Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FUNDAMENTAL INTERACTIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

β -Nuclear-Recoil Correlation from $^6$$\mathrm{He}$ Decay in a Laser Trap

Here, we report the first precise measurement of a β-recoil correlation from a radioactive noble gas ( 6 He) confined via a magneto-optical trap. The measurement is motivated by the search for exotic tensor-type contributions to the charged weak current. Interpreted as tensor currents with right-handed neutrinos, the measurements yield |C T /C A | 2 ≤ 0.022 (90% confidence limit, C.L.). On the other hand, for left-handed neutrinos the limits are 0.007 < C T /C A < 0.111 (90% C.L.). The sensitivity of the present measurement is mainly limited by experimental uncertainties in determining the time response properties and the distance between the atom cloud and the microchannel plate used for recoil ion detection.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved Tensor Current Limit from 8 B 𝛽 Decay Including New Recoil-Order Calculations

A precision measurement of the 𝛽 + decay of 8 B was performed using the Beta-decay Paul Trap to determine the 𝛽−𝜈 angular correlation coefficient 𝑎 𝛽⁢𝜈 . The experimental results were combined with new ab initio symmetry-adapted no-core shell-model calculations to yield the second-most precise measurement from Gamow-Teller decays, 𝑎 𝛽⁢𝜈 = −0.3345 ± 0.001⁢9 stat ± 0.002⁢1 syst . This value agrees with the standard model value of −1/3 and improves uncertainties in 8 B by nearly a factor of 2. By combining results from 8 B and 8 Li , a tight limit on tensor current coupling to right-handed neutrinos was obtained. A recent global evaluation of all other precision 𝛽 decay studies suggested a nonzero value for right-handed neutrino coupling in contradiction with the standard model at just above 3⁢𝜎. Finally, the present results are of comparable sensitivity and do not support this finding.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Field Theory of the Fermi Function

The Fermi function F ( Z , E ) accounts for QED corrections to beta decays that are enhanced at either small electron velocity β or large nuclear charge Z . For precision applications, the Fermi function must be combined with other radiative corrections and with scale- and scheme-dependent hadronic matrix elements. We formulate the Fermi function as a field theory object and present a new factorization formula for QED radiative corrections to beta decays. We provide new results for the anomalous dimension of the corresponding effective operator complete through three loops, and resum perturbative logarithms and π enhancements with renormalization-group methods. Our results are important for tests of fundamental physics with precision beta decay and related processes. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Discovery of multimechanisms of screw dislocation interaction in bcc iron from open-ended saddle point searches

Dislocation motion and interactions determine mechanical properties in body-centered cubic (bcc) metallic materials. However, studying mechanisms for the screw dislocation interaction is fundamentally challenging since many underlying processes involve mesotimescales and atomistic resolution, currently inaccessible by either experimental techniques or continuum theoretical methods. Here, in this paper, we develop a computational capability based on self-evolving atomistic kinetic Monte Carlo (SEAKMC) to sample the critical events and saddle point energies related to screw dislocations and their junctions. The method is first validated by calculating the stress dependence of Peierls barriers and formation energies of kink pairs and cross-slip kink pairs on a single screw dislocation in bcc iron. Then the method is applied to a binary junction of a pair of intersecting screw dislocations, the structure of which is crucial for low-temperature plastic deformation. We identify three important mechanisms: coplanar cross-slipping, jog-pinning, and a previously unknown unzipping mechanism during the evolution of the binary junction. The mechanisms are then further validated using classical molecular dynamics simulations. The computational capability developed in this paper provides an effective tool to evaluate screw dislocation related thermally activated events in complex stress conditions. The mechanisms discovered in this paper provide critical insights into temperature dependence of the anomalous slip, a breakdown of the Schmidt law, during the plastic deformation in bcc iron and can be generalized to other bcc metals.

36 MATERIALS SCIENCE↗

Topological Rigidity and Non-Abelian Defect Junctions in Chiral Nematic Systems with Effective Biaxial Symmetry

We study topologically stable defect structures in systems where the defect line classification in three dimensions and associated algebra of interactions (the fundamental group) are governed by the non-Abelian eight-element group, the quaternions 𝑄 8 . The non-Abelian character of the defect algebra leads to a topological rigidity of bound defect pairs, and trivalent junctions which are the building blocks of multijunction trivalent networks. We realize such structures in laboratory chiral nematics and analyze their behavior analytically, along with numerical modeling.

Liquid crystals↗

Cosmological parameter estimation with a joint-likelihood analysis of the cosmic microwave background and big bang nucleosynthesis

Here, we present a joint-likelihood analysis of big bang nucleosynthesis (BBN) and cosmic microwave background (CMB) data, consistently combining likelihoods and taking into account uncertainties in nuclear reaction rates for the first time. Bayesian inference is performed on the baryon abundance and the effective number of neutrino species, 𝑁 eff , using a CMB Boltzmann solver in combination with LINX , a new flexible and efficient BBN code. We marginalize over Planck nuisance parameters and nuclear rates to find 𝑁 eff =3.0⁢8$^{+0.15}_{−0.14}$, 2.9⁢4$^{+0.16}_{−0.15}$, or 2.96$^{+0.13}_{−0.14}$, for three separate reaction networks. This framework enables robust testing of the lambda cold dark matter paradigm and its variants with CMB and BBN data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dosimetric validation of Acuros XB with Monte Carlo methods for photon dose calculations

Purpose: The dosimetric accuracy of the recently released Acuros XB advanced dose calculation algorithm (Varian Medical Systems, Palo Alto, CA) is investigated for single radiation fields incident on homogeneous and heterogeneous geometries, and a comparison is made to the analytical anisotropic algorithm (AAA). Methods: Ion chamber measurements for the 6 and 18 MV beams within a range of field sizes (from 4.0x4.0 to 30.0x30.0 cm{sup 2}) are used to validate Acuros XB dose calculations within a unit density phantom. The dosimetric accuracy of Acuros XB in the presence of lung, low-density lung, air, and bone is determined using BEAMnrc/DOSXYZnrc calculations as a benchmark. Calculations using the AAA are included for reference to a current superposition/convolution standard. Results: Basic open field tests in a homogeneous phantom reveal an Acuros XB agreement with measurement to within {+-}1.9% in the inner field region for all field sizes and energies. Calculations on a heterogeneous interface phantom were found to agree with Monte Carlo calculations to within {+-}2.0%({sigma}{sub MC}=0.8%) in lung ({rho}=0.24 g cm{sup -3}) and within {+-}2.9%({sigma}{sub MC}=0.8%) in low-density lung ({rho}=0.1 g cm{sup -3}). In comparison, differences of up to 10.2% and 17.5% in lung and low-density lung were observed in the equivalent AAA calculations. Acuros XB dose calculations performed on a phantom containing an air cavity ({rho}=0.001 g cm{sup -3}) were found to be within the range of {+-}1.5% to {+-}4.5% of the BEAMnrc/DOSXYZnrc calculated benchmark ({sigma}{sub MC}=0.8%) in the tissue above and below the air cavity. A comparison of Acuros XB dose calculations performed on a lung CT dataset with a BEAMnrc/DOSXYZnrc benchmark shows agreement within {+-}2%/2mm and indicates that the remaining differences are primarily a result of differences in physical material assignments within a CT dataset. Conclusions: By considering the fundamental particle interactions in matter based on theoretical interaction cross sections, the Acuros XB algorithm is capable of modeling radiotherapy dose deposition with accuracy only previously achievable with Monte Carlo techniques.

60 APPLIED LIFE SCIENCES↗

SU-C-207A-03: Development of Proton CT Imaging System Using Thick Scintillator and CCD Camera

Purpose: In the treatment planning of proton therapy, Water Equivalent Length (WEL), which is the parameter for the calculation of dose and the range of proton, is derived by X-ray CT (xCT) image and xCT-WEL conversion. However, about a few percent error in the accuracy of proton range calculation through this conversion has been reported. The purpose of this study is to construct a proton CT (pCT) imaging system for an evaluation of the error. Methods: The pCT imaging system was constructed with a thick scintillator and a cooled CCD camera, which acquires the two-dimensional image of integrated value of the scintillation light toward the beam direction. The pCT image is reconstructed by FBP method using a correction between the light intensity and residual range of proton beam. An experiment for the demonstration of this system was performed with 70-MeV proton beam provided by NIRS cyclotron. The pCT image of several objects reconstructed from the experimental data was evaluated quantitatively. Results: Three-dimensional pCT images of several objects were reconstructed experimentally. A finestructure of approximately 1 mm was clearly observed. The position resolution of pCT image was almost the same as that of xCT image. And the error of proton CT pixel value was up to 4%. The deterioration of image quality was caused mainly by the effect of multiple Coulomb scattering. Conclusion: We designed and constructed the pCT imaging system using a thick scintillator and a CCD camera. And the system was evaluated with the experiment by use of 70-MeV proton beam. Three-dimensional pCT images of several objects were acquired by the system. This work was supported by JST SENTAN Grant Number 13A1101 and JSPS KAKENHI Grant Number 15H04912.

60 APPLIED LIFE SCIENCES↗

SU-F-I-06: Evaluation of Imaging Dose for Modulation Layer Based Dual Energy Cone-Beam CT

Purpose: Dual energy cone beam CT system is finding a variety of promising applications in diagnostic CT, both in imaging of endogenous materials and exogenous materials across a range of body sites. Dual energy cone beam CT system to suggest in this study acquire image by rotating 360 degree with half of the X-ray window covered using copper modulation layer. In the region that covered by modulation layer absorb the low energy X-ray by modulation layer. Relative high energy X-ray passes through the layer and contributes to image reconstruction. Dose evaluation should be carried out in order to utilize such an imaging acquirement technology for clinical use. Methods: For evaluating imaging dose of modulation layer based dual energy cone beam CT system, Prototype cone beam CT that configured X-ray tube (D054SB, Toshiba, Japan) and detector (PaxScan 2520V, Varian Medical Systems, Palo Alto, CA) is used. A range of 0.5–2.0 mm thickness of modulation layer is implemented in Monte Carlo simulation (MCNPX, ver. 2.6.0, Los Alamos National Laboratory, USA) with half of X-ray window covered. In-house phantom using in this study that has 3 cylindrical phantoms configured water, Teflon air with PMMA covered for verifying the comparability the various material in human body and is implemented in Monte Carlo simulation. The actual dose with 2.0 mm copper covered half of X-ray window is measured using Gafchromic EBT3 film with 5.0 mm bolus for compared with simulative dose. Results: Dose in phantom reduced 33% by copper modulation layer of 2.0 mm. Scattering dose occurred in modulation layer by Compton scattering effect is 0.04% of overall dose. Conclusion: Modulation layer of that based dual energy cone beam CT has not influence on unnecessary scatter dose. This study was supported by the Radiation Safety Research Programs (1305033) through the Nuclear Safety and Security Commission.

60 APPLIED LIFE SCIENCES↗

SU-F-I-54: Spatial Resolution Studies in Proton CT Using a Phase-II Prototype Head Scanner

Purpose: To characterize the modulation transfer function (MTF) of the pre-clinical (phase II) head scanner developed for proton computed tomography (pCT) by the pCT collaboration. To evaluate the spatial resolution achievable by this system. Methods: Our phase II proton CT scanner prototype consists of two silicon telescopes that track individual protons upstream and downstream from a phantom, and a 5-stage scintillation detector that measures a combination of the residual energy and range of the proton. Residual energy is converted to water equivalent path length (WEPL) of the protons in the scanned object. The set of WEPL values and associated paths of protons passing through the object over a 360° angular scan is processed by an iterative parallelizable reconstruction algorithm that runs on GP-GPU hardware. A custom edge phantom composed of water-equivalent polymer and tissue-equivalent material inserts was constructed. The phantom was first simulated in Geant4 and then built to perform experimental beam tests with 200 MeV protons at the Northwestern Medicine Chicago Proton Center. The oversampling method was used to construct radial and azimuthal edge spread functions and modulation transfer functions. The spatial resolution was defined by the 10% point of the modulation transfer function in units of lp/cm. Results: The spatial resolution of the image was found to be strongly correlated with the radial position of the insert but independent of the relative stopping power of the insert. The spatial resolution varies between roughly 4 and 6 lp/cm in both the the radial and azimuthal directions depending on the radial displacement of the edge. Conclusion: The amount of image degradation due to our detector system is small compared with the effects of multiple Coulomb scattering, pixelation of the image and the reconstruction algorithm. Improvements in reconstruction will be made in order to achieve the theoretical limits of spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-630: Energy Spectral Study On Lipiodol After Trans-Arterial Chemoembolization Using the Flattened and Unflattened Photon Beams

Purpose: SBRT combining transarterial chemoembolization with Lipiodol is expected to improve local control. Our showed that the dose enhancement effect in the Lipiodol with 10X flattening filter free (FFF) was inserted. This study was to investigate the energy fluence variations of electron in the Lipiodol using flattened (FF) and FFF beams. Methods: FF and FFF for 6X and 10X beams by TrueBeam were used in this study. The Lipiodol (3 X 3 X 3 cm{sup 3}) was located at the depth of 5 cm in water, the dose enhancement factor (DEF) and energy fluence were calculated by Monte Carlo (MC) calculations (PHITS). Results: DEFs with FF and FFF of 6X were 17.1% and 24.3% at rebuild-up region in the Lipiodol (5.3cm depth), 7.0% and 17.0% at the center of Lipiodol (6.5cm depth), and −13.2% and −8.2% at behind Lipiodol (8.3cm depth). DEFs with FF and FFF of 10X were 21.7% and 15.3% at rebuild-up region, 8.2% and 10.5% at the center of Lipiodol, and −14.0% and −8.6% at behind Lipiodol. Spectral results showed that the FFF beam contained more low-energy (0–0.3MeV) component of electrons than FF beam, and FF beam contained more high-energy (over 0.3MeV) electrons than FFF beam in Lipiodol. Behind the Lipiodol, build-down effect with FF beam was larger than FFF beam because FF beam contained more high energy electrons. The difference of DEFs between FFF and FF beams for 6X were larger than for 10X. This is because 10X beam contained more high-energy electrons. Conclusion: It was found that the 6XFFF beam gives the largest change of energy fluence and the largest DEF in this study. These phenomena are mainly caused by component of low-energy electrons, and this energy is almost correspond to the boundary of photo electronic dominant and Compton scattering dominant region for photon beams.

60 APPLIED LIFE SCIENCES↗

Light-induced picosecond rotational disordering of the inorganic sublattice in hybrid perovskites

Femtosecond resolution electron scattering techniques are applied to resolve the first atomic-scale steps following absorption of a photon in the prototypical hybrid perovskite methylammonium lead iodide. Following above-gap photoexcitation, we directly resolve the transfer of energy from hot carriers to the lattice by recording changes in the mean square atomic displacements on 10-ps time scales. Measurements of the time-dependent pair distribution function show an unexpected broadening of the iodine-iodine correlation function while preserving the Pb-I distance. This indicates the formation of a rotationally disordered halide octahedral structure developing on picosecond time scales. Here, this work shows the important role of light-induced structural deformations within the inorganic sublattice in elucidating the unique optoelectronic functionality exhibited by hybrid perovskites and provides new understanding of hot carrier-lattice interactions, which fundamentally determine solar cell efficiencies.

36 MATERIALS SCIENCE↗

Spontaneous SU(2) symmetry violation in the SU(2){sub L} Multiplication-Sign SU(2){sub R} Multiplication-Sign SU(4) electroweak model

A new approach to electroweak (EW) composite scalars is developed starting from the fundamental gauge interaction on high scale. The latter is assumed to have the group structure SU(2){sub L} Multiplication-Sign SU(2){sub R} Multiplication-Sign SU(4), where SU(4) is the Pati-Salam color-lepton group. The topological EW vacuum filled by instantons is explicitly constructed and the resulting equations for fermion masses exhibit spontaneous SU(2) flavor symmetry violation with possibility of very large mass ratios.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Total cross sections for hadron collisions on the basis of the HPR1R2 model

The results of a quantitative, statistically complete, description of the total-cross-section data obtained worldwide for hadron–hadron (photon–hadron) collisions and compiled in the Particle Data Group surveys are presented for several versions of a universal analytic parametrization of amplitudes for forward hadron–hadron (photon-hadron) scattering.

74 ATOMIC AND MOLECULAR PHYSICS↗

Lepton decay constants of light mesons

A theory of lepton decay constants based on the path-integral formalism is given for chiral and vector mesons. Decay constants of the pseudoscalar and vector mesons are calculated and compared to other existing results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Conversations and deliberations: Non-standard cosmological epochs and expansion histories

Here, this paper summarizes the discussions which took place during the PITT-PACC Workshop entitled “Non-Standard Cosmological Epochs and Expansion Histories,” held in Pittsburgh, Pennsylvania, Sept. 5–7, 2024. Much like the non-standard cosmological epochs that were the subject of these discussions, the format of this workshop was also non-standard. Rather than consisting of a series of talks from participants, with each person presenting their own work, this workshop was instead organized around free-form discussion blocks, with each centered on a different overall theme and guided by a different set of Discussion Leaders. This document is not intended to serve as a comprehensive review of these topics, but rather as an informal record of the discussions that took place during the workshop, in the hope that the content and free-flowing spirit of these discussions may inspire new ideas and research directions.

cosmology↗