Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DIAGNOSIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Microscopic diagnosis of universal geometric responses in fractional quantum Hall liquids

Topological quantum liquids contain internal degrees of freedom that are coupled to geometric response. Yet, an explicit and microscopic identification of the geometric response remains difficult. Here, taking notable fractional quantum Hall (FQH) states as typical examples, we systematically investigate a promising protocol—the Dehn-twist deformation on the torus geometry—to probe the geometric response of correlated topological states and establish the relation between such response and universal properties of pertinent states. Based on analytical derivations and numerical simulations, we find that the geometry-induced Berry phase encodes features for a broad class of FQH states at the Laughlin, hierarchy, Halperin and non-Abelian Moore-Read fillings. Our findings conclusively demonstrate that the adiabatic Dehn-twist deformation can faithfully capture rich geometric and topological information, including the Hall viscosity and topological spin of the pertinent FQH state and the chiral central charge of the underlying edge conformal field theory. Our approach provides a powerful way to reveal topological orders of generic FQH states and address previously open questions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diagnosis of information scrambling from Hamiltonian evolution under decoherence

We apply a quantum teleportation protocol based on the Hayden-Preskill thought experiment to quantify how scrambling a given quantum evolution is. It has an advantage over the direct measurement of out-of time ordered correlators when used to diagnose the information scrambling in the presence of decoherence effects stemming from a noisy quantum device. We demonstrate the protocol by applying it to two physical systems: Ising spin chain and SU(2) lattice Yang-Mills theory. To this end, we numerically simulate the time evolution of the two theories in the Hamiltonian formalism. The lattice Yang-Mills theory is implemented with a suitable truncation of Hilbert space on the basis of the Kogut-Susskind formalism. On a two-leg ladder geometry and with the lowest nontrivial spin representations, it can be mapped to a spin chain, which we call Yang-Mills-Ising model and is also directly applicable to future digital quantum simulations. Here, we find that the Yang-Mills-Ising model shows the signal of information scrambling at late times.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Single-Shot Diagnosis of Electron Energy Evolution via Streaked Betatron X Rays in a Curved Laser Wakefield Accelerator

We report on an experimental observation of the streaking of betatron x rays in a curved laser wakefield accelerator. The streaking of the betatron x rays was realized by launching a laser pulse into a plasma with a transverse density gradient. By controlling the plasma density and the density gradient, we realized the steering of the laser driver, electron beam, and betatron x rays simultaneously. Furthermore, we observed an energy-angle correlation of the streaked betatron x rays and utilized it in diagnosing the electron acceleration process in a single-shot mode. Our work could also find applications in advanced control of laser beam and particle propagation. More importantly, the angular streaked betatron x ray has an intrinsic spatiotemporal correlation, which makes it a promising tool for single-shot pump-probe applications.

43 PARTICLE ACCELERATORS↗

Diagnosis of PV Cell Antireflective Coating Degradation Resulting From Hot-Humid High-Voltage Potential Aging

Corrosion of the antireflective coating on a photovoltaic cell ("ARc corrosion") has previously been observed in studies using hot-humid test conditions with external high-voltage (HV) bias. This study primarily focuses on known vulnerable legacy aluminum back surface field cells in mini-modules (MiMos) put through comparative stepped stress tests. Each cell type had MiMos at +1500 V, -1500 V, or unbiased ("Voc") potential, which were sequentially subjected to test conditions of 60 degrees C/60% relative humidity (RH) for 96 h, as in International Electrotechnical Commission Technical Specification 62804-1; 70 degrees C/70% RH for 200 h; and 85 degrees C/85% RH for 200 h. Characterizations at each step included visual camera and electroluminescence (EL) imaging, colorimetry, and current-voltage curve tracing. Final characterizations included: Suns-Voc, spatial mapping of external quantum efficiency, high-resolution photoluminescence, EL, and dark lock-in thermography imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy, and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos from previous studies that underwent stepped HV aging and separate outdoor aged full-sized modules. ARc corrosion was specifically seen for the glass/encapsulant/cell side of the +1500 V (HV+) stressed MiMos and modules. Appearance, color, and reflectance were the most distinguishing characteristics relative to glass corrosion, gridline corrosion and delamination, and other concurrent degradation modes. SEM/EDS and SAM identified the conversion of silicon nitride to hydrated silica, hydrous silica, or hydrated amorphous silica, which preferentially occurred at the edges and tips of the pyramidal textured cell surface.

14 SOLAR ENERGY↗

Diagnosis of PV Cell Passivation Degradation Resulting from Hot-Humid, High Voltage Potential Aging

Corrosion of the antireflective coating on the cell ("AR c corrosion") was previously observed in studies using hot-humid test conditions with external high voltage (HV) bias. Because AR c corrosion is not well understood, mini-modules (MiMos) were examined in a comparative experiment using PERC and PERT as well as legacy Al-BSF cells. For separate MiMos with the cell circuit electrical at +1500 V, -1500 V, or unbiased "V oc", test conditions in the comparative study included 60degrees C/60% RH for 96 h, as in IEC TS 62804-1; 70degrees C/70%RH for 200 h; and 85degrees C/85% RH for 200 h. Characterizations at each read point included: camera and electroluminescence (EL) imaging, colorimetry, and I-V curve tracing. Characterizations at the final read point included: SunsVoc; spatially mapping external quantum efficiency (EQE); high resolution: photoluminescence (PL), EL, and dark lock-in thermographic (DLIT) imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS) and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos (stepped HV aging) and full-sized modules (outdoor aging) from previous studies. AR c corrosion was specifically observed for the glass/encapsulant/cell side of +1500 V (HV+) stressed MiMos, where appearance, color, and reflectance were the characteristics most distinguished relative to simultaneously occurring degradation modes. SEM/EDS and SAM identified conversion of silicon nitride to silicon oxide or hydrous silica, preferentially occurring at the edges and tips of the pyramidal textured cell surface.

aging↗

Perturbation-Based Diagnosis of False Data Injection Attack Using Distributed Energy Resources

Modern smart grid relies on various sensor measurements for its operational control. In a successful false data injection attack, the attacker manipulates the measurements from the grid sensors such that undetected errors are introduced into the estimates of the system parameters leading to catastrophic situations. This paper proposes a novel perturbation based false data injection attack detection mechanism that utilizes inverter based distributed energy resources (DERs) to create low magnitude perturbation signal in the distribution system voltage that is inconsequential to the normal grid operation. Two voltage sensitivity analysis based algorithms are designed to identify the optimal set of DERs that can create the voltage perturbation signal of desired magnitude. An analytical method of voltage sensitivity analysis is used to compute the magnitude of voltage perturbation signal at each node in a computationally efficient manner. Then, a detection mechanism is developed that checks for the presence of the perturbation sequence in each sensor measurement. A sensor measurement is deemed authentic if the voltage perturbation signal is present in the data. In case of sensor malfunction or cyber-attack, the perturbation signal will not be present in the measurement data. Performance of the proposed attack detection mechanism is validated via simulation of the IEEE 69 bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of a laboratory-developed multiplex real-time PCR assay for diagnosis of syphilis, herpes and chancroid genital ulcers in four public health laboratories in the USA

Objective To evaluate the field performance of a multiplex PCR (M-PCR) assay for detection of herpes simplex virus (HSV)-1 and HSV-2, Treponema pallidum ( T. pallidum ) and Haemophilus ducreyi ( H. ducreyi ) in genital ulcer disease (GUD) specimens. Methods GUD M-PCR was performed on 186 remnant specimens, previously collected for HSV testing, by four public health laboratories (PHLs) and the Laboratory Reference and Research Branch (LRRB) at the Centers for Disease Control and Prevention. The results from the PHLs were compared with those of LRRB, which served as the reference testing method, and percentage agreement was calculated. Results HSV was detected in 31 of 52 (59.6%), 20 of 40 (50%), 43 of 44 (97.7%) and 19 of 50 (38.0%) specimens from PHL1, PHL2, PHL3 and PHL4, respectively. There were seven discrepant results for HSV, and the overall percent agreement between the PHLs and the LRRB was 94%–100%, with a kappa value of 0.922, which demonstrates high agreement. T. pallidum was identified in 7 of 51 (13.7%) specimens from PHL1 with 94.1% agreement and in 2 of 40 (5.0%) specimens from PHL2 with 100% agreement. The LRRB identified three additional T. pallidum -positive specimens from PHL1. The kappa value (0.849) for T. pallidum testing suggests good agreement. Consistent with the LRRB results, no T. pallidum was detected in specimens from PHL3 and PHL4, and H. ducreyi was not detected at any of the study sites. Conclusions The GUD M-PCR assay performed well in four independent PHLs and 12 suspected syphilis cases were identified in this study. The M-PCR assay could provide improved diagnostic options for GUD infections in state and local PHLs.

Infectious Diseases↗

Injection, confinement, and diagnosis of electrons and positrons in a permanent magnet dipole trap

Abstract Prerequisites for the goal of studying long-lived, magnetically confined, electron–positron pair plasmas in the laboratory include the injection of both species into the trap, long trapping times, and suitable diagnostic methods. Here we report recent progress on these tasks achieved in a simple dipole trap based on a supported permanent magnet. For the injection of electrons, both an $$\textbf{E}\times B$$ E × B drift technique (of a $$\sim $$ ∼ 2– $$\upmu $$ μ A, 6-eV beam) and “edge injection” (from a filament emitting a few mA and biased to some tens of volts) have been demonstrated; the former is suitable for low-density beams with smaller spatial and velocity spreads, while the latter employs fluctuations arising from collective behavior. To diagnose the edge-injected electrons, image potentials and currents induced on a wall probe, the magnet case, and wall electrodes were measured. Confinement of drift-injected positrons, measured experimentally, exhibited at least two well-separated timescales. Simulations reproduced this qualitatively, using a simple model of elastic collisions with residual background gas, and point to small adjustments for increasing trapping times. In a major upgrade to diagnostic capabilities, 25 bismuth germanate detectors, placed in three reentrant ports, are able to localize annihilation gammas, which will be used in future experiments to distinguish between different loss channels. Graphical abstract

von der Linden, J. (ORCID:0000000327477813)↗

Mathematical Framework Underlying the In Situ Electrochemical Diagnosis of Adsorbed Intermediates Formed during Redox Reactions at Electrode Surfaces

Previously, we have presented an electrochemical technique wherein an electroactive tracer species is employed to probe the rate-limiting factors governing redox reactions at an electrode surface. In this technique, the electrode is first held potentiostatically to facilitate a redox process (step 1), and then the potential is released to open circuit conditions (step 2) so as to monitor the time-dependent re-equilibration of the electrode potential in the presence of the tracer. The time-dependent potential response in step 2 has been shown to contain information about diffusion—limited or desorption—limited steps, enabling in situ probing of the electrochemistry at the electrode surface during step 1. In the present contribution, a theoretical model governing the transient response in step 2 is developed for two limiting cases: diffusion—limited and desorption—limited recovery of the electrode potential. Mathematical modeling shows that, during re-equilibration, the step 2 potential transient corresponding to a case where step 1 involves surface adsorbed species which undergo desorption in step 2 exhibits a much longer time constant than that when re-equilibration occurs under diffusion limitations. The mathematical framework presented herein provides a sound fundamental basis for applying the aforementioned technique to studying adsorption-desorption processes during electrochemistry. Also, technique limitations are presented in light of the modeling findings.

25 ENERGY STORAGE↗

Ultrasonic Nondestructive Diagnosis of Cylindrical Batteries Under Various Charging Rates

Lithium-ion batteries have been used increasingly as electrochemical energy storage systems for electronic devices and vehicles. It is important to accurately estimate the state of charge (SoC) of a battery management system to control the battery operation to optimize performance, lifetime, and safety. The current work experimentally leverages ultrasonic diagnostic technology to investigate the SoC of lithium-ion batteries during the charge/discharge processes. A cylindrical-type nickel-cobalt-aluminum (NCA)–based 2500mAh 20A (INR18650-25R) battery was used for ultrasonic measurements with various charge/discharge rates of C/10.4, C/5.2, and C/1.3 at constant currents. The ultrasonic signals were analyzed for extracting wave velocity and wave attenuation. For all the testing rates, wave velocity increased in the charge process and decreased in the discharge process. Further, velocity profiles corresponding to lower rates of C/10.4 and C/5.2 exhibited primary peaks at the maximum SoCs, whereas the absolute wave velocity of C/1.3 rate showed primary peaks that occurred slightly after the SoC peak, indicating a delayed maximum Young's modulus. The wave attenuation computed for the C/10.4 rate had local maxima in the charge and discharge processes and depicted negative correlations with SoC, ranging from 0% to 18%, and positive correlations with SoC from 18% to 85%. On the other hand, the wave attenuation curves of the C/1.3 rate showed no local peaks and had negative correlations with SoC, ranging from 0% to 28%, and positive correlations with SoC ranging from 28% to 53%.

25 ENERGY STORAGE↗

Reagent-free Hyperspectral Diagnosis of SARS-CoV-2 Infection in Saliva Samples

Rapid, reagent-free pathogen-agnostic diagnostics that can be performed at the point of need are vital for preparedness against future outbreaks. Yet, many current strategies are pathogen-specific and require several reagents. We present hyperspectral sensing, using light to non-invasively measure the composition of several molecules to form a spectral signature, to overcome these barriers. To generate these spectral signatures, we present the ProSpectral TM V1, a novel, miniaturized hyperspectral platform with high spectral resolution with two mini-spectrometers. Furthermore, we developed state-of-the-art ML pipelines for near real-time analysis of spectral signatures in saliva samples. We found that we could accurately identify SARS-CoV-2 infection status in double-blinded saliva samples and demonstrate 100% accuracy on a hold out test dataset. To our knowledge, this establishes the fastest hyperspectral diagnostic platform and in a small form factor, and executable with liquid samples, without ligands or reagents, all while maintaining PCR level specificity and sensitivity.

59 BASIC BIOLOGICAL SCIENCES↗

Diagnosis of convective organization and cold pools using ARM datasets and evaluation of a unified convection parameterization (UNICON)

Tropical thunderstorms often cluster together. Studies have suggested that the degree to which the tropical thunderstorms are clustered impacts Earth's energy balance and water cycle, as well as extreme precipitation events. However, the processes controlling the spatial distribution of the thunderstorms are poorly understood and are not properly represented in most computer models for weather and climate prediction. Under the goals of better understanding how convection organizes at the mesoscale and advancing the representation of mesoscale convective organization in global climate models, we i) objectively quantified the degrees of convective organization and diagnosed cold pool processes using ARM field campaign observations, ii) examined the organization processes in storm-resolving model simulations, and iii) evaluated the impacts of mesoscale convective organization in global model simulations. The project yielded a firm reference against which the global model representation of mesoscale convective organization and cold pools can be evaluated against and shed new light into the role of parameterized convective organization in the global model simulation of the basic state and variability. Our results revealed two distinct phases of convective clustering during the two-day rain episodes (Cheng et al. 2018) and a new mechanism through which vertical wind shear in the low-troposphere can aid convective organization over tropical oceans (Cheng et al. 2020). It was demonstrated that the interactive representation of cold pools and mesoscale convective organization is key for global models to successfully simulate both the mean state and intraseasonal variability in the tropics (Ahn et al. 2019; 2020).

54 ENVIRONMENTAL SCIENCES↗