Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

The optimal use of segmentation for sampling calorimeters

One of the key design choices of any sampling calorimeter is how fine to make the longitudinal and transverse segmentation. Here, to inform this choice, we study the impact of calorimeter segmentation on energy reconstruction. To ensure that the trends are due entirely to hardware and not to a sub-optimal use of segmentation, we deploy deep neural networks to perform the reconstruction. These networks make use of all available information by representing the calorimeter as a point cloud. To demonstrate our approach, we simulate a detector similar to the forward calorimeter system intended for use in the ePIC detector, which will operate at the upcoming Electron Ion Collider. We find that for the energy estimation of isolated charged pion showers, relatively fine longitudinal segmentation is key to achieving an energy resolution that is better than 10% across the full phase space. These results provide a valuable benchmark for ongoing EIC detector optimizations and may also inform future studies involving high-granularity calorimeters in other experiments at various facilities.

47 OTHER INSTRUMENTATION↗

Antenna arrays for neutrino mass measurements with cyclotron radiation emission spectroscopy

Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for precision measurements of kinetic energies of charged particles, pioneered by the Project 8 experiment to measure the neutrino mass using the tritium end-point method. It was recently employed for the first time to measure the molecular tritium spectrum and place a limit on the neutrino mass using a cubic-centimeter-scale detector. Future direct neutrino mass experiments are developing the technique to overcome the systematic and statistical limitations of current detectors. Here, this paper describes one such approach, namely the use of antenna arrays for CRES in free space. Phenomenology, detector design, simulation, and performance estimates are discussed, culminating with an example design with a projected sensitivity of 𝑚 𝛽 < ⁢0.04 eV/𝑐 2 . Prototype antenna array measurements are also shown for a demonstrator-scale setup as a benchmark for the simulation. By consolidating these results, this paper serves as a comprehensive reference for the development and performance of antenna arrays for CRES.

Physics - Nuclear physics and radiation physics↗

Pseudorapidity distributions of charged particles in p-p-bar or p-p collisions at high energies and predictions at ultrahigh energies

Pseudorapidity distributions of charged particles produced in p-p-bar or p-p collisions at different energies were reported by the UA5, UA1, P238, CDF, and ALICE collaborations. A multisource ideal gas model is used to fit the experimental data in this paper. According to the parameter values obtained from fitting the data, we find different linear relationships between different parameters and logarithmic center-of-mass energy. A prediction for the pseudorapidity distributions of charged particles produced in p-p-bar or p-p collisions at the higher Large Hadron Collider energies is given.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved time-domain accuracy standards for model gravitational waveforms

Model gravitational waveforms must be accurate enough to be useful for detection of signals and measurement of their parameters, so appropriate accuracy standards are needed. Yet these standards should not be unnecessarily restrictive, making them impractical for the numerical and analytical modelers to meet. The work of Lindblom, Owen, and Brown [Phys. Rev. D 78, 124020 (2008)] is extended by deriving new waveform accuracy standards which are significantly less restrictive while still ensuring the quality needed for gravitational-wave data analysis. These new standards are formulated as bounds on certain norms of the time-domain waveform errors, which makes it possible to enforce them in situations where frequency-domain errors may be difficult or impossible to estimate reliably. These standards are less restrictive by about a factor of 20 than the previously published time-domain standards for detection, and up to a factor of 60 for measurement. These new standards should therefore be much easier to use effectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gravitational wave energy spectrum of a parabolic encounter

We derive an analytic expression for the energy spectrum of gravitational waves from a parabolic Keplerian binary by taking the limit of the Peters and Mathews spectrum for eccentric orbits. This demonstrates that the location of the peak of the energy spectrum depends primarily on the orbital periapse rather than the eccentricity. We compare this weak-field result to strong-field calculations and find it is reasonably accurate ({approx}10%) provided that the azimuthal and radial orbital frequencies do not differ by more than {approx}10%. For equatorial orbits in the Kerr spacetime, this corresponds to periapse radii of r{sub p} > or approx. 20M. These results can be used to model radiation bursts from compact objects on highly eccentric orbits about massive black holes in the local Universe, which could be detected by the Laser Interferometer Space Antenna (LISA).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Online and Offline Identification of False Data Injection Attacks in Battery Sensors Using a Single Particle Model

The cells in battery energy storage systems are monitored, protected, and controlled by battery management systems whose sensors are susceptible to cyberattacks. False data injection attacks (FDIAs) targeting batteries’ voltage sensors affect cell protection functions and the estimation of critical battery states like the state of charge (SoC). Inaccurate SoC estimation could result in battery overcharging and over discharging, which can have disastrous consequences on grid operations. This paper proposes a three-pronged online and offline method to detect, identify, and classify FDIAs corrupting the voltage sensors of a battery stack. To accurately model the dynamics of the series-connected cells a single particle model is used and to estimate the SoC, the unscented Kalman filter is employed. FDIA detection, identification, and classification was accomplished using a tuned cumulative sum (CUSUM) algorithm, which was compared with a baseline method, the chi-squared error detector. Online simulations and offline batch simulations were performed to determine the effectiveness of the proposed approach. Throughout the batch simulations, the CUSUM algorithm detected attacks, with no false positives, in 99.83% of cases, identified the corrupted sensor in 97% of cases, and determined if the attack was positively or negatively biased in 97% of cases.

25 ENERGY STORAGE↗

Modeling the performance of a photon counting x-ray detector for CT: Energy response and pulse pileup effects

Purpose: Recently, photon counting x-ray detectors (PCXDs) with energy discrimination capabilities have been developed for potential use in clinical computed tomography (CT) scanners. These PCXDs have great potential to improve the quality of CT images due to the absence of electronic noise and weights applied to the counts and the additional spectral information. With high count rates encountered in clinical CT, however, coincident photons are recorded as one event with a higher or lower energy due to the finite speed of the PCXD. This phenomenon is called a ''pulse pileup event'' and results in both a loss of counts (called ''deadtime losses'') and distortion of the recorded energy spectrum. Even though the performance of PCXDs is being improved, it is essential to develop algorithmic methods based on accurate models of the properties of detectors to compensate for these effects. To date, only one PCXD (model DXMCT-1, DxRay, Inc., Northridge, CA) has been used for clinical CT studies. The aim of that study was to evaluate the agreement between data measured by DXMCT-1 and those predicted by analytical models for the energy response, the deadtime losses, and the distorted recorded spectrum caused by pulse pileup effects. Methods: An energy calibration was performed using {sup 99m}Tc (140 keV), {sup 57}Co (122 keV), and an x-ray beam obtained with four x-ray tube voltages (35, 50, 65, and 80 kVp). The DXMCT-1 was placed 150 mm from the x-ray focal spot; the count rates and the spectra were recorded at various tube current values from 10 to 500 {mu}A for a tube voltage of 80 kVp. Using these measurements, for each pulse height comparator we estimated three parameters describing the photon energy-pulse height curve, the detector deadtime {tau}, a coefficient k that relates the x-ray tube current I to an incident count rate a by a=kxI, and the incident spectrum. The mean pulse shape of all comparators was acquired in a separate study and was used in the model to estimate the distorted recorded spectrum. The agreement between data measured by the DXMCT-1 and those predicted by the models was quantified by the coefficient of variation (COV), i.e., the root mean square difference divided by the mean of the measurement. Results: Photon energy versus pulse height curves calculated with an analytical model and those measured using the DXMCT-1 were in agreement within 0.2% in terms of the COV. The COV between the output count rates measured and those predicted by analytical models was 2.5% for deadtime losses of up to 60%. The COVs between spectra measured and those predicted by the detector model were within 3.7%-7.2% with deadtime losses of 19%-46%. Conclusions: It has been demonstrated that the performance of the DXMCT-1 agreed exceptionally well with the analytical models regarding the energy response, the count rate, and the recorded spectrum with pulse pileup effects. These models will be useful in developing methods to compensate for these effects in PCXD-based clinical CT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-204-05: Simulations of a Portal Imaging System for Conformal and Intensity Modulated Fast Neutron Therapy

Purpose: The University of Washington Medical Center offers neutron therapy for the palliative and definitive treatment of selected cancers. In vivo field verification has the potential to improve the safe and effective delivery of neutron therapy. We propose a portal imaging method that relies on the creation of positron emitting isotopes (11C and 15O) through (n, 2n) reactions with a PMMA plate placed below the patient. After field delivery, the plate is retrieved from the vault and imaged using a reader that detects annihilation photons. The spatial pattern of activity produced in the PMMA plate provides information to reconstruct the neutron fluence map needed to confirm treatment delivery. Methods: We used MCNP to simulate the accumulation of 11C activity in a slab of PMMA 2 mm thick, and GATE was used to simulate the sensitivity and spatial resolution of a prototype imaging system. BGO crystal thicknesses of 1 cm, 2 cm and 3 cm were simulated with detector separations of 2 cm. Crystal pitches of 2 mm and 4 mm were evaluated. Back-projection of the events was used to create a planar image. The spatial resolution was taken to be the FWHM of the reconstructed point source image. Results: The system sensitivity for a point source in the center of the field of view was found to range from 58% for 1 cm thick BGO with 2 mm crystal pitch to 74% for the 3 cm thick BGO crystals with 4 mm crystal pitch. The spatial resolution at the center of the field of view was found to be 1.5 mm for the system with 2 mm crystal pitch and 2.8 mm for the system with the 4 mm crystal pitch. Conclusion: BGO crystals with 4 mm crystal pitch and 3 cm length would offer the best sensitivity reader.

07 ISOTOPE AND RADIATION SOURCES↗

Detection of reflected Cherenkov light from extensive air showers in the SPHERE experiment as a method of studying superhigh energy cosmic rays

Although a large number of experiments were carried out during the last few decades, the uncertainty in the spectrum of all nuclei of primary cosmic rays (PCRs) with superhigh energies is still high, and the results of many experiments on nuclear composition of PCRs are contradictory. An overview of the SPHERE experiment on detecting Vavilov-Cherenkov radiation from extensive air shower (EAS) reflected from a ground snow surface is given. A number of experimental studies implementing this method are presented and their results are analyzed. Some other popular methods of studying PCRs with superhigh energies (E{sub 0} > 10{sup 15} eV) and their main advantages and drawbacks are briefly considered. The detecting equipment of the SPHERE-2 experiment and the technique of its calibration are considered. The optical properties of snow, which are important for experiments on reflected Cherenkov light (CL) from EAS, are discussed and the history of observing reflected EAS CL is described. The algorithm of simulating the detector response and calculating the fiducial acceptance of shower detection is described. The procedure of processing the experimental data with a subsequent reconstruction of the spectrum of all PCR nuclei and analysis of the mass composition is shown. The first results of reconstructing the spectrum and separating groups of cosmic-ray nuclei with high energies in the SPHERE-2 experiment are presented. Main sources of systematic errors are considered. The prospects of developing the technique of observation of reflected EAS CL in future experiments are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Das ist der HAMMER: consistent new physics interpretations of semileptonic decays

Abstract Precise measurements of $$b\rightarrow c\tau \bar{\nu }$$ b → c τ ν ¯ decays require large resource-intensive Monte Carlo (MC) samples, which incorporate detailed simulations of detector responses and physics backgrounds. Extracted parameters may be highly sensitive to the underlying theoretical models used in the MC generation. Because new physics (NP) can alter decay distributions and acceptances, the standard practice of fitting NP Wilson coefficients to SM-based measurements of the $$R(D^{(*)})$$ R ( D ( ∗ ) ) ratios can be biased. The newly developed software tool enables efficient reweighting of MC samples to arbitrary NP scenarios or to any hadronic matrix elements. We demonstrate how allows avoidance of biases through self-consistent fits directly to the NP Wilson coefficients. We also present example analyses that demonstrate the sizeable biases that can otherwise occur from naive NP interpretations of SM-based measurements. The library is presently interfaced with several existing experimental analysis frameworks and we provide an overview of its structure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Understanding materials microstructure and behavior at the mesoscale

Taking the mesoscale to mean length and time scales at which a material’s behavior is too complex to be understood by construction from the atomistic scale, we focus on three-dimensional characterization and modeling of mesoscale responses of polycrystals to thermal and mechanical loading. Both elastic and plastic internal structural responses are now accessible via high-energy x-ray probes. The combination of diffraction experiments and computed tomography, for example, is yielding new insights into how void formation correlates with microstructural features such as grain boundaries and higher-order junctions. The resulting large, combined data sets allow for validation of micromechanical and thermal simulations. As detectors improve in resolution, quantum efficiency, and speed of readout, data rates and data volumes present computational challenges. Spatial resolutions approach one micrometer, while data sets span a cubic millimeter. Examples are given of applications to tensile deformation of copper, grain growth in nickel and titanium, and fatigue cracks in superalloys.

36 MATERIALS SCIENCE↗

Bubble masks for time-encoded imaging of fast neutrons.

Time-encoded imaging is an approach to directional radiation detection that is being developed at SNL with a focus on fast neutron directional detection. In this technique, a time modulation of a detected neutron signal is induced typically, a moving mask that attenuates neutrons with a time structure that depends on the source position. An important challenge in time-encoded imaging is to develop high-resolution two-dimensional imaging capabilities; building a mechanically moving high-resolution mask presents challenges both theoretical and technical. We have investigated an alternative to mechanical masks that replaces the solid mask with a liquid such as mineral oil. Instead of fixed blocks of solid material that move in pre-defined patterns, the oil is contained in tubing structures, and carefully introduced air gaps bubbles propagate through the tubing, generating moving patterns of oil mask elements and air apertures. Compared to current moving-mask techniques, the bubble mask is simple, since mechanical motion is replaced by gravity-driven bubble propagation; it is flexible, since arbitrary bubble patterns can be generated by a software-controlled valve actuator; and it is potentially high performance, since the tubing and bubble size can be tuned for high-resolution imaging requirements. We have built and tested various single-tube mask elements, and will present results on bubble introduction and propagation as a function of tubing size and cross-sectional shape; real-time bubble position tracking; neutron source imaging tests; and reconstruction techniques demonstrated on simple test data as well as a simulated full detector system.

Brubaker, Erik↗

A Prototype Thick-Target Bremsstrahlung Model with Angularly-Dependent Emission in the MCNP6 ® Code

This document summarizes the current thick-target bremsstrahlung (TTB) model in MCNP and provides test results for an alternative implementation to improve the accuracy with reduced cost compared to full electron transport. It has been observed that the current TTB model produces inaccurate results in problems where the medium is thick with respect to electrons, but the photon distribution in the problem has a strong directionality. An example of such a simulation is detectors surrounding a metal target irradiated with a radiographic beam of high energy photons. The primary cause of this discrepancy is the current TTB method emits all bremsstrahlung photons in the same direction as the primary electron produced from each (γ, e ± ) interaction, leading to artificially forward peaked photon distributions for intermediate to high-energy incident photons. To improve the TTB model, we have implemented an angularly-dependent TTB model in a developer version of the MCNP6 ® code; for developers, this was done on the branch prototype/angular_ttb in the mcnp6 repo on bitbucket. The angularly-dependent TTB model accounts for the energy and scattering of electrons as they slow down in the current material, but does not sample the computationally expensive energy straggling, secondary electron events, and tracking electrons; this approach is significantly less computationally expensive than full electron transport and can be comparable to the original TTB method for problems with sufficiently complex materials and geometry. To evaluate the method, we have modeled a simple problem of a beam of 5 MeV photons incident on a sphere of plutonium surrounded by detectors at different deflection angles. For this problem, the angularly-dependent TTB produces a photon flux within 8.0% for a 90 degree deflection angle and 0.8% along the beam axis, as compared to the electron transport solution. This is an improvement compared to a 43% and 81% discrepancy with the original TTB method, respectively. The rest of this work includes the following: the first section details the current TTB treatment in MCNP, which has not been well documented elsewhere. Then, the modified TTB algorithm is detailed and the approximations compared to the condensed history algorithm are compared. Results are given comparing the two TTB methods to the condensed history transport algorithm. The appendix includes details for code developers on relevant electron transport implementation details and potential code improvements for future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Intensity Gamma Ray Source Scintillation Attenuation Spectrometer and Filter Stack Monoenergetic Calibration

The Laser-Based X-ray Radiographic Imaging team at Los Alamos National Lab is looking for a monoenergetic MeV X-ray source to both verify our Monte Carlo N-particle simulations of detector performance and calibrate the instruments for future measurements. Funded by the Laboratory Directed Research and Development (LDRD) program, our overall goal is to improve the radiographic quality and reliability of laser-based X-ray sources for deployment at both dynamic and static radiography facilities. Laser-based X-ray sources have demonstrated smaller spot sizes to current electron accelerator based sources. The smaller laser spot size leads to significantly improved resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Threat Sources for Creating Synthetic Urban Search Data

Equivalent point source energy emission distributions were computed for various threat sources for use in simulating the detector responses for urban search scenarios. The sources include standard isotopic sources used in detector testing, medical and industrial sources occasionally encountered in urban searches, and several types of special nuclear materials. Most of the equivalent point source distributions represent small sources inside some amount of shielding, but the special nuclear material sources represent volumetrically distributed sources in spheres of metal. Text-based inputs for emission distributions are available for the Monte Carlo transport codes Monte Carlo N-Particle, SCALE/MAVRIC, and Omnibus/Shift, any of which can easily be converted to other formats. These sources were developed for use in the Radiological Anomaly Detection and Identification (RADAI) project and the follow-on project, the RADAI-Extended project, sponsored by the National Nuclear Security Administration Office of Defense Nuclear Nonproliferation Research and Development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗