Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ENERGY RANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Measurements of the atmospheric neutron leakage rate

The atmospheric neutron leakage rate in the energy range from 0.01 to 10,000,000 eV has been measured as a function of latitude, altitude, and time with a neutron detector on board the Ogo 6 satellite. The latitude dependence of the neutron leakage is in reasonable agreement with that predicted by Lingenfelter (1963) and Light et al. (1973) if the neutron energy spectrum has the shape calculated by Newkirk (1963). The change in the neutron latitude dependence with the cosmic ray modulation agrees with the predictions of Lingenfelter and Light et al. For several solar proton events enhancements were observed in the neutron counting rates at lambda greater than or equal to 70 deg. Such events, however, provide an insignificant injection of protons at E less than or equal to 20 MeV into the radiation belts. An isotropic angular distribution of the neutron leakage in the energy range from 0.1 keV to 10 MeV best fits the observed altitude dependence of the neutron leakage flux.

Lockwood, J. A.↗

SS Cygni as a hard X-ray source identified with the scanning modulation collimator on HEAO 1

Hard X-ray emission from a 15 min by 1.5 deg area containing SS Cygni had previously been reported and identified with SS Cygni. This paper reports a 0.4 sq arc min measurement of the position of the X-ray source with the HEAO 1 modulation collimator experiment which leads to an unequivocal identification of SS Cygni as an X-ray emitter in the 2-10 keV energy range. The historical light curve in hard X-rays was also investigated by analyzing relevant Uhuru data, and two instances of possible source detection in the 2-6 keV band were noted. From Ariel 5 observations it is calculated that the X-ray luminosity of SS Cygni in the 2-10 keV energy range is of the order of 10 to the 33rd erg/sec in the optical low state and probably at least an order of magnitude less in the high state. By contrast, the soft X-ray luminosity increases by an order of magnitude between the optical low and high states. A coronal model or accretion onto the white dwarf can account for the inverse correlation of the soft and hard X-rays.

Fabbiano, G.↗

Particle-Tracking Proton Computed Tomography—Data Acquisition, Preprocessing, and Preconditioning

Proton CT (pCT) is a promising new imaging technique that can reconstruct relative stopping power (RSP) more accurately than x-ray CT in each cubic millimeter voxel of the patient. This, in turn, will result in better proton range accuracy and, therefore, smaller planned tumor volumes (PTV). The hardware description and some reconstructed images have previously been reported. In a series of two contributions, we focus on presenting the software algorithms that convert pCT detector data to the final reconstructed pCT images for application in proton treatment planning. There were several options on how to accomplish this, and we will describe our solutions at each stage of the data processing chain. In the first paper of this series, we present the data acquisition with the pCT tracking and energy-range detectors and how the data are preprocessed, including the conversion to the well-formatted track information from tracking data and water-equivalent path length from the data of a calibrated multi-stage energy-range detector. These preprocessed data are then used for the initial image formation with an FDK cone-beam CT algorithm. The output of data acquisition, preprocessing, and FDK reconstruction is presented along with illustrative imaging results for two phantoms, including a pediatric head phantom. The second paper in this series will demonstrate the use of iterative solvers in conjunction with the superiorization methodology to further improve the images resulting from the upfront FDK image reconstruction and the implementation of these algorithms on a hybrid CPU/GPU computer cluster.

42 ENGINEERING↗

Measurement of the photon beam asymmetry in γ → p → K + Σ 0 at E γ = 8.5 GeV

We report measurements of the photon beam asymmetry $\Sigma$ for the reaction $\vec{\gamma} p\to K^+\Sigma^0$(1193) using the GlueX spectrometer in Hall D at Jefferson Lab. Data were collected using a linearly polarized photon beam in the energy range of 8.2-8.8 GeV incident on a liquid hydrogen target. The beam asymmetry $\Sigma$ was measured as a function of the Mandelstam variable $t$, and a single value of $\Sigma$ was extracted for events produced in the $u$-channel. These are the first exclusive measurements of the photon beam asymmetry $\Sigma$ for the reaction in this energy range. For the $t$-channel, the measured beam asymmetry is close to unity over the $t$-range studied, $-t=(0.1-1.4)~$(GeV/$c$)$^{2}$, with an average value of $\Sigma = 1.00\pm 0.05$. This agrees with theoretical models that describe the reaction via the natural-parity exchange of the $K^{*}$(892) Regge trajectory. A value of $\Sigma = 0.41 \pm 0.09$ is obtained for the $u$-channel integrated up to $-u=2.0$~(GeV/$c$)$^{2}$.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Upgrades and redesign of the National Ignition Facility’s soft x-ray opacity spectrometer (OpSpec)

The soft x-ray Opacity Spectrometer (OpSpec) used on the National Ignition Facility (NIF) has recently incorporated an elliptically shaped crystal. The original OpSpec used two convex cylindrical crystals for time-integrated measurements of point-projection spectra from 540 to 2100 eV. However, with the convex geometry, the low-energy portion of the spectrum suffered from high backgrounds due to scattered x-rays as well as reflections from alternate crystal planes. An elliptically shaped crystal allows an acceptance aperture at the crossover focus between the crystal and the detector, which reduces background and eliminates nearly all reflections from alternate crystal planes. The current elliptical design is an improvement from the convex cylindrical design but has a usable energy range from 900 to 2100 eV. In addition, OpSpec is currently used on 18 NIF shots/year, in which both crystals are typically damaged beyond reuse, so efficient production of 36 crystals/year is required. Design efforts to improve the existing system focus on mounting reliability, reducing crystal strain to increase survivability between mounting and shot time, and extending the energy range of the instrument down to 520 eV. The elliptical design, results, and future options are presented.

Wallace, M. S. (ORCID:0000000310871216)↗

Transport analysis of measured neutron leakage spectra from spheres as tests of evaluated high energy cross sections

Integral tests of evaluated ENDF/B high-energy cross sections have been made by comparing measured and calculated neutron leakage flux spectra from spheres of various materials. An Am-Be (alpha,n) source was used to provide fast neutrons at the center of the test spheres of Be, CH2, Pb, Nb, Mo, Ta, and W. The absolute leakage flux spectra were measured in the energy range 0.5 to 12 MeV using a calibrated NE213 liquid scintillator neutron spectrometer. Absolute calculations of the spectra were made using version 3 ENDF/B cross sections and an S sub n discrete ordinates multigroup transport code. Generally excellent agreement was obtained for Be, CH2, Pb, and Mo, and good agreement was observed for Nb although discrepancies were observed for some energy ranges. Poor comparative results, obtained for Ta and W, are attributed to unsatisfactory nonelastic cross sections. The experimental sphere leakage flux spectra are tabulated and serve as possible benchmarks for these elements against which reevaluated cross sections may be tested.

Bogart, D. D.↗

Observations of the hard X-ray spectrum of the impulsive phase of solar flares

The impulsive solar hard X-ray spectrum provides a direct diagnostic on the impulsive energy release of the flare. The data from the hard X-ray (14-342 keV) spectrometer on OSO 7 have been examined for events covering a wide energy range to determine the photon spectrum more precisely. This resulted in a sample of 38 events. The data have been fitted with either single- or double-power laws, and with an exponential spectrum, as from thermal bremsstrahlung. The chi-squared statistic between two-parameter fits strongly favors the exponential fit, particularly at peak intensity when the widest energy range is sampled. This result supports a single-temperature thermal source of the impulsive solar hard X-rays with temperatures in the range 4.7-31 keV and emission measures in the range from 8.4 x 10 to the 43rd to 6.0 x 10 to the 46th per cu cm. The temperature reaches a single maximum and then rapidly decays, but the emission measure usually increases throughout, even after temperature maximum, for data with 10-s resolution.

Elcan, M. J.↗

Energy Spectra, Composition, and Other Properties of Ground-Level Events During Solar Cycle 23

We report spacecraft measurements of the energy spectra of solar protons and other solar energetic particle properties during the 16 Ground Level Events (GLEs) of Solar Cycle 23. The measurements were made by eight instruments on the ACE, GOES, SAMPBX, and STEREO spacecraft and extend from approximately 0.1 to approximately 500-700 MeV. All of the proton spectra exhibit spectral breaks at energies ranging from approximately 2 to approximately 46 MeV and all are well fit by a double power-law shape. A comparison of GLE events with a larger sample of other solar energetic particle (SEP) events shows that the typical spectral indices are harder in GLE events, with a mean slope of -3.18 at greater than 40 MeV/nuc. In the energy range 45 to 80 MeV/nucleon about approximately 50% of GLE events have properties in common with impulsive He-3-rich SEP events, including enrichments in Ne/O, Fe/O, Ne-22/Ne-20, and elevated mean charge states of Fe. These He-3 rich events contribute to the seed population accelerated by CME-driven shocks. An analysis is presented of whether highly-ionized Fe ions observed in five events could be due to electron stripping during shock acceleration in the low corona. Making use of stripping calculations by others and a coronal density model, we can account for events with mean Fe charge states of (Q(sub Fe) is approximately equal to +20 if the acceleration starts at approximately 1.24-1.6 solar radii, consistent with recent comparisons of CME trajectories and type-II radio bursts. In addition, we suggest that gradual stripping of remnant ions from earlier large SEP events may also contribute a highly-ionized suprathermal seed population. We also discuss how observed SEP spectral slopes relate to the energetics of particle acceleration in GLE and other large SEP events.

Mewaldt, R. A.↗

Stochastic reacceleration of cosmic rays in the interstellar medium

The effects of reacceleration on cosmic rays have been studied over a wide charge and energy range using a model of reacceleration by the interstellar turbulence. We take into account only inevitable stochastic reacceleration of cosmic rays by the random hydrodynamic waves, which supposedly exist in the interstellar medium and provide a means for cosmic-ray scattering and spatial diffusion in the Galaxy. Our calculations reproduce not only the B/C ratio but also the H and He data over the entire energy range where the measurements are available. However, the sub-Fe to Fe ratio is not fitted as well as the B/C ratio, and the reacceleration effect does not seem to remove the need for truncation of short path lengths, which is apparently required by the standard leaky box model. This work demonstrates that the cosmic-ray data can be represented at least as well by a reacceleration model with a simple rigidity power-law escape length, which agrees with the Kolmogorov-type spectrum of hydromagnetic turbulence, as they can by the standard leaky box model with its ad hoc escape lengths.

Seo, E. S.↗

Selection of a Pair of Experiments to Optimally Reduce Uncertainty in Targeted Nuclear Data

We propose a novel process to select a pair of differential and integral experiments that best reduce uncertainties in targeted 239 ⁢Pu nuclear data while compressing the current nuclear data pipeline from 20 to 3 years. 239⁢ Pu nuclear data are poorly understood for neutrons in the intermediate energy range due to sparsity and uncertainty in historical experiments. New experiments targeting this range will enable better understanding of these nuclear data, but choosing the ideal experiments to conduct is challenging. Beginning with a prior distribution represented by samples of nuclear data generated from theory, generalized least squares adjustments are made to incorporate data from historical experiments. To quantify potential uncertainty reduction obtainable from a pair of candidate experiments, we compute the D-optimality criterion of the posterior covariance of intermediate energy range nuclear data compared to the equivalent covariance after additional adjustment to the pair of candidate experiments. Repeating the process for each of many candidate pairs facilitates the final selection. Results support 63⁢ Cu total cross section measurements for differential experiments and alumina and alumina/graphite configurations for integral experiments. This analysis enables choosing differential and integral experiments to be executed concurrently while shortening decision times relative to the current nuclear data pipeline.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modification of codes NUALGAM and BREMRAD, Volume 1

The NUGAM2 code predicts forward and backward angular energy differential and integrated distributions for gamma photons and fluorescent radiation emerging from finite laminar transport media. It determines buildup and albedo data for scientific research and engineering purposes; it also predicts the emission characteristics of finite radioisotope sources. The results are shown to be in very good agreement with available published data. The code predicts data for many situations in which no published data is available in the energy range up to 5 MeV. The NUGAM3 code predicts the pulse height response of inorganic (NaI and CsI) scintillation detectors to gamma photons. Because it allows the scintillator to be clad and mounted on a photomultiplier as in the experimental or industrial application, it is a more practical and thus useful code than others previously reported. Results are in excellent agreement with published Monte Carlo and experimental data in the energy range up to 4.5 MeV.

Steyn, J. J.↗

First Flight of the Gamma-Ray Imager Polarimeter for Solar Flares (GRIPS) Instrument

The Gamma-Ray Imager/Polarimeter for Solar ares (GRIPS) instrument is a balloon-borne telescope designed to study solar-flare particle acceleration and transport. We describe GRIPS's first Antarctic long-duration flight in January 2016 and report preliminary calibration and science results. Electron and ion dynamics, particle abundances and the ambient plasma conditions in solar flares can be understood by examining hard X-ray (HXR) and gamma-ray emission (20 keV to 10 MeV). Enhanced imaging, spectroscopy and polarimetry of flare emissions in this energy range are needed to study particle acceleration and transport questions. The GRIPS instrument is specifically designed to answer questions including: What causes the spatial separation between energetic electrons producing hard X-rays and energetic ions producing gamma-ray lines? How anisotropic are the relativistic electrons, and why can they dominate in the corona? How do the compositions of accelerated and ambient material vary with space and time, and why? GRIPS's key technological improvements over the current solar state of the art at HXR/gamma-ray energies, the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI), include 3D position-sensitive germanium detectors (3D-GeDs) and a single-grid modulation collimator, the multi-pitch rotating modulator (MPRM). The 3D-GeDs have spectral FWHM resolution of a few hundred keV and spatial resolution less than 1cu mm. For photons that Compton scatter, usually greater or equal to 150 keV, the energy deposition sites can be tracked, providing polarization measurements as well as enhanced background reduction through Compton imaging. Each of GRIPS's detectors has 298 electrode strips read out with ASIC/FPGA electronics. In GRIPS's energy range, indirect imaging methods provide higher resolution than focusing optics or Compton imaging techniques. The MPRM grid-imaging system has a single-grid design which provides twice the throughput of a bi-grid imaging system like RHESSI. The grid is composed of 2.5 cm deep tungsten-copper slats, and quasi-continuous FWHM angular coverage from 12.5-162 arcsecs are achieved by varying the slit pitch between 1-13 mm. This angular resolution is capable of imaging the separate magnetic loop footpoint emissions in a variety of are sizes. In comparison, RHESSI's 35-arcsec resolution at similar energies makes the footpoints resolvable in only the largest ares.

Duncan, Nicole↗

The effect of autoionization on the HBr + X 2 Π 3/2,1/2 state photoelectron angular distributions

A double-imaging photoelectron-photoion spectrometer and synchrotron radiation have been used to measure the HBr + X 2 Π 3/2 v + = 0, 1, 2 and the 2 Π 1/2 v + = 0 state photoelectron angular distributions, as characterized by the anisotropy parameter β , the total ion yield, and the threshold photoelectron spectrum. Particular attention has been focussed on the photon energy range between the 2 Π 3/2 and the 2 Π 1/2 spin–orbit components of the ground ionic state. This region encompasses Rydberg states, belonging to series converging onto the upper 2 Π 1/2 ionization limit, which may decay by autoionization into the 2 Π 3/2 ionization continuum. A detailed study has been performed on the effects of autoionization on the 2 Π 3/2 v + = 0 state photoelectron angular distributions. Furthermore, the observed energy dependent variations in the β -values exhibit a regular pattern that correlates with excitation into members of a very broad d-type Rydberg series. Additional rapid variations in the β -parameters, which occur over a narrow energy range, appear to coincide with sharp autoionizing Rydberg states belonging to s, p and d series. The present experimental results for the HBr + X 2 Π 3/2 v + = 0 state photoelectron anisotropy parameter are compared to previously reported theoretical predictions and to earlier studies of the Kr + 4p 5 2 P 3/2 state β -parameter. The threshold photoelectron spectrum of the X 2 Π 3/2 v + = 0 band exhibits partially resolved rotational structure. A simulation of this structure yields an ionization threshold of 11.6673 ± 0.0010 eV, which is consistent with previous measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Conceptual design report: a ring-based electron cooling system for the EIC

This report describes a concept of an EIC cooling system, based on a proven induction-linac technology with a DC electron beam. The system would operate in a full energy range of proton beams (100–270 GeV) and would provide 50–100 A electron beams, circulating in a cooler ring for 5 ms. Every 5 ms a new electron pulse would be injected into the cooler ring to provide continuous cooling at collisions. Operations with a 10-ms cycle is possible but it will reduce the cooling rates by ~30%. The system is capable of delivering the required performance in the entire EIC energy range with emittance cooling times of less than 1–2 hours.

43 PARTICLE ACCELERATORS↗

Limits on Astrophysical Antineutrinos with the KamLAND Experiment

Abstract We report on a search for electron antineutrinos ( ν ¯ e ) from astrophysical sources in the neutrino energy range 8.3–30.8 MeV with the KamLAND detector. In an exposure of 6.72 kton-year of the liquid scintillator, we observe 18 candidate events via the inverse beta decay reaction. Although there is a large background uncertainty from neutral current atmospheric neutrino interactions, we find no significant excess over background model predictions. Assuming several supernova relic neutrino spectra, we give upper flux limits of 60–110 cm −2 s −1 (90% confidence level, CL) in the analysis range and present a model-independent flux. We also set limits on the annihilation rates for light dark matter pairs to neutrino pairs. These data improve on the upper probability limit of 8 B solar neutrinos converting into ν ¯ e , P ν e → ν ¯ e < 3.5 × 10 − 5 (90% CL) assuming an undistorted ν ¯ e shape. This corresponds to a solar ν ¯ e flux of 60 cm −2 s −1 (90% CL) in the analysis energy range.

79 ASTRONOMY AND ASTROPHYSICS↗

The calculation of radial dose from heavy ions: predictions of biological action cross sections

The track structure model of heavy ion cross sections was developed by Katz and co-workers in the 1960s. In this model the action cross section is evaluated by mapping the dose-response of a detector to gamma rays (modeled from biological target theory) onto the radial dose distribution from delta rays about the path of the ion. This is taken to yield the radial distribution of probability for a "hit" (an interaction leading to an observable end-point). Radial integration of the probability yields the cross section. When different response from ions of different Z having the same stopping power is observed this model may be indicated. Since the 1960s there have been several developments in the computation of the radial dose distribution, in the measurement of these distributions, and in new radiobiological data against which to test the model. The earliest model, by Butts and Katz made use of simplified delta ray distribution functions, of simplified electron range-energy relations, and neglected angular distributions. Nevertheless it made possible the calculation of cross sections for the inactivation of enzymes and viruses, and allowed extension to tracks in nuclear emulsions and other detectors and to biological cells. It set the pattern for models of observable effects in the matter through which the ion passed. Here we outline subsequent calculations of radial dose which make use of improved knowledge of the electron emission spectrum, the electron range-energy relation, the angular distribution, and some considerations of molecular excitation, of particular interest both close to the path of the ion and the outer limits of electron penetration. These are applied to the modeling of action cross sections for the inactivation of several strains of E-coli and B. subtilis spores where extensive measurements in the "thin-down" region have been made with heavy ion beams. Such calculations serve to test the radial dose calculations at the outer limit of electron penetration. We lack data from which to test these calculations in regions close to the path of the ion aside from our earliest work on latent tracks in plastics, though it appears that the criterion then suggested for the threshold of track formation, of a minimal dose at a minimal distance (of about 20 angstroms, in plastics), remains valid.

NASA Discipline Radiation Health↗

High-spatial resolution and high-spectral resolution detector for use in the measurement of solar flare hard X-rays

In the areas of high spatial resolution, the evaluation of a hard X-ray detector with 65 micron spatial resolution for operation in the energy range from 30 to 400 keV is proposed. The basic detector is a thick large-area scintillator faceplate, composed of a matrix of high-density scintillating glass fibers, attached to a proximity type image intensifier tube with a resistive-anode digital readout system. Such a detector, combined with a coded-aperture mask, would be ideal for use as a modest-sized hard X-ray imaging instrument up to X-ray energies as high as several hundred keV. As an integral part of this study it was also proposed that several techniques be critically evaluated for X-ray image coding which could be used with this detector. In the area of high spectral resolution, it is proposed to evaluate two different types of detectors for use as X-ray spectrometers for solar flares: planar silicon detectors and high-purity germanium detectors (HPGe). Instruments utilizing these high-spatial-resolution detectors for hard X-ray imaging measurements from 30 to 400 keV and high-spectral-resolution detectors for measurements over a similar energy range would be ideally suited for making crucial solar flare observations during the upcoming maximum in the solar cycle.

Desai, U. D.↗

Experiments to Measure the Effect of Tantalum on Critical Systems

Sandia National Laboratories (SNL) and Oak Ridge National Laboratory (ORNL) collaborated to develop a capability to test the epithermal/intermediate cross sections of materials at the SNL critical experiment facility using the Seven Percent Critical Experiment (7uPCX) fuel. As a result, a new set of critical experiments has been designed to target the epithermal cross sections of tantalum (Ta) and is scheduled to be performed at SNL in 2023. These critical experiments will be evaluated for inclusion in the 2024 edition of the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The focus of these critical experiments is to measure the effects of Ta on the critical array size. The critical array size will be determined by an approach-to-critical experiment with the number of fuel rods in the array as a free parameter. The core configurations are designed to optimize the reactivity worth of Ta and the overall percentage of Ta absorption rates in the epithermal/intermediate energy range (0.625 eV – 100 keV). The baseline core configuration includes 7uPCX fuel rods set at a triangular pitch of 1.016 cm and a central dry test region that utilizes a cadmium liner for filtering out thermal neutrons. The central test region has locations for 85 Ta rods set at a triangular pitch of 0.813 cm. The Ta reactivity worth for the case with 85 Ta rods is approximately 2.55%, with the percentage of Ta absorption rates within the intermediate energy range at nearly 90%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗