Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ENERGY SIMULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

2011 EnergyValue Housing Award Report

The EnergyValue Housing Award (EVHA), an integral part of the U.S. Department of Energy’s Building America (BA) program, seeks to improve and expand the energy efficiency of residential construction nationwide by honoring builders and remodelers and awarding highly efficient homes. Receiving EVHA recognition helps builders and remodelers communicate the value of energy efficiency to prospective customers and distinguish their homes from those built by more traditional residential construction companies. It also provides opportunities for EVHA winning builders and remodelers to set an example for improving the quality and performance of homes throughout the country. Each year, the project scope of the EVHA includes the application and judging processes, developing the EVHA publication, updating the program and application for the next year, hosting the EVHA banquet, and outreach and technical support. Following the award banquet, the NAHB Research Center evaluates the energy performance of that year’s EVHA winning houses. This work is primarily comprised of estimating the energy savings of each home/ or housing unit over the BA Benchmark using energy simulation software and procedures developed by the BA program. The energy evaluations serve as a quantitative measure of the energy efficiency of the units which the judges decided merited an award. As part of this work, the NAHB Research Center Industry Partnership (NAHBRC-IP) for High Performing Homes strives to make new and existing homes more energy efficient, durable, and affordable through research and development as one of the U.S. Department of Energy’s BA teams. Each year, through the EVHA, builder and remodeler partners work with industry partners in a variety of climates endeavor to reach the energy efficiency targets of the BA program. (Department of Energy 2012) This report details the simulation tool(s) and energy modeling methodology followed in making the energy efficiency estimates and documents the estimated performance of the EVHA award winning houses in comparison with the BA Benchmark and the associated House Simulation Protocols (HSPs). A summary of each building and its features is included with a brief description of the project and the judges’ comments. The purpose of this report is to assess the energy performance of the 2011 EVHA winners and to align the EVHA program with the BA program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A coupled fluid-mechanical workflow to simulate the directed energy deposition additive manufacturing process

Simulation of additive manufacturing processes can provide essential insight into material behavior, residual stress, and ultimately, the performance of additively manufactured parts. In this work, we describe a new simulation based workflow utilizing both solid mechanics and fluid mechanics based formulations within the finite element software package SIERRA (Sierra Solid Mechanics Team in Sierra/Solid Mechanics 4.52 User’s Guide SAND2019-2715. Technical report, Sandia National Laboratories, 2011) to enable integrated simulations of directed energy deposition (DED) additive manufacturing processes. In this methodology, a high-fidelity fluid mechanics based model of additive manufacturing is employed as the first step in a simulation workflow. This fluid model uses a level set field to track the location of the boundary between the solid material and background gas and precisely predicts temperatures and material deposition shapes from additive manufacturing process parameters. Next, the resulting deposition shape and temperature field from the fluid model are then mapped into a solid mechanics formulation to provide a more accurate surface topology for radiation and convection boundary conditions and a prescribed temperature field. Solid mechanics simulations are then conducted to predict the evolution of material stresses and microstructure within a part. By combining thermal history and deposition shape from fluid mechanics with residual stress and material property evolutions from solid mechanics, additional fidelity and precision are incorporated into additive manufacturing process simulations providing new insight into complex DED builds.

36 MATERIALS SCIENCE↗

Stochastic scheduling for commercial building cooling systems: considering uncertainty in zone temperature prediction

Here, this paper presents the first attempt to address the uncertainty in zone temperature prediction with stochastic optimization. The uncertain zone temperature is a process uncertainty and has not been considered in the existing stochastic optimization for building control. To fill this gap, we proposed a novel formulation of stochastic optimization to handle process uncertainty in building control. Specifically, we first examined the accuracy of a typical linear model for predicting zone temperature. We then formulated the scheduling of the building cooling system as a stochastic optimization problem over a 24-hour look-ahead period to minimize the electricity cost of the studied building cooling system. After that, we applied the proposed stochastic load scheduling (SLS) to a direct expansion (DX) cooling system that serves a medium office building. Through simulation with a detailed building energy simulation software, EnergyPlus, we evaluated the operational cost and the thermal comfort compared with a deterministic load scheduling. The operation cost of scheduling was found to vary with the level of zone temperature prediction uncertainty. The proposed SLS can mitigate the impacts of uncertain zone temperature predictions on both operational cost and thermal comfort. The evaluation results indicate that the proposed SLS works better when the uncertainty level is more significant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A method to generate heating and cooling schedules based on data from connected thermostats

Internet-connected thermostats are a promising new source of temperature and operational data in homes because they record inside temperatures, setpoints, and HVAC runtimes every five minutes. Over 20 million Internet-connected thermostats have already been installed in American homes. Data from about 20,000 connected thermostats were collected and organized by climate zone, number of occupants, floor area, and day type. A method was developed to create up to 40 representative temperature schedules which, together, can more accurately capture the diversity of heating and cooling behaviors. These results are suitable for input into schedules for building energy simulation models. This information enables more realistic simulations of American heating and cooling behavior, leading to more accurate estimates of energy consumption and savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

This study was conducted by the Pacific Northwest National Laboratory (PNNL) in support of the stretch energy code development led by the New York State Energy Research and Development Authority (NYSERDA). In 2017 NYSERDA developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code (hereinafter referred to as “NYStretch-Energy”). NYStretch-Energy is intended as a model energy code for statewide voluntary adoption that anticipates other code advancements culminating in the goal of a statewide Net Zero Energy Code by 2028. Since then, NYSERDA continues to develop the NYStretch-Energy Code 2018 edition. To support the effort, PNNL conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code (2018) in New York. The focus of this project is the 20% improvement over existing commercial model energy codes. A key requirement of the proposed stretch code is that it be ‘adoptable’ as an energy code, meaning that it must align with current code scope and limitations, and primarily impact building components that are currently regulated by local building departments. It is largely limited to prescriptive measures, which are what most building departments and design projects are most familiar with. This report describes a set of energy-efficiency measures (EEMs) that demonstrate 20% energy savings over ANSI/ASHRAE/IES Standard 90.1-2013 (ASHRAE 2013) across a broad range of commercial building types and all three climate zones in New York. In collaboration with New Building Institute, the EEMs were developed from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the on-going code development process. PNNL analyzed these measures using whole building energy models for selected prototype commercial buildings and multifamily buildings representing buildings in New York. Section 2 of this report describes the analysis methodology, including the building types and construction area weights update for this analysis, the baseline, and the method to conduct the energy saving analysis. Section 3 provides detailed specifications of the EEMs and bundles. Section 4 summarizes the results of individual EEMs and EEM bundles by building type, energy end-use and climate zone. Appendix A documents detailed descriptions of the selected prototype buildings. Appendix B provides energy end-use breakdown results by building type for both the baseline code and stretch code in all climate zones.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Final Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

This study was conducted by the Pacific Northwest National Laboratory (PNNL) in support of the stretch energy code development led by the New York State Energy Research and Development Authority (NYSERDA). In 2017 NYSERDA developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code (hereinafter referred to as “NYStretch-Energy”). NYStretch-Energy is intended as a model energy code for statewide voluntary adoption that anticipates other code advancements culminating in the goal of a statewide Net Zero Energy Code by 2028. Since then, NYSERDA continues to develop the NYStretch-Energy Code 2018 edition (NYSERDA 2018). To support the effort, PNNL conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code 2018 in New York. The focus of this project is to significantly improve the energy efficiency over existing commercial model energy codes. A key requirement of the proposed stretch code is that it be ‘adoptable’ as an energy code, meaning that it must align with current code scope and limitations, and primarily impact building components that are currently regulated by local building departments. It is largely limited to prescriptive measures, which are what most building departments and design projects are most familiar with. This report describes a set of energy-efficiency measures (EEMs) that demonstrate significant energy savings over ANSI/ASHRAE/IES Standard 90.1-2013 (ASHRAE 2013) across a broad range of commercial building types and all three climate zones in New York. In collaboration with New Building Institute, the EEMs were developed from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the on-going code development process. PNNL analyzed these measures using whole building energy models for selected prototype commercial buildings and multifamily buildings representing buildings in New York.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

2015 IECC: Energy Savings Analysis

Section 304(a) of the Energy Conservation and Production Act, as amended, requires the Secretary of Energy to make a determination each time a revised edition of the 1992 Model Energy Code (MEC), or any successor thereof, is published with respect to whether the revised code would improve energy efficiency in residential buildings. The International Energy Conservation Code (IECC), as administered by the International Code Council (ICC), establishes the national model code for energy efficiency requirements for residential buildings. The latest edition of the IECC, the 2015 IECC, was published on June 3, 2014 and forms the basis of this analysis. To meet these statutory requirements, as well as to assist states and adopting entities in understanding associated savings, the DOE Building Energy Codes Program and Pacific Northwest National Laboratory (PNNL) conduct analyses to evaluate the differences between the latest edition of the IECC and its immediate predecessor. A qualitative analysis is conducted, identifying all changes made to the previous edition of the IECC, and characterizing these changes in terms of their anticipated impact on residential building energy consumption. A quantitative analysis is then modeled through building energy simulation to estimate the resulting energy impacts. This report documents the technical analysis used to evaluate whether residential buildings constructed to meet the requirements of the 2015 IECC would result in energy efficiency improvements over residential buildings constructed to meet the requirements of the previous edition, the 2012 IECC. PNNL considered all code change proposals approved for inclusion in the 2015 IECC during the ICC code development cycle, and evaluated their combined impact on a suite of prototypical residential building energy models across all U.S. climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Scenario Documentation: Chiller Replacement

Building on a 3-year effort to calibrate and validate the U.S. Department of Energy's ResStock (TM) and ComStock (TM) models, this work produces national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual energy consumption (at a subhourly resolution) of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. The goal of this work is to develop energy efficiency and demand flexibility end-use load shapes that cover high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to various "what-if" scenarios that can be applied to buildings. An end-use savings shape is the difference in energy consumption between a baseline building (or collection of buildings) and a building with an energy efficiency or demand flexibility measure applied. It results in a time-series profile broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step, as well as annual aggregations. This report describes the modeling methodology for a single end-use savings shape measure - chiller replacement - and briefly introduces key results. The full public dataset can be accessed on the ComStock (TM) data lake or via the Data Viewer at comstock.nrel.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Scenario Documentation: Standard Performance Heat Pump Rooftop Unit With New Windows

Building on a 3-year effort to calibrate and validate the U.S. Department of Energy's ResStock (TM) and ComStock (TM) models, this work produces national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual energy consumption (at subhourly resolution) of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. The goal of this work is to develop energy efficiency and demand flexibility end-use load shapes that cover high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to various "what-if" scenarios that can be applied to buildings. An end-use savings shape is the difference in energy consumption between a baseline building (or collection of buildings) and a building with an energy efficiency or demand flexibility measure applied. It results in a time-series profile broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step, as well as annual aggregations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Medium- and Heavy-Duty Truck Duty Cycles

This dataset provides second-by-second duty cycle data for Class 6 and Class 8 diesel trucks in Texas, including key vehicle metrics, engine-related data, and GPS data (excluding GPS latitude and longitude to ensure confidentiality). The data were collected via tablets installed on the trucks and organized into daily datasets, each associated with a unique vehicle ID and date. There are 12 daily datasets for Class 6 diesel trucks (three unique vehicle IDs) and 43 daily datasets for Class 8 diesel trucks (six unique vehicle IDs). The units associated with each column are included in the name. The engine performance data include columns such as engine speed, engine percent torque, and engine fuel rate. Road grade (%/100) was estimated using the GPS altitude and wheel-based vehicle speed, which is used as an input for FASTSim. Cumulative distance was also calculated using the wheel-based vehicle speed. Additional columns include: - Engine Speed (RPM): Removed inaccurate readings and used to calculate angular velocity (radians/second). - Torque (N·m): Calculated using engine percent torque, nominal friction percent torque, and engine reference torque values (those columns were removed from dataset), then normalized to express as torque (%). - Flywheel Power (%): Calculated using the angular velocity and torque (in kW), then normalized as a percentage of the maximum value. - Engine Fuel Rate (%) and Torque (%): Both metrics were normalized by dividing by their respective maximum values within each dataset to express them as percentages. The datasets were analyzed to assess the energy impact of various driving behaviors, simulate energy efficiency, and recommend optimal routes for diesel trucks using NLR’s tool called RouteE. For driver coaching, factors like speed and acceleration limits were considered, and idle periods were reduced (assuming the engine was off during idling) to adjust each drive cycle. These adjusted drive cycles were then simulated in FASTSim to evaluate their effect on fleet energy consumption and estimate potential energy savings. The original cycles are available for download on this page ![image](CoVaR_Image_for_Data_Page_Kenworth_Truck.jpg)

1Hz↗

Effects of electron-phonon coupling and electronic thermal conductivity in high energy molecular dynamics simulations of irradiation cascades in nickel

The two-temperature model has been applied to investigate the effects of the electronic subsystem on 150 keV Ni ion cascades in nickel using molecular dynamics simulation. We explore the effects of the magnitude of the electron-phonon coupling and the electronic thermal conductivity on defect production and cluster formation. It has been found that stronger electron-phonon coupling allows larger and more rapid energy feedback to the atomic subsystem, leading to reduction of number of point defects and suppression of the formation of larger defect clusters. It was observed that larger electronic thermal conductivity results in slightly increased number of point defects and larger size vacancy clusters. The latter takes place because of suppression of point defects recombination in faster cooling areas of initial damage.

Zarkadoula, Eva↗

Validating Simulated Models of Energy Consumption by a Battery Electric Motorcoach: A real-world deployment in a harsh climate.

Many efforts have been made to simulate energy consumption of battery electric buses (BEBs) to optimize their deployment into existing fleets. The models produced, however, are rarely validated against real-world consumption data, limiting their generalizability and widespread application to fleets around the US. Furthermore, a major concern specific to BEBs is the effects of harsh climates on their performance. We build upon the state-of-the-art energy consumption modeling techniques developed for BEBs and apply them to a unique geographic context and a unique electrified vehicle. This geography, climate, and vehicle further the existing understanding of the factors affecting medium- and heavy-duty electric vehicles (MHDEVs) by allowing for new relationships to be tested and by assessing the generalizability of known relationships to new contexts. We find that temperature is less predictive of energy consumption for the battery electric motorcoach (BEM) in the case study environment than it is for BEBs in other studies. A mitigating factor that we presume to be working on the relationship between temperature and energy consumption is the fact that the BEM route does not stop between origin and destination to exchange passengers, and in turn, conditioned cabin air. Our model also incorporates wind speed and direction relative to travel, which is a novel contribution of our methodology. Results from our study are helpful for transit service planners, fleet operators, and logistics firms for improving their ability to predict performance of potential deployments of MHDEVs into existing operations.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

Simulation of radiation energy release in air showers

A simulation study of the energy released by extensive air showers in the form of MHz radiation is performed using the CoREAS simulation code. We develop an efficient method to extract this radiation energy from air-shower simulations. We determine the longitudinal profile of the radiation energy release and compare it to the longitudinal profile of the energy deposit by the electromagnetic component of the air shower. We find that the radiation energy corrected for the geometric dependence of the geomagnetic emission scales quadratically with the energy in the electromagnetic component of the air shower with a second-order dependence on the atmospheric density at the position of the maximum shower development X {sub max}. In a measurement where X {sub max} is not accessible, this second order dependence can be approximated using the zenith angle of the incoming direction of the air shower with only a minor loss in accuracy. Our method results in an intrinsic uncertainty of 4% in the determination of the energy in the electromagnetic air-shower component, which is well below current experimental uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving Air-Conditioner and Heat Pump Modeling (Presentation made at the Building America Stakeholders Meeting) [Slides]

A new approach to modeling residential air conditioners and heat pumps allows users to model systems by specifying only the more readily-available SEER/EER/HSPF-type metrics. Manufacturer data was used to generate full sets of model inputs for over 450 heat pumps and air conditioners. A sensitivity analysis identified which inputs can be safely defaulted 'behind-the-scenes' without negatively impacting the reliability of energy simulations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Verification and Validation of EnergyPlus Phase Change Material Model for Opaque Wall Assemblies

Phase change materials (PCMs) represent a technology that may reduce peak loads and HVAC energy consumption in buildings. A few building energy simulation programs have the capability to simulate PCMs, but their accuracy has not been completely tested. This study shows the procedure used to verify and validate the PCM model in EnergyPlus using a similar approach as dictated by ASHRAE Standard 140, which consists of analytical verification, comparative testing, and empirical validation. This process was valuable, as two bugs were identified and fixed in the PCM model, and version 7.1 of EnergyPlus will have a validated PCM model. Preliminary results using whole-building energy analysis show that careful analysis should be done when designing PCMs in homes, as their thermal performance depends on several variables such as PCM properties and location in the building envelope.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Online Tool for Preliminary Design and Techno-Economic Analysis of District Geothermal Heating and Cooling Systems

District geothermal heating and cooling systems (DGHCS) have significant benefits for reducing energy consumption as well as building- and grid-level peak electric demand. Currently, no publicly available tools are available to effectively design and conduct techno-economic analysis of DGHCS. GeoWISE was originally developed for preliminary design and techno-economic analysis of geothermal heating and cooling systems in an individual commercial or residential building. This paper introduces recent upgrades of GeoWISE that allow users to design and conduct techno-economic analysis of DGHCS. Several new features are implemented in GeoWISE to allow selection and specification of multiple new or existing buildings. A database of information for over 125 million existing U.S. buildings was used in GeoWISE that allows users easily locate existing buildings of interest based on street addresses, and optionally edit information of the buildings (e.g., footprint, vintage, principal functions, number of floors, window-to-wall ratio). Unique energy simulation models of the selected buildings are then automatically created using the Automatic Building Energy Modeling (AutoBEM) and EnergyPlus simulations are performed to predict thermal loads of the buildings. A simplified DGHCS is then designed and simulated to predict its energy use. A central borehole heat exchanger (BHE) of the DGHCS is sized using the RowWise algorithm of GHEDesigner to meet the thermal loads within user-specified land areas for installing BHE. The upgraded GeoWISE reports the needed capacity of heating and cooling equipment in each building, design of the central BHE, energy consumption reduction, and energy cost saving resulting from using DGHCS compared with conventional HVAC systems. A case study is showcased using the upgraded GeoWISE to design and conduct techno-economic analysis of a simplified DGHCS.

Prem Anand Jayaprabha, Jyothis Anand [ORNL] (ORCID↗

ComStock Measure Documentation: High-Efficiency Rooftop Unit

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - high-efficiency rooftop unit (RTU) - and briefly introduces key results. The full public data set can be accessed on the Comstock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Variable-Speed Pumps

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - variable speed pumps - and briefly introduces key results. The full public data set can be accessed on the ComStock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗