Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Curved detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

TESS Data Release Notes: Sector 24, DR35

These Data Release Notes provide information on the processing and export of data from the Transiting Exoplanet Survey Satellite (TESS). The data products included in this data release are full frame images (FFIs), target pixel fi les, light curve fi les, collateral pixel fi les, cotrending basis vectors (CBVs), and Data Validation (DV) reports, time series, and associated xml fi les. These data products were generated by the TESS Science Processing Operations Center (SPOC, Jenkins et al., 2016) at NASA Ames Research Center from data collected by the TESS instrument, which is managed by the TESS Payload Operations Center (POC) at Massachusetts Institute of Technology (MIT). The format and content of these data products are documented in the Science Data Products Description Document (SDPDD). The SPOC science algorithms are based heavily on those of the Kepler Mission science pipeline, and are described in the Kepler Data Processing Handbook (Jenkins, 2019).2 The Data Validation algorithms are documented in Twicken et al. (2018) and Li et al. (2019). The TESS Instrument Handbook (Vanderspek et al., 2018) contains more information about the TESS instrument design, detector layout, data properties, and mission operations. The TESS Mission is funded by NASA's Science Mission Directorate.

TESS↗

The "Puck" Energetic Charged Particle Detector: Design, Heritage, and Advancements

Energetic charged particle detectors characterize a portion of the plasma distribution function that plays critical roles in some physical processes, from carrying the currents in planetary ring currents to weathering the surfaces of planetary objects. For several low-resource missions in the past, the need was recognized for a low-resource but highly capable, mass-species-discriminating energetic particle sensor that could also obtain angular distributions without motors or mechanical articulation. This need led to the development of a compact Energetic Particle Detector (EPD), known as the "Puck" EPD (short for hockey puck), that is capable of determining the flux, angular distribution, and composition of incident ions between an energy range of approximately 10 kiloelectronvolts to several megaelectronvolts. This sensor makes simultaneous angular measurements of electron fluxes from the tens of kiloelectronvolts to about 1 megaelectronvolt. The same measurements can be extended down to approximately 1 kiloelectronvolt per nucleon,with some composition ambiguity. These sensors have a proven flight heritage record that includes missions such as MErcury Surface, Space ENvironment, GEochemistry, and Ranging (MESSENGER) and New Horizons, with multiple sensors on each of Juno, Van Allen Probes, and Magnetospheric Multiscale. In this review paper we discuss the Puck EPD design, its heritage, unexpected results from these past missions and future advancements. We also discuss high-voltage anomalies that are thought to be associated with the use of curved foils, which is a new foil manufacturing processes utilized on recent Puck EPD designs. Finally, we discuss the important role Puck EPDs can potentially play in upcoming missions.

Clark, G.↗

Capacitance–voltage modeling of mid-wavelength infrared nBn detectors

Capacitance–voltage measurements are a powerful technique to determine doping profiles of semiconductor pn junctions and Schottky barrier diodes. The measurements were recently extended to III-V-based mid-wavelength nBn infrared detectors, and absorber doping densities have been extracted using the widely accepted Schottky approximation, where the potential drop across the device is assumed to be across the depleting absorber layer. However, this approach is limited to when the absorber region of the nBn is under high reverse bias and thus is only able to extract the absorber region doping profile. Here, we introduce a semi-analytical model that is capable of extracting barrier dopant polarity, doping concentration, and thickness, as well as contact and absorber layer doping concentrations, all from a capacitance–voltage measurement. Rather than solely considering the potential drop across the depleting layers, it considers the potential drop across the accumulating layer as well. This negative charge accumulation occurs for the contact and absorber layers in the case of reverse and forward biases, respectively. This allows for a single model to be applied to a capacitance–voltage curve at forward and reverse biases and it can provide regions of bias where the absorber transitions from depletion to accumulation. We compare the agreement of the semianalytical model with modeling results from commercially available finite element method software and experimental capacitance–voltage data. Finally, we show that the method is consistent with the Schottky approximation of extracting absorber doping densities at high reverse bias and discuss the model's limitations.

Physics↗

J/ ψ elliptic and triangular flow in Pb-Pb collisions at \( \sqrt{s_{\mathrm{NN}}} \) = 5 . 02 TeV

The inclusive J/ ψ elliptic ( v 2 ) and triangular ( v 3 ) flow coefficients measured at forward rapidity (2 . 5 < y < 4) and the v 2 measured at midrapidity (| y | < 0 . 9) in Pb-Pb collisions at \( \sqrt{s_{\mathrm{NN}}} \) = 5 . 02 TeV using the ALICE detector at the LHC are reported. The entire Pb-Pb data sample collected during Run 2 is employed, amounting to an integrated luminosity of 750 μ b – 1 at forward rapidity and 93 μ b – 1 at midrapidity. The results are obtained using the scalar product method and are reported as a function of transverse momentum p T and collision centrality. At midrapidity, the J/ ψ v 2 is in agreement with the forward rapidity measurement. The centrality averaged results indicate a positive J/ ψ v 3 with a significance of more than 5 σ at forward rapidity in the p T range 2 < p T < 5 GeV/ c . The forward rapidity v 2 , v 3 , and v 3 /v 2 results at low and intermediate p T ( p T ≲ 8 GeV/ c ) exhibit a mass hierarchy when compared to pions and D mesons, while converging into a species-independent curve at higher p T . At low and intermediate p T , the results could be interpreted in terms of a later thermalization of charm quarks compared to light quarks, while at high p T , path-length dependent effects seem to dominate. The J/ ψ v 2 measurements are further compared to a microscopic transport model calculation. Using a simplified extension of the quark scaling approach involving both light and charm quark flow components, it is shown that the D-meson v n measurements can be described based on those for charged pions and J/ ψ flow.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

RATIR: Reionization and Transients Infra-Red Camera. A New Instrument to Identify High Red-Shift GRBs

We are currently constructing the cryogenic infrared portion of the RATIR instrument at NASA's Goddard Space Flight Center (GSFC) in collaboration with University of California, Berkeley (UCB) and The University of Mexico (UNAM). The infrared instrument will consist of two 2048x2048 Hawaii 2RG detectors, one on axis and one off axis using diachronic. The detectors will be operated using state-of-the-art Teledyne SIDECAR (System Image, Digitizing, Enhancing, Controlling, And Retrieving) ASICs (Application- Specific Integrated Circuits) similar to NIRSpec on JWST. The visible portion of the instrument is currently being developed at UCB consisting of two CCD imagining cameras. Once completed, the two sections will be integrated into the RATIR instrument. Mounted on a dedicated, fully-automated 1.5-m telescope, the instrument will provide rapid (<10 min) identification of VHR GRBs allowing high-resolution spectroscopic follow-up observations with large aperture telescopes possible. The hosting Observatorio Astronomico Nacional of the Universidad Nacional Autonoma de Mexico (UNAM), located on the Sierra de San Pedro Martir in Baja California, Mexico, provides great seeing (-1 aresec), good weather, dark skies, and significant sky coverage so that RATIR will detect a significant number of Swift afterglows. While not all GRBs will be at high red shifts, the resulting light curves, combined with X-ray/UV observations, will address several open questions, including the nature of both "dark GRBs" and the GRB emission mechanism.

Rapchun, David A.↗

SEARCHING FOR MESONIC DARK MATTER WITH THE HEAVY PHOTON SEARCH EXPERIMENT

Several highly-sensitive astrophysical experiments over the past couple of decades have demonstrated that the current abundance of visible Standard Model matter cannot explain galactic rotation curves, the expansion history of the Universe, or the apparent warping of light in empty space. Instead, one finds strong agreement with this body of experimental results upon positing the existence of an invisible particulate field, dark matter. Namely, a cold, weakly interacting dark matter component can explain all these phenomena. A number of accelerator-based experiments have been developed to search for the weak couplings/interactions of these particles, many of them concentrating on particle models with masses of tens to thousands of GeV. A relatively new, well-motivated model is a dark sector coupled to the Standard Model via a dark photon. The current abundance of dark matter can be obtained if one assumes that dark matter is coupled to light by a MeV to GeV particle with a U(1) symmetry. The parameter space of these models remains largely unexplored because they are difficult to probe experimentally. In this thesis, I analyze data from the Heavy Photon Search (HPS) detector, whose two detector halves closely surround the electron beam, providing acceptance to far-forward boosted interactions. This forward acceptance to highly boosted particles yields unprecedented sensitivity to MeV-scale invariant masses. I exhaustively optimize the offline reconstruction of the HPS detector. Each reconstruction object, from Silicon Vertex Tracker hits to tracks, is studied to maximize acceptance of dark matter events. I then use the 2021 run data to search for one model of dark-photon-mediated matter, the Strongly Interacting Massive Particle (SIMP). SIMP models provide self-interacting dark matter candidates that can form bound states resembling dark mesons. HPS can detect SIMPs through the decay of a dark vector boson (either a dark ¿ or ¿) into e+e- pairs. I obtain exclusion contours for SIMPs using both an optimized cuts-based selection and a machine-learning-based selection, advancing our knowledge of the nature of dark matter.

O'Dwyer, Rory [Stanford Univ., CA (United States).↗

Flexible Soft X-Ray Image Sensors based on Metal Halide Perovskites With High Quantum Efficiency

Soft X-ray imaging is a powerful tool to explore the structure of cells, probe material with nanometer resolution, and investigate the energetic phenomena in the universe. Conventional soft X-ray image sensors are by and large Si-based charge coupled devices that suffer from low frame rates, complex fabrication processes, mechanical inflexibility, and required cooling below -60 °C. Here, a soft X-ray photodiode is reported based on low-cost metal halide perovskite with comparable performance to commercial Si-based device. Nanothrough network electrode minimized the optical loss due to the shadowing of insensitive layers, while a multidimensional perovskite heterojunction is generated to reduce the photo-generated carrier loss. Further, this strategy promoted a record quantum efficiency of 8 × 10 3 % without cooling, several orders of magnitude greater than the previously achieved. Flexible and curved soft X-ray imaging arrays are fabricated based on this high-performance device structure, demonstrating stable soft X-ray response and sharp imaging capabilities. This work highlights the low-cost and efficient perovskite photodiode as a strong candidate for the next-generation soft X-ray image sensors.

36 MATERIALS SCIENCE↗

Direct evidence of microstructure dependence of magnetic flux trapping in niobium

Abstract Elemental type-II superconducting niobium is the material of choice for superconducting radiofrequency cavities used in modern particle accelerators, light sources, detectors, sensors, and quantum computing architecture. An essential challenge to increasing energy efficiency in rf applications is the power dissipation due to residual magnetic field that is trapped during the cool down process due to incomplete magnetic field expulsion. New SRF cavity processing recipes that use surface doping techniques have significantly increased their cryogenic efficiency. However, the performance of SRF Nb accelerators still shows vulnerability to a trapped magnetic field. In this manuscript, we report the observation of a direct link between flux trapping and incomplete flux expulsion with spatial variations in microstructure within the niobium. Fine-grain recrystallized microstructure with an average grain size of 10–50 µm leads to flux trapping even with a lack of dislocation structures in grain interiors. Larger grain sizes beyond 100–400 µm do not lead to preferential flux trapping, as observed directly by magneto-optical imaging. While local magnetic flux variations imaged by magneto-optics provide clarity on a microstructure level, bulk variations are also indicated by variations in pinning force curves with sequential heat treatment studies. The key results indicate that complete control of the niobium microstructure will help produce higher performance superconducting resonators with reduced rf losses 1 related to the magnetic flux trapping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Simons Observatory: science goals and forecasts for the enhanced Large Aperture Telescope

We describe updated scientific goals for the wide-field, millimeter-wave survey that will be produced by the Simons Observatory (SO). Significant upgrades to the 6-meter SO Large Aperture Telescope (LAT) are expected to be complete by 2028, and will include a doubled mapping speed with 30,000 new detectors and an automated data reduction pipeline. In addition, a new photovoltaic array will supply most of the observatory's power. The LAT survey will cover about 60% of the sky at a regular observing cadence, with five times the angular resolution and ten times the map depth of the Planck satellite. The science goals are to: (1) determine the physical conditions in the early universe and constrain the existence of new light particles; (2) measure the integrated distribution of mass, electron pressure, and electron momentum in the late-time universe, and, in combination with optical surveys, determine the neutrino mass and the effects of dark energy via tomographic measurements of the growth of structure at redshifts z ≲ 3; (3) measure the distribution of electron density and pressure around galaxy groups and clusters, and calibrate the effects of energy input from galaxy formation on the surrounding environment; (4) produce a sample of more than 30,000 galaxy clusters, and more than 100,000 extragalactic millimeter sources, including regularly sampled AGN light-curves, to study these sources and their emission physics; (5) measure the polarized emission from magnetically aligned dust grains in our Galaxy, to study the properties of dust and the role of magnetic fields in star formation; (6) constrain asteroid regoliths, search for Trans-Neptunian Objects, and either detect or eliminate large portions of the phase space in the search for Planet 9; and (7) provide a powerful new window into the transient universe on time scales of minutes to years, concurrent with observations from the Vera C. Rubin Observatory of overlapping sky.

79 ASTRONOMY AND ASTROPHYSICS↗

SQUID Readout of a High-$Q$ Superconducting $LC$ Resonator

We demonstrate the readout of a superconducting $LC$ resonator, with $Q \approx 2 \times 10^{6}$ at approximately 250 kHz, using a dc SQUID followed by a SQUID series-array amplifier readout chain. We find that $Q$ depends on the SQUID flux-bias point, increasing near the shallow-slope point of the SQUID modulation curve and decreasing near the steep-slope point, consistent with the previously observed SQUID damping effects. From this variation, we infer the SQUID effective input impedance. We further infer the effective temperature of the resonator circuit from the resonance peak in the noise spectrum and show that it also depends on the SQUID flux-bias point, suggesting a possible contribution from SQUID back-action noise. This system provides a working prototype for future experiments based on lumped-element resonators with SQUID readout, in particular low-mass axion searches within the DMRadio program.

FOS: Physical sciences↗

On Orbit Measurement of Response vs. Scan Angle for the Infrared Bands on TRMM/VIRS

The Visible and Infrared Scanner on the Tropical Rainfall Measuring Mission (TRMM/VIRS) is a whiskbroom imaging radiometer with two reflected solar bands and three emissive infrared bands. All five detectors are on a single cooled focal plane. This configuration necessitated the use of a paddlewheel scan mirror to avoid the effects of focal plane rotation that arise when using a scan mirror that is inclined to its axis of rotation. System radiometric requirements led to the need for protected silver as the mirror surface. Unfortunately, the SiO(x) coatings currently used to protect silver from oxidation introduce a change in reflectance with angle of incidence (AOI). This AOI dependence results in a modulation of system level response with scan angle. Measurement of system response vs. scan angle (RVS) was not difficult for the VIRS reflected solar bands, but attaining the required accuracy for the IR bands in the laboratory was not possible without a large vacuum chamber and a considerable amount of custom designed testing apparatus. Therefore, the decision was made to conduct the measurement on-orbit. On three separate occasions, the TRMM spacecraft was rotated about its pitch axis and, after the nadir view passed over the Earth's limb, the VIRS performed several thousand scans while viewing deep space. The resulting data has been analyzed and the RVS curves generated for the three IR bands are being used in the VIRS radiometric calibration algorithm. This, to our knowledge, the first time this measurement has been made on-orbit. Similar measurements are planned for the EOS-AM and EOS-PM MODIS sensors and are being considered for several systems under development. The VIRS on-orbit results will be compared to VIRS and MODIS system level laboratory measurements, MODIS scan mirror witness sample measurements and modeled data.

Barnes, William L.↗

The Spectral Evolution of Gamma-Ray Bursts

The proposed project was a continuation of our work on the spectral evolution of gamma-ray bursts begun when the Co-I on this proposal. Lyle Ford, was my graduate student. In the proposal we discussed two projects. The first was finishing and publishing the last chapter of Professor Ford's thesis. In this research effort we looked for correlations in the energies of pairs of counts recorded by the BATSE Spectroscopy Detectors within a short time of each other. A greater correlation within a short time would indicate that the observed broadband spectrum is really composed of narrowband spectral components which last for a short time and which rapidly sum to the observed spectrum. We did not find any evidence for such narrowband emission, and are setting limits on its presence. Professor Ford is revising the last chapter of his thesis for publication with my participation. The second project was a continuation of my study of the cross-correlations between the gamma-ray burst lightcurves in different energy bands. I published a first study with this technique (1997. Ap.J., 486, 928) which showed that "hard-to-soft" spectral evolution is prevalent both within and between the bursts' intensity spikes. I proposed to continue developing this technique. However, I have been somewhat disillusioned about using this methodology quantitatively since it averages the spectral evolution on a given timescale over the entire burst. Nonetheless, I have been applying the technique to new bursts which are scientifically interesting for other reasons. Attached I include the cross-correlations for the burst GRB 990123, the burst during which ROTSE discovered an optical transient. The solid curve is the autocorrelatl'on of BATSE's channel 3 (100-300 keV), while the dashed, dot-dashed and 3 dots-dashed curves are the crosscorrelations of channel 3 with channels 1 (25-50 keV), 2 (50-100 keV), and 4 (300-2000 keV). The order of, and separation between, the curves on the positive lag side indicate "hard-to-soft" evolution on all timescales, while the FWHM of the crosscorrelations shows that the intensity spikes are narrower at high energy than at low energy. I have also been participating with my colleague on the BATSE team on other spectral evolution studies. Note that while I continue as a member of the BATSE team, I no longer receive funding from the team. For example, Preece et al. (1998, Ap.J., 496, 849) showed that the high energy spectral index varies during a burst, usually following a "hard-to-soft" trend. In addition, we have just submitted a catalog (Preece et al. 1999, Ap. J., submitted) of time-resolved spectral fits.

Band, David L.↗

Automated co-adding and energy calibration of large array microcalorimeter data with zero sample knowledge

State-of-the-art microcalorimeter spectrometers now contain large detector arrays with hundreds of individual pixels. Each individual pixel outputs a unique and non-linear response with respect to deposited energy. This work describes a pattern-recognition algorithm to combine these responses into a single energy-calibrated histogram, referred to as co-adding pixels. Photo-peaks from different pixels are matched together based upon how well the match aligns the centroids and heights of neighboring peaks. This usually results in around 100 co-adding calibration points from 30 to 300 keV for a several day acquisition of plutonium items with masses between 0.5 and 10 grams. An additional algorithm energy-calibrates this co-added spectrum using the fluoresced K x-ray emissions from a tantalum absorber and inherent x-ray escape peaks from the tin absorbers. Both algorithms operate without knowledge of the source and are fully automated. This work presents results from the acquisitions of high and low burnup plutonium, 10% enriched uranium, a 153 Gd calibration source, and a 57 Co+ 166m Ho calibration source. In all measurements, resolution defined as the full-width at half-maximum (FWHM) of photo-peaks is preserved between the individual pixel and co-added spectra at around 65 eV for incident photon energies between 60 and 208 keV. The energy calibration algorithm is approximate and yields a calibration curve off by an average of around 200 eV for incident photon energies between 60 and 208 keV.

47 OTHER INSTRUMENTATION↗

Characterization of proton-induced damage in thick, p-channel skipper-CCDs

Here, in this work, we characterize the radiation-induced damage in two thick, p-channel skipper-CCDs irradiated unbiased and at room temperature with 217-MeV protons. We evaluate the overall performance of the sensors and demonstrate their single-electron/single-photon sensitivity after receiving a fluence on the order of 10 10 protons/cm 2 . Using the pocket-pumping technique, we quantify and characterize the proton-induced defects from displacement damage. We report an overall trap density of 0.134 traps/pixel for a displacement damage dose of 2.3 × 10 7 MeV/g. Three main proton-induced trap species were identified, V 2 , C i O i and V n O m , and their characteristic trap energies and cross sections were extracted. We found that while divacancies are the most common proton-induced defects, C i O i defects have a greater impact on charge integrity at typical operating temperatures because their emission-time constants are comparable or larger than typical readout times. To estimate ionization damage, we measure the characteristic output transistor curves. We found no threshold voltage shifts after irradiation. Our results highlight the potential of skipper-CCDs for applications requiring high-radiation tolerance and can be used to find the operating conditions in which effects of radiation-induced damage are mitigated.

47 OTHER INSTRUMENTATION↗

Flexible Vanadium Dioxide Photodetectors for Visible to Longwave Infrared Detection at Room Temperature

Abstract Flexible optoelectronics is a rapidly growing field, with a wide range of potential applications. From wearable sensors to bendable solar cells, curved displays, and curved focal plane arrays, the possibilities are endless. The criticality of flexible photodetectors for many of these applications is acknowledged, however, devices that are demonstrated thus far are limited in their spectral range. In this study, flexible photodetectors are demonstrated using a VO x nanoparticle ink, with an extremely broad operating wavelength range of 0.4 to 20 µm. This ink is synthesized using a simple and scalable wet‐chemical process. These photodetectors operate at room temperature and exhibit minimal variance in performance even when bent at angles of up to 100 ° at a bend radius of 6.4 mm. In addition, rigorous strain testing of 100 bend and release cycles revealed a photoresponse with a standard deviation of only 0.55%. This combination of mechanical flexibility, wide spectral response, and ease of fabrication makes these devices highly desirable for a wide range of applications, including low‐cost wearable sensors and hyperspectral imaging systems.

36 MATERIALS SCIENCE↗

SiC Optically Modulated Field-Effect Transistor

An optically modulated field-effect transistor (OFET) based on a silicon carbide junction field-effect transistor (JFET) is under study as, potentially, a prototype of devices that could be useful for detecting ultraviolet light. The SiC OFET is an experimental device that is one of several devices, including commercial and experimental photodiodes, that were initially evaluated as detectors of ultraviolet light from combustion and that could be incorporated into SiC integrated circuits to be designed to function as combustion sensors. The ultraviolet-detection sensitivity of the photodiodes was found to be less than desired, such that it would be necessary to process their outputs using high-gain amplification circuitry. On the other hand, in principle, the function of the OFET could be characterized as a combination of detection and amplification. In effect, its sensitivity could be considerably greater than that of a photodiode, such that the need for amplification external to the photodetector could be reduced or eliminated. The experimental SiC OFET was made by processes similar to JFET-fabrication processes developed at Glenn Research Center. The gate of the OFET is very long, wide, and thin, relative to the gates of typical prior SiC JFETs. Unlike in prior SiC FETs, the gate is almost completely transparent to near-ultraviolet and visible light. More specifically: The OFET includes a p+ gate layer less than 1/4 m thick, through which photons can be transported efficiently to the p+/p body interface. The gate is relatively long and wide (about 0.5 by 0.5 mm), such that holes generated at the body interface form a depletion layer that modulates the conductivity of the channel between the drain and the source. The exact physical mechanism of modulation of conductivity is a subject of continuing research. It is known that injection of minority charge carriers (in this case, holes) at the interface exerts a strong effect on the channel, resulting in amplification of the photon-detection signal. A family of operating curves characterizing the OFET can be generated in a series of measurements performed at different intensities of incident ultraviolet light.

Tabib-Azar, Massood↗

A Study of the Radiation Tolerance of CVD Diamond to 70 MeV Protons, Fast Neutrons and 200 MeV Pions

We measured the radiation tolerance of commercially available diamonds grown by the Chemical Vapor Deposition process by measuring the charge created by a 120 GeV hadron beam in a 50 μm pitch strip detector fabricated on each diamond sample before and after irradiation. We irradiated one group of samples with 70 MeV protons, a second group of samples with fast reactor neutrons (defined as energy greater than 0.1 MeV), and a third group of samples with 200 MeV pions, in steps, to (8.8±0.9) × 1015 protons/cm2, (1.43±0.14) × 1016 neutrons/cm2, and (6.5±1.4) × 1014 pions/cm2, respectively. By observing the charge induced due to the separation of electron–hole pairs created by the passage of the hadron beam through each sample, on an event-by-event basis, as a function of irradiation fluence, we conclude all datasets can be described by a first-order damage equation and independently calculate the damage constant for 70 MeV protons, fast reactor neutrons, and 200 MeV pions. We find the damage constant for diamond irradiated with 70 MeV protons to be 1.62±0.07(stat)±0.16(syst)× 10−18 cm2/(p μm), the damage constant for diamond irradiated with fast reactor neutrons to be 2.65±0.13(stat)±0.18(syst)× 10−18 cm2/(n μm), and the damage constant for diamond irradiated with 200 MeV pions to be 2.0±0.2(stat)±0.5(syst)× 10−18 cm2/(π μm). The damage constants from this measurement were analyzed together with our previously published 24 GeV proton irradiation and 800 MeV proton irradiation damage constant data to derive the first comprehensive set of relative damage constants for Chemical Vapor Deposition diamond. We find 70 MeV protons are 2.60 ± 0.29 times more damaging than 24 GeV protons, fast reactor neutrons are 4.3 ± 0.4 times more damaging than 24 GeV protons, and 200 MeV pions are 3.2 ± 0.8 more damaging than 24 GeV protons. We also observe the measured data can be described by a universal damage curve for all proton, neutron, and pion irradiations we performed of Chemical Vapor Deposition diamond. Finally, we confirm the spatial uniformity of the collected charge increases with fluence for polycrystalline Chemical Vapor Deposition diamond, and this effect can also be described by a universal curve.

36 MATERIALS SCIENCE↗

A Study of the Non-Thermal X-ray Emission of Shell-Type Supernova Remnants

The term of the forth year of the award is the period from March 15, 2003 to March 14, 2004. During this year, Dr. Thomas Pannuti, who had been performing most of the analyses, made a transition to a new position at Caltech. As of September 2003, Dr. Michael Stage began performing most of the analyses. Dr. Stage has begun constructing a detailed catalog of the spatial and spectral properties of young supernova remnants as described in sections 1 and 4 of the proposal. Specifically, he has focused on the analysis of Chandra ACIS data. The exquisite spatial resolution of the Chandra telescope and the modest spectral resolution of the CCDs make these data ideal. Dr. Stage has developed a standard set of procedures to reduce the data, generate telescope and detector response libraries and handle instrumental and celestial background subtraction. He has also adapted some existing code to automate spectral extraction and fitting. This code enables us to analyze the spectra of tens of thousands of small subregions of supernova remnants. Dr. Stage has recently applied this process to ACIS data for the supernova remnants Cas A and Kepler. The results include maps of the fitted parameters, such as individual line intensities and centroids (i.e. Doppler shifts), the electron temperature, and the absorption column density. These maps are more accurate than simple energy-cut images because it is difficult (and sometimes impossible) to cleanly separate the line emission from the underlying continuum (especially at low energies). It is now possible to identify the locations at which emission from each element is produced. Some of the elements are seen to be layered. The electron temperature maps demonstrate that the outer edges of Cas A and Kepler are very hot with weak lines. This emission is almost certainly synchrotron dominated. Therefore, not only are the maps interesting in and of themselves, but they also provide an unbiased means of easily identifying features in the remnants that can be studied in more detail using, for example, synchrotron models. Over the next year, Dr. Stage will refine the analysis procedures, expand the analyses to include several other remnants, present the results at major scientific conferences and publish a catalog of the results. Since this work is producing impressive results, we have applied for very long Chandra observations of Kepler and Tycho to obtain enough counts to take lull advantage of the technique. A i Ms observation of Cas A is already scheduled. Over the past year, I completed a joint, spectra,l analysis of some X-ray, radio, and gamma-ray data for the supernova remnant SN 1006. The results of this analysis show that the synchrotron and, hence, electron spectrum of the remnant is curved. The amount of curvature in the electron spectrum is quantitatively consistent with predictions of the amount of curvature in the proton spectrum of the remnant. A paper describing this work is nearly complete. When Dr. Pannuti left, he was analyzing X-ray data for the young supernova remnant G266.2-1.2. Dr. Pannuti found the first evidence of thermal X-ray emission from this remnant. Furthermore, like SN 1006, the cutoff frequency varies with azimuth along the bright northeastern rim. This work will be published during the coming year.

Allen, Glenn E.↗