Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Identification of new transitions and levels in 163 Gd from $β$-decay studies

Background: Neutron-rich nuclei in the mass region around A = 160 have been and will continue to be of interest for the study of nuclear structure because of the rapid onset of deformation between 88 and 90 neutrons. The observation of detailed changes in nuclear structures within this mass region has provided and will continue to provide insight into the nuclear force. Purpose: Investigations of γ rays emitted following Eu 163 β -decay to Gd 163 have been performed for evaluation of the nuclear structure of Gd 163 . Method: Data were collected at the LeRIBSS station of the Holifield Radioactive Ion Beam Facility at Oak Ridge National Laboratory with an array of four Clover HPGe detectors for γ -rays and two plastic scintillators for β detection. The γ rays were identified as belonging to Gd 163 via mass selection and γ – γ – β , x-ray- γ , or γ – γ coincidences. Results: In total 107 new γ -ray transitions were observed in Gd 163 from 53 newly identified levels. Conclusions: We report the structure of Gd 163 has been identified for the first time. This structure has been evaluated in comparison to projected shell model, and potential energy surface calculations with good agreement.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New transitions and levels for 163 Tb obtained from β-decay studies

Transitions in 163 Tb following β decay of 163 Gd were obtained as part of investigations of γ rays emitted following 163 Euβ decay to 163 Gd. In this work, detailed analysis of the low-energy structure of 163 Tb has been carried out with these data to expand previous β-decay studies and reactions studies of levels in 163 Tb. Data were collected at the LeRIBSS station of the Holifield Radioactive Ion Beam Facility at Oak Ridge National Laboratory with an array of four Clover HPGe detectors for γ rays and two plastic scintillators for β detection. The γ rays were identified as belonging to 163 Gd and 163 Tb via mass selection and γ-γ-β, γ-γ, or γ-x-ray coincidence. In total, 38 new γ-ray transitions were observed in 163 Tb from 15 newly identified levels and 12 previously identified levels. Potential energy surface calculations were performed which support a rigid prolate deformation. Previously identified unplaced transitions in 163 Tb have been placed within the level scheme of 163 Tb and additional states and transitions have been identified.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Onset of band structure in 70 Ga

Excited states in the odd-odd nucleus 70 Ga were studied using the 62 Ni( 14 C, αpn) fusion-evaporation reaction at the John D. Fox Superconducting Accelerator Laboratory at Florida State University with a 50 MeV beam. Depopulating γ rays were measured in coincidence with a Compton-suppressed Ge array consisting of three Clover detectors and seven single-crystal detectors. Analysis of γ–γ coincidences led to the addition of 16 new transitions to the 70 Ga level scheme, including transitions associated with the onset of a new positive-parity band structure likely based on the πg 9/2 ⊗ νg 9/2 configuration. Spins and parities were assigned using directional correlation of oriented nuclei (DCO) ratios and linear polarization measurements. Shell-model calculations with the JUN45 effective interaction reproduce the excitation energies of the positive-parity states reasonably well but predict negative-parity states that are typically 400–500 keV lower than observed. Furthermore, total Routhian surface calculations for the lowest positive-parity configuration with signature α = 0 indicate significant triaxiality (γ ≈ −20°) and the development of competing non-collective excitations at J = 8, corresponding to the experimentally observed onset of the positive-parity band. Similar features are found in the calculated surfaces for the lowest negative-parity states with α = 0.

59 ≤ A ≤ 89↗

Final Results of the M AJORANA D EMONSTRATOR ’s Search for Double-Beta Decay of 76 Ge to Excited States of 76 Se

76 Ge can 𝛽⁢𝛽 decay into three possible excited states of 76 Se , with the emission of two or, if the neutrino is Majorana, zero neutrinos. None of these six transitions have yet been observed. The M AJORANA D EMONSTRATOR was designed to study 𝛽⁢𝛽 decay of 76 Ge using a low background array of high purity germanium detectors. With 98.2 kg-y of isotopic exposure, the demonstrator sets the strongest half-life limits to date for all six transition modes. For 2⁢𝜈⁢𝛽⁢𝛽 to the 0$^+_1$ state of 76 Se , this search has begun to probe for the first time half-life values predicted using modern many-body nuclear theory techniques, setting a limit of 𝑇 1/2 > 1.5 × 10 24 y (90% CL).

Majorana neutrinos↗

Three-Wave Mixing Kinetic Inductance Traveling-Wave Amplifier with Near-Quantum-Limited Noise Performance

We present a theoretical model and experimental characterization of a microwave kinetic inductance traveling-wave (KIT) amplifier, whose noise performance, measured by a shot-noise tunnel junction (SNTJ), approaches the quantum limit. Biased with a dc current, this amplifier operates in a three-wave mixing fashion, thereby reducing by several orders of magnitude the power of the microwave pump tone and associated parasitic heating compared to conventional four-wave mixing KIT amplifier devices. It consists of a 50 Ω artificial transmission line whose dispersion allows for a controlled amplification bandwidth. We measure $16.5^{+1}_{–1.3}$ dB of gain across a 2 GHz bandwidth with an input 1 dB compression power of –63 dBm, in qualitative agreement with theory. Using a theoretical framework that accounts for the SNTJ-generated noise entering both the signal and idler ports of the KIT amplifier, we measure the system-added noise of an amplification chain that integrates the KIT amplifier as the first amplifier. This system-added noise, 3.1 ± 0.6 quanta (equivalent to 0.66 ± 0.15 K) between 3.5 and 5.5 GHz, is the one that a device replacing the SNTJ in that chain would see. This KIT amplifier is therefore suitable to read large arrays of microwave kinetic inductance detectors and promising for multiplexed superconducting qubit readout.

42 ENGINEERING↗

Neutron Response of the EJ-254 Boron-Loaded Plastic Scintillator

Organic scintillators doped with capture agents provide a detectable signal for neutrons over a broad energy range. This work characterizes the fast and slow neutron response of EJ-254, an organic plastic scintillator with 5 loading by weight. For fast neutrons, the primary mechanism for light generation in organic scintillators is n-p elastic scattering. To study the fast neutron response, the proton light yield of EJ-254 was measured at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a broad-spectrum neutron source and a double time-of-flight technique, the EJ-254 proton light yield was obtained over the energy range of approximately 270 keV to 4.5 MeV and determined to be in agreement with other plastic scintillators comprised of the same polymer base. To isolate the slow neutron response, an AmBe source with polyethylene moderator was made incident on the EJ-254 scintillator surrounded by an array of EJ-309 observation detectors. Events in the EJ-254 target coincident with the signature 477.6 keV γ ray (resulting from de-excitation of the residual 7Li nucleus following boron neutron capture) were identified. Pulse shape discrimination was used to evaluate the temporal differences in the response of EJ-254 scintillation signals arising from γ-ray and fast/slow neutron interactions. Clear separation between γ-ray and fast neutrons signals was not achieved and the neutron capture feature was observed to overlap both the γ-ray and fast neutron bands. Taking into account the electron light nonproportionality, the neutron capture light yield in EJ-254 was determined to be 89.4±1.1 keVee.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct measurement of the muonic content of extensive air showers between 2 $\times$ 10 17 and 2 $\times$ 10 18 eV at the Pierre Auger Observatory

The hybrid design of the Pierre Auger Observatory allows for the measurement of the properties of extensive air showers initiated by ultra-high energy cosmic rays with unprecedented precision. By using an array of prototype underground muon detectors, we have performed the first direct measurement, by the Auger Collaboration, of the muon content of air showers between 2 $\times$ 10 17 and 2 $\times$ 10 18 eV. We have studied the energy evolution of the attenuation-corrected muon density, and compared it to predictions from air shower simulations. The observed densities are found to be larger than those predicted by models. We quantify this discrepancy by combining the measurements from the muon detector with those from the Auger fluorescence detector at 10 17.5 eV and 10 18 eV. We find that, for the models to explain the data, an increase in the muon density of 38% $±$4%(12%) $±^{21\%}_{18\%}$ for EPOS-LHC, and of 50%(53%) $±$4%(13%) $±^{23\%}_{20\%}$ for QGSJETII-04, is respectively needed.

79 ASTRONOMY AND ASTROPHYSICS↗

High Energy Physics Network Requirements Review (Final Report, July-October 2020)

Throughout 2020, ESnet and the Office of High Energy Physics (HEP) of the DOE SC organized an ESnet requirements review of HEP-supported activities. Preparation for this event included identification of key stakeholders: program and facility management, research groups, technology providers, and a number of external observers. These individuals were asked to prepare formal case study documents about their relationship to the HEP program to build a complete understanding of the current, near-term, and long-term status, expectations, and processes that will support the science going forward. A series of pre-planning meetings better prepared case study authors for this task, along with guidance on how the review would proceed in a virtual fashion.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scaler Rates from the Pierre Auger Observatory: A New Proxy of Solar Activity

The modulation of low-energy galactic cosmic rays reflects interplanetary magnetic field variations and can provide useful information on solar activity. An array of ground-surface detectors can reveal the secondary particles, which originate from the interaction of cosmic rays with the atmosphere. In this work, we present an investigation of the low-threshold rate (scaler) time series recorded in 16 yr of operation by the Pierre Auger Observatory surface detectors in Malargüe, Argentina. Through an advanced spectral analysis, we detected highly statistically significant variations in the time series with periods ranging from the decadal to the daily scale. We investigate their origin, revealing a direct connection with solar variability. Thanks to their intrinsic very low noise level, the Auger scalers allow a thorough and detailed investigation of the galactic cosmic-ray flux variations in the heliosphere at different timescales and can, therefore, be considered a new proxy of solar variability.

79 ASTRONOMY AND ASTROPHYSICS↗

New Experiments for Detecting Emissions from Fission

Ensuring that nuclear science and technology is used solely for peaceful purposes is one of the most pressing challenges facing our society. The Consortium for Monitoring, Technology, and Verification (MTV) mission is to help meet this challenge by providing advanced technology and trained talent for careers in nuclear security and nonproliferation. The study of nuclear fission is one area of interest in the MTV. We are performing new experiments for the characterization of neutron and gamma ray emissions from fission fragments. These emissions are signatures for the detection and characterization of nuclear materials. To perform these experiments, we have developed Fission Sphere (FS-3), an array of forty organic stilbene detectors operated in time-coincidence. The FS-3 is used to measure the prompt emissions of neutrons and gamma rays from Cf-252 spontaneous fission. These new data will be used to validate physics-based prediction codes, including CGMF and FREYA, and will be useful in future ENDF and ENSDF evaluations. This paper will present results from the first experiments using FS-3 and a Cf-252 spontaneous fission source. It will compare the experimental results with predictions from theory and Monte Carlo simulation. Specifically, we will describe the correlations among energy, multiplicity, and angles of emitted particles. We will also discuss the application of these correlations in multiplicity counting techniques, which are widely used in nuclear safeguards.

Pozzi, S. A.↗

Estimating β eff from static, late-time Feynman neutron noise measurements

The effective delayed neutron fraction, β eff , is a kinematic parameter describing the contribution of delayed neutrons to the effective multiplication factor, $\kappa$ eff , and is of great interest to the nuclear criticality safety community and beyond. In fact, $\kappa$ eff presently must be inferred (as opposed to directly measured) since variables like β eff must be obtained from simulation, reference tables, or a dynamic or pulsed measurement where the assembly of fissile material is perturbed and not in steady state. Several recent works have proposed neutron noise techniques to estimate β eff from static measurements (such as benchmark experiments). This work experimentally investigates an approach based on looking at late-time (up to thousands of seconds) correlated neutrons in Feynman histograms. This work utilizes measurements of weapons grade plutonium and highly enriched uranium to construct late-time Feynman histograms and investigate a proposed methodology of estimating β eff from a fit of the distribution. Data is shown from both He-3 detectors and an organic scintillator array. This work is preliminary in nature, demonstrating some experimental feasibility and proposing improvements for future investigations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and Construction of a High-Resolution Hodoscope for the GlueX Experiment with High-Statistics Analysis of the p0, ¿, and ¿1 Photoproduction Cross Sections from the RadPhi Experiment

Differential cross sections for forward-angle photoproduction of p0, ¿, and ¿ 1 pseudoscalar mesons were measured using data from the RadPhi experiment conducted in Hall B at Jef ferson Lab. RadPhi utilized a tagged bremsstrahlung photon beam incident on a stationary 9Be target, with a detector system configured to trigger on a recoil proton in coincidence with multiple neutral showers in the calorimeter. Events were reconstructed and subjected to kinematic constraints, with background suppressed via sideband subtraction guided by Monte Carlo modeling of background contributions. Cross sections were extracted over the photon energy range 4.4– 5.4 GeV and binned in invariant momentum transfer t, providing measurements from one of the first high-statistics experiments of forward ¿ and ¿1 pro duction from a nuclear target at these energies. Acceptance corrections were applied using a detailed GEANT-based simulation of the detector geometry and response. The resulting cross sections are consistent with 2020 CLAS results, when scaled by the number of protons in beryllium, and show broad agreement with other data and theoretical models. In parallel, a high-resolution photon tagger detector, the Tagger Microscope (TAGM), was designed, constructed, and commissioned for the GlueX experiment in Hall D at Jefferson Lab. The TAGM was developed to provide high-rate tagging capability in the coherent bremsstrahlung peak by detecting post-bremsstrahlung electrons across a one GeV range along the focal plane of the tagging spectrometer. The detector consists of a 5ˆ102 array of 2ˆ2 mm2 square BCF-20 plastic scintillating fibers thermally fused to BCF-98 light guide fibers optically coupled to silicon photomultipliers. These fibers are mounted in a precision machined framework enabling fine positional adjustments to maintain precise alignment with post-bremsstrahlung electron trajectories, while ensuring mechanical rigidity, thermal stability, optical isolation, minimal inactive area, and radiation shielding for electronics. The construction effort involved extensive testing of fiber quality, light transmission, thermal fusing, radiation hardness, and defect analysis using SEM and EDX techniques. Following its installation and commissioning, the TAGM became a critical component of the GlueX beamline, enabling high-rate tagging essential for studies of hybrid mesons and gluonic ex citations.

McIntyre, James [Univ. of Connecticut, Storrs, CT ↗

The ultrafast pixel array camera system and its applications in high energy density physics

Diagnostics in high energy density physics, shock physics, and related fields are primarily driven by a need to record rapidly time-evolving signals in single-shot events. These measurements are often limited by channel count and signal degradation issues on cable links between the detector and digitizer. Here we present the Ultrafast Pixel Array Camera (UPAC), a compact and flexible detector readout system with 32 waveform-recording channels at up to 10 Gsample/s and 1.8 GHz analog bandwidth. The compact footprint allows the UPAC to be directly embedded in the detector environment. A key enabling technology is the PSEC4A chip, an eight-channel switch-capacitor array sampling device with up to 1056 samples/channel. The UPAC system includes a high-density input connector that can plug directly into an application-specific detector board, programmable control, and serial readout, with less than 5 W of power consumption in full operation. We present the UPAC design and characterization, including a measured timing resolution of ~20 ps or better on acquisitions of sub-nanosecond pulses with minimal system calibrations. Example applications of the UPAC are also shown to demonstrate operation of a solid-state streak camera, an ultrafast imaging array, and a neutron time-of-flight spectrometer.

47 OTHER INSTRUMENTATION↗

Cosmic ray spectrum from 250 TeV to 10 PeV using IceTop

We report here an extension of the measurement of the all-particle cosmic-ray spectrum with IceTop to lower energy. The new measurement gives full coverage of the knee region of the spectrum and reduces the gap in energy between previous IceTop and direct measurements. With a new trigger that selects events in closely spaced detectors in the center of the array, the IceTop energy threshold is lowered by almost an order of magnitude below its previous threshold of 2 PeV. In this paper, we explain how the new trigger is implemented, and we describe the new machine-learning method developed to deal with events with very few detectors hit. Here, we compare the results with previous measurements by IceTop and others that overlap at higher energy and with HAWC and Tibet in the 100 TeV range.

79 ASTRONOMY AND ASTROPHYSICS↗

In-flight performance of the XRISM/Resolve detector system

The Resolve instrument was launched on board the XRISM observatory in early September 2023. The Resolve spectrometer is based on a high-sensitivity X-ray calorimeter detector system (DS) that has been successfully deployed in many ground and sub-orbital spectrometers. However, the Resolve instrument is the first long-term implementation in space. The instrument will provide essential diagnostics for nearly every class of X-ray emitting objects, from galactic supernova remnants to the outskirts of galaxy clusters, without degradation for spatially extended objects. The Resolve DS consists of a 36-pixel microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the DS demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous bandpass from below 0.3 keV to above 12 keV and a timing precision better than 100μs. An anti-coincidence detector placed directly behind the microcalorimeter array effectively suppresses background. The detector energy-resolution budget included terms for interference from the Resolve cooling system and the spacecraft. Additional terms for energy-scale stability, on-orbit effects, and use of mid-grade events were also included, predicting an end-of-life, on-orbit performance for high- and mid-resolution grade events that meet the requirement of 7 eV FWHM at 6 keV. Here, we discuss the actual on-orbit performance of the Resolve DS and compare this with the performance in pre-flight testing, on-orbit predictions, and the almost identical Hitomi/SXS instrument. We will also discuss the on-orbit gain stability, an assessment of on-orbit interference, and measurements of the on-orbit background.

Astronomy and AstroPhysics↗

Identification of Prompt Proton Emission in $N = Z - 1$ 61 Ga: Isospin Symmetry at the Limit of Nuclear Binding

Excited states in the proton drip line nucleus 61 Ga were populated via the fusion-evaporation reaction 24 Mg ⁢( 40 Ca, 𝑝⁢2⁢𝑛)⁢ 61 Ga. The experimental setup at Argonne National Laboratory comprised a novel combination of the Gammasphere array with two CD-shaped double-sided Si-strip detectors inside the Microball CsI(Tl) charged-particle detection array, as well as the Neutron-Shell liquid scintillators and the Fragment Mass Analyzer. Owing to the setup’s unprecedented in-beam proton spectroscopy and tracking capabilities, a coincidence between a 957.6(5)-keV 𝛾 ray and a 1.876(24)-MeV proton line was observed, which identifies the quasibound proton 𝜋⁢𝑔 9/2 single-particle state in 61 Ga at 𝐸 𝑥 = 2150⁢(34) keV. This probes isospin symmetry at the limit of nuclear binding by providing a unique challenge for the shell-model interpretation of mirror nuclei beyond doubly magic 56 Ni .

Hrabar, Yuliia [Lund Univ. (Sweden)] (ORCID:000000↗

Data Compression in the NEXT-100 Data Acquisition System

NEXT collaboration detectors are based on energy measured by an array of photomultipliers (PMT) and topological event filtering based on an array of silicon photomultipliers (SiPMs). The readout of the PMT sensors for low-frequency noise effects and detector safety issues requires a grounded cathode connection that makes the readout AC-couple with variations in the signal baseline. Strict detector requirements of energy resolution better than 1% FWHM require a precise baseline reconstruction that is performed offline for data analysis and detector performance characterization. Baseline variations make it inefficient to apply traditional lossy data compression techniques, such as zero-suppression, that help to minimize data throughput and, therefore, the dead time of the system. However, for the readout of the SiPM sensors with less demanding requirements in terms of accuracy, a traditional zero-suppression is currently applied with a configuration that allows for a compression ratio of around 71%. The third stage in the NEXT detectors program, the NEXT-100 detector, is a 100 kg detector that instruments approximately five times more PMT sensors and twice the number of SiPM sensors than its predecessor, the NEXT-White detector, putting more pressure in the DAQ throughput, expected to be over 900 MB/s with the current configuration, which will worsen the dead time of the acquisition data system. This paper describes the data compression techniques applied to the sensor data in the NEXT-100 detector, which reduces data throughput and minimizes dead time while maintaining the event rate to the level of its predecessor, around 50 Hz.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Micro-Transfer Printing of Repeaters on Passive Interposer

Silicon-based sensors are central to particle physics experiments and particle tracking detectors. New-generation Large Focal Plane Arrays (LFPAs) cover areas that extend beyond several square meters. Distributing power and transporting data across such areas while maintaining good signal integrity is a complicated challenge. Tiling the detector on an organic interposer would be far too expensive and take too much space while offering little to no advantage regarding signal integrity. Passive silicon interposers are much less expensive and more integrable but would worsen signal integrity because of their inherent higher dielectric constant. Active interposers are a good compromise from the economic and signal integrity standpoint; unfortunately, their yield trends to zero for areas greater than a reticle size, making this technology incompatible with our application. NHanced proposes to duplicate the behavior of a high-yield, low-cost active interposer by printing active microcomponents on a passive interposer with our die-to-wafer micro-transfer printing (MTP) technology. This resolves the signal integrity and power distribution limitations. In Phase I, we designed and simulated analog and digital repeaters to be MTPed onto a passive silicon interposer test wafer.

2.5D↗