low temperatures: effects of the presence of CO{sub 2}, O{sub 2}, and NOx

The effects of the presence of CO{sub 2}, O{sub 2}, and NOx in the flue gas on the kinetics of the sulfation of blast furnace slag/hydrated lime sorbents at low temperatures were studied using a differential fixed-bed reactor. When O{sub 2} and NOx were not present simultaneously, the reaction kinetics was about the same as that under the gas mixtures containing SO{sub 2}, H{sub 2}O, and N{sub 2} only, being affected mainly by the relative humidity. The sulfation of sorbents can be described by the surface coverage model and the model equations derived for the latter case. When both O{sub 2} and NOx, were present, the sulfation of sorbents was greatly enhanced, forming a great amount of sulfate in addition to sulfite. The surface coverage model is still valid in this case, but the model equations obtained show a more marked effect of relative humidity and negligible effects of SO{sub 2} concentration and temperature on the reaction. The effect of sorbent composition on the reaction kinetics was entirely represented by the effects of the initial specific surface area (S{sub g0}) and the Ca molar content (M{sup -1}) of sorbent. The initial conversion rate of sorbent increased linearly with increasing S{sub g0}, and the ultimate conversion increased linearly with increasing S{sub g0}M{sup -1}. The model equations obtained in this work are applicable to describe the kinetics of the sulfation of the sorbents in the low-temperature dry and semidry fine gas desulfurization processes either with an upstream NOx, removal unit or without.111

01 COAL, LIGNITE, AND PEAT↗

Fabrication of Ultra-Shallow Junctions on 300 mm Wafers Using the Plasma Immersion Implanter PULSION registered Followed by Spike Annealing Using LEVITOR Furnace

Thanks to the European Project SEA-NET, an industrial version of the IBS Plasma Ion Implantation tool has been installed in LETI for the fabrication of Ultra-Shallow Junction for 45 and 32 nm CMOS on 200 and 300 mm wafers. In this study, we present first doping results on 300 mm wafers using BF{sub 3} plasma. Annealing after PULSION implantation is performed by the ASM furnace LEVITOR. This tool, which works on conduction heating is emissivity independent for temperature control and allows reaching high ramp up and ramp down speeds (up to 900 deg. C/s). Main characteristics of as implanted wafers are presented (metal contamination 2E10/cm{sup 2}, SIMS depth profiles down to 5 nm). Then the effect of convection gas in the annealing process on sheet resistance, junction depth and uniformity is presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of mass attenuation coefficients and effective atomic numbers of bismuth-ground granulated blast furnace slag concretes

Five samples of Bismuth-Ground granulated blast furnace slag (Bi-GGBFS) concretes were prepared using composition (0.6 cement + x Bi{sub 2}O{sub 3} + (0.4-x) GGBFS, x = 0.05, 0.10, 0.15, 0.20 and 0.25) by keeping constant water (W) cement (C) ratio. Mass attenuation coefficients (μ{sub m}) of these prepared samples were calculated using a computer program winXCOM at different gamma ray energies, whereas effective atomic numbers (Z{sub eff}) is calculated using mathematical formulas. The radiation shielding properties of Bi-GGBFS concrete has been compared with standard radiation shielding concretes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reduction of furnace temperature in ultra long carbon nanotube growth by plasmonic excitation of electron Fermi gas of catalytic nanocluster

In this paper, a novel physical method is presented to reduce the temperature of the furnace and prevent loss of thermal energy in ultra long carbon nanotube (CNT) growth process by catalytic chemical vapor deposition. This method is based on the plasmonic excitation of electron Fermi gas of catalytic nanocluster sitting at tip end of CNT by ultraviolet (UV) irradiation. Physical concepts of the method are explained in detail. The results of applying the presented method consequences to an appropriate tip-growth mechanism of the ultra long CNTs show that, in the presence of plasmonic excitation, the growth rate of the CNT is enhanced. Demonstration of temperature reduction and simultaneous increase in CNT length by UV irradiation with the proper frequency are the most important and practical result of the paper. All results are interpreted and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling and experiments for heat transfer process in pulverized coal-firing furnace with two-dimensional radiation characteristics

A dimension-reducing method for calculating the radiant heat transfer with two-dimensional characteristics is introduced in this article. Using this dimension-reducing method, the two-dimensional discrete transfer method (DTM) was applied to a cylindrical enclosure where the medium was absorptive and emissive. The two-dimensional DTM was proved to produce equivalent prediction results as the three-dimensional radiation computation. Then the two-dimensional DTM was incorporated into a general pulverized coal combustion model to estimate radiant heat transfer. The temperature distribution and the net heat flux distribution of an axisymmetric pilot furnace, in which three kinds of lignite were burned, respectively, were calculated using the comprehensive model. The prediction using this model has been found to have a high agreement with the measured data, that the temperature errors was at 5% and the net heat flux error was at about 15%. The results have demonstrated the feasibility and potential of using the two-dimensional DTM for radiation modeling in pulverized coal flame, and confirmed that the dimension-reducing method and the overall model will be simple and convenient for engineers to use.

01 COAL, LIGNITE, AND PEAT↗

Data-Driven Nonlinear Subspace Modeling for Prediction and Control of Molten Iron Quality Indices in Blast Furnace Ironmaking

Blast furnace (BF) in ironmaking is a nonlinear dynamic process with complicated physical-chemical reactions, where multi-phase and multi-field coupling and large time delay occur during its operation. In BF operation, the molten iron temperature (MIT) as well as Si, P and S contents of molten iron are the most essential molten iron quality (MIQ) indices, whose measurement, modeling and control have always been important issues in metallurgic engineering and automation field. This paper develops a novel data-driven nonlinear state space modeling for the prediction and control of multivariate MIQ indices by integrating hybrid modeling and control techniques. First, to improve modeling efficiency, a data-driven hybrid method combining canonical correlation analysis and correlation analysis is proposed to identify the most influential controllable variables as the modeling inputs from multitudinous factors would affect the MIQ indices. Then, a Hammerstein model for the prediction of MIQ indices is established using the LS-SVM based nonlinear subspace identification method. Such a model is further simplified by using piecewise cubic Hermite interpolating polynomial method to fit the complex nonlinear kernel function. Compared to the original Hammerstein model, this simplified model can not only significantly reduce the computational complexity, but also has almost the same reliability and accuracy for a stable prediction of MIQ indices. Last, in order to verify the practicability of the developed model, it is applied in designing a genetic algorithm based nonlinear predictive controller for multivariate MIQ indices by directly taking the established model as a predictor. Industrial experiments show the advantages and effectiveness of the proposed approach.

Blast furnace (BF)↗

Robust Online Sequential RVFLNs for Data Modeling of Dynamic Time-Varying Systems with Application of an Ironmaking Blast Furnace

In a world where the increasing complexity of modern industrial processes brings difficulties for accurate mathematical modeling, taking advantage of data has become an efficient solution to complex dynamic process modeling issue. In this paper, we develop a novel robust online sequential version of random vector functional-link networks (RVFLNs) for data-driven modeling of dynamic time-varying system and applied it in a blast furnace (BF) ironmaking process. First, to overcome the time-varying dynamics of process and to enable the RVFLNs to learn online with avoiding data saturation, an improved online sequential version of RVFLNs (OS-RFVLNs) is first presented by online sequential learning with forgetting factor. This improved OS-RVFLNs algorithm is not only suitable for the real-time and large data transfer situation, but also can adjust the sensitivity of the algorithm to different samples with the help of the introduced forgetting factor. Second, since the output weights of the improved OS-RVFLNs as well as other RVFLNs algorithms are obtained by the least squares approach, a robustness problem may occur when the training dataset is contaminated with various outliers. To solve this problem, a Cauchy distribution weighted M-estimator is introduced to improve the robustness of the improved OS- RVFLNs. For this proposed robust OS-RVFLNs (R-OS- RVFLNs), since the weights of different outlier data are properly determined by the Cauchy distribution function, their corresponding contribution on modeling can be properly distinguished. Thus robust and better modeling results can be achieved. Experiments using actual industrial data of BF ironmaking process and comparative studies have demonstrated that the proposed method produces a better estimation accuracy and stronger robustness than other methods.

Blast furnace (BF), Modelling, Dynamic systems↗

Data-Driven Robust RVFLNs Modeling of a Blast Furnace Iron-Making Process Using Cauchy Distribution Weighted M-Estimation

Optimal operation of a practical blast furnace (BF) ironmaking process depends largely on a good measurement of molten iron quality (MIQ) indices. However, measuring the MIQ online is not feasible using the available techniques. In this paper, a novel data-driven robust modeling is proposed for online estimation of MIQ using improved random vector functional-link networks (RVFLNs). Since the output weights of traditional RVFLNs are obtained by the least squares approach, a robustness problem may occur when the training dataset is contaminated with outliers. This affects the modeling accuracy of RVFLNs. To solve this problem, a Cauchy distribution weighted M-estimation based robust RFVLNs is proposed. Since the weights of different outlier data are properly determined by the Cauchy distribution, their corresponding contribution on modeling can be properly distinguished. Thus robust and better modeling results can be achieved. Moreover, given that the BF is a complex nonlinear system with numerous coupling variables, the data-driven canonical correlation analysis is employed to identify the most influential components from multitudinous factors that affect the MIQ indices to reduce the model dimension. Finally, experiments using industrial data and comparative studies have demonstrated that the obtained model produces a better modeling and estimating accuracy and stronger robustness than other modeling methods.

42 ENGINEERING↗

Hydronic Heating Coil Versus Propane Furnace, Rehoboth Beach, Delaware (Fact Sheet)

Insight Homes constructed two houses in Rehoboth Beach, Delaware, with identical floor plans and thermal envelopes but different heating and domestic hot water (DHW) systems. Each house is 1,715-ft 2 with a single story, three bedrooms, two bathrooms, and the heating, ventilation, and air conditioning (HVAC) systems and ductwork located in conditioned crawlspaces. The standard house, which the builder offers as its standard production house, uses an air source heat pump (ASHP) with supplemental propane furnace heating. The Building America test house uses the same ASHP unit with supplemental heat provided by the DHW heater (a combined DHW and hydronic heating system, where the hydronic heating element is in the air handler). Both houses were occupied during the test period. Results indicate that efficiency of the two heating systems was not significantly different. Three issues dominate these results; lower system design performance resulting from the indoor refrigerant coil selected for the standard house, an incorrectly functioning defrost cycle in the standard house, and the low resolution of the natural gas monitoring equipment. The thermal comfort of both houses fell outside the ASHRAE Standard 55 heating range but was within the ACCA room-to-room temperature range when compared to the thermostat temperature. The monitored DHW draw schedules were input into EnergyPlus to evaluate the efficiency of the tankless hot water heater model using the two monitored profiles and the Building America House Simulation Protocols. The results indicate that the simulation is not significantly impacted by the draw profiles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Retrofit Variable-Speed Furnace Fan Motors

In conjunction with the New York State Energy Research and Development Authority (NYSERDA) and Proctor Engineering Group, Ltd. (PEG), the Consortium for Advanced Residential Buildings (CARB) has evaluated the Concept 3 (tm) replacement motors for residential furnaces. These brushless, permanent magnet (BPM) motors can use much less electricity than their PSC (permanent split capacitor) predecessors. This evaluation focuses on existing homes in the heating-dominated climate of upstate New York with the goals of characterizing field performance and cost-effectiveness. The results of this study are intended to be useful to home performance contractors, HVAC contractors, and home efficiency program stakeholders. The project includes eight homes in and near Syracuse, NY. Tests and monitoring was performed both before and after fan motors were replaced. Average fan power reductions were approximately 126 Watts during heating and 220 Watts during cooling operation. Over the course of entire heating and cooling seasons, these translated into average electric energy savings of 163 kWh. Average cost savings were $20 per year. Homes where the fan was used outside of heating and cooling mode saved an additional $42 per year on average. Results indicate that BPM replacement motors will be most cost-effective in HVAC systems with longer run times and relatively low duct static pressures. More dramatic savings are possible if occupants use the fan-only setting when there is no thermal load. There are millions of cold-climate, U.S. homes that meet these criteria, but the savings in most homes tested in this study were modest.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Alternate Reductant Cold Cap Evaluation Furnace Phase II Testing

Savannah River Remediation (SRR) conducted a Systems Engineering Evaluation (SEE) to determine the optimum alternate reductant flowsheet for the Defense Waste Processing Facility (DWPF). Specifically, two proposed flowsheets (nitric–formic–glycolic and nitric–formic–sugar) were evaluated based upon results from preliminary testing. Comparison of the two flowsheets among evaluation criteria indicated a preference towards the nitric–formic–glycolic flowsheet. Further research and development of this flowsheet eliminated the formic acid, and as a result, the nitric–glycolic flowsheet was recommended for further testing. Based on the development of a roadmap for the nitric–glycolic acid flowsheet, Waste Solidification Engineering (WS-E) issued a Technical Task Request (TTR) to address flammability issues that may impact the implementation of this flowsheet. Melter testing was requested in order to define the DWPF flammability envelope for the nitric-glycolic acid flowsheet. The Savannah River National Laboratory (SRNL) Cold Cap Evaluation Furnace (CEF), a 1/12 th scale DWPF melter, was selected by the SRR Alternate Reductant project team as the melter platform for this testing. The overall scope was divided into the following sub-tasks as discussed in the Task Technical and Quality Assurance Plan (TTQAP): Phase I - A nitric–formic acid flowsheet melter test (unbubbled) to baseline the CEF cold cap and vapor space data to the benchmark melter flammability models; Phase II - A nitric–glycolic acid flowsheet melter test (unbubbled and bubbled) to: Define new cold cap reactions and global kinetic parameters in support of the melter flammability model development; Quantify off-gas surging potential of the feed; Characterize off-gas condensate for complete organic and inorganic carbon species. After charging the CEF with cullet from Phase I CEF testing, the melter was slurry-fed with glycolic flowsheet based SB6-Frit 418 melter feed at 36% waste loading and was operated continuously for 25 days. Process data was collected throughout testing and included melter operation parameters and off-gas chemistry. In order to generate off-gas data in support of the flammability model development for the nitric-glycolic flowsheet, vapor space steady state testing in the range of ~300-750°C was conducted under the following conditions, (i) 100% (nominal and excess antifoam levels) and 125% stoichiometry feed and (ii) with and without argon bubbling. Adjustments to feed rate, heater outputs and purge air flow were necessary in order to achieve vapor space temperatures in this range. Surge testing was also completed under nominal conditions for four days with argon bubbling and one day without argon bubbling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Retrofit Variable-Speed Furnace Fan Motors

In conjunction with the New York State Energy Research and Development Authority (NYSERDA) and Proctor Engineering Group, Ltd. (PEG), the Consortium for Advanced Residential Buildings (CARB) has evaluated the Concept 3™ replacement motors for residential furnaces. These brushless, permanent magnet (BPM) motors can use much less electricity than their PSC (permanent split capacitor) predecessors. This evaluation focuses on existing homes in the heating-dominated climate of upstate New York with the goals of characterizing field performance and cost effectiveness. The project includes eight homes in and near Syracuse, NY. Tests and monitoring was performed both before and after fan motors were replaced. Results indicate that BPM replacement motors will be most cost effective in HVAC systems with longer run times and relatively low duct static pressures. More dramatic savings are possible if occupants use the fan-only setting when there is no thermal load. There are millions of cold-climate, U.S. homes that meet these criteria, but the savings in most homes tested in this study were modest.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Research, Development and Field Testing of ThermoChemical Recuperation (TCR) for High Temperature Furnaces in the Steel Industry

Gas Technology Institute (GTI) evaluated the technical and economic feasibility of utilizing a non-catalytic ThermoChemical Recuperation System (TCRS) to recover a significant amount of energy from the waste gases of natural gas fired steel reheat furnaces. The project was related to DOE-AMO’s (formerly known as ITP) one of the technical areas of interest: Technologies to improve energy efficiency and reduce the carbon footprint of equipment currently used in energy-intensive industries such as iron and steel , and reduce by at least 30% energy consumption and carbon dioxide emission compared to the conventional technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Blast furnace slag reactions in various solutions (Interim Report)

Blast furnace slag (BPS) is a critical component of grout formulations for the remediation of low activity nuclear waste. This interim report describes the initial results of a study designed to investigate the fundamental mechanisms of BPS dissolution. The goal of the work is to delineate the physicochemical aspects of the slag that impart beneficial properties to grout formulations to enable the consistent production of a slag-replacement material (“designer slag”) that performs better than what is commercially available. This report documents the dissolution experiments that were conducted using nine different initial solution compositions. Solution measurements for each solution, including pH and solution composition, are given for 1, 7, 14, 28, and 56 day intervals samples. Scanning electron microscopy images are presented for the 56 day samples from each of the solutions. Inferences about reaction mechanisms and 56-day mineralogy are made based on the information collected to date. Some conclusions are made based on the work performed for this interim report, and a path forward including the strategy for making stronger conclusions based on X-ray diffraction (XRD) analyses is presented.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enabling Production of Low Carbon Emissions Steel through CO 2 Capture from Blast Furnace Gases at Cleveland Cliffs’ 5 mtpa Steel Plant at Burns Harbor, Indiana

Dastur International Inc. has prepared a DOE-funded Pre-front-end engineering design (Pre-FEED) study to capture up to 2.8 mtpa of CO 2 from the available Blast Furnace (BF) gases at the Burns Harbor steel plant operated by Cleveland Cliffs in Burns Harbor, Indiana. The project consists of an amine solvent based pre-combustion carbon capture system, along with a unique BF gas conditioning process which significantly optimizes the project design and architecture in terms of higher volumes (2.8 mtpa vis-à-vis 1.6 mtpa without conditioning) & concentration (32 vol% in conditioned gas vs. 22% in raw BF gas) of CO 2 , which can be captured using a single train, resulting in reduced size and capital cost of the CO 2 capture island, and improved overall economics on a $\$$/tCO 2 captured basis.

42 ENGINEERING↗

Characteristic Features of the Energy Modes of a Large Solar Furnace with a Capacity of 1000 kW

The possible energy characteristics of the LSF (large solar furnace with a capacity 1000 kW) based on numerical calculations are analyzed. The technical characteristics of the LSF are presented. The energy characteristics of the total system with different inaccuracies of the reflecting surfaces, energy contributions of certain shelves and groups of heliostats, and the contributions of certain heliostats and shapes of their focal spot are determined. Empirical formulas are proposed to describe the obtained numerical results. The problem of implementing the possible energy modes of the LSF with and/or without the inclusion of certain shelves and groups of heliostats is analyzed. The problem of a change in the energy density distribution in the focal spot of the LSF during the day is considered.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗