Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EFFICIENCY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Simulation of Fluid Flow and Collection Efficiency for a SEA Inc. Multi-Element Probe and Ice Crystal Detector Using GlennICE

Numerical simulation results of fluid flow and collection efficiency of the Science Engineering Associates Inc. Multi-Element Probe (Multiwire) and Ice Crystal Detector (ICD) are presented. Fluid flow simulations were conducted using NASA's FUN3D while collection efficiency simulations were conducted using NASA's LEWICE3D software and GlennICE software. For both probes, 3D unsteady flow results were time averaged. Simulations were computed for freestream velocities ranging from 85 to 185 m/s and freestream total pressures of 44.8 and 93.1 kPa. Collection efficiency results were computed for four spherical particle diameter sizes of 5, 20, 50, and 100 µm. GlennICE collection efficiency results for the multiwire were compared with previously published collection efficiency values calculated using LEWICE3D. Numerical collection efficiency results for the Ice Crystal Detector are presented for the first time.

aircraft, icing, Computational Fluid Dynamics↗

Efficient Active Learning for Gaussian Process Classification by Error Reduction

Active learning sequentially selects the best instance for labeling by optimizing an acquisition function to enhance data/label efficiency. The selection can be either from a discrete instance set (pool-based scenario) or a continuous instance space (query synthesis scenario). In this work, we study both active learning scenarios for Gaussian Process Classification (GPC). The existing active learning strategies that maximize the Estimated Error Reduction (EER) aim at reducing the classification error after training with the new acquired instance in a onestep-look-ahead manner. The computation of EER-based acquisition functions is typically prohibitive as it requires retraining the GPC with every new query. Moreover, as the EER is not smooth, it can not be combined with gradient-based optimization techniques to efficiently explore the continuous instance space for query synthesis. To overcome these critical limitations, we develop computationally efficient algorithms for EER-based active learning with GPC. Further, we derive the joint predictive distribution of label pairs as a one-dimensional integral, as a result of which the computation of the acquisition function avoids retraining the GPC for each query, remarkably reducing the computational overhead. We also derive the gradient chain rule to efficiently calculate the gradient of the acquisition function, which leads to the first query synthesis active learning algorithm implementing EER-based strategies. Our experiments clearly demonstrate the computational efficiency of the proposed algorithms. We also benchmark our algorithms on both synthetic and real-world datasets, which show superior performance in terms of sampling efficiency compared to the existing state-of-the-art algorithms.

97 MATHEMATICS AND COMPUTING↗

Efficiency Improvement Progress in Green, Yellow and Red III Nitride LEDs

Large improvements in the efficiencies of visible light emitting diodes (LEDs) have been realized over the last decade. Extending the range of wavelengths over which efficient emission can be realized continues to be a goal of active research. Efficiency droop refers to a non-thermal decrease in internal quantum efficiency with increasing current density that affects III-nitride LEDs in general, but more severely those with longer emission wavelengths. The so-called green gap is mainly related to the wavelength dependence of efficiency droop. The peak EQE in commercial green LEDs exceeds 60% but corresponds to a current density that is an order of magnitude lower than required for applications. In this presentation, we will review some of the underlying physics that contribute to the wavelength dependence of droop. We will discuss some challenges in the development of long wavelength III-nitride LEDs and possible strategies to mitigate efficiency droop based on the understanding that nonradiative Auger recombination is the root cause. One general strategy is to engineer the multi-quantum well active region to minimize the average carrier density. Another approach is to design wells with a more favorable balance between the radiative and Auger coefficients. Finally, we will present the current status of the performance of green, yellow and red III-Nitride LEDs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Determining the bubble nucleation efficiency of low-energy nuclear recoils in superheated C$_3$F$_8$ dark matter detectors

The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. The PICO Collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C$_3$F$_8$ from calibration data taken with 5 distinct neutron spectra at various thermodynamic thresholds ranging from 2.1 keV to 3.9 keV. Instead of assuming any particular functional forms for the nuclear recoil efficiency, a generalized piecewise linear model is proposed with systematic errors included as nuisance parameters to minimize model-introduced uncertainties. A Markov-Chain Monte-Carlo (MCMC) routine is applied to sample the nuclear recoil efficiency for fluorine and carbon at 2.45 keV and 3.29 keV thermodynamic thresholds simultaneously. The nucleation efficiency for fluorine was found to be $\geq 50\, \%$ for nuclear recoils of 3.3 keV (3.7 keV) at a thermodynamic Seitz threshold of 2.45 keV (3.29 keV), and for carbon the efficiency was found to be $\geq 50\, \%$ for recoils of 10.6 keV (11.1 keV) at a threshold of 2.45 keV (3.29 keV). Simulated data sets are used to calculate a p-value for the fit, confirming that the model used is compatible with the data. The fit paradigm is also assessed for potential systematic biases, which although small, are corrected for. Additional steps are performed to calculate the expected interaction rates of WIMPs in the PICO-60 detector, a requirement for calculating WIMP exclusion limits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance Assessment of High-Efficiency Refrigerated Display Cases with Low-GWP Refrigerants: Preprint

As California policy makers enforce new regulations such as SB 1383 to achieve state greenhouse gas (GHG) reduction goals, it will be critical to understand the energy efficiency implications of low global warming potential (GWP) refrigerants in commercial refrigeration applications. The goal of this research project, funded by Commonwealth Edison was to assess the energy performance of two high efficiency medium-temperature, self-contained, reach-in display cases that utilized natural refrigerant propane (R-290), and hydrofluorocarbon (HFC) drop-in hydrofluoroolefin R-513a, respectively. Performance of these display cases were compared to a baseline fixture using HFC (R-134a) under equal conditions in a controlled environment chamber. These display cases were selected due to their widespread use in convenience stores, and small supermarkets. The high efficiency cases were equipped with energy efficient lighting, improved panel insulation, high efficiency evaporator and condenser fan motors, and high effectiveness heat exchangers. The test method used in this project was foundationally inspired by the ANSI/ASHRAE 72-2018 standard method to evaluate each case under equivalent conditions. However, minor modifications to this methodology were implemented to better represent more realistic operation of the units. While maintaining target product temperature, the energy efficient fixtures containing R-290 and R-513a consumed 61.8% to 32.6% less energy, respectively, than a baseline case using R-134a refrigerant. The daily energy consumption of the R-290, R-513a, and baseline display cases at the upper limit of environmental conditions was 4.30, 7.59, and 11.26 kWh/day, respectively.

alternative refrigerants↗

Enhanced carbon-transfer and -utilization efficiencies achieved using membrane carbonation with gas sources having a range of CO 2 concentrations

The economic viability of microalgal biofuels relies on increasing productivity in a cost-effective manner. As microalgal biomass contains > 50% carbon, a high rate of CO 2 delivery is required for high productivity, and inefficient CO 2 delivery amplifies operating costs. Membrane carbonation using non-porous hollow fiber membranes can ideally deliver CO 2 without bubble formation and high carbon transfer efficiency. Because CO 2 streams from industrial resources are not 100% CO 2 , the buildup of inert gasses can significantly lower the CO 2 delivery rate when the distal end of the membrane is closed. To overcome the buildup of inert gases, we managed the distal end of the membranes with three different approaches: fully open end, restricted bleed valve, and restricted bleed valve with pH-actuated venting. For all approaches, CO 2 was delivered to membranes ondemand based on a pH set point. Evaluating a wide range of CO 2 concentrations (10% to 100%), we found that all approaches eliminated the buildup of inert gases, could maintain target pH values and gave the same biomass productivities and carbon distributions. However, carbon transfer efficiency depended on the operation of the distal end. Fully open-end operation gave a poor carbon transfer efficiency because of excessive loss of CO 2 from the distal end. However, restricting the exit flow rate to ≤4 cm 3 /min mitigated the problems of excessive CO 2 loss, but without incurring a large loss of CO 2 -delivery flux. For the continuous cultivation, combining a restricted bleed valve with pH-actuated venting improved the carbon-transfer efficiency and -utilization efficiencies up to 85% and 67%, respectively, with a sufficient CO 2 delivery flux.

42 ENGINEERING↗

US building energy efficiency and flexibility as an electric grid resource

Buildings consume 75% of U.S. electricity; therefore, improving the efficiency and flexibility of building operations could increase the reliability and resilience of the rapidly-changing electricity system. We estimate the technical potential near- and long-term impacts of best available building efficiency and flexibility measures on annual electricity use and hourly demand across the contiguous U.S. Co-deployment of building efficiency and flexibility avoids up to 742 TWh of annual electricity use and 181 GW of daily net peak load in 2030, rising to 800 TWh and 208 GW by 2050; at least 59 GW and 69 GW of the peak reductions are dispatchable. Implementing efficiency measures alongside flexibility measures reduces the potential for off-peak load increases, underscoring limitations on load shifting in efficient buildings. Overall, however, we find a substantial building-grid resource that could reduce future fossil-fired generation needs while also reducing dependence on energy storage with increasing variable renewable energy penetration.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Low temperature absolute internal quantum efficiency of InGaN-based light-emitting diodes

A method to reveal low temperature absolute internal quantum efficiency of an InGaN-based light-emitting diode (LED) is reported. Structural (via scanning electron and atomic force microscopies, x-ray diffraction, and Raman spectroscopy) and optical (via temperature- and power-dependent photoluminescence) properties of InGaN-based blue LEDs are coupled with a channel-based recombination model, which reveals the low temperature absolute internal quantum efficiency of the LED on traditional sapphire and emerging Si (111) substrates as 27.5% and 71.1%, respectively. High low-temperature absolute internal quantum efficiency of the former is attributed to its lower defect density and less strain. Furthermore, our results show assuming perfect (i.e., 100%) internal quantum efficiency in an InGaN-based LED at low temperatures could be misleading, and using negative thermal quenching properties of defect luminesce bands with a channel-based recombination model can be a method to quantify LED's less than ideal low temperature internal quantum efficiencies.

36 MATERIALS SCIENCE↗

The Genetic Architecture of Nitrogen Use Efficiency in Switchgrass ( Panicum virgatum L.)

Switchgrass (Panicum virgatum L.) has immense potential as a bioenergy crop with the aim of producing biofuel as an end goal. Nitrogen (N)-related sustainability traits, such as nitrogen use efficiency (NUE) and nitrogen remobilization efficiency (NRE), are important factors affecting switchgrass quality and productivity. Hence, it is imperative to develop nitrogen use-efficient switchgrass accessions by exploring the genetic basis of NUE in switchgrass. For that, we used 331 diverse field-grown switchgrass accessions planted under low and moderate N fertility treatments. We performed a genome wide association study (GWAS) in a holistic manner where we not only considered NUE as a single trait but also used its related phenotypic traits, such as total dry biomass at low N and moderate N, and nitrogen use index, such as NRE. We have evaluated the phenotypic characterization of the NUE and the related traits, highlighted their relationship using correlation analysis, and identified the top ten nitrogen use-efficient switchgrass accessions. Our GWAS analysis identified 19 unique single nucleotide polymorphisms (SNPs) and 32 candidate genes. Two promising GWAS candidate genes, caffeoyl-CoA O-methyltransferase (CCoAOMT) and <alfin-like 6(AL6), were further supported by linkage disequilibrium (LD) analysis. Finally, we discussed the potential role of nitrogen in modulating the expression of these two genes. Our findings have opened avenues for the development of improved nitrogen use-efficient switchgrass lines.

59 BASIC BIOLOGICAL SCIENCES↗

Variable-Speed Pump Efficiency Calculation For Fluid Flow Systems with and without Static Head

To accurately calculate pump energy savings gained from implementing variable frequency drive (VFD) controls, the variation of pump efficiency must be considered when operating conditions transition from the design operating point to new operating points. Many software tools require users to specify the new pump efficiency, or it is assumed to be unchanged. Unfortunately, many users have challenges of estimating the pump efficiency at new operating points. This paper presents a simplified method of estimating centrifugal pump efficiency at new operating speeds when the pump is controlled by a VFD. This methodology applies to systems with and without static head when the system curve is not affected by the change, and also systems where the change in operation changes the system curve.A hypothetical fluid flow system and centrifugal pump were used to demonstrate the calculation process for these scenarios. For this hypothetical system, the pump’s efficiency at new operating points was up to 5.4% lower than the design operating point.

42 ENGINEERING↗

Polymerized Small Molecular Acceptor with Branched Side Chains for All Polymer Solar Cells with Efficiency over 16.7%

The power conversion efficiencies (PCEs) of small molecule acceptor (SMA)-based organic solar cells have already exceeded 18%. However, the development of polymer acceptors still lags far behind their SMA counterparts mainly due to the lack of efficient polymer acceptors. In this work, a series of polymer acceptors named PY-X (with X being the branched alkyl chain) are designed and synthesized by employing the same central core with the SMA L8-BO but with different branched alkyl chains on the pyrrole motif. It is found that the molecular packing of SMA-HD featuring 2-hexyldecyl side chain used in the synthesis of PY-HD is similar to L8-BO, in which the branched alkyl chains lead to condensed and high-order molecular assembly in SMA-HD molecules. When combined with PM6, PY-HD-based all polymer solar cell (all-PSC) exhibits a high PCE of 16.41%, representing the highest efficiency for the binary all-PSCs. Moreover, the side-chain modification on the pyrrole site position further improves the performance of the all-PSCs, and the PY-DT-based device delivers a new record high efficiency of 16.76% (certified as 16.3%). The work provides new insights for understanding the structure–property relationship of polymer acceptors and paves a feasible avenue to develop efficient conjugated polymer acceptors.

14 SOLAR ENERGY↗

High-efficiency single-junction p-i-n GaAs solar cell on roll-to-roll epi-ready flexible metal foils for low-cost photovoltaics

We demonstrate the fabrication and characterization of high-efficiency, single-junction p-i-n GaAs solar cells, on flexible metal foil with epi-ready buffer via roll-to-roll fabrication. Single-junction p-i-n GaAs solar cells were fabricated using metal–organic chemical vapor deposition (MOCVD). Furthermore, an efficiency greater than 13% was obtained at 1 sun, which is the highest reported efficiency on GaAs photovoltaics directly deposited on metal tapes. This exceeds our previously reported study showcasing 11.5% efficiency on single-junction p-n solar cell structure. Improved morphology of p-i-n structure compared with p-n is explained by atomic force microscopy (AFM), scanning electron microscopy (SEM), and helium ion microscopy (HIM) measurements. Time-of-flight secondary ion mass spectrometry (TOF-SIMS) analysis showed reduced Zn diffusion in p-i-n cell compared with the p-n cell. We attribute the improvement in efficiency of p-i-n cells on flexible metal tapes to the quality of the junction, surface morphology, controlled diffusion of species within the active layers, and increase in absorption due to the optimized intrinsic layer thickness.

14 SOLAR ENERGY↗

Expert and operator perspectives on barriers to energy efficiency in data centers

Abstract It was last estimated in 2016 that data centers (DCs) comprise approximately 2% of total US electricity consumption. However, this estimate is currently being updated to account for the massive increase in computing needs due to streaming, cryptocurrency, and artificial intelligence (AI). To prevent energy consumption that tracks with increasing computing needs, it is imperative we identify energy efficiency strategies and investments beyond the low-hanging fruit solutions. In a two-phased research approach, we ask: What non-technical barriers still impede energy efficiency (EE) practices and investments in the data center sector, and what can be done to overcome these barriers? In particular, we are focused on social and organizational barriers to EE. In Phase I, we performed a literature review and found that technical solutions are abundant in the literature, but fail to address the top-down cultural shifts that need to take place in order to adapt new energy efficiency strategies. In Phase II, reported here, we interviewed 16 data center operators/experts to ground-truth our literature findings. Our interview protocols focus on three aspects of DC decision-making: procurement practices, metrics and monitoring, and perceived barriers to energy efficiency. We find that vendors are the key drivers of procurement decisions, advanced efficiency metrics are facility-specific, and there is convergence in the design of advanced facilities due to the heat density of parallelized infrastructure. Our ultimate goals for our research are to design DC decarbonization policies that target organizational structure, empower individual staff, and foster a supportive external market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An experimental study on round-trip efficiency of a preheating control with a medium office building

The interactions between building energy efficiency and demand response (DR) with buildings may complicate their impacts on the electricity grid and buildings, yet those interactions are not well understood. This work fills this gap by presenting an experimental study that quantifies the effects of DR on building energy efficiency. Unlike existing studies, this work 1) investigates the uncertainty levels when assessing the effects of DR; 2) studies the impact of rooftop heat pumps with direct expansion refrigerant-to-air coils on the round-trip efficiency. Specifically, we considered a medium office building (~1860 m 2 ), which is served by rooftop units, located in eastern Washington State. We performed preheating control tests during typical heating days in the year 2022 and compared the building’s energy consumption during the testing days to that during normal operation days under similar weather conditions. To understand how well those normal operation days represent the baseline for the assessment, the relationship between the energy performance of this building and weather conditions was also studied. Experimental results reveal that the round-trip efficiency (i.e., the ratio of discharging energy output from the building to charging energy input into the building) was between 0.16 and 0.92. The results show that significant energy loss may occur during the preheating process. Finally, it also suggests a significant correlation between the energy efficiency of the studied building under the preheating control and the outdoor temperature; and a highly nonlinear relationship between the zone temperature changing rate and the weather condition.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wickability-optimized textured liquid-desiccant air dehumidifiers for independent moisture management in energy-efficient buildings

Liquid-desiccant-based air conditioning systems are envisioned to enable independent humidity management, thereby improving the energy efficiency of future buildings. Existing liquid-desiccant-based air conditioning concepts, however, suffer from a poor liquid flow distribution deteriorating moisture removal rate. They are consequently flooded with the liquid-desiccant solution, which significantly degrades the energy efficiency of the dehumidification process. Here, in this work, the capillary forces and wickability effect of textured air dehumidifier surfaces are altered to minimize the liquid-desiccant flow rate of the fully wetted state, thereby transforming the physics of interfacial desiccant flow distribution. Consequently, the wickability-optimized air dehumidifier surface maximizes both moisture removal rate and dehumidification energy efficiency. It was interestingly found that the length scale of a textured air dehumidifier surface concept is optimized at an intermediate pattern density. Dry solid-air menisci appear at length scales exceeding the optimum pattern distance while the effective liquid–air interfacial area is reduced at smaller length scales, both of which degrade the moisture removal rate. At the optimum pattern density, the effective liquid–air interfacial area increases with the solution flow rate, thereby increasing the dehumidification rate. At a water vapor pressure potential of 3 kPa and a solution flow rate of 2.8 g/s, experimental results indicated a moisture removal rate of 0.16 g/m2-s for a textured surface concept with a capillary length scale of 3 mm, a 28% improvement compared with that of smooth-plate dehumidifier surfaces. A high moisture removal rate of the textured surface at a low desiccant flow rate led to a high thermal efficiency of 0.75 at a water vapor pressure potential of 5.6 kPa and a LiBr flow rate of 2.8 g/s. The insights gained from the present study accelerate the development of advanced textured surface concepts for next-generation liquid-desiccant-based air dehumidification systems offering independent humidity management for future energy-efficient buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing hydrogen supply chains: An integrated review of leakage and energy efficiency studies

This paper examines hydrogen leakage and efficiency across the supply chain for liquid, gaseous, and mixed hydrogen systems. These factors are crucial for assessing hydrogen's role in mitigating emissions and facilitating a clean energy transition. Drawing on a comprehensive review of existing literature and model-based analysis, the study compiles leakage rates and efficiency metrics at each stage of the supply chain: production, storage, transmission, distribution, and end-use. These data inform system scenarios that estimate the impact of leakage on overall performance and climate benefits. The analysis also identifies persistent data gaps, particularly for liquid and mixed system configurations, and outlines priorities for future research. A comparison of hydrogen system types shows that gaseous pathways generally achieve the highest efficiencies (28 %–39 %) and the lowest leakage rates (∼4.5 %) across the supply chain. Liquid hydrogen systems, while favorable for long-distance and high-volume transport due to their higher energy density, exhibit lower efficiency (∼28 %) and a greater leakage potential (∼12 %). Mixed systems, which combine gaseous and liquid elements (e.g., pipeline transmission followed by liquefaction and truck distribution), show compounded energy losses and moderate-to-high leakage rates (6.8 %–9.4 %), highlighting trade-offs associated with added system complexity. The study highlights opportunities for technological advancements, including optimizing liquefaction, enhancing insulation for storage and transportation, and refining refueling equipment. These improvements are crucial for maximizing the climate benefits of hydrogen. The results offer actionable insights for researchers, industry, and policymakers working to develop low-leakage, high-efficiency hydrogen infrastructure.

08 HYDROGEN↗

Effect of coaxial nozzle wear on catchment efficiency in direct energy deposition built components

Laser based Direct Energy Deposition (DED) systems using metallic powder feedstock are recognized as a promising manufacturing method for their ability to shorten production cycles and create complex part geometries. Components are built by generating a melt pool with a high-power laser beam while material is coaxially injected and left to solidify. An impediment to large scale use of DED lies in poor powder catchment efficiency, the condition in which a portion of injected powder escapes the melt pool resulting in a ratio of decreased printed material mass to mass of supplied feedstock. The wear state of a coaxial nozzle on a DED system within a hybrid manufacturing machine tool has been observed to decrease catchment efficiency over time. Herein this study investigates this effect by adapting flow visualization techniques to an in-situ process monitoring format, the implementation of a Computational Fluid Dynamics (CFD) simulation, and deposition testing. Nozzle geometric defects due to wear are identified and categorized, and the impact of nozzle tip wear, resulting in axial tip reduction, on powder catchment efficiency is proven by multiple calculation methods. A linear correlation between catchment efficiency and powder stream diameter is identified, causing a 15–20% loss in efficiency sustained over incremental nozzle tip reduction up to − 1 mm. These results provide a foundation for further study of wear effects and Zero defect manufacturing solutions for powder fed DED systems.

42 ENGINEERING↗

A carbon-efficient bicarbonate electrolyzer

Carbon efficiency is one of the most pressing problems of carbon dioxide electroreduction today. While there have been studies on anion exchange membrane electrolyzers with carbon dioxide (gas) and bipolar membrane electrolyzers with bicarbonate (aqueous) feedstocks, both suffer from low carbon efficiency. In anion exchange membrane electrolyzers, this is due to carbonate anion crossover, whereas in bipolar membrane electrolyzers, the exsolution of carbon dioxide (gas) from the bicarbonate solution is the culprit. Here, we first elucidate the root cause of the low carbon efficiency of liquid bicarbonate electrolyzers with thermodynamic calculations and then achieve carbon-efficient carbon dioxide electroreduction by adopting a near-neutral-pH cation exchange membrane, a glass fiber intermediate layer, and carbon dioxide (gas) partial pressure management. We convert highly concentrated bicarbonate solution to solid formate fuel with a yield (carbon efficiency) of greater than 96%. A device test is demonstrated at 100 mA cm -2 with a full-cell voltage of 3.1 V for over 200 h.

42 ENGINEERING↗