Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Environmental Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

A Spreadsheet Simulation Tool for Terrestrial and Planetary Balloon Design

During the early stages of new balloon design and development, it is necessary to conduct many trade studies. These trade studies are required to determine the design space, and aid significantly in determining overall feasibility. Numerous point designs then need to be generated as details of payloads, materials, mission, and manufacturing are determined. To accomplish these numerous designs, transient models are both unnecessary and time intensive. A steady state model that uses appropriate design inputs to generate system-level descriptive parameters can be very flexible and fast. Just such a steady state model has been developed and has been used during both the MABS 2001 Mars balloon study and the Ultra Long Duration Balloon Project. Using Microsoft Excel's built-in iteration routine, a model was built. Separate sheets were used for performance, structural design, materials, and thermal analysis as well as input and output sheets. As can be seen from figure 1, the model takes basic performance requirements, weight estimates, design parameters, and environmental conditions and generates a system level balloon design. Figure 2 shows a sample output of the model. By changing the inputs and a few of the equations in the model, balloons on earth or other planets can be modeled. There are currently several variations of the model for terrestrial and Mars balloons, as well there are versions of the model that perform crude material design based on strength and weight requirements. To perform trade studies, the Visual Basic language built into Excel was used to create an automated matrix of designs. This trade study module allows a three dimensional trade surface to be generated by using a series of values for any two design variables. Once the fixed and variable inputs are defined, the model automatically steps through the input matrix and fills a spreadsheet with the resulting point designs. The proposed paper will describe the model in detail, including current variations. The assumptions, governing equations, and capabilities will be addressed. Detailed examples of the model in practice will also be used.

Raquea, Steven M.↗

Hot Hydrogen Testing of Tungsten-Uranium Dioxide (W-UO2) CERMET Fuel Materials for Nuclear Thermal Propulsion

CERMET fuel materials are being developed at the NASA Marshall Space Flight Center for a Nuclear Cryogenic Propulsion Stage. Recent work has resulted in the development and demonstration of a Compact Fuel Element Environmental Test (CFEET) System that is capable of subjecting depleted uranium fuel material samples to hot hydrogen. A critical obstacle to the development of an NCPS engine is the high-cost and safety concerns associated with developmental testing in nuclear environments. The purpose of this testing capability is to enable low-cost screening of candidate materials, fabrication processes, and further validation of concepts. The CERMET samples consist of depleted uranium dioxide (UO2) fuel particles in a tungsten metal matrix, which has been demonstrated on previous programs to provide improved performance and retention of fission products1. Numerous past programs have utilized hot hydrogen furnace testing to develop and evaluate fuel materials. The testing provides a reasonable simulation of temperature and thermal stress effects in a flowing hydrogen environment. Though no information is gained about radiation damage, the furnace testing is extremely valuable for development and verification of fuel element materials and processes. The current work includes testing of subscale W-UO2 slugs to evaluate fuel loss and stability. The materials are then fabricated into samples with seven cooling channels to test a more representative section of a fuel element. Several iterations of testing are being performed to evaluate fuel mass loss impacts from density, microstructure, fuel particle size and shape, chemistry, claddings, particle coatings, and stabilizers. The fuel materials and forms being evaluated on this effort have all been demonstrated to control fuel migration and loss. The objective is to verify performance improvements of the various materials and process options prior to expensive full scale fabrication and testing. Post test analysis will include weight percent fuel loss, microscopy, dimensional tolerance, and fuel stability.

Hickman, Robert↗

Western Montana Ecological Forecasting II: Enhancing Habitat Suitability Modeling of Mustelid Species and Contaminant Monitoring in Northern Montana Using NASA Earth Observations

Environmental contaminants in aquatic ecosystems threaten both human and ecosystem health. Western Montana’s rivers possess great economic and ecological value, yet the status of contaminants in these systems can be unclear. Contaminants such as brominated flame-retardants, heavy metals, and pharmaceuticals negatively affect ecosystem health by traveling through the food chain and bioaccumulating in apex predators. Exposure to these contaminants can result in neurological, endocrine, and reproductive impairments in wildlife and humans. American mink (Neovison vison) and North American river otter (Lontra canadensis) have a predominantly aquatic diet and serve as reliable indicator species of environmental health. Working Dogs for Conservation (WD4C) uses detection dogs to locate scat samples of these species which are assessed for contaminants by the Virginia Institute of Marine Science (VIMS). With Software for Assisted Habitat Modeling (SAHM), the team generated current (2013-2020) and projected (2021-2040) habitat suitability models for mink and otter utilizing NASA Earth observations from Terra Moderate Resolution Imaging Spectroradiometer (MODIS), Global Precipitation Measurement Integrated Multi-Satellite Retrievals for GPM (GPM IMERG), Shuttle Radar Topography Mission (SRTM), and Soil Moisture Active Passive (SMAP). The habitat suitability maps’ study region encompassed Flathead National Forest and Blackfeet Indian Reservation. Additionally, the team created site accessibility and precipitation anomaly maps that display the viability of survey locations. The current habitat suitability models performed well (AUC-PR=0.88). The most important predictor variables for suitable habitat were distance to rivers, elevation, and land cover. These end products will further inform WD4C survey site selection and contaminant monitoring.

Chelsea Morton↗

Testing and validation of the microbial environment of the NASA rodent spaceflight habitat water delivery system.

Sterilized, deionized water within a closed, self-sufficient system has been used in NASA spaceflight rodent studies for several decades. Within the specialized spaceflight rodent habitat, water is delivered through a compression spring-loaded bag system to maintain positive pressure. Refill of the drinking water occurs every 30 days by direct transfer of potable water from aboard the International Space Station (ISS). This enables long term use without a weekly water change out, which meets spaceflight requirements, but contrasts with the general guidelines for the sanitation of water delivery systems. Even though the water is iodinated to minimize microbial growth, rodents are fed a special diet of high moisture nutrient-rich food bars based on the AIN-93 diet that may contribute to microbial growth in this water system. We designed a ground study to assess the quality of drinking water that is given to rodents throughout a mission. We conducted the ground test using 20 female C57BL/6J mice housed in this specialized habitat to mimic the timeline of a 90-day mission as well as the environmental conditions (temperature, humidity, and pCO2) within the ISS. We used a novel sampling method to test water at 2-week intervals for the 90-days, and also after each 30-day refill of the water delivery system. Mice in standard vivarium cages with water bottles were also included for comparison to the habitat. The results showed that overall microbial load remained close to zero for the duration, while total organic compound concentrations increased from 1370g/L to 10650g/L over the course of 90 days but remained below the level of concern. Inorganic ions and pH were also found to be at acceptable levels. Overall, we conclude that this system is effective in delivering clean, potable water to rodents for the 90-day duration of current missions to the ISS.

water↗

Investigating the Applications of In-Situ Resource Utilization for Future Crewed Mars Missions

There are significant gaps in knowledge regarding the water ice on Mars and future preparation for human missions. So far, six rovers have traversed Mars’ rocky surface, aiming to understand the planet’s composition and search for signs of life. A rover mission set to explore the high northern latitudes of Mars with the goal of analyzing ice cores could greatly advance scientific knowledge to better understand Mars’s ancient climate and geochemistry. As of now, little has been accomplished in the exploration of colder regions and the extraction of water ice apart from the Phoenix lander and the Viking 2 mission; however, the science potential of the Phoenix and Viking landers was limited due to their inability to explore terrain like rovers. The exploration of the near-polar region Arcadia Planitia and its water ice deposits could reveal signs of past microbial life through preserved biosignatures. Additionally, to prepare for permanent human habitation on Mars, this proposed rover could continue the characterization of Mars’s current land and mineral composition, and search for materials that future humans may need on Mars (such as water for habitation, basalt for construction, and olivine for manufacturing purposes). This would increase understanding of the potential for in-situ resource utilization (ISRU) on Mars. The use of ISRU will reduce the amount of material needed on the initial flight, and similarly will reduce fuel costs. The mission to Arcadia Planitia incorporates the use of various mineral-extracting and imaging instruments (Martian Ice Core Analyzer, ground-penetrating radar, NavCam, Mars Environmental Dynamics Analyzer, SuperCam, etc.) to collect data from water ice and geologic samples. A near-polar rover mission to Mars would illuminate Mars’ past and present, while learning more about martian resources to benefit human explorers in the future.

Annika Sachdeva↗

Visible and Near-IR Reflectance Spectra for Smectite, Sulfate And Perchlorate under Dry Conditions for Interpretation of Martian Surface Mineralogy

Visible and near-IR (VNIR) spectral data for the martian surface obtained from orbit by the MRO-CRISM and OMEGA instruments are interpreted as having spectral signatures of H2O/OH-bearing phases, including smectites and other phyllosilicates, sulfates, and high-SiO2 phases [e.g., 1-4]. Interpretations of martian spectral signatures are based on and constrained by spectra that are obtained in the laboratory on samples with known mineralogical compositions and other physicochemical characteristics under, as appropriate, Mars-like environmental conditions (e.g., temperature, pressure, and humidity). With respect to environmental conditions, differences in the absolute concentration of atmospheric H2O can effect the hydration state and therefore the spectra signatures of smectite phyllosilicates (solvation H2O) and certain sulfates (hydration H2O) [e.g., 5-7]. We report VNIR spectral data acquired under humid (laboratory air) and dry (dry N2 gas) environments for two natural smectites (nontronite API-33A and saponite SapCa-1) to characterize the effect of solvation H2O on spectral properties. We also report spectral data for the thermal dehydration products of (1) melanterite (FeSO4.7H2O) in both air and dry N2 gas and (2) Mg-perchlorate (Mg(ClO4)2.6H2O) in dry N2 environments. Spectral measurements for samples dehydrated in dry N2 were made without exposing them to humid laboratory air.

Morris, R.V.↗

Alterations in renal stone risk factors after space flight

Exposure to the microgravity environment of space produces a number of physiological changes of metabolic and environmental origin that could increase the potential for renal stone formation. Metabolic, environmental and physicochemical factors that influence renal stone risk potential were examined in 24-hour urine samples from astronauts 10 days before launch and on landing day to provide an immediate postflight assessment of these factors. In addition, comparisons were made between male and female crewmembers, and between crewmembers on missions of less than 6 days and those on 6 to 10-day missions. Results suggest that immediately after space flight the risk of calcium oxalate and uric acid stone formation is increased as a result of metabolic (hypercalciuria, hypocitraturia, pH) and environmental (lower urine volume) derangements, some of which could reflect residual effects of having been exposed to microgravity.

NASA Center JSC↗

Former SLF Fire and Rescue Building SWMU #120 Per- and Polyfluoroalkyl Substances (PFAS) Site Assessment Work Plan

This Work Plan documents the proposed field sampling activities for a per- and polyfluoroalkyl substances (PFAS) Site Assessment at the Former Space Shuttle Landing Facility (SLF) Fire and Rescue Building (FRB) at Kennedy Space Center (KSC). The Work Plan provides a background of the historical activities that occurred at the SLF FRB, and the limited environmental investigations performed at the SLF FRB. The proposed Site Assessment activities at SLF FRB includes the collection of soil samples from eight locations, the advancement of a soil lithologic boring to 60 feet below ground surface, the installation of a staff gauge in site surface water, the installation of four monitoring wells, perform direct push groundwater sampling at seven locations, and collect one surface water sample. Sampling details, depths, and locations are presented in the Work Plan. The Work Plan was presented to the KSC Remediation Team in the form of an Advance Data Package in February 2023. Following STRIVES approval, the SLF FRB PFAS Site Assessment Work Plan will be formally submitted to the Florida Department of Environmental Protection.

Howard Franklin Fowler↗

Portable 4.6 Micrometers Laser Absorption Spectrometer for Carbon Monoxide Monitoring and Fire Detection

The air quality aboard manned spacecraft must be continuously monitored to ensure crew safety and identify equipment malfunctions. In particular, accurate real-time monitoring of carbon monoxide (CO) levels helps to prevent chronic exposure and can also provide early detection of combustion-related hazards. For long-duration missions, environmental monitoring grows in importance, but the mass and volume of monitoring instruments must be minimized. Furthermore, environmental analysis beyond low-Earth orbit must be performed in-situ, as sample return becomes impractical. Due to their small size, low power draw, and performance reliability, semiconductor-laser-based absorption spectrometers are viable candidates for this purpose. To reduce instrument form factor and complexity, the emission wavelength of the laser source should coincide with strong fundamental absorption lines of the target gases, which occur in the 3 to 5 micrometers wavelength range for most combustion products of interest, thereby reducing the absorption path length required for low-level concentration measurements. To address the needs of current and future NASA missions, we have developed a prototype absorption spectrometer using a semiconductor quantum cascade laser source operating near 4.6 micrometers that can be used to detect low concentrations of CO with a compact single-pass absorption cell. In this study, we present the design of the prototype instrument and report on measurements of CO emissions from the combustion of a variety of aerospace plastics.

Tunable Environmental Laser Spectrometer (TELS)↗

Analysis of CDC Bioreactor Internal Thermal Measurements and Sample Coupon Temperatures

The Center for Disease Control and Prevention (CDC) bioreactor is an integral laboratory tool for the Environmental Control and Life Support Systems (ECLSS) biofilm formation and growth research program. Critical to this research is the need to adjust and maintain various surface temperatures of the coupons housed within the CDC Bioreactor. The purpose of this study was to provide quantitative temperature gradient information when the CDC Bioreactor was operating according to several process scenarios. Two primary process parameters were evaluated. For the first set of test parameters, the liquid level was maintained at 350 mL, with an inlet flowrate of 0.1 mL/min, 1 mL/min, 10 mL/min. The liquid was allowed to gravity drain out of the outlet spout. For the second set of test parameters, the liquid level within the reactor was maintained at 550 mL, with an inlet flow of 0.1 mL/min, 1 mL/min, 10 mL/min and draining intermittently controlled to 0.8 mL/min to maintain the 550 mL level. Due to the placement of the thermocouple in the reactor, a difference in temperature occurred between the coupon surfaces and target Bioreactor temperature when operated according to the first set of test parameters. When the reactor was operated according to the second set of parameters, which resulted in the thermocouple being submerged, the temperature gradient was eliminated. The results demonstrated minimal temperature gradient between the top and bottom coupon surfaces for coupons placed in a single rod within the CDC Bioreactor for both sets of test parameters evaluated. The collection of this information helped to explain previous ECLSS biofilm formation test runs, along with providing guidance on best operating practices for future ECLSS experiments. The placement of the thermocouple also helps to explain the challenge of achieving and maintaining bulk liquid temperatures when biofilm is grown according to the standardized test methods.

CDC Bioreactor↗

Characterization of Evidence for Human System Risk Assessment

Understanding the kinds of evidence available and using the best evidence to answer a question is critical to evidenced-based decision-making, and it requires synthesis of evidence from a variety of sources. Categorization of human system risks in spaceflight, in particular, focuses on how well the integration and interpretation of all available evidence informs the risk statement that describes the relationship between spaceflight hazards and an outcome of interest. A mature understanding and categorization of these risks requires: 1) sufficient characterization of risk, 2) sufficient knowledge to determine an acceptable level of risk (i.e., a standard), 3) development of mitigations to meet the acceptable level of risk, and 4) identification of factors affecting generalizability of the evidence to different design reference missions. In the medical research community, evidence is often ranked by increasing confidence in findings gleaned from observational and experimental research (e.g., "levels of evidence"). However, an approach based solely on aspects of experimental design is problematic in assessing human system risks for spaceflight. For spaceflight, the unique challenges and opportunities include: (1) The independent variables in most evidence are the hazards of spaceflight, such as space radiation or low gravity, which cannot be entirely duplicated in terrestrial (Earth-based) analogs, (2) Evidence is drawn from multiple sources including medical and mission operations, Lifetime Surveillance of Astronaut Health (LSAH), spaceflight research (LSDA), and relevant environmental & terrestrial databases, (3) Risk metrics based primarily on LSAH data are typically derived from available prevalence or incidence data, which may limit rigorous interpretation, (4) The timeframe for obtaining adequate spaceflight sample size (n) is very long, given the small population, (5) Randomized controlled trials are unattainable in spaceflight, (6) Collection of personal and environmental data on the astronaut population may create opportunities for advanced analytics and human-environment modeling that goes beyond that achieved in isolated experimental designs; and (7) Translation of relevant research to operations is a complex, transdisciplinary enterprise in which the approach must apply across the physical, biological, behavioral, and social sciences. The approach to synthesizing evidence must address both source and fidelity of data, and reflect the most general attributes of quality of evidence in science and engineering: reliability and validity. The authors are developing a two-factor approach which includes the various kinds of evidence required to understand risks and for the integrated interpretation of all evidence that is essential to develop standards and countermeasures. A unified framework for aggregating and assessing different kinds of evidence provides a consistent, traceable, evidence-based decision-making process to translate research to operations in an environment where engineers, scientists, physicians, and managers all engage in analyzing the trade space of vehicle design, standards, requirements and solutions for spaceflight.

Steinberg, S. L.↗

Components Refurbishment and Chemical Analysis Facility, SWMU #041 - Per- and Polyfluoroalkyl Substances Site Assessment Report Kennedy Space Center, Florida

This PFAS Site Assessment (SA) Report presents the activities and results associated with PFAS investigations at the Components Refurbishment and Chemical Analysis (CRCA) facility located at Kennedy Space Center (KSC), Florida. In 2022, CRCA was identified as an Area of Potential Concern because the facility stores several potential PFAS-containing chemicals. A groundwater sample collected from an onsite monitoring well detected PFOA and PFOS at concentrations greater than State of Florida provisional Groundwater Cleanup Target Levels (pGCTLs). PFAS SA activities were conducted between March 2022 and February 2024. During this timeframe, a total of 16 direct-push technology (DPT) locations and 82 discrete samples were collected from these locations, along with 90 monitoring well samples. The analytical data screening process focused on State of Florida pGCTLs and United States Environmental Protection Agency (USEPA) Regional Screening Level (RSLs) from November 2023 to evaluate the data. Analytical results identified PFOS, PFOA, and PFBA at concentrations exceeding their respective RSLs at each depth interval (shallow, intermediate, and deep). PFOS and PFOA had the largest footprint of RSL exceedances in each depth interval, but pGCTL exceedances were only observed at limited locations in the shallow and intermediate intervals. PFBA had the highest detections of any PFAS compound, with concentrations exceeding 180,000 nanograms per liter (ng/L), which is 100-times the RSL of 1,800 ng/L in the shallow and intermediate intervals and 10-times the RSL in the deep interval. The maximum PFBA detection was 841,000 ng/L at shallow monitoring well, MW0006. The PFAS SA also included samples collected from the onsite hydraulic containment system (HCS) which was installed to control and treat the onsite chlorinated volatile organic compound (CVOC) plume. Influent and effluent aqueous samples were collected monthly from the system. PFAS concentrations were relatively the same for both influent and effluent samples, indicating that while the HCS has been effective for CVOC treatment, it does not provide any additional treatment for PFAS compounds. Since the HCS has achieved its objectives, the system was shut down in December 2024. PFAS data gaps still exist, to include surface water and soil, which were not sampled during this SA. Soil sampling near the Chemical Process Area is recommended. Surface water and soil sampling at select stormwater outfalls is also recommended. Additionally, further groundwater sampling is recommended (DPT and monitoring well) in all depth intervals to delineate the extent of PFAS impacts at CRCA.

K Alex Murphy↗

Cytometer on a chip

An assay technique for label-free, highly parallel, qualitative and quantitative detection of specific cell populations in a sample and for assessing cell functional status, cell-cell interactions and cellular responses to drugs, environmental toxins, bacteria, viruses and other factors that may affect cell function. The technique includes a) creating a first array of binding regions in a predetermined spatial pattern on a sensor surface capable of specifically binding the cells to be assayed; b) creating a second set of binding regions in specific spatial patterns relative to the first set designed to efficiently capture potential secreted or released products from cells captured on the first set of binding regions; c) contacting the sensor surface with the sample, and d) simultaneously monitoring the optical properties of all the binding regions of the sensor surface to determine the presence and concentration of specific cell populations in the sample and their functional status by detecting released or secreted bioproducts.

Lynes, Michael A.↗

The NASA Ames Closed Environmental Research Chamber: Present Status

The Closed Environmental Research Chamber (CERC) at the NASA Ames Research Center was created to investigate both components and complete systems for life support of advanced space exploration missions. This facility includes a Main Chamber, an Airlock, a Sample Transfer Lock, a Vacuum System, an Air Recompression System, a dedicated control room and a pit area for housing supporting and environmental control systems. The Main Chamber provides 310 sq ft of internal working/living space on two levels. It is planned that the CERC will be a human-rated facility for habitation simulation under mass balance closure conditions. The internal pressure will be variable over the range of 14.7 psia to 5 psia with accompanying capability for variation in atmosphere composition to maintain the oxygen partial pressure at 160 mm Hg. The CERC will be provided with a core set of primary life support subsystems for temperature and humidity control, C02 removal and trace contaminant control. Interfacing with external life support technology test b~ds with be provided, along with connection to centralized, microprocessor-based data acquisition and control systems. This paper will discuss the current status of the CERC facility and show how it is being used to address the advanced technology requirements necessary to implement an integrated working and living environment for a planetary habitat. In particular, it will be shown how the CERC, along with a human-powered centrifuge, a planetary terrain simulator and advanced displays and a virtual reality capability will work together to develop and demonstration applicable technologies for future planetary habitats. Artificial intelligence and expert system programming techniques will be used extensively to provide an automated environment for a 4-person crew. There will be several robotic mechanisms performing exploration tasks external to the habitat that will be controlled through the virtual environment to provide representative workloads for the crew. Finally, there will be a discussion of how effective are innovative new multidisciplinary test facilities to the investigation of the wide range of human and machine problems inherent in exploration missions.

Gross, Anthony R.↗

Launch Complex 39B, SWMU 009, 2023 Performance Monitoring and Air Sparge Expansion Construction Completion Report, Kennedy Space Center, Florida

The 2023 Performance Monitoring and Construction Completion Report (PM-CCR) presents the findings, observations, and results for Air Sparging (AS) operations and expansion activities, as well as sitewide groundwater monitoring for Launch Complex 39B (LC39B), Solid Waste Management Unit (SWMU) 009, at Kennedy Space Center (KSC), Florida. The reporting period for activities covered under this PM-CCR is from January 1, 2023, to December 31, 2023. At LC39B, AS operations began in 2017 in the area west of the launch pad, in the liquid oxygen (LOX) tank area located northwest of the launch pad, and in an area outside of the perimeter fence to protect nearby Outstanding Florida Waters (OFW). The LC39B AS system was installed with 279 AS wells to depths ranging from 23 to 60 feet below land surface (bls), including the sump, correlating to top of screen depths ranging from 20 to 57 feet bls. In December 2022, a total of 22 AS wells were abandoned to support launch pad crane operations, and in November 2023, the system was expanded with five additional AS wells installed to 13 or 17 feet bls near the LOX tank. The remedial objective of the LC39B AS Interim Measure (IM) is to actively decrease concentrations of contaminants of concern (COCs) in groundwater, specifically trichloroethene (TCE), cis-1,2-Dichloroethene (cDCE), and vinyl chloride (VC), to less than their respective Natural Attenuation Default Concentrations (NADCs), so LC39B can transition into a Long-Term Monitoring (LTM) program. This PM-CCR presents the following information for LC39B: • AS system operations and maintenance (O&M) (Year 7 of operation) from January 2023 to December 2023, to include AS trailer relocation in March 2023 and subsequent replacement and re-start in June 2023. • Construction completion details for AS system expansion, which included installation of five new AS wells and one new monitoring well in November 2023. As part of expansion activities, soil samples were also collected for petroleum analysis; no exceedances were identified, and no further investigation for petroleum is warranted. • Performance monitoring results for groundwater sampling events conducted in May/June 2023 (30 wells) and November 2023 (31 wells) in the AS IM area and in the Low Concentration Plume (LCP) areas located north and east of the launch pad for volatile organic compound (VOC) analysis. • Sampling results for one monitoring well, LOX-IW0012S, which is sampled for aluminum on an annual basis (May/June 2023). This well was resampled in November 2023 for both total and dissolved aluminum. Due to a communication error with the laboratory, the May/June 2023 sample was analyzed for total aluminum only. • Groundwater sampling results for per- and polyfluoroalkyl substances (PFAS) collected from seven monitoring wells during the May/June 2023 event to further investigate the Former Sewage Treatment Plant #6 and Percolation Pond area, west of the launch pad. O&M and performance monitoring results show that the AS system at LC39B is operating as designed and meeting performance criteria. Overall runtime was 45 percent (%) during the reporting period (January to December), but the operational runtime was 78% during the timeframe when the system could run (June to December). The most significant downtime contributor was post-launch crane operations following the Artemis launch on November 16, 2022, which lasted until June 2023. During that timeframe, the AS trailer at LC39B was relocated to another KSC remediation site (Wilson Corners) and was subsequently replaced with the AS trailer from the Paint & Oil Locker (POL) remediation site at KSC to resume AS system operations. Performance monitoring results in the AS IM and LCP areas continue to show reduction in COC concentrations over time when compared to baseline levels. In 2023, only one monitoring well (MW0048) detected a COC exceeding its NADC (VC at 740 micrograms per liter [µg/L]), which marks the baseline result for this new well installed during system expansion. Across the rest of the site, VC concentrations have declined or remained stable during the 2023 sampling events. Excluding MW0048, the highest VC result in 2023 was during the May/June sampling event with a concentration of 63 µg/L at MW0032, which is located near MW0048 and the AS expansion area by the LOX tank. TCE was detected in select monitoring wells in the IM area in 2023, but only two locations exceeded the State of Florida Groundwater Cleanup Target Level (GCTL): MW0032 (21 µg/L in May/June 2023 and 9.1 µg/L in November 2023) and MW0036 (5.0 µg/L in November 2023). MW0036 is also located near the LOX tank, on the north side, where the AS system is still operational (Zone Z4). cDCE and trans-1,2-dichloroethene concentrations were less than laboratory method detection limits or their respective GCTLs in all wells sampled in 2023. Near the OFW located northwest of the launch complex, all COC concentrations were less than laboratory method detection limits from monitoring wells (MW0039, MW0040, and LOXTA0002S) sampled in 2023. Aluminum results from LOX-IW0012S, which has been sampled routinely since 2006, detected a total aluminum concentration of 3,900 µg/L during the May/June 2023 sampling event. Results from the November 2023 event detected 5,700 µg/L for total aluminum and 5,500 µg/L for dissolved aluminum. These concentrations slightly decreased from the previous year but remain relatively consistent with historical detections. Aluminum will continue to be sampled on an annual basis at this well as results still exceed the GCTL of 200 µg/L and the Upper Limit of the KSC Background Concentration of 280 µg/L. PFAS results detected nine different PFAS compounds (out of 32 analyzed) from seven wells sampled. Two PFAS compounds, perfluorooctanesulfonic acid (PFOS) and perfluorooctanoic acid (PFOA), currently have FDEP Provisional GCTLs of 70 nanograms per liter (ng/L). All seven samples collected resulted in concentrations less than the FDEP Provisional GCTLs for both PFAS compounds; no exceedances were observed. PFOS and PFOA also have assigned United States Environmental Protection Agency (USEPA) Maximum Contaminant Levels (MCLs) of 4 nanograms per liter (ng/L). None of the PFOS results exceeded the USEPA MCLs. PFOA was detected in two samples above the USEPA MCL at concentrations of 5.8 ng/L (ECS-IW0009I) and 5.5 ng/L (ECS-IW0009S). Three other PFAS compounds, perfluorohexanesulfonic acid (PFHxS), perfluoro-n-nonanoic acid (PFNA), and hexafluoropropylene oxide dimer acid (GenX), currently have USEPA MCLs of 10 ng/L. PFHxS, PFNA, and GenX were not detected at concentrations greater than their respective USEPA MCLs in any of the seven wells. PFAS compounds without FDEP Provisional GCTLs or USEPA MCLs were screened against USEPA RSLs. No other detections exceeded their respective USEPA RSLs. Additional PFAS sampling will be conducted as part of a future PFAS Site Assessment. Based on O&M activities and performance monitoring, the following is recommended for LC39B: • Continue with Year 8 AS system operation within Zone Z4, which includes the AS expansion area. Zone Z3, which has been off since 2018, should remain off as no rebound has been observed. Zones Z1 and Z2, which were turned off at the end of 2022, will remain shut down as monitoring well results have consistently been below GCTLs or have low-level detections with stable or decreasing trends (Meeting Minute 2402-M10, Decision 2402-D30). • Continue with performance monitoring in 2024 with the same monitoring well network as 2023, except with the addition of MW0048 in both semi-annual events. Baseline concentrations for this well were collected during the November 2023 performance monitoring event. Semi-annual sampling should be planned for the May 2024 and November 2024 timeframes (Meeting Minute 2402-M10, Decision 2402-D31). • Continue sampling monitoring well, LOX-IW0012S, for aluminum (total and dissolved) on an annual basis in May 2024. It is also recommended to re-develop this well prior to the next sampling event (Meeting Minute 2402-M10, Decision 2402-D32). The above recommendations for LC39B were presented at the February 2024 KSCRT Meeting, with Team consensus reached on the path forward. The contents of this PM-CCR were also presented at this meeting.

Deborah M Wilson↗

Integrated Design Results for the MSR DAC-0.0 Mars Ascent Vehicle

The NASA Mars Sample Return (MSR) Campaign endeavors to return Martian regolith, rock, and atmospheric samples to Earth for scientific study. One of many significant challenges to overcome in the return of thesesamples lies in transporting them from the Martian surface to space. In order to surmount this challenge, the Campaign has conceptualized the need for a Mars Ascent Vehicle (MAV) to perform this function and deliver Martian samples to orbit. There, the samples will be ejected and captured by a separate spacecraft for return to Earth. Many concepts for a MAV have existed in the past, but it has not been until now that an integrated, detailed design solution has been developed and analyzed. Preliminary assessments of the initial architecture examined multiple methods of propulsion. The team ultimately determined that a Two Stage to Orbit (TSTO) solid propulsion vehicle would provide the most effective performance and be the most technologically ready to support this mission. Following the decision to adopt a TSTO solid propelled vehicle, the first official Design Analysis Cycle, DAC-0.0, was performed in Spring 2020 to formally advance the fidelity of the vehicle to a maturity level acceptable for NASA Key Decision Point A (KDP-A). This paper describes the resultant MAV design concept developed as part of the DAC-0.0 study by the NASA Marshall Space Flight Center (MSFC), in association with the NASA Jet Propulsion Laboratory (JPL). The TSTO vehicle features two solid rocket motors, one powering each stage. Their thrust vectors are controlled with Thrust Vector Control (TVC) systems consisting of independent electromechanical actuators acting on gimballed nozzles. The vehicle is designed to deliver up to 0.47kg of Martian samples to a Mars circular orbit of 343km at 27° inclination. Due to the unique environmental conditions that this vehicle is required to operate in, the subsystem design teams were compelled to develop creative and unorthodox designs to ensure a successful mission. The detailed design and analysis of these subsystems are discussed in this paper and include topics on the MAV Guidance, Navigation, and Control (GNC); structures and mechanisms; integrated vehicle thermal; avionics and flight software; a hydrazine-based Reaction Control System (RCS); aerosciences; and vehicle assembly, integration, and test (AI&T) considerations, among others. Following the conclusion of the MAV DAC-0.0, additional alternative architecture concepts were also studied to further reduce the mass of the overall system.

Mars↗

Planetary protection, legal ambiguity and the decision making process for Mars sample return

As scientists and mission planners develop planetary protection requirements for future Mars sample return missions, they must recognize the socio-political context in which decisions about the mission will be made and pay careful attention to public concerns about potential back contamination of Earth. To the extent that planetary protection questions are unresolved or unaddressed at the time of an actual mission, they offer convenient footholds for public challenges in both legal and decision making realms, over which NASA will have little direct control. In this paper, two particular non-scientific areas of special concern are discussed in detail: 1) legal issues and 2) the decision making process. Understanding these areas is critical for addressing legitimate public concerns as well as for fulfilling procedural requirements regardless whether sample return evokes public controversy. Legal issues with the potential to complicate future missions include: procedural review under National Environmental Policy Act (NEPA); uncertainty about institutional control and authority; conflicting regulations and overlapping jurisdictions; questions about international treaty obligations and large scale impacts; uncertanities about the nature of the organism; and constitutional and regulatory concerns about quarantine, public health and safety. In light of these important legal issues, it is critical that NASA consider the role and timing of public involvement in the decision making process as a way of anticipating problem areas and preparing for legitimate public questions and challenges to sample return missions.

NASA Discipline Number 59-10↗

Acquisition of background and technical information and class trip planning

Instructors who are very familiar with a study area, as well as those who are not, find the field trip information acquisition and planning process speeded and made more effective by organizing it in stages. The stage follow a deductive progression: from the associated context region, to the study area, to the specific sample window sites, and from generalized background information on the study region to specific technical data on the environmental and human use systems to be interpreted at each site. On the class trip and in the follow up laboratory, the learning/interpretive process are at first deductive in applying previously learned information and skills to analysis of the study site, then inductive in reading and interpreting the landscape, imagery, and maps of the site, correlating them with information of other samples sites and building valid generalizations about the larger study area, its context region, and other (similar and/or contrasting) regions.

Mackinnon, R. M.↗