JSC Materials Laboratory Reproduction and Failure Analysis of Cracked Orbiter Reaction Control System Niobium Thruster Injectors
In April 2004 a Space Shuttle Orbiter Reaction Control System (RCS) thruster was found to be cracked while undergoing a nozzle (niobium/C103 alloy) retrofit. As a failure resulting from an in-flight RCS thruster burn-through (initiated from a crack) could be catastrophic, an official Space Shuttle Program flight constraint was issued until flight safety could be adequately demonstrated. This paper describes the laboratory test program which was undertaken to reproduce the cracking in order to fully understand and bound the driving environments. The associated rationale developed to justify continued safe flight of the Orbiter RCS system is also described. The laboratory testing successfully reproduced the niobium cracking, and established specific bounding conditions necessary to cause cracking in the C103 thruster injectors. Each of the following conditions is necessary in combination together: 1) a mechanically disturbed / cold-worked free surface, 2) an externally applied sustained tensile stress near yield strength, 3) presence of fluorine-containing fluids on exposed tensile / cold-worked free surfaces, and 4) sustained exposure to temperatures greater than 400 F. As a result of this work, it was concluded that fluorine-containing materials (e.g. HF acid, Krytox , Brayco etc.) should be carefully controlled or altogether eliminated during processing of niobium and its alloys.