Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EAR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

341 records · Page 19

xEMU Suit Integrated Audio Communications System: Ambient and EVA Pressure Testing System Performance

Testing across several airlock and EVA thermal and pressure scenarios has demonstrated that the Integrated Audio System of NASA’s Exploration Extravehicular Mobility Unit (xEMU) spacesuits transmits and receives intelligible audio communications without the use of a commcap or similar worn device. The xEMU audio system consists of internal loudspeakers and digital microphones (Integrated Communications System –ICS) combined with an adaptive Acoustic Echo Canceller (AEC), outbound voice operated transmission (VOX), and automatic gain control (AGC). Transducers are mounted in an “exploded commcap” configuration with helmet-attached speakers near the ears and three microphones positioned at the collar. The AGC removes inbound audio signals (e.g.,suit, Mission Control, Lander, C&W tones) from the outbound comms stream, reducing echo and feedback (squeal) in low-noise suit environments. The reduction of worn communication equipment increases crewmember comfort, range of movement, and situational awareness. However, test results also highlight the need for proper fan, duct, pump, and gas flow integration with suit acoustics and audio. Ductwork may serve as waveguides for various component and structure-borne noise. Sharply angled ducts can generate turbulent-flow noise. Gas flow from inlets above the crewmember’s head can generate noise when cascading over the faceplate and collar (or commcap) microphones. Sufficient acoustic noise levels (1) require increased gain to boost inbound audio, and (2) may distort signals resulting in AEC disruption or artifacts. Suit-noise levels decline with reduced pressure (density), but then elevated speech and audio effort/power become necessary. Whether the Integrated Audio System, commcap, or other device is used, suit acoustic noise can mask speech in outbound comms. This reduces intelligibility and requires other AECs/devices to suppress comms noise. Yet, adjusting a few components may yield significant improvement. We discuss xEMU audio functionality, demonstrate how acoustical treatment combined with inbound signal conditioning improved clarity during tests, and discuss future modifications.

xEMU↗

Bone Conduction Headphone Research and Testing for xEMU Communications Applications

The new space suit being developed for exploration EVAs on the surface of the Moon and in microgravity environments is referred to as xEMU. A government reference model had been developed and has undergone extensive functional and environmental testing. This suit contains new upgrades from the current EMU on ISS, such as integrated speakers and microphones, eliminating the need for astronauts to wear a Communications Carrier Assembly (CCA) on their heads during spacewalks. However, this design approach results in speaker-to-microphone acoustic coupling and communications echo and feedback. A proposed solution to this issue is to replace the integrated open speakers with an astronaut worn bone conduction headset for audio capabilities while on EVA to receive incoming voice communications from Mission Control and other EVA or IVA crew members. This would eliminate the acoustic coupling and echo effect while being more ergonomically sound than the current CCA and leave the ear open to suit-ambient sound for situational awareness. A human-in-the-loop evaluation was performed, comparing five commercially available bone conduction headsets, to evaluate comfort, fit, and adjustability for long-duration wear. Five engineering test subjects with different head sizes were utilized to wear the headsets for six hours and provide succinct feedback and score the headsets on a variety of factors, to help determine which of the headsets performed the best and could advance to future bone conduction audio testing. Three of the headsets were well-received among the diverse group of subjects, and at least one of these will advance to further testing to be considered for future use under the xEMU helmet for exploration EVAs. Rating results and evaluation methods for this bone conduction headset evaluation will be presented.

Bridget Cavanaugh↗

xEMU Suit Integrated Audio Communications System: Ambient and EVA Pressure Testing System Performance

Testing across several airlock and EVA thermal and pressure scenarios has demonstrated that the Integrated Audio System of NASA’s Exploration Extravehicular Mobility Unit (xEMU) spacesuits transmits and receives intelligible audio communications without the use of a commcap or similar worn device. The xEMU audio system consists of internal loudspeakers and digital microphones (Integrated Communications System –ICS) combined with an adaptive Acoustic Echo Canceller (AEC), outbound voice operated transmission (VOX), and automatic gain control (AGC). Transducers are mounted in an “exploded commcap” configuration with helmet-attached speakers near the ears and three microphones positioned at the collar. The AGC removes inbound audio signals (e.g.,suit, Mission Control, Lander, C&W tones) from the outbound comms stream, reducing echo and feedback (squeal) in low-noise suit environments. The reduction of worn communication equipment increases crewmember comfort, range of movement, and situational awareness. However, test results also highlight the need for proper fan, duct, pump, and gas flow integration with suit acoustics and audio. Ductwork may serve as waveguides for various component and structure-borne noise. Sharply angled ducts can generate turbulent-flow noise. Gas flow from inlets above the crewmember’s head can generate noise when cascading over the faceplate and collar (or commcap) microphones. Sufficient acoustic noise levels (1) require increased gain to boost inbound audio, and (2) may distort signals resulting in AEC disruption or artifacts. Suit-noise levels decline with reduced pressure (density), but then elevated speech and audio effort/power become necessary. Whether the Integrated Audio System, commcap, or other device is used, suit acoustic noise can mask speech in outbound comms. This reduces intelligibility and requires other AECs/devices to suppress comms noise. Yet, adjusting a few components may yield significant improvement. We discuss xEMU audio functionality, demonstrate how acoustical treatment combined with inbound signal conditioning improved clarity during tests, and discuss future modifications.

xEMU↗

Infrascope: Full-Spectrum Phonocardiography With Automated Signal Analysis Report

Physicians have used the stethoscope to listen to heart sounds for over 150 years. During this time the stethoscope has remained nearly unchanged. While the device is inexpensive, simple and easy to use, it has shortcomings as a diagnostic tool. It is dependent on human hearing to detect the complex sounds made by the heart, and human memory to analyze them. There also has been a significant decline in the use of stethoscope, at least in part because of the availability of technologies such as the echocardiogram, which can provide imaging and blood flow through the heart chambers. However, echocardiography can be complex, costly and time consuming and requires the need for a specialist, all of which delay the diagnosis and increase the cost of patient evaluation. Even with the availability of echocardiogram devices such as the handheld pocket ultrasound, diagnosing heart problems can still be difficult. The Infrascope is a new device that resembles a traditional stethoscope and is simple to use. In addition, the Infrascope offers greater sensitivity and a wider range of frequencies heard by the human ear, <20Hz than a traditional stethoscope can detect. Through automated analysis of the full spectrum of heart sounds, it has the potential to improve diagnostic accuracy while reducing the need for referrals, allowing primary care physicians to practice better medicine at the bedside.

Infrasounds↗

The NASA earth resources spectral information system: A data compilation

The NASA Earth Resources Spectral Information System and the information contained therein are described. It contains an ordered, indexed compilation of natural targets in the optical region from 0.3 to 45.0 microns. The data compilation includes approximately 100 rock and mineral, 2600 vegetation, 1000 soil, and 60 water spectral reflectance, transmittance, and emittance curves. Most of the data have been categorized by subject, and the curves in those subject areas have been plotted on a single graph. Those categories with too few curves and miscellaneous categories have been plotted as single-curve graphs. Each graph, composite of single, is fully titled to indicate curve source and is indexed by subject to facilitate user retrieval.

Leeman, V.↗

Surgical evaluation of candidates for cochlear implants

The customary presentation of surgical procedures to patients in the United States consists of discussions on alternative treatment methods, risks of the procedure(s) under consideration, and potential benefits for the patient. Because the contents of the normal speech signal have not been defined in a way that permits a surgeon systematically to provide alternative auditory signals to a deaf patient, the burden is placed on the surgeon to make an arbitrary selection of candidates and available devices for cochlear prosthetic implantation. In an attempt to obtain some information regarding the ability of a deaf patient to use electrical signals to detect and understand speech, the Good Samaritan Hospital and Neurological Sciences Institute cochlear implant team has routinely performed tympanotomies using local anesthesia and has positioned temporary electrodes onto the round windows of implant candidates. The purpose of this paper is to review our experience with this procedure and to provide some observations that may be useful in a comprehensive preoperative evaluation for totally deaf patients who are being considered for cochlear implantation.

Non-NASA Center↗

Two-dimensional spatiotemporal coding of linear acceleration in vestibular nuclei neurons

Response properties of vertical (VC) and horizontal (HC) canal/otolith-convergent vestibular nuclei neurons were studied in decerebrate rats during stimulation with sinusoidal linear accelerations (0.2-1.4 Hz) along different directions in the head horizontal plane. A novel characteristic of the majority of tested neurons was the nonzero response often elicited during stimulation along the "null" direction (i.e., the direction perpendicular to the maximum sensitivity vector, Smax). The tuning ratio (Smin gain/Smax gain), a measure of the two-dimensional spatial sensitivity, depended on stimulus frequency. For most vestibular nuclei neurons, the tuning ratio was small at the lowest stimulus frequencies and progressively increased with frequency. Specifically, HC neurons were characterized by a flat Smax gain and an approximately 10-fold increase of Smin gain per frequency decade. Thus, these neurons encode linear acceleration when stimulated along their maximum sensitivity direction, and the rate of change of linear acceleration (jerk) when stimulated along their minimum sensitivity direction. While the Smax vectors were distributed throughout the horizontal plane, the Smin vectors were concentrated mainly ipsilaterally with respect to head acceleration and clustered around the naso-occipital head axis. The properties of VC neurons were distinctly different from those of HC cells. The majority of VC cells showed decreasing Smax gains and small, relatively flat, Smin gains as a function of frequency. The Smax vectors were distributed ipsilaterally relative to the induced (apparent) head tilt. In type I anterior or posterior VC neurons, Smax vectors were clustered around the projection of the respective ipsilateral canal plane onto the horizontal head plane. These distinct spatial and temporal properties of HC and VC neurons during linear acceleration are compatible with the spatiotemporal organization of the horizontal and the vertical/torsional ocular responses, respectively, elicited in the rat during linear translation in the horizontal head plane. In addition, the data suggest a spatially and temporally specific and selective otolith/canal convergence. We propose that the central otolith system is organized in canal coordinates such that there is a close alignment between the plane of angular acceleration (canal) sensitivity and the plane of linear acceleration (otolith) sensitivity in otolith/canal-convergent vestibular nuclei neurons.

NASA Discipline Neuroscience↗

A Tree-Ring Chronology and Paleoclimate Record for the Younger Dryas-Early Holocene Transition from Northeastern North America

Spruce and tamarack logs dating from the Younger Dryas and Early Holocene (YDEH; approx. 12.9 - 11.3k cal a BP) were found at Bell Creek in the Lake Ontario lowlands of the Great Lakes region, North America. A 211-year tree-ring chronology dates to approx. 11 755 -11 545 cal a BP, across the YDEH transition. A 23-year period of higher year-to-year ring-width variability dates to around 11 650 cal a BP, infers strong regional climatic perturbations and may represent the end of the YD. Tamarack and spruce were dominant species throughout the YD - EH interval at the site, indicating that boreal conditions persisted into the EH, in contrast to geographical regions immediately south and east of the lowlands, but consistent with the Great Lakes interior lowlands. This infers that Bell Creek was at the eastern boundary of a boreal ecotone, perhaps a result of its lower elevation and the non-analog dynamics of the Laurentide Ice Sheet. This finding suggests that the ecotone boundary extended farther east during the YD - EH transition than previously thought.

dendroclimatology;northeastern North America;spruc↗