Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dispatchable Solar Power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Absorbing the Sun: Operational Practices and Balancing Reserves in Florida's Municipal Utilities

The Florida Reliability Coordinating Council (FRCC) power system is comprised of multiple balancing authorities ranging in size from Gainesville Regional Utilities (GRU) with a 2019 summer net firm demand of 429 MW to Florida Power & Light with a 2019 summer net firm demand of 22,510 MW; and including cooperative, municipal, and investor-owned utilities. As all of these balancing authorities are and have plants to continue installing significant quantities of utility-scale solar photovoltaics, one relevant question is how much operating reserves they will need to hold as solar penetrations increase. While there are estimates of how regulating and flexibility reserve requirements change with solar penetration, the literature almost exclusively focuses on large balancing authorities with sub-hourly dispatch. In this work we analyze how reserve needs change not only with solar photovoltaic penetration, but also balancing authority size and operational practices. We find that, measured as a fraction of load, smaller balancing authorities with less frequent load and solar forecasts and less frequent dispatch need more reserves. Such utilities' reserve needs also increase more with increasing solar deployment as compared to larger or more frequently dispatched balancing authorities. These impacts are most acute for GRU. We find that moving from day-ahead to hour-ahead load and solar forecasting and system dispatch could enable GRU to incorporate 32% solar generation with median reserves at 20% instead of 60% of load; and that median reserve needs could drop further to about 10% of load if Florida's municipal utilities formed a reserve sharing group and moved to sub-hourly dispatch.

14 SOLAR ENERGY↗

IDAES Enterprise: Generation Expansion Planning with Enhanced Requirements for Capacity Adequacy Under Renewable Intermittency

Achieving net zero carbon emissions likely requires future power systems to integrate new, flexible energy technologies to accommodate higher levels of capacity from variable renewable energy sources. To determine the optimal deployment of new electricity capacity and to study the likelihood of deployments of new energy technologies, an expansion planning model has been developed as part of the IDAES-Enterprise suite of grid models. The Generation Expansion Planning (GEP) model is a multi-period model in which investment decisions occur yearly, and a Unit Commitment (UC) problem is examined on an hourly timescale. To reduce computational complexity of the GEP model, the UC problem is solved for average “representative days” which leaves out extreme, but relatively common, scenarios in which low renewable generation occurs, leaving the system with inadequacy in capacity. The IDAES-Enterprise GEP model has been modified to include these extreme scenarios while keeping the model reasonably tractable. Specifically, a lazy constraint technique was implemented to check for capacity adequacy on an hourly basis over a large data set of aligned load-wind-solar profiles. As a vast majority of the capacity constraints will not be violated, the technique lowers computational expense by searching for violated capacity constraints over an “iterative manner,” adding those infeasible constraints back into the model. Results on a test case of the Southwest Power Pool shows that the lazy constraint technique significantly reduces retirements and increases installments of natural gas combined cycles and flexible natural gas units. It also reduces some retirements of coal units. These modifications provide a more reasonable estimation of required dispatchable power generation capacity to ensure feasibility during peak net load.

Liu, Peng↗

A Technical and Economic Assessment of LWR Flexible Operation for Generation and Demand Balancing to Optimize Plant Revenue

With increased penetration of subsidized variable renewable energy (VRE) resources and competition from low natural gas prices, existing light water reactor (LWR) nuclear power plants (NPPs) are struggling to remain economically competitive. This work examines the potential economic competitiveness of various thermal energy storage (TES) technologies when coupled directly or indirectly with a NPP. To highlight their relative economic competitiveness, we contrast several energy storage solutions in stochastic dispatch optimization. We leverage data from recent work analyzing a range of TES technologies with varying capital costs, performance, and technology readiness level (TRL) to establish our case. We explore inserting these technologies into an electricity market with existing nuclear generation and large projected variable renewable energy (VRE) penetration. Although these technologies' projected capital costs may make them unlikely candidates in their current state, this analysis demonstrates a high-fidelity techno-economic analysis of energy storage. Furthermore, as the projected cost of energy storage technologies evolves, this analysis sets a precedent for similar future investigations. One region with projected trends that may be unfavorable for existing nuclear capacity is the New York Independent System Operator (NYISO) market. New York state’s baseload generation has been historically provided by fossil-fired and nuclear assets. However, amid economic pressures from subsidized VREs and low natural gas prices, the state has recently deactivated Indian Point nuclear power plant units 2 and 3. Furthermore, the state plans to meet its zero-emission generation target by 2040 by replacing fossil-fired capacity with significant investments in VRE resources like wind and solar photovoltaic (PV) and battery storage. Increased intermittent resource penetration lowers the baseload power requirement, adding further economic pressure to the state’s three remaining NPPs still in operation. With three NPPs still in operation in New York, this work analyzes potential economic benefits to NPPs on the New York grid when directly or indirectly coupled with various TES technologies. This work requires two modeling steps to analyze the potential economic benefits of various system configurations of the TES directly or indirectly coupled with nuclear. First, this analysis leverages capacity expansion modeling by experts at the Electric Power Research Institute (EPRI). Using their deterministic capacity expansion model, U.S. Regional Economy, Greenhouse Gas, and Energy (US-REGEN), EPRI analysts evaluated the capacity and generation evolution of the New York state energy market under four projection scenarios. These four projection scenarios were developed to represent the potential evolution of the capacity and generation in NYISO from 2015 to 2050 under various economic, technology, and policy constraints. The results from these capacity expansion models are then used as boundary conditions in the second modeling step. The second modeling step uses the Holistic Energy Resource Optimization Network (HERON) for a set of stochastic techno-economic analyses (STEAs) to investigate the potential increase in the economic viability of various configurations of the TES. With no current capacity expansion capabilities, HERON takes the data generated from US-REGEN for 2050 to generate synthetic load, solar, and wind data. Then HERON economically optimizes the capacity and dispatch of the various TES configurations. The potential economic benefit is the differential net present value (NPV) of the TES configurations from the no-TES baseline. As a stochastic techno-economic analysis package, HERON introduces uncertainty into the economic metrics, while US-REGEN trades resolution for reduced computational complexity. Using HERON also allows the modeling of direct thermal coupling, a feature not common in capacity and dispatch models. As expected, with high capital costs, the costs of introducing energy storage for all the technologies considered outweighed the potential economic benefit of this strategy for flexible plant operation. The benefit of this analysis is primarily in demonstrating a workflow that examines innovative solutions to increase NPP revenue via TES coupling. HERON’s stochastic capacity and dispatch optimization process used in this work has proven an effective tool in observing and evaluating the impact of introducing storage technologies in a grid energy system.

25 ENERGY STORAGE↗

Evaluating grid stress and reliability in future electricity grids across a range of demand, generation mix, and weather trends

The reliability of power grids in the future will depend on how system planners account for the integration of new technologies, extreme weather events, and uncertainties in demand growth from increased electrification and data centers. This study introduces an open-source, multisectoral, multiscale modeling framework that projects grid stress and reliability trends between 2020 and 2055 in the Western Interconnection of the United States. The framework integrates global to national energy-water-land dynamics with power plant siting and hourly grid operations modeling. We analyze future wholesale electricity price shocks and unserved energy events across eight scenarios spanning a range of population growth and economic change, generation mixes, and weather conditions. Our results show future grids with high percentage of non-renewable generation and strong economic growth are characterized by higher reliability and lower wholesale electricity prices than lower growth scenarios because of larger reliance on dispatchable generators and lower fossil fuel extraction costs. Scenarios with high percentage of renewable resources have lower median but more volatile wholesale electricity prices as well as more frequent and severe unserved energy events compared to scenarios relying more on dispatchable generators. These events occur because higher proportion of solar and wind energy causes net demand curves to deepen during midday (duck curves get progressively severe), exacerbating the challenge of meeting demand during summer evening peaks. This study suggests that robust and co-optimized transmission and energy storage planning could help maintain low wholesale electricity prices and high reliability levels in future electricity grids across uncertainties in generation mixes.

Electric grid reliability↗

Qualification testing and electrical measurement experience: A manufacturer's view

ARCO Solar's experiences as a participant in an industry-utility-government environmental qualification team examining photovoltaic devices are discussed. Included is an assessment of the applicability, completeness and appropriateness of the testing procedures and of the acceptance criteria for megawatt-sized procurements for utilities. Like the stand-alone users, the utility industry is interested in obtaining low costs, but additional concerns exist related to reliability and durability, safety, grounding and overall system criteria including performance prediction (related to output power acceptance testing), power quality and dispatchability. For purposes of this first major purchase of photovoltaic modules and panels by the utility industry, there was a carry-over of the JPL specifications. The need exists for futher development, assessement, and selection of qualification and testing standards and evaluation criteria specifically addressing these additional concerns for utility-connected PV power-plant applications.

Arnett, J. C.↗

Opportunities and Challenges for Nuclear-Renewable Hybrid Energy Systems

TTightly coupled nuclear-renewable hybrid energy systems (N-R HESs) are systems that link subsystems to generate dispatchable electricity and produce at least one industrial product from two or more energy resources. Because N-R HESs are designed to produce different products based on the value of those products in markets, their optimal designs and operations can be complex. This paper summarizes some key conclusions from a set of economic analyses of N-R HESs. Each N-R HES use case analyzed includes a nuclear reactor, a thermal power cycle to convert nuclear energy into electricity, either a wind or photovoltaic solar subsystem producing electricity, and an industrial process producing an energy or an industrial product. The analyses focused on identifying the optimal configuration and hours of operations for each N-R HES within ranges of hypothetical future electricity price profiles and industrial product prices. Four important insights are drawn from the results of those analyses.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Opportunities and Challenges for Nuclear-Renewable Hybrid Energy Systems

Tightly coupled nuclear-renewable hybrid energy systems (N-R HESs) are systems that link subsystems to generate dispatchable electricity and produce at least one industrial product from two or more energy resources. Because N-R HESs are designed to produce different products based on the value of those products in markets, their optimal designs and operations can be complex. This paper summarizes some key conclusions from a set of economic analyses of N-R HESs. Each N-R HES use case analyzed includes a nuclear reactor, a thermal power cycle to convert nuclear energy into electricity, either a wind or photovoltaic solar subsystem producing electricity, and an industrial process producing an energy or an industrial product. The analyses focused on identifying the optimal configuration and hours of operations for each N-R HES within ranges of hypothetical future electricity price profiles and industrial product prices. Four important insights are drawn from the results of those analyses.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Network Constraints Consideration for Grid-Edge Energy Management System

Increased deployment of distributed energy resources (DER) in distribution system is bringing need for enhanced grid intelligence, control, and flexibility. This is significant at the edge of the grid where DERs, loads or microgrids are located. Integrated DERs in a distribution system need to follow grid codes to avoid violations that results in DER disconnection. To comply with grid code requirements (e.g. IEEE 1547-2018) at the grid edge level, network constrained grid edge energy management system (GEEMS) is proposed in this paper. The objective of GEEMS is to provide economic solution for active and reactive power dispatch set-points at each interval and ensure voltage regulation to support secure interconnection of the grid edge segment to the distribution system. To evaluate the proposed GEEMS framework, four DERs are included into IEEE 13 bus system. GEEMS outperforms the existing economic dispatch-based energy management system by reducing the voltage violation.

Electric vehicle depot charging station↗

Electric Vehicle Managed Charging: Forward-Looking Estimates of Bulk Power System Value

When and where electric vehicle charging occurs has significant implications for power systems supporting widespread electric vehicle deployment with high shares of wind and solar generation. Numerous studies have estimated the value of scheduling or otherwise managing electric vehicle charging in such power systems. This study improves on those earlier works by leveraging detailed simulation models for electric vehicle adoption, electric vehicle use, electric vehicle charging, and bulk power system operations; and linking them with methods for describing charging flexibility at both the individual vehicle and aggregate levels. This study closely analyzes electric vehicle managed charging (EVMC) performance along the dimensions of flexibility type (within-charging session or within-week scheduling), dispatch mechanism (direct load control or one of several price-based mechanisms), and participation rate, under the assumptions of ubiquitous chargers and all trips completed on time. The study is located in a passenger light-duty vehicle adoption scenario with 100% electric vehicle sales by 2035, and in an envisioned 2038 New England power system for which within-region generation is 84% clean.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analysis of the Effects of a Flexible Ramping Ancillary Service Product on Power System Operations: Preprint

The recent increased interest in utilizing variable generation (VG) resources such as wind and solar in power systems has motivated investigations into new operating procedures. Although these resources provide desirable value to a system (e.g., no fuel costs or emissions), interconnecting them provides unique challenges. Their variable, non-controllable nature in particular requires significant attention, because it directly results in increased power system variability and uncertainty. One way to handle this is via new operating reserve schemes. Operating reserves provide upward and downward generation and ramping capacity to counteract uncertainty and variability prior to their realization. For instance, uncertainty and variability in real-time dispatch can be accounted for in the hour-ahead unit commitment. New operating reserve methodologies that specifically account for the increased variability and uncertainty caused by VG are currently being investigated and developed by academia and industry. This paper examines one method inspired by the new operating reserve product being proposed by the California Independent System Operator. The method is based on examining the potential ramping requirements at any given time and enforcing those requirements via a reserve demand curve in the market-clearing optimization as an additional ancillary service product.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Evaluation of Multi-Vendor Grid-Forming Inverters for Grid-Connected Operation Through Hardware Experimentation: Preprint

Existing real-world projects of GFM inverters that operate in parallel to power grids typically are sized between dozens and a few hundreds Megawatt (MW) scale according to a recent NERC GFM inverter white paper. These large systems are often difficult to evaluate prior to deployments because of their large size. The performance of smaller GFM inverters (dozens to a few hundreds MW) that operate parallel with power grids (distribution systems) is even less understood. There is an opportunity to better understand these systems through hardware testing under controlled laboratory conditions. Therefore, this paper presents the functional performance evaluation tests of multiple (three) commercial GFM inverters when they operate in parallel with the grid through hardware experiments. The goal of these tests is to explore the GFM inverters' functionalities and dynamic response when in parallel with power grids to eventually develop universal specifications for GFM inverters. Both steady state (changing the inverter's frequency and voltage droop) and transient (adding step change in grid's frequency/voltage) tests are performed for each GFM inverter with the same testing circuit and testing protocol. The experimental results indicate the bench-marked performance that: 1) the GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power when paralleled to the grid; 2) the GFM inverters automatically respond to system frequency and voltage events to output the needed power, however, the GFM inverters all show stability issues when absorbing reactive power from the grid.

grid-forming inverters↗

Optimal Dispatch for the US Virgin Islands to Increase Renewable Rates in Saint Croix

The US Virgin Islands, like many other small island nations, face significant challenges related to its energy supply. Their dependency on imported fossil fuels not only drives up energy costs, but also contributes to different environmental problems. Nevertheless, their generally sunny and windy climate makes this archipelago an ideal location for renewable energy development. Increasing the use of sources such as wind, and solar can help reduce their energy dependency, lower their levelized cost of electricity, and improve the health and wellbeing of local communities. In this paper, an optimal dispatcher is employed to analyze the implications on energy security of employing different technology options according to the plans of the local system operator. In this context, short term stability is ensured by inserting operational constraints in the energy management system based on stability analysis developed in PSCAD. The results highlight the usefulness of integrating PV and battery system, while further analysis are required to justify integrating wind power.

energy islands↗

Contributions of Solar + Storage to Future Power Needs

The costs of solar photovoltaics (PV) have been dropping in recent years, leading to increasing installations of solar PV systems and growing interest in how the technology will impact the electric grid. Additionally, as battery costs decline, there is increasing interest in understanding the benefits and limitations of battery storage for the grid as well as potential co-benefits of coupling battery storage and photovoltaics. This paper presents recent methodological developments to more accurately represent the value and limitations of coupled PV and battery systems in capacity expansion models. These are demonstrated using the Resource Planning Model (RPM), which co-optimizes capacity investments, transmission investments, and reduced-order dispatch through 2045. We simulate the evolution of the generation and transmission system in the Western Interconnection both with and without a coupled PV and battery technology option under two core scenarios - a baseline scenario and a high renewable penetration scenario - coupled with sensitivities assuming low and mid PV and battery cost projections. We analyze the degree to which a variety of configurations of coupled PV + Battery systems are able to meet future electricity needs, under which system conditions this coupled technology becomes beneficial to the electric grid and identify the displaced technologies when coupled solar and storage is introduced into the model. We find that capturing the benefits of co-locating these systems becomes increasingly important as the penetration of solar PV rises, and that in particular it is important to accurately capture the ability of these technologies to shift energy, provide firm capacity, and reduce expected curtailment.

14 SOLAR ENERGY↗

The Wide-area Energy Management System Phase 2 Final Report

The higher penetration of intermittent generation resources (including wind and solar generation) in the Bonneville Power Administration (BPA) and California Independent System Operator (CAISO) balancing authorities (BAs) raises issue of requiring expensive additional fast grid balancing services in response to additional intermittency and fast up and down power ramps in the electric supply system. The overall goal of the wide-area energy management system (WAEMS) project is to develop the principles, algorithms, market integration rules, a functional design, and a technical specification for an energy storage system to help cope with unexpected rapid changes in renewable generation power output. The resulting system will store excess energy, control dispatchable load and distributed generation, and utilize inter-area exchange of the excess energy between the California ISO and Bonneville Power Administration control areas. A further goal is to provide a cost-benefit analysis and develop a business model for an investment-based practical deployment of such a system. There are two tasks in Phase 2 of the WAEMS project: the flywheel field tests and the battery evaluation. Two final reports, the Wide-area Energy Management System Phase 2 Flywheel Field Tests Final Report and the Wide-area Energy Storage and Management System Battery Storage Evaluation, were written to summarize the results of the two tasks.

25 ENERGY STORAGE↗

The Potential Impact of Offshore Wind Energy on a Future Power System in the U.S. Northeast

This study aims to understand and quantify the potential impact of offshore wind on a future electricity system in the U.S. Northeast. In this analysis, a detailed representation of the Northeast power system is adopted, using a generation portfolio for 2024 paired with offshore wind nameplate capacities of 0 gigawatts (GW), 2 GW, and 7 GW. The analysis identifies points of offshore wind interconnection in the ISO-New England and New York Independent System Operator control areas and uses hourly wind profiles from the Wind Integration National Dataset Toolkit. Hourly simulations of the 2024 power system operations show an ability to accommodate the prescribed offshore wind capacities by adapting the system's generation dispatch. Curtailment levels of offshore wind range between 4% and 5%. Offshore wind generation displaces primarily natural-gas combined-cycle generation; however, requires increased flexibility from combined cycles through more frequent start-ups. The number of hours with transmission congestion increases because of offshore wind injection, with varying impact on a subregional level. Offshore wind's capacity credit was found to be 14.5%-28.3% and is lower than estimated in other large-scale power system studies, in part because this study considered a different weather year and a power system representation with higher shares of solar PV and onshore wind. The reliability contribution of resources is a topic area identified for more research and collaboration. The 7-GW scenario shows a reduction in locational marginal price of 11%, with production cost savings of up to 18% compared to the 0-GW scenario.

17 WIND ENERGY↗

Feasibility Study of Large-Scale Energy Storage in the Earth

Energy storage systems on a large scale are needed when there is a mismatch between electricity generation and demand rates. The mismatch may be due to a variety of reasons: 1. Generation rates of solar are cyclic and are often out of phase with the demand cycles. 2. Generation rates of wind are unpredictable. Furthermore, high-efficiency, low-carbon power plants (e.g., nuclear) typically have high capital cost and low operating cost. Such plants are designed for continuous base-load operation and require a high capacity factor for economic viability (Forsberg, 2017). For these reasons, it is advantageous to be able to store energy when not needed and use it when needed. Our proposed process, called the Air Earth Battery, has been developed to accomplish the task of energy storage and dispatch, using a combination of compressors, expanders, heat exchangers, and subsurface porous, permeable rock formations. This technology utilizes two issued U.S. Patents (Buscheck, 2017a; 2017b), one filed U.S. Patent Application (Buscheck, 2017c), and one filed U.S. Provisional Patent Application (Buscheck and Upadhye, 2018).

25 ENERGY STORAGE↗

Optimizing DER Deployment for Climate, Health, Resilience, and Energy Bill Benefits Using the REopt Model

Climate change, public health, and resilience to power outages are of critical concern to local governments, federal agencies, and the private sector, and are increasingly motivating investments in distributed energy resources (DERs). However, designing a solar-plus-storage system to co-optimize for climate, health, resilience, and energy bill benefits requires complex trade-offs. To address this need, the National Renewable Energy Laboratory has integrated climate and health impacts of grid-purchased electricity and on-site fuel consumption into the publicly-available REopt web tool and API - a techno-economic model that determines the cost-optimal DER system sizes and dispatch strategy. This presentation will provide an overview of the tool's methodology, datasets, and capabilities, including costing emissions into system sizing and dispatch and setting emissions reductions targets. Results of previous work will demonstrate the use of new emissions accounting capabilities by quantifying the impact of including climate and health costs on the optimal resilient microgrid configurations for a hospital, school, and warehouse across 14 U.S. cities.

climate↗