Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLUID INJECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Apparatus for characterizing the temporo-spatial properties of a dynamic fluid front and method thereof

Methods and apparatus are described for characterizing the temporal-spatial properties of a dynamic fluid front within a mold space while the mold space is being filled with fluid. A method includes providing a mold defining a mold space and having one or more openings into the mold space; heating a plurality of temperature sensors that extend into the mold space; injecting a fluid into the mold space through the openings, the fluid experiencing a dynamic fluid front while filling the mold space with the fluid; and characterizing temporal-spatial properties of the dynamic fluid front by monitoring a temperature of each of the plurality of heated temperature sensors while the mold space is being filled with the fluid. An apparatus includes a mold defining a mold space; one or more openings for introducing a fluid into the mold space and filling the mold space with the fluid, the fluid experiencing a dynamic fluid front while filling the mold space; a plurality of heated temperature sensors extending into the mold space; and a computer coupled to the plurality of heated temperature sensors for characterizing the temporal-spatial properties of the dynamic fluid front.

Battiste, Richard L↗

Diagnostic Cardiac Catheterization Using the MEDRAD Avanta™ Fluid Management System as Compared to the Traditional Manual Injection Method

Nearly 4 million patient procedures performed annually in US cardiac catheterization laboratories utilize contrast media to achieve vessel opacification. The amount of contrast media used is variable and depends on the complexity of the procedure, the method of contrast delivery as well as the skill-level of the operator. Since the total amount of contrast used for each procedure can have both patient safety and economic implications, it is essential for cardiologists to have the ability to control contrast delivery such that optimal angiographic image quality is achieved using the least amount of contrast. Although the complication rate associated with cardiac catheterization remains low, the most common serious complication, contrast-induced nephropathy (CIN), is associated with poor prognosis and a high mortality rate. Numerous interventional strategies for preventing and reducing the severity of CIN have demonstrated varying degrees of clinical benefit, but none has been shown to reliably prevent this serious complication. To date, the most effective approach for reducing the risk of CIN is to properly hydrate the patient and to minimize the amount of contrast media administered. Automated injection systems are intended for use in virtually all cardiac catheterization procedures and have numerous features which can provide potential advantages over traditional methods. With automated injection technology the operator is able to control and precisely monitor contrast delivery. Additionally, the MEDRAD Avanta Fluid Management Injection System utilizes a sterile contrast reservoir which eliminates the need to discard unused contrast in individual opened containers following each procedure. Considering that an average of 50% of opened contrast media is wasted using manual injection methods, this savings can provide a substantial economic benefit. Automated systems also facilitate the use of smaller (5 French) catheter sizes. Precise flow control and the use of smaller diameter catheters have both been shown to reduce the volume of contrast administered. The use of smaller size catheters also permits more rapid hemostasis, thus allowing shorter ambulation time without the need for costly wound closure devices. These factors can result in enhanced patient satisfaction as well as more efficient management of post-procedure rooms. The intent of this study was to demonstrate that using the MEDRAD Avanta™ Fluid Management Injection System (MEDRAD, INC., Pittsburgh, PA) for coronary diagnostic procedures can produce a reduction in the volume of contrast administered without loss of operational quality or efficiency. In addition, this study will explore procedure time and efficiency in an effort to minimize the amount of ionizing radiation delivered to the patient as well as the diagnostic team members. Study Design This is a post-market study designed to collect data during diagnostic cardiac catheterization when utilizing 5FR or 6FR catheters in conjunction with the Avanta Fluid Management System or a manual manifold injection method control group. A minimum of 420 patients scheduled for diagnostic cardiac catheterization will be enrolled in the study cohort. Patients will be assigned into the following two groups. Group 1: Catheterization with 5FR or 6FR catheters, using the traditional manual manifold injection method for contrast media delivery which is defined as manual hand injection of contrast media through a 3 or 4 port manifold and left ventriculography performed via standard fixed rate power injection. Group 2: Catheterization with 5FR or 6FR catheters, using the MEDRAD Avanta™ system for contrast media delivery. Study endpoints include volume of contrast media administered during diagnostic cardiac catheterization, volume of contrast media wasted post-procedure, procedure time (defined as the time from first catheter insertion to last diagnostic catheter removal), fluoroscopy time and angiographic image quality. The study demonstrated that use of the Advanta system reduced overall contrast utilization by decreasing the amount of contrast administered to the patient and reducing the amount of contrast wasted during preparation and post-procedure clean-up. The quality of the angiographic images and the radiation exposure to the patient were not affected.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of biogeochemistry in efficient shale oil and gas production

The advent and advancement in hydraulic fracturing techniques have resulted in the rapid growth of unconventional shale oil and gas production over the last couple of decades. Unlike conventional hydrocarbon systems, these shale formations serve as both the source and reservoir and therefore are directly drilled into for hydrocarbon production. Studies in different shale basins have revealed that these reservoirs are geologically complex, heterogeneous, and every play is unique. Therefore, for efficient hydrocarbon recovery, physicochemical, and mechanical attributes of individual shale reservoir need to be taken into account. Even after significant technological advancements, we are still struggling to understand the spatiotemporal variations in type and amount of hydrocarbon produced within a single basin, rapid declines in hydrocarbon production, and the low fracturing fluid recovery rates. In this review article, we briefly summarize how biogeochemical tools can be used to 1) understand variations in the quantity of organic matter (OM) that ultimately controls production of hydrocarbon, 2) determine variations in the quality of OM that ultimately controls the quality and type of hydrocarbons generated, 3) predict the fracturing potential of rock, and 4) increase efficiency of hydrocarbon production by controlling the water-rock-microbe interactions that ensue after hydraulic fracturing fluids are injected into the shale reservoirs. A better understanding and utilization of these biogeochemical processes and tools will help identify sweet spots for shale gas drilling, increase hydrocarbon recovery and open up the possibility of engineering the hydraulic fracturing fluids to enhance recovery and life of these shale reservoirs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Foam Delivery of Amendments for Vadose Zone Remediation – Propagation Performance in Unsaturated Sediments

Foam delivery of remedial amendments is potentially useful for vadose zone remediation because aqueous amendments are delivered while maintaining a low water content. The transport behavior of foam in the vadose zone is not well studied. Bench top scale column tests were conducted to investigate the foam transport, foaming gas and liquid propagation, pressure build up and distribution, influence of foam quality and sediment permeability on foam injection pressure, and liquid up-taking and distribution in sediments during foam flow in unsaturated sediments. Results indicated that under the unsaturated conditions, foaming gas front traveled much faster than the foam front where bubbles rupture was significant. A liquid front was formed ahead of the foam flow front. The accumulated liquid in this front was mainly composed of the water injected with foam. The foam injection pressure was mostly attributed to the resistance to foam flow from the sediment, but not to the movement of the water ahead of the foam front. Foam had a high effective viscosity compare to water. A near linear pressure distribution within the foam-occupied column section was observed. At fixed injection rate, higher foam quality resulted lower injection pressure. Higher permeability sediments did not necessarily have a lower foam injection pressure, as other factors such as the foam injection rate, foam bubble diameter, and sediment pore size also influenced the pressure. In the foam flushed region, the liquid uptake and the water content distribution in sediment was barely affected by the initial water content and the foam injection rate. The implications of these findings in field remediation application were discussed.

54 ENVIRONMENTAL SCIENCES↗

Simultaneous axial conduction in the fluid and the pipe wall for forced convective laminar flow with blowing and suction at the wall

Numerical solutions are reported for conjugate heat transfer in a porous pipe having an internal flow with blowing or suction at the inner surface of the pipe and constant heat flux at the outer surface. The effect of the simultaneous axial conduction through the wall and the fluid has been studied for the combined hydrodynamic and thermal entry lengths. The results show that the ratio of the thermal conductivities of the pipe wall to the fluid and the thickness of the pipe wall may become significant factors on the heat transfer when the Peclet number is small, especially for the case when fluid is injected into the pipe. It is also shown that the effect of axial wall conduction for the case of constant heat flux at the outer wall surface can be neglected when the wall thickness is small and the ratio of the conductivities of the wall to the fluid approaches unity.

Faghri, Amir↗

Surfactants are Ineffective for Reducing Imbibition of Water-Based Fracturing Fluids in Deep Gas Reservoirs

Minimizing loss of injected hydraulic fracturing fluids into shale along fracture-matrix boundaries is desired because imbibed water restricts gas production and wastes valuable water resources. This problem has motivated the addition of surfactants into water-based hydraulic fracturing fluids in order to reduce the capillary driving force for imbibition. Here, we show that reduction in interfacial tension and wettability alteration has negligible ability to reduce imbibition in deep gas reservoirs. The effectiveness of altering capillary forces acting at the wetting front also depends on the injection pressure acting at the fracture-matrix boundary. The pressure at the interface between the fracture and the shale matrix is constrained between the reservoir pore pressure and formation pressure (rock fracture pressure, also known as breakdown pressure of the rock) and increases with depth to magnitudes that greatly exceed that of capillary pressures. Furthermore, the analyses presented here show that even maximum alteration of interfacial properties that result in strongly hydrophobic interactions between the fracturing fluid and reservoir rock is incapable of significantly reducing imbibition in deep reservoirs. Instead of using surfactants, this analysis points to decreases in wellbore shut-in pressures and shut-in times as practical options for reducing imbibition losses of water-based fluids.

03 NATURAL GAS↗

Numerical study of proppant transport and settling processes in fractures

Reservoir stimulation by creating hydraulically conductive fractures is the key step for enabling enhanced geothermal systems (EGS). The effectiveness of stimulation is significantly influenced by the deposition of proppant inside induced fractures. The transportation and settling of proppant in a propagating fracture is controlled by a multitude of operational and physical parameters, including the fracturing fluid rheology, injection rate, proppant concentration, fracture length/aperture evolution, proppant size/density/shape, etc. A numerical tool that robustly and efficiently accounts for all important attributes can facilitate the design and optimization of reservoir stimulation. This study presents the novel computational tool ELK (ELectrical fracKing) developed for the numerical simulation of proppant-fluid mixture circulation in a fractured geothermal reservoir. We enriched the MOOSE-based PorousFlow module with a suite of equations to consider the fluid-proppant mixture with particle-particle/fluid interactions, which include gravitational settling, particle convection, particle hampering, and strong density and viscosity contrasts. The computational tool is validated by comparing the predicted proppant bed evolution against two different laboratory scale experiments of proppant transport in a fixed aperture channel. Further parameter studies were performed, and the modeling results show that the proppant deposition is determined by the mixing characteristics and settling of the particles from the slurry. Concentration-dependent density and viscosity lead to an inhomogeneous distribution of the proppant, particle collision, and enhanced settling at the bottom of the fractures. Preliminary coupling with dynamic fracture propagation shows promising results and will be further developed to simulate hydraulic stimulation at high fidelity.

15 GEOTHERMAL ENERGY↗

SILICA GEL BEHAVIOR UNDER DIFFERENT EGS CHEMICAL AND THERMAL CONDITIONS: AN EXPERIMENTAL STUDY

Fractures and fracture networks are the principal pathways for migration of water and contaminants in groundwater systems, fluids in enhanced geothermal systems (EGS), oil and gas in petroleum reservoirs, carbon dioxide leakage from geological carbon sequestration, and radioactive and toxic industrial wastes from underground storage repositories. When dealing with EGS fracture networks, there are several major issues to consider, e.g., the minimization of hydraulic short circuits and losses of injected geothermal fluid to the surrounding formation, which in turn maximize heat extraction and economic production. Gel deployments to direct and control fluid flow have been extensively and successfully used in the oil industry for enhanced oil recovery. However, to the best of our knowledge, gels have not been applied to EGS to enhance heat extraction. In-situ gelling systems can either be organic or inorganic. Organic polymer gels are generally not thermostable to the typical temperatures of EGS systems. Inorganic gels, such as colloidal silica gels, however, may be ideal blocking agents for EGS systems if suitable gelation times can be achieved. In the current study, we explore colloidal silica gelation times and rheology as a function of SiO{sub 2} concentration, pH, salt concentration, and temperature, with preliminary results in the two-phase field above 100 C. Results at 25 C show that it may be possible to choose formulations that will gel in a reasonable and predictable amount of time at the temperatures of EGS systems.

02 PETROLEUM↗

A Comparative Review of Hydrologic Issues Involved in Geologic Storage of CO2 and Injection Disposal of Liquid Waste

The paper presents a comparison of hydrologic issues and technical approaches used in deep-well injection and disposal of liquid wastes, and those issues and approaches associated with injection and storage of CO{sub 2} in deep brine formations. These comparisons have been discussed in nine areas: (1) Injection well integrity; (2) Abandoned well problems; (3) Buoyancy effects; (4) Multiphase flow effects; (5) Heterogeneity and flow channeling; (6) Multilayer isolation effects; (7) Caprock effectiveness and hydrogeomechanics; (8) Site characterization and monitoring; and (9) Effects of CO{sub 2} storage on groundwater resources There are considerable similarities, as well as significant differences. Scientifically and technically, these two fields can learn much from each other. The discussions presented in this paper should help to focus on the key scientific issues facing deep injection of fluids. A substantial but by no means exhaustive reference list has been provided for further studies into the subject.

54 ENVIRONMENTAL SCIENCES↗

Rare-earth neutral metal injection into an electron beam ion trap plasma

We have designed and implemented a neutral metal vapor injector on the SuperEBIT high-energy electron beam ion trap at the Lawrence Livermore National Laboratory. A horizontally directed vapor of a europium metal is created using a thermal evaporation technique. The metal vapor is then spatially collimated prior to injection into the trap. The source's form and quantity constraints are significantly reduced making plasmas out of metal with vapor pressures ≤10{sup −7} Torr at ≥1000 °C more obtainable. A long pulsed or constant feed metal vapor injection method adds new flexibility by varying the timing of injection and rate of material being introduced into the trap.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-Situ Stress Measurements at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) Site

A scientific injection campaign was conducted at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site in 2017 and 2019. The testing included pump-in/shut-in, pump-in/flowback, and step rate tests. Various methods have been employed to interpret the in-situ stress from the test dataset. This study focuses on methods to interpret the minimum in-situ stress from step rate, pump-in/extended shut-in tests data obtained during the stimulation of two zones in Well 58-32. This well was drilled in low-permeability granitoid. A temperature of 199 °C was recorded at the well’s total depth of 2297 m relative to the rotary Kelly bushing (RKB). The lower zone (Zone 1) consisted of 46 m of the openhole at the toe of the well. Fractures in the upper zone (Zone 2) were stimulated between 2123–2126 m measured depths (MD) behind the casing. The closure stress gradient variation depended on the depth and the injection chronology. The closure stress was found to increase with the pumping rate/volume. This stress variation could indicate that poroelastic effects (“back stress”) and the presence of adjacent natural fractures may play an important role in the interpretation of fracture closure stress. Further, progressively increasing local total stresses may, consequently, have practical applications when moderate volumes of fluid are injected in a naturally fractured or high-temperature reservoir. The alternative techniques that use pump-in/flowback tests and temperature signatures provide a valuable perspective view of the in-situ stress measurements.

15 GEOTHERMAL ENERGY↗

A Mathematical Model for the Multiphase Transport and Reaction Kinetics in a Ladle with Bottom Powder Injection

A computation fluid dynamics-population balance model-simultaneous reaction model (CFD-PBM-SRM) coupled model has been proposed to study the multiphase flow behavior and refining reaction kinetics in a ladle with bottom powder injection, and some new and important phenomena and mechanisms are presented. For the multiphase flow behavior, the effects of bubbly plume flow, powder particle motion, particle-particle collision and growth, particle-bubble collision and adhesion, and powder particle removal into top slag are considered. For the reaction kinetics, the mechanisms of multicomponent simultaneous reactions, including Al, S, Si, Mn, Fe, and O, at the multi-interface, including top slag-liquid steel interface, air-liquid steel interface, powder droplet-liquid steel interface, and bubble-liquid steel interface, are presented, and the effect of sulfur solubility in the powder droplet on the desulfurization is also taken into account. Model validation is carried out using hot tests in a 2-t induction furnace with bottom powder injection. The result shows that the powder particles gradually disperse in the entire furnace; in the vicinity of the bottom slot plugs, the desulfurization product CaS is liquid phase, while in the upper region of the furnace, the desulfurization product CaS is solid phase. The predicted sulfur contents by the present model agree well with the measured data in the 2-t furnace with bottom powder injection.

36 MATERIALS SCIENCE↗

Geochemical Assessment for Carbon Sequestration in the Conasauga Group, Northwest Georgia, USA

Sedimentary geological formations are known to be great candidates for geological carbon sequestration. Published studies suggest the southeast of the United States contains many formations suitable for carbon storage. The Cassville 1 Stratigraphic Borehole well could act as a potential carbon reservoir for nearby energy resource facilities in Georgia, United States. Although studies have shown that porous formations are adequate for geological carbon sequestration, it is important to understand possible geochemical reactions between CO 2 and the targeted geological formation before injecting any fluids. In this study, a sandstone sample from the Cassville 1 well is being considered for geological carbon sequestration in the Conasauga Group in Northwest Georgia. Here, the collected sandstone sample, consisting of quartz, K-feldspar, micas, kaolinite, and carbonate minerals such as calcite and dolomite, has a 6% porosity. Leveraging the formation composition and porosity, a one-dimensional continuum reactive transport model was built using CrunchFlow to assess possible geochemical reactions between injected CO 2 and the geological formation. Simulation results show that the carbonate minerals, calcite and dolomite, dissolve during the injection period of 10,000 days, increasing formation porosity from 6% to as much as 30%. The rate and extent of carbonate mineral dissolution and resulting porosity increase are highly sensitive to mineral reactive surface area values. No evidence of mineral precipitation was observed, suggesting that dissolution reactions will control porosity evolution during the CO 2 injection period.

42 ENGINEERING↗

Experiments and Modeling of Proppant Embedment and Fracture Conductivity for the Caney Shale, Oklahoma, USA

ABSTRACT: The ultimate aim of hydraulic fracturing is to have a long and conductive flow path that extends from the wellbore into the formation. The effective fracture length is part of a hydraulically propped fracture which contributes to production. The difficulty in achieving economical production targets from shale reservoirs is at the forefront in many exploration companies. Fracture conductivity loss is related to; proppant embedment under depletion, proppant crushing, damage as a result of fracturing fluid, fines migration and proppant-pack permeability-damage are some of the factors that contribute to production decline after hydraulic fracturing in shale reservoirs. The Caney Shale is a calcareous organic-rich mudrock. Various studies have investigated the effect that clay on shale well productivity, however, there is currently no literature on the Caney shale in relation to horizontal wells; all available literature exists in vertical wells as well as on formations of the Caney that are shallow in comparison to an emerging play which is twice the depth. In this paper we investigate stress-dependent fracture conductivity of proppant-filled fractures and proppant embedment in Caney shale through laboratory and modeling studies. API fracture conductivity tests were conducted using 2% KCl on five locations within the Caney shale that consisted of selecting three brittle(reservoir) zones and two ductile zones. Confining pressures range from 1,000 psi to 12,000 psi at 210°F. Conductivity, permeability as well as embedment were measured during the test. Our experimental results have confirmed that improved fracture conductivity is attributed to; proppant size, the increase in porosity of the proppant pack, closure pressure changes and the reduction in fracture conductivity are a function of many factors such as fracture closure stress. The findings from this study could help the stimulation design by providing new insights into the critical factors that are to be determined to facilitate the choice of proppants as well as fracturing fluids for long term production and recovery from shale reservoirs. 1 INTRODUCTION The development of low permeability formations, like shales, has been aided by hydraulic fracturing of horizontal wells (Radonjic et al., 2020). Hydraulic fracturing fluid is injected at a high pressure to induce tensile fractures that can link to and stimulate natural fractures (Katende et al., 2021a,b). Preserving adequate conductivity in hydraulic fractures over the life of the wells is required for economic production; nevertheless, conserving such conductivity can be difficult in some circumstances, particularly in soft, clay-rich formations (Wang et al., 2021). Proppant particles help to keep the fractures open when the pumping stops and the fracturing fluid returns to the wellbore, producing one or more propped hydraulic fractures of varying length, breadth, and height (Katende et al., 2021a). The proppant pack within the hydraulic fracture boosts well output by providing a greater permeability flowpath for hydrocarbons (Duenckel et al., 2016). Proppant in the fracture is under complicated stress conditions, and the interplay between the rock formation and the proppant pack has a significant impact on proppant-pack permeability (Karazincir et al., 2019). Proppant may be embedded (Katende et al., 2021a) in the rock or crushed into small pieces if the proppant size and strength characteristics are not specified appropriately, resulting in a loss in proppant-pack permeability and fracture aperture, and consequently a fall in well output.

Katende, A.↗

Validation of single-fluid and two-fluid magnetohydrodynamic models of the helicity injected torus spheromak experiment with the NIMROD code

We present a comparison study of 3-D pressureless resistive MHD (rMHD) and 3-D presureless two-fluid MHD models of the Helicity Injected Torus with Steady Inductive helicity injection (HIT-SI). HIT-SI is a current drive experiment that uses two geometrically asymmetric helicity injectors to generate and sustain toroidal plasmas. The comparable size of the collisionless ion skin depth d{sub i} to the resistive skin depth predicates the importance of the Hall term for HIT-SI. The simulations are run with NIMROD, an initial-value, 3-D extended MHD code. The modeled plasma density and temperature are assumed uniform and constant. The helicity injectors are modeled as oscillating normal magnetic and parallel electric field boundary conditions. The simulations use parameters that closely match those of the experiment. The simulation output is compared to the formation time, plasma current, and internal and surface magnetic fields. Results of the study indicate 2fl-MHD shows quantitative agreement with the experiment while rMHD only captures the qualitative features. The validity of each model is assessed based on how accurately it reproduces the global quantities as well as the temporal and spatial dependence of the measured magnetic fields. 2fl-MHD produces the current amplification (I{sub tor}/I{sub inj}) and formation time τ{sub f} demonstrated by HIT-SI with similar internal magnetic fields. rMHD underestimates (I{sub tor}/I{sub inj}) and exhibits much a longer τ{sub f}. Biorthogonal decomposition (BD), a powerful mathematical tool for reducing large data sets, is employed to quantify how well the simulations reproduce the measured surface magnetic fields without resorting to a probe-by-probe comparison. BD shows that 2fl-MHD captures the dominant surface magnetic structures and the temporal behavior of these features better than rMHD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Intraosseous Venography with Carbon Dioxide in Percutaneous Vertebroplasty: Carbon Dioxide Retention in Renal Veins

The objective of the present study was to determine the frequency of gas retention in the renal vein following carbon dioxide intraosseous venography in the prone position and, while citing references, to examine its onset mechanisms. All percutaneous vertebroplasties performed at our hospital from January to December 2005 were registered and retrospectively analyzed. Of 43 registered procedures treating 79 vertebrae, 28 procedures treating 54 vertebrae were analyzed. Vertebral intraosseous venography was performed using carbon dioxide as a contrast agent in all percutaneous vertebroplasty procedures. In preoperative and postoperative vertebral CT, gas retention in the renal vein and other areas was assessed. Preoperative CT did not show gas retention (0/28 procedures; 0%). Postoperative CT confirmed gas retention in the renal vein in 10 of the 28 procedures (35.7%). Gas retention was seen in the right renal vein in 8 procedures (28.6%), in the left renal vein in 5 procedures (17.9%), in the left and right renal veins in 3 procedures (10.7%), in vertebrae in 22 procedures (78.6%), in the soft tissue around vertebrae in 14 procedures (50.0%), in the spinal canal in 12 procedures (42.9%), and in the subcutaneous tissue in 5 procedures (17.9%). In conclusion, in our study, carbon dioxide gas injected into the vertebra frequently reached and remained in the renal vein.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Northwest Geysers EGS Demonstration Project, California. Pre-stimulation Modeling and Interpretation of the Stimulation

The Northwest Geysers Enhanced Geothermal System (EGS) demonstration project aims to create an EGS by directly and systematically injecting cool water at relatively low pressure into a known High Temperature (280–400 °C) Zone (HTZ) located under the conventional (240 °C) geothermal steam reservoir at The Geysers geothermal field in California. Here we report that , the results of coupled thermal, hydraulic, and mechanical (THM) analyses made using a model developed as part of the pre-stimulation phase of the EGS demonstration project is presented. The model simulations were conducted in order to investigate injection strategies and the resulting effects of cold-water injection upon the EGS system; in particular to predict the extent of the stimulation zone for a given injection schedule. The actual injection began on October 6, 2011, and in this paper a comparison of pre-stimulation model predictions with micro-earthquake (MEQ) monitoring data over the first few months of a one-year injection program is presented. The results show that, by using a calibrated THM model based on historic injection and MEQ data at a nearby well, the predicted extent of the stimulation zone (defined as a zone of high MEQ density around the injection well) compares well with observed seismicity. The modeling indicates that the MEQ events are related to shear reactivation of preexisting fractures, which is triggered by the combined effects of injection-induced cooling around the injection well and small changes in steam pressure as far as half a kilometer away from the injection well. Pressure-monitoring data at adjacent wells and satellite-based ground-surface deformation data were also used to validate and further calibrate reservoir-scale hydraulic and mechanical model properties. The pressure signature monitored from the start of the injection was particularly useful for a precise back-calculation of reservoir porosity. Ultimately, the first few months of reservoir pressure and surface deformation data were useful for estimating the reservoir-rock permeability and elastic modulus. Finally, although the extent of the calculated stimulation zone matches the field observations over the first few months of injection, the observed surface deformations and MEQ evolution showed more heterogeneous behavior as a result of more complex geology, including minor faults and fracture zones that are important for consideration in the analysis of energy production and the long-term evolution of the EGS system.

58 GEOSCIENCES↗