Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Demand Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Job Scheduler-Driven Power Gateway for High Performance Computing

Power gateways in the form of a microgrid can incorporate multiple distributed energy resources (DER) in either grid forming or grid following mode and support high performance computing (HPC) power profiles including the large load-follow requirements observed in multi-user HPC systems. The microgrid’s flexibility to operate in either grid forming or grid following mode and to actively switch between these modes enables baseline power from multiple non-baseline DER while maintaining high power quality metrics for the HPC system. But this enormous flexibility in demand response and time of use shifting is generally programmed independently of any integration with an HPC job scheduler which can better inform the load shaping by the microgrid. While there are many existing approaches where the HPC job scheduler takes in information from the grid to make queue scheduling decisions, this work takes the opposite view and explores a scheduler where the jobs in the queue can directly impact the settings of the grid. Several HPC scheduler strategies are tested where the jobs in the queue directly impact the settings of a microgrid designed for HPC operation which is driving a datacenter with three classes of HPC architectures. The scheduler operation is shown using a microgrid with 64 kW of solar capacity and 320 kWh of battery over a period of 21 days operating with significant low-follow swings, a throttled grid, cloudy conditions, switching between grid following and grid forming modes, and a wide range of battery states-of-charge all while maintaining high quality power metrics. The scheduler provides a mechanism for the job queue to directly impact a power gateway like a microgrid and to improve HPC power outcomes such as maximizing renewable energy usage

microgrid↗

ambrosia: An R package for calculating and analyzing food demand that is responsive to changing incomes and prices

The ambrosia R package was developed to calculate food demand for staples and non-staple commodities that is responsive to changing levels of incomes and prices. ambrosia implements the framework to quantify food demand as established by Edmonds et al. (Edmonds et al. 2017) and allows the user to explore and estimate different variables related to the food demand system. Currently ambrosia provides 3 main functions: (1) calculation of food demand for any given set of parameters including income levels and prices (2) estimation of parameters within a given a dataset. Note: ambrosia is used to calculate parameters for the food demand model implemented in the Global Change Analysis Model(GCAM) (3) exploration and preparation of raw data before starting a parameter estimation

97 MATHEMATICS AND COMPUTING↗

Data-driven modeling to enhance municipal water demand estimates in response to dynamic climate conditions

Altered precipitation and temperature patterns from a changing climate will affect supply, demand, and overall municipal water system operations throughout the arid western U.S. While supply forecasts leverage hydrological models to connect climate influences with surface water availability, demand forecasts typically estimate water use independent of climate and other externalities. Stemming from an increased focus on seasonal water demand management, we use the Salt Lake City, Utah municipal water system as a test bed to assess model accuracy versus complexity trade-offs between simple climate-independent econometric-based models and complex climate-sensitive data-driven models to average to extreme wet and dry climate conditions—representative of a new climate normal. Here, the climate-independent model displayed low performance during extreme dry conditions with predictions exceeding 90% and 40% of the observed monthly and seasonal volumetric demands, respectively, which we attribute to insufficient model complexity. The climate-sensitive models displayed greater accuracy in all conditions, with an ordinary least squares model demonstrating a measurable reduction in prediction bias (3.4% vs. -27.3%) and RMSE (74.0 lpcd vs. 294 lpcd) compared to the climate-independent model. The climate-sensitive workflow increased model accuracy and characterized climate-demand interactions, demonstrating a novel tool to enhance water system management.

54 ENVIRONMENTAL SCIENCES↗

Sustainable Public Transport: Providing Responsive, On-Demand Service with Clean Energy

The National Renewable Energy Laboratory (NREL) uses the Mobility Energy Productivity (MEP) as a metric and a lens to guide applied research into high performance public mobility. In the current initiative to abate global warming, the US needs not only zero-emission vehicles in the transit fleet (such as buses and shuttles) but also time- and cost-effective services to connect people with goods, services and employment toward a high-quality of life. Our current transportation system is overly dependent on personally-owned automobiles for high quality mobility, with public modes being less viable in many areas. Simply electrifying the drivetrains of existing public transit modes will fail to improve the quality of mobility for those that do not have access to private automobiles. The slow rebound by transit from the pandemic reveals the need to reinvent public transit service. Using the MEP lens, NREL researchers have tracked various novel developments in the public mobility space, with the confluence of shared, on-demand transit (ODT) services using light duty vehicles emerging as a key enabler of high-efficiency public mobility. Deployments such as those in Arlington, TX, Dallas, TX, Fort Erie, ON, and Innisfil, ON showcase the use of fleets of light-duty vehicles as the basis for community circulation and first/last mile to intra-regional transit. ODT services have demonstrated improvements in being more time efficient for riders, more energy efficient in operation (even before the introduction of fully electric vehicles), as well as being cost effective. It appears that aspects of the long-awaited promise of Personal Rapid Transit from the 1970s are beginning to be realized through ODT deployments, leveraging transportation network company (TNC) logistics, popularized by Uber and Lyft, but applied to public mobility. Currently, manually driven ODT operations are already cost competitive with traditional transit systems on a cost per ride basis, and full automation promises to reduce costs by 50% while providing additional safety and verified customer service. Connecting these ODT systems with efficient and effective intra-regional backbone transit service is the next step, with transit agencies like DART providing early results. This discussion will walk through the evidence for this postulated outcome and show results from a series of case-studies.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

101 Surveys in 28 Days - Evaluating Response Rates to a Demanding Request

We report the results of a survey test conducted in advance of a series of community response tests (CRTs) to evaluate response to noise from NASA’s X-59 aircraft. The CRTs will require a substantial number of observations to generate a dose response curve and the timeframe is limited due to resource and scheduling constraints with an experimental aircraft. Within each CRT area, we will recruit a sample of residents in advance and ask them to fill out a brief survey each time the aircraft passes over. Respondents will be asked to fill out the survey either on the web or as part of an application they are able to download onto their mobile phones. On many days, respondents will be asked to fill out the survey for multiple passes. The survey test followed the proposed methodology of the CRTs, albeit gauging reactions to normal in-situ aircraft events. To demonstrate initial interest, we will present response rates to the recruitment portion of the survey test which used an ABS frame. We will then evaluate the ongoing response rates among the recruited population to a demanding survey schedule involving 101 surveys over a 28-day period. The response rate evaluation will focus on demographics, mode (app vs. web) and whether and how these change over time. We will use the results of this work to confirm or improve the design of the CRTs, ensuring the collection of data needed by NASA to evaluate the impact of this innovative technology.

response rates↗

Community-scale interaction of energy efficiency and demand flexibility in residential buildings

Demand-side management (DSM) strategies, including energy efficiency (EE) and demand flexibility (DF), contribute to cost-effective operation of the electricity grid. From a system-level perspective, such programs reduce costs, enhance reliability, and reduce network issues. Similarly, DSM programs help participating customers reduce utility bills while maintaining occupant comfort. Understanding the relationship between EE and DF is key to realizing the full potential of DSM programs. In this study, we modeled an all-electric residential community based on a 498-home community that is planned for construction in Fort Collins, Colorado in the United States. We used this community model to study the relationship between different EE measures, including building envelope upgrades and smart appliances, and DF enabled by a home energy management system (HEMS) responding to a time-varying tariff. Various EE levels in the homes – code-minimum, zero energy ready, and even higher levels of envelope efficiency – were simulated. DF is enabled by the HEMS, which coordinates behind-the-meter resources, including flexible building loads, PV, and home battery systems, to minimize utility bills while maintaining occupant comfort. When comparing to the code-minimum homes, EE upgrades alone reduce HVAC energy use during peak hours by up to 50% and the HVAC utility bill by up to $312/year. With the addition of HEMS, the average daily peak demand can be reduced by up to 0.58 MW or 1.2 kW/home in the higher envelope efficiency homes. The combination of EE upgrades, HEMS, and home battery systems is expected to save homeowners up to $590/year while increasing community load flexibility. However, HEMS and home battery systems are less effective in increasing the DF in the more efficient homes due to the lower load.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Demand Bidding Model for Multi-Product Industrial Plants

The growing contribution of renewable energy sources has increased volatility and uncertainty in electricity markets, challenging traditional grid operation paradigms. Demand bidding (DB), a market participation model where (large) electricity users communicate their willingness to pay for electricity to the grid operator, was shown in previous work to enhance grid stability and lower generation cost. We present a DB model for multi-product industrial plants, based on an extended optimal power flow problem where the plant dynamics are represented using autoregressive with extra inputs (ARX) models. We compare DB to price-based demand-side management, showing that, under certain assumptions, the two approaches are equivalent, while DB provides more transparency and predictability to the grid operator. A case study based on an industrial air separation unit is discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment of peak power demand reduction available via modulation of building ventilation systems.

Peak power demand strains electrical grids and increases cost of electricity generation, transmission and distribution infrastructure. Many studies have examined ways of reducing peak power demand, including modification of room air temperature setpoints or reduction of lighting levels. However, very few or no studies have examined the peak power reduction resource offered by temporary curtailment of building ventilation systems. For this reason, we conducted a simulation campaign in which we examined the resource offered by temporary ventilation curtailment in commercial buildings of different use types across the United States and in residences in the state of California, with the essential constraint that any changes resulted in air quality acceptable to occupants through additional ventilation to compensate for the curtailment. To do this, we employed previously validated building models implemented in the airflow and contaminant transport tool CONTAM and building thermal and systems modeling tool EnergyPlus, in some cases co-simulated. Overall, results show savings are highly dependent on building type and climate but range from 0–2 W/ft 2 and up to 40% of total peak building power demand. Depending on building type, this power shed can be conducted for 1.5–8 h before acute exposure or odor concerns are expected, assuming a safety factor of 2. This reduction is of the same magnitude as that offered by thermal control strategies such as setpoint increase, or from lighting reduction strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Accuracy of hourly energy predictions for demand flexibility applications

Decarbonization goals in the United States electricity sector are increasing the levels of renewable energy generation in the electricity supply system, and are driving increased attention to building electrification, which will increase the magnitude and shift the timing of the electricity system peak. These changes are motivating new approaches to coordinate building electricity demand with low-carbon renewable generation, elevating the importance of demand flexibility (DF) in buildings and the need to quantify the temporal impacts of DF. In this paper, we first characterize the hourly predictive accuracy of six commonly used baseline models in an application context of quantifying building-level load shift. Our analysis revealed insights such as hours of the day (afternoons), periods of the week (weekends), and seasons (summer) that were predicted with more accuracy than other time periods. In addition, the analysis showed tendencies toward overprediction or underprediction of load. Secondly, we provide the first published investigation of baseline erosion from repeated dispatch of building load shifting. We observed that as the baseline period is pushed back further from the prediction day, the distribution of errors across baseline model predictions increases, with notable inflection points near the three-week erosion point for two of the three models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrification Futures Study: Operational Analysis of U.S. Power Systems with Increased Electrification and Demand-Side Flexibility

This report provides a high-resolution U.S. national-scale power systems assessment of scenarios with widespread electrification using detailed grid simulations. We find that high electrification scenarios envisioned in the Electrification Futures Study can be operated at the hourly level to meet future increased levels of electrified demand and, under the most aggressive cases, with up to 66% of generation from wind and solar technologies. The analysis also examines the value of flexibility from demand by supporting system operability under high electrification and high renewable systems. Demand-side flexibility—especially flexibility from newly electrified loads—is found to enhance the operational efficiency by reducing VRE curtailment and increasing utilization of generators with lower operating costs. It can also enhance the ability of electrification to decarbonize the energy sector.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Stochastic scheduling for commercial building cooling systems: considering uncertainty in zone temperature prediction

Here, this paper presents the first attempt to address the uncertainty in zone temperature prediction with stochastic optimization. The uncertain zone temperature is a process uncertainty and has not been considered in the existing stochastic optimization for building control. To fill this gap, we proposed a novel formulation of stochastic optimization to handle process uncertainty in building control. Specifically, we first examined the accuracy of a typical linear model for predicting zone temperature. We then formulated the scheduling of the building cooling system as a stochastic optimization problem over a 24-hour look-ahead period to minimize the electricity cost of the studied building cooling system. After that, we applied the proposed stochastic load scheduling (SLS) to a direct expansion (DX) cooling system that serves a medium office building. Through simulation with a detailed building energy simulation software, EnergyPlus, we evaluated the operational cost and the thermal comfort compared with a deterministic load scheduling. The operation cost of scheduling was found to vary with the level of zone temperature prediction uncertainty. The proposed SLS can mitigate the impacts of uncertain zone temperature predictions on both operational cost and thermal comfort. The evaluation results indicate that the proposed SLS works better when the uncertainty level is more significant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Transactive Energy Network Template Metamodel

While transactive energy, which is defined as an allocation of electricity based on dynamically discovered values or prices, has been extensively studied, its uptake and use has been slow. This report describes a tool, the transactive network template, which should hasten the creation and uptake of transactive energy networks. Some basic principles of transactive energy are familiar from existing wholesale electricity markets. Locational prices are calculated today for zones within bulk electric transmission systems. Locational prices differ while accounting for the locational costs of electricity generation and the losses and constraints incurred when electricity is transmitted from generators and distributed to consumers. A transactive energy network might include these transmission zones. However, current research strives to apply transactive energy also in electricity distribution circuits, buildings, and even for individual generating and consuming devices. At the same time, researchers explore how to apply transactive energy in real time during increasingly shorter time intervals. Automated computational agents become necessary as transactive energy becomes applied to smaller circuit zones and at faster dynamic timescales. A transactive energy network is an example of a multi-agent system. Each zone in the network is represented by its transactive agent, which makes decisions for and acts on behalf of a business entity that is responsible for and manages one of the circuit regions. A transactive energy network is also an example of a decentralized, distributed control system. Control decisions and responsibilities are distributed among the network’s transactive agents. The transactive agents are independent; that is, there typically is no centralized authority or oversight function. Instead, transactive agents exchange transactive signals and thereby negotiate the prices and quantities of electricity that they will exchange. Initially, the circuit regions and responsibilities of transactive agents appear to be very dissimilar. Each circuit region may comprise transmission, distribution, or building-level circuits. Each has a unique position and electrical connectivity within the transactive energy network. Each possesses unique assets that either generate or consume electricity, and these (e.g., renewable energy generator, diesel generator, aggregate utility load, building load, space conditioning, refrigerator, etc.) may further differ in their price flexibility and in their strategies for responding to dynamic electricity prices. Given such diversity, an implementer’s first inclination might be to start from scratch to define all these devices and to engineer their seemingly unique interactions. Given that each implementer’s perspective may be narrow within a transactive energy network, it is unlikely that uniquely engineered systems would interact well. This is where the transactive network template is applicable. The transactive network template is a metamodel that has been developed to guide implementers as they configure their own transactive agent within a network of such agents. The object-oriented design of the transactive network template provides basic code object types that may be used and extended by implementers to represent each of the assets in their circuit region. These objects further facilitate the transactive agent’s necessary computations, which are divided among responsibilities to schedule power usage, balance electric supply and demand, and coordinate the exchange of electricity with the other transactive agents. This report addresses the conceptual transactive network template design. Implementers are directed to more formal design documents and reference implementations. A Python™-based1 reference implementation of the transactive network template has been coded, and three implementations have been configured to represent a national laboratory and two university campuses. Version 2 of the transactive node template generalizes the market class and its methods to facilitate multiple, and more diverse market coordination mechanisms than were facilitated by and demonstrated using Version 1. Version 3 includes new Appendix B, which addresses the designs of methods that would make dynamic prices track approved electricity rates. In the future, the author wishes to make the transactive network template more generally applicable to networks that require more accurate power flow. Development of the transactive network template is jointly funded by the U.S. Department of Energy (DOE) Energy Efficiency and Renewable Energy and the DOE Office of Electricity. In late 2015, one of the first projects to be funded by the DOE Grid Laboratory Modernization Laboratory Consortium was the Clean Energy and Transactive Campus project, led by Pacific Northwest National Laboratory. DOE funds were matched by an investment by the Washington Department of Commerce through its Clean Energy Fund. The transactive network template was developed to guide the implementation of transactive energy networks within this project’s scope.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The dissociation of subjective measures of mental workload and performance

Dissociation between performance and subjective workload measures was investigated in the theoretical framework of the multiple resources model. Subjective measures do not preserve the vector characteristics in the multidimensional space described by the model. A theory of dissociation was proposed to locate the sources that may produce dissociation between the two workload measures. According to the theory, performance is affected by every aspect of processing whereas subjective workload is sensitive to the amount of aggregate resource investment and is dominated by the demands on the perceptual/central resources. The proposed theory was tested in three experiments. Results showed that performance improved but subjective workload was elevated with an increasing amount of resource investment. Furthermore, subjective workload was not as sensitive as was performance to differences in the amount of resource competition between two tasks. The demand on perceptual/central resources was found to be the most salient component of subjective workload. Dissociation occurred when the demand on this component was increased by the number of concurrent tasks or by the number of display elements. However, demands on response resources were weighted in subjective introspection as much as demands on perceptual/central resources. The implications of these results for workload practitioners are described.

Yeh, Y. H.↗

Mobility Energy Productivity Evaluation of On-Demand Transit: A Case Study in Arlington, Texas

On-demand transit (ODT) systems are increasing in number and size. To evaluate and quantify outcomes, the research team utilizes the mobility energy productivity (MEP) metric, which is a holistic accessibility measure, to analyze and compare the mobility of various transportation modes in Arlington, Texas. The MEP tool is applied to the ODT system in Arlington, Texas, as well as to five existing transportation modes (driving, transportation network company, transit, biking, and walking). Six ODT scenarios are also analyzed and compared. The analysis is focused on the opportunities that an ODT system presents for transportation disadvantaged communities (DACs) with low rates of car ownership. Although driving received the highest MEP score—a finding typical for a U.S.A. city— the results for the ODT system reveal that it serves those in DACs effectively, helping to achieve an equity design goal. ODT improved the average MEP score across the service area by 83% when considering only accessible, nonprivate vehicle modes (biking, transit, and ODT). For the ODT scenarios, decreasing the wait time by 50% compared with the baseline scenario led to a nearly 160% increase in the MEP score, whereas increasing the ODT travel speed by 21% led to an 80% improvement in the MEP score. As analyzed through the MEP tool, here this paper demonstrates how ODT can enhance mobility, particularly for DACs. The results of an MEP analysis can be used by researchers and transit agencies to compare transportation modes and improve the effectiveness of transportation systems across a service area.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Price response of waste resources under demand shocks: four case studies

To quantify potential price changes of waste feedstocks that may be caused by increased demand, this study explored four case studies: 1) recyclable materials at local waste collection and recycling facilities in seven US states, 2) recyclable materials on internationally traded markets, 3) a wood-powered plant in Reading, PA, and 4) an MSW-powered plant in Tulsa, OK. The four case studies provided a total of ninety-one waste material price observations yielding twenty-seven price-supply relationships expressed as price elasticity of supply (PES) and unit price change with change in demand. For the two case studies related to recyclable materials with a global market shock, price changes vary widely from $0.08-$7.84 per ton with each percent change in demand. For the two case studies related to local market shocks in biomass used for energy, observed price changes range from $0.08-$0.23 per ton per percent change in demand. Based on these results, a base range of $0.10-$0.20 per ton per percent change in demand is recommended for local market shocks. I.e., for a facility that collects organic wastes on the order of 200,000-400,000 tons per year at price near zero, a doubling of demand could increase procurement prices by about $10.00-$20.00 per ton. Actual price changes with respect to change in demand may be non-linear. Shocks with broader geographic extent may increase price response due to a reduced opportunity for surrounding markets to mitigate localized market changes.

09 BIOMASS FUELS↗