Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diffraction systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

The Formation of Wassonite: A New Titanium Monosulfide Mineral in the Yamato 691 Enstatite Chondrite

Wassonite, ideally stoichiometric TiS, is a titanium monosulfide not previously observed in nature, that was discovered within the Yamato 691 EH3 enstatite chondrite [1]. Because of the submicrometer size of the wassonite grains, it was not possible to determine conventional macroscopic properties. However, the chemical composition and crystal structure were well constrained by extensive quantitative energy dispersive x-ray analysis and electron diffraction using transmission electron microscopy (TEM). The crystal system for wassonite is rhombohedral (a = 3.42 plus or minus 0.07, c = 26.50 plus or minus 0.53 Angstroms) with space group: R(sup 3 raised bar) m (R9 type), cell volume: 268.4 plus or minus 0.53 Angstroms(sup 3), Z=9, density (calculated): 4.452 grams per cubic centimeter, empirical formula: (Ti(sub 0.93), Fe(sub 0.06), Cr(sub 0.01))S. In this study, we discuss possible formation mechanisms of wassonite and its associated minerals based on the petrology, mineralogy, crystallography, thermodynamic calculations, Al/Mg isotopic systematics and the O-isotopic composition of the wassonite-bearing BO chondrule.

Nakamura-Messenger, K.↗

Aperture Mask for Unambiguous Parity Determination in Long Wavelength Imagers

A document discusses a new parity pupil mask design that allows users to unambiguously determine the image space coordinate system of all the James Webb Space Telescope (JWST) science instruments by using two out-of-focus images. This is an improvement over existing mask designs that could not completely eliminate the coordinate system parity ambiguity at a wavelength of 5.6 microns. To mitigate the problem of how the presence of diffraction artifacts can obscure the pupil mask detail, this innovation has been created with specifically designed edge features so that the image space coordinate system parity can be determined in the presence of diffraction, even at long wavelengths.

Bos, Brent↗

Long-Wave Infrared Dyson Spectrometer

Preliminary results are presented for an ultra compact long-wave infrared slit spectrometer based on the dyson concentric design. The dyson spectrometer has been integrated in a dewar environment with a quantum well infrared photodetecor (QWIP), concave electron beam fabricated diffraction grating and ultra precision slit. The entire system is cooled to cryogenic temperatures to maximize signal to noise ratio performance, hence eliminating thermal signal from transmissive elements and internal stray light. All of this is done while maintaining QWIP thermal control. A general description is given of the spectrometer, alignment technique and predicated performance. The spectrometer has been designed for optimal performance with respect to smile and keystone distortion. A spectral calibration is performed with NIST traceable targets. A 2-point non-uniformity correction is performed with a precision blackbody source to provide radiometric accuracy. Preliminary laboratory results show excellent agreement with modeled noise equivalent delta temperature and detector linearity over a broad temperature range.

imaging↗

Insights on the dissolution of water in an albite melt at high pressures and temperatures from a direct structural analysis

The water dissolution mechanism in silicate melts under high pressures is not well understood. Here we present the first direct structure investigation of a water-saturated albite melt to monitor the interactions between water and the network structure of silicate melt at the molecular level. In situ high-energy X-ray diffraction was carried out on the NaAlSi 3 O 8 -H 2 O system at 800 °C and 300 MPa, at the Advanced Photon Source synchrotron facility. The analysis of the X-ray diffraction data was augmented with classical Molecular Dynamics simulations of a hydrous albite melt, incorporating accurate water-based interactions. The results show that metal–oxygen bond breaking at the bridging sites occurs overwhelmingly at the Si site upon reaction with H 2 O, with subsequent Si–OH bond formation and negligible Al–OH formation. Furthermore, we see no evidence for the dissociation of the Al 3+ ion from the network structure upon breaking of the Si–O bond in the hydrous albite melt. The results also indicate that the Na + ion is an active participant in the modifications of the silicate network structure of the albite melt upon water dissolution at high P–T conditions. We do not find evidence for the Na + ion dissociating from the network structure upon depolymerization and subsequent formation of NaOH complexes. Instead, our results show that the Na + ion persists as a structure modifier with a shift away from Na–BO bonding to an increase in the extent of Na-NBO bonding, in parallel with pronounced depolymerization of the network. Our MD simulations show that the Si–O and Al–O bond lengths are expanded by about 6% in the hydrous albite melt compared to those of the dry melt at high P–T conditions. The changes in the network silicate structure of a hydrous albite melt at high pressure and temperature, as revealed in this study, must be considered in the advancement of water dissolution models of hydrous granitic (or alkali aluminosilicate) melts.

36 MATERIALS SCIENCE↗

Optical Design of $\mathrm{DEI/ABI}$ System at the $\mathrm{HEX}$ Beamline at the $\mathrm{NSLS-II}$

Diffraction Enhanced Imaging (DEI) or Analyzer Based Imaging (ABI) uses a perfect crystal monochromator and matching analyzer to achieve sensitivity to x-ray refraction and ultra small-angle scattering on the order of 0.01 micro-radians. As such, a thermal bump caused by heat-load in the order of 1 W is detrimental. The heat load at the HEX (High Energy Engineering X-ray) super-conducting wiggler (SCW) beamline, under construction at the NSLS-II, is on the order of 1 kW. How to reconcile the three orders of magnitude difference between the HEX source power and the DEI/ABI requirements? The solution involves using a double-crystal bent-Laue monochromator as pre-monochromator to prepare a beam with a large divergence and bandwidth that is matched to a flat crystal post-monochromator. We show through phase-space (x-ray energy vs. angle as viewed by a flat crystal) analysis and Dumond diagrams that there is indeed a unique bending radius that matches the double-crystal bent-Laue monochromator in phase space to the flat Bragg crystal. The matched system has a desirable feature that the phase space of the bent crystal’s output beam is much larger than that of the flat crystal, making the combined system stable. Based on these considerations, here we present our optical design for performing DEI/ABI at the HEX beamline

36 MATERIALS SCIENCE↗

Adventures in Classical PSF Subtraction

Circumstellar Disks, exoplanets, stellar companions are often inconveniently close to a bright object (host star). Exposing sufficiently deeply to detect the object of interest can mean that you overexpose the instrument you are using and swamp the signal of interest. This talk will focus on using a simple coronagraph, and how best to separate the signal of interest from light from the star Optical systems, and HST is no exception, typically spread the light from an unresolved source due to diffraction, scattering in the telescope, and in the science instrument, and in some cases within the detector system. This is termed the point spread function (PSF). For the majority of circumstellar disks and exoplanets signal in the wings of the PSF signal of interest. Simplest of the techniques that will be covered in this hands-on demonstrationUse a suitably chosen other observation as an estimate of the light from the star that you want to get rid of. Need to match the science observation in terms of factors affecting the shape of the PSF, and those affecting temporal variation in the measured PSF.

coronagraph↗

Ultrafast light-induced shear strain probed by time-resolved x-ray diffraction: Multiferroic BiFeO 3 as a case study

Enabling the light control of complex systems on ultrashort timescales gives rise to rich physics with promising applications. Although crucial, the quantitative determination of both the longitudinal and the shear photoinduced strains still remains challenging. Here, by scrutinizing asymmetric Bragg peaks pairs (±h01) in BiFeO 3 using picosecond time-resolved x-ray diffraction experiments, we simultaneously determine the longitudinal and shear strains. Importantly, we reveal a difference in the dynamical response of the longitudinal strain with respect to the shear one due to an interplay of quasilongitudinal and quasitransverse acoustic modes, well reproduced by our model. Lastly, we show that the relative amplitude of those strains can be explained only if both thermal and nonthermal processes contribute to the acoustic phonon photogeneration process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A spatial beam property analyzer based on dispersive crystal diffraction for low-emittance X-ray light sources

Abstract The advent of low-emittance synchrotron X-ray sources and free-electron lasers urges the development of novel diagnostic techniques for measuring and monitoring the spatial source properties, especially the source sizes. This work introduces an X-ray beam property analyzer based on a multi-crystal diffraction geometry, including a crystal-based monochromator and a Laue crystal in a dispersive setting to the monochromator. By measuring the flat beam and the transmitted beam profiles, the system can provide a simultaneous high-sensitivity characterization of the source size, divergence, position, and angle in the diffraction plane of the multi-crystal system. Detailed theoretical modeling predicts the system’s feasibility as a versatile characterization tool for monitoring the X-ray source and beam properties. The experimental validation was conducted at a bending magnet beamline at the Swiss Light Source by varying the machine parameters. A measurement sensitivity of less than 10% of a source size of around 12 µm is demonstrated. The proposed system offers a compact setup with simple X-ray optics and can also be utilized for monitoring the electron source.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct electron beam patterning of electro-optically active PEDOT:PSS

The optical and electronic tunability of the conductive polymer poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) has enabled emerging applications as diverse as bioelectronics, flexible electronics, and micro- and nano-photonics. High-resolution spatial patterning of PEDOT:PSS opens up opportunities for novel active devices in a range of fields. However, typical lithographic processes require tedious indirect patterning and dry etch processes, while solution-processing methods such as ink-jet printing have limited spatial resolution. Here, we report a method for direct write nano-patterning of commercially available PEDOT:PSS through electron-beam induced solubility modulation. The written structures are water stable and maintain the conductivity as well as electrochemical and optical properties of PEDOT:PSS, highlighting the broad utility of our method. We demonstrate the potential of our strategy by preparing prototypical nano-wire structures with feature sizes down to 250 nm, an order of magnitude finer than previously reported direct write methods, opening the possibility of writing chip-scale microelectronic and optical devices. We finally use the high-resolution writing capabilities to fabricate electrically-switchable optical diffraction gratings. We show active switching in this archetypal system with >95 % contrast at CMOS-compatible voltages of +2 V and -3 V, offering a route towards highly-miniaturized dynamic optoelectronic devices.

42 ENGINEERING↗

Three dimensions, two microscopes, one code: Automatic differentiation for x-ray nanotomography beyond the depth of focus limit

Conventional tomographic reconstruction algorithms assume that one has obtained pure projection images, involving no within-specimen diffraction effects nor multiple scattering. Advances in x-ray nanotomography are leading toward the violation of these assumptions, by combining the high penetration power of x-rays, which enables thick specimens to be imaged, with improved spatial resolution that decreases the depth of focus of the imaging system. We describe a reconstruction method where multiple scattering and diffraction effects in thick samples are modeled by multislice propagation and the 3D object function is retrieved through iterative optimization. We show that the same proposed method works for both full-field microscopy and for coherent scanning techniques like ptychography. Our implementation uses the optimization toolbox and the automatic differentiation capability of the open-source deep learning package TensorFlow, demonstrating a straightforward way to solve optimization problems in computational imaging with flexibility and portability.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Real-time X-ray Diffraction: Applications to Materials Characterization

With the high speed growth of materials it becomes necessary to develop measuring systems which also have the capabilities of characterizing these materials at high speeds. One of the conventional techniques of characterizing materials was X-ray diffraction. Film, which is the oldest method of recording the X-ray diffraction phenomenon, is not quite adequate in most circumstances to record fast changing events. Even though conventional proportional counters and scintillation counters can provide the speed necessary to record these changing events, they lack the ability to provide image information which may be important in some types of experiment or production arrangements. A selected number of novel applications of using X-ray diffraction to characterize materials in real-time are discussed. Also, device characteristics of some X-ray intensifiers useful in instantaneous X-ray diffraction applications briefly presented. Real-time X-ray diffraction experiments with the incorporation of image X-ray intensification add a new dimension in the characterization of materials. The uses of real-time image intensification in laboratory and production arrangements are quite unlimited and their application depends more upon the ingenuity of the scientist or engineer.

Rosemeier, R. G.↗

Quasi-Optical Transmission Line for 94-GHz Radar

A quasi-optical transmission line (QOTL) has been developed as a low-loss transmission line for a spaceborne cloudobserving radar instrument that operates at a nominal frequency of 94 GHz. This QOTL could also readily be redesigned for use in terrestrial millimeter-wave radar systems and millimeter-wave imaging systems. In the absence of this or another lowloss transmission line, it would be necessary to use a waveguide transmission line in the original radar application. Unfortunately, transmission losses increase and power-handling capacities of waveguides generally decrease with frequency, such that at 94 GHz, the limitation on transmitting power and the combined transmission and reception losses (greater than 5 dB) in a waveguide transmission line previously considered for the original application would be unacceptable. The QOTL functions as a very-lowloss, three-port circulator. The QOTL includes a shaped input mirror that can be rotated to accept 94-GHz transmitter power from either of two high-power amplifiers. Inside the QOTL, the transmitter power takes the form of a linearly polarized beam radiated from a feed horn. This beam propagates through a system of mirrors, each of which refocuses the beam to minimize diffraction losses. A magnetically biased ferrite disc is placed at one of the foci to utilize the Faraday effect to rotate the polarization of the beam by 45 degrees. The beam is then transmitted via an antenna system. The radar return (scatter from clouds, and/or reflections from other objects) is collected by the same antenna and propagates through the Faraday rotator in the reverse of the direction of propagation of the transmitted beam. In the Faraday rotator, the polarization of the received signal is rotated a further 45 degrees, so that upon emerging from the Faraday rotator, the received beam is polarized at 90 with respect to the transmitted beam. The transmitted and received signals are then separated by a wire-grid polarizer.

Perez, Raul M.↗

Real-time characterization of dislocation slip and twinning of shock-compressed molybdenum single crystals

Characterizing the fundamental micromechanisms activated during plastic deformation is critical to explain the macroscopic shock response of materials and develop accurate material models. In this paper, we investigate the orientation dependence, and the mediated slip and twin systems on [100] and [111] bcc molybdenum single crystals shock compressed up to 18 GPa with real-time Laue x-ray diffraction measurements. We report that dislocation slip along the {110} < 111 > and {112} < 111 > systems is the governing deformation mechanism during compression with negligible anisotropy observed at the Hugoniot state. Here, we provide real-time evidence that molybdenum undergoes deformation twinning along {11¯2} < 111 > during shock release.

36 MATERIALS SCIENCE↗

Gondola For High Altitude Planetary Science (GHAPS) Guide System Trade Study

The Gondola for High-Altitude Planetary Science (GHAPS) project is a balloon-borne astronomical observatory designed operate in the ultraviolet, Visible, and near-mid infrared spectral region. The GHAPS Optical Telescope Assembly (OTA) is designed around a 1-m aperture narrow field-of-view telescope with near-diffraction-limited performance. GHAPS will utilize Wallops Arc-Second Pointing System (WASP) for pointing the OTA with an accuracy of 1 arcsec or better. WASP relies heavily on a self-contained star tracker assembly to determine the OTA line of sight. Preliminary structural analysis indicates that potential misalignments could be present between the OTA line of sight and the star tracker FOV center during the expected flight conditions that could compromise GHAPS pointing accuracy.

Telescope Image Guider↗

Pressure dependence of the magnetic ground state in CePtSi 2

CePtSi 2 was reported to exhibit an antiferromagnetic order below T*=1.8 K at ambient pressure, a valence state change at ~1.2 GPa, and superconductivity in the range between 1.4 and 2.1 GPa with a maximum transition temperature of 0.14 K [T. Nakano et al., Phys. Rev. B 79, 172507 (2009)]. We have performed polycrystalline and single-crystal neutron diffraction experiments to determine the magnetic structure under ambient and high pressures. We found incommensurate magnetic peaks with a magnetic propagation vector of (0.32,0,0.11) at ambient pressure below T SDW ~ 1.25 K. Those magnetic peaks originate from a spin-density-wave order with the easy axis along the c axis and an averaged ordered moment of 0.45(5) μB , suggesting that there may be an intermediate phase between T* and T SDW . Applying pressures, the magnetic propagation vector shows no change and the magnetic order disappears around 1.0 GPa, which is much lower than the critical pressure for the superconducting phase. The results suggest that other than magnetic fluctuations may play a primary role in the superconducting pairing mechanism.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural origin of size effect on piezoelectric performance of Pb(Zr,Ti)O 3

Grain size effect plays a vital role in piezoelectric performance from both scientific and technological view. However, the underlying structural mechanism related to grain size is still unclear. In the present study, the structural mechanism of grain size effect on piezoelectric performance has been revealed in the prototype Pb(Zr, Ti)O 3 system by using in-situ synchrotron X-ray diffraction. The miniaturization of grain size tends to favor the appearance of higher symmetric tetragonal phase, while a single monoclinic phase is determined in the coarse-grained ceramics. The direct structural evidence reveals that both tetragonal and monoclinic phases in the fine-grained ceramics are less sensitive to the electric field, corresponding to the inferior piezoelectric performance, while the single monoclinic phase in the coarse-grained ceramics is more active to be driven by the electric field, generating good piezoelectric behavior. Both domain switching ability and lattice strain are suppressed with decreasing grain size, which directly leads to the deterioration in piezoelectric performance. In conclusion, the current results will benefit the structural understanding of the size effect of piezoelectric and other related systems.

36 MATERIALS SCIENCE↗

Understanding magnetic phase coexistence in Ru 2 Mn 1-x Fe x Sn Heusler alloys: A neutron scattering, thermodynamic, and phenomenological analysis

The random substitutional solid solution between the antiferromagnetic (AFM) full-Heusler alloy Ru 2 MnSn and the ferromagnetic (FM) full-Heusler alloy Ru 2 FeSn provides a rare opportunity to study FM-AFM phase competition in a near-lattice-matched, cubic system, with full solubility. At intermediate x in Ru 2 Mn 1-x Fe x Sn this system displays suppressed magnetic ordering temperatures, spatially coexisting FM and AFM order, and strong coercivity enhancement, despite rigorous chemical homogeneity. Here, we construct the most detailed temperature- and x-dependent understanding of the magnetic phase competition and coexistence in this system to date, combining wide-temperature-range neutron diffraction and small-angle neutron scattering with magnetometry and specific heat measurements on thoroughly characterized polycrystals. A complete magnetic phase diagram is generated, showing FM-AFM coexistence between x ≈ 0.30 and x ≈ 0.70. Furthermore, important insight is gained from the extracted length scales for magnetic phase coexistence (25–100 nm), the relative magnetic volume fractions and ordering temperatures, and remarkable x-dependent trends in magnetic and electronic contributions to specific heat. An unusual feature in the magnetic phase diagram (an intermediate FM phase) is also shown to arise from an extrinsic effect related to a minor Ru-rich secondary phase. The established magnetic phase diagram is then discussed with the aid of phenomenological modeling, clarifying the nature of the mesoscale phase coexistence with respect to the understanding of disordered Heisenberg models.

36 MATERIALS SCIENCE↗

A diffraction-limited far-infrared imager for the KAO

We describe both our current instrument and a follow-on instrument expected to be operational at the start of the next flight year on the KAO. The current instrument uses a 20-channel bolometer array arranged in two columns of 10 detectors each. Broadband observations can be made at the true diffraction limit, lambda/2D, at either 50 or 100 microns during a flight. Our forthcoming system will use two arrays of 3 x 10 detectors to enable simultaneous imaging at both 50 and 100 microns at the KAO diffraction limit for each wavelength. Observing modes and typical sensitivities will be discussed.

Harvey, Paul M.↗