Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cryogen”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

High deuteron and neutron yields from the interaction of a petawatt laser with a cryogenic deuterium jet

A compact high-flux, short-pulse neutron source would have applications from nuclear astrophysics to cancer therapy. Laser-driven neutron sources can achieve fluxes much higher than spallation and reactor neutron sources by reducing the volume and time in which the neutron-producing reactions occur by orders of magnitude. We report progress towards an efficient laser-driven neutron source in experiments with a cryogenic deuterium jet on the Texas Petawatt laser. Neutrons were produced both by laser-accelerated multi-MeV deuterons colliding with Be and mixed metallic catchers and by d (d,n) 3 He fusion reactions within the jet. We observed deuteron yields of 10 13 /shot in quasi-Maxwellian distributions carrying ~8-10% of the input laser energy. We obtained neutron yields greater than 10 10 /shot and found indications of a deuteron-deuteron fusion neutron source with high peak flux (>10 22 cm -2 s -1 ). The estimated fusion neutron yield in our experiment is one order of magnitude higher than any previous laser-induced dd fusion reaction. Though many technical challenges will have to be overcome to convert this proof-of-principle experiment into a consistent ultra-high flux neutron source, the neutron fluxes achieved here suggest laser-driven neutron sources can support laboratory study of the rapid neutron-capture process, which is otherwise thought to occur only in astrophysical sites such as core-collapse supernova, and binary neutron star mergers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Workflow Using a Cryogenic Coincident Fluorescence, Electron, and Ion Beam Microscope for Targeted Milling of Cells

This workflow enables lamella production targeting fluorescently labeled biological structures that are small (<1 μm in axial extent) and rare (1 copy per cell) using a cryogenic tri-coincident imaging platform. In conclusion, this platform integrates fluorescence microscopy, focused ion beam milling, and scanning electron microscopy at a single focal position and enables simultaneous fluorescence microscopy while milling.

Wang, Jue [California Institute of Technology (Cal↗

Commissioning the H i Observing Mode of the Beam Former for the Cryogenically Cooled Focal L-band Array for the GBT (FLAG)

We present the results of commissioning observations for a new digital beam-forming back end for the Focal plane L-band Array for the Robert C. Byrd Green Bank Telescope (FLAG), a cryogenically cooled Phased Array Feed (PAF) with the lowest measured T {sub sys}/η of any PAF outfitted on a radio telescope to date. We describe the custom software used to apply beam-forming weights to the raw element covariances to create research-quality spectral-line images for the new fine-channel mode, study the stability of the beam weights over time, characterize FLAG’s sensitivity over a frequency range of 150 MHz, and compare the measured noise properties and observed distribution of neutral hydrogen emission from several extragalactic and Galactic sources with data obtained with the current single-pixel L-band receiver. These commissioning runs establish FLAG as the preeminent PAF receiver currently available for spectral-line observations on the world’s major radio telescopes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase and Morphology of Water-ice Grains Formed in a Cryogenic Laboratory Plasma

Abstract Grains of ice are formed spontaneously when water vapor is injected into a weakly ionized laboratory plasma in which the background gas has been cooled to cryogenic temperatures comparable to those of deep space. These ice grains are levitated indefinitely within the plasma so that their time evolution can be observed under free-floating conditions. Using microscope imaging, ice grains are shown to have a spindle-like fractal structure and grow over time. Both crystalline and amorphous phases of ice are observed using Fourier transform infrared spectroscopy. A mix of crystalline and amorphous grains coexists under certain thermal conditions, and a linear mixing model is used on the ice absorption band surrounding 3.2 μ m to examine the ice phase composition and its temporal stability. The extinction spectrum is also affected by inelastic scattering as grains grow, and characteristic grain radii are obtained from Mie scattering theory and compared to size measurements from direct imaging. Observations are used to compare possible ice nucleation mechanisms, and it is concluded that nucleation is likely catalyzed by ions, as ice does not nucleate in the absence of plasma and impurities are not detected. Ice grain properties and infrared extinction spectra show similarity to observations of some astrophysical ices observed in protoplanetary disks, implying that the fractal morphology of the ice and observed processes of homogeneous ice nucleation could occur as well in such astrophysical environments with weakly ionized conditions.

Astronomy & Astrophysics↗

Enhanced Laser–Energy Coupling with Small-Spot Distributed Phase Plates (SG5-650) in OMEGA DT Cryogenic Target Implosions

Cryogenic deuterium–tritium ice target implosions on OMEGA with new small-spot ("SG5-650") distributed phase plates (DPP's) achieved an (11 +/- 4)% increase in energy coupling compared to implosions with standard-spot DPP's by decreasing the ratio of the laser spot diameter to the target diameter from 0.93 to 0.75. The SG5-650 DPP's provide a focus spot size of 674 um, which is defined as the diameter that encircles 95% of the measured beam energy compared to 834 um for the SG5-850. The hydrodynamic effciency, defined as the ratio of the kinetic energy in the imploding shell to the laser energy, increased from 4.5% to 5.0% based on radiation-hydrodynamic calculations benchmarked to shell trajectory and bang-time measurements. The higher coupling came with a trade-off of an increased hot-electron production as well as increased hydrodynamic instabilities seeded by a larger mode-10 amplitude from the beam port geometry, both of which may have affected the fusion neutron production and areal density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cryogenic heating system

The present invention relates to a cryogenic heating system including a plurality of stages to provide accurate temperature control. The system can be used to provide non-contact heating and cooling of a test sample by use of an inert fluid. Accurate temperature control can be maintained, e.g., by use of controllers to provide temperature feedback control.

42 ENGINEERING↗

Design and Characterization of a Phonon-Mediated Cryogenic Particle Detector with an eV-Scale Threshold and 100 keV-Scale Dynamic Range

We present the design and characterization of a cryogenic phonon-sensitive Si detector exploiting the Neganov-Trofimov-Luke effect to detect single-charge excitations. This device achieved 2.65(2) eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100 V bias. With a continuous-readout data acquisition system and an offline optimum-filter trigger, we obtain a 9.2 eV threshold with a trigger rate of the order of 20 Hz. The detector's energy scale is calibrated up to 120 keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid-state optical refrigerator for cryogenic cooling of payloads

A solid-state optical refrigerator for cryogenic cooling of a payload, the solid-state optical refrigerator including a laser cooling crystal including a first material and a dopant material; a thermal link including a second material, the thermal link being bonded to the laser cooling crystal and the thermal link being configured to be thermally linked to the payload to transfer heat conductively from the payload to the laser cooling crystal via the thermal link; and a vacuum chamber housing the laser cooling crystal and the thermal link, the vacuum chamber and thermal link having a combination of shape and coating such that laser and fluorescence light reflected off a wall of the vacuum chamber and laser and fluorescence light propagating within the thermal link are not incident on the payload.

Hehlen, Markus Peter↗

Cryogenic User Facilities for R&D on Noble Liquid Detectors and Low Temperature Devices

Cryogenic test facilities are critical infrastructure for physics experiments in a variety of fields, perhaps most notably for particle detection with noble liquid detectors, low-temperature device development, and quantum information research. However, considerable investment and technical knowledge are required to construct and operate such facilities. This white paper discusses proposals for user facilities aimed at broadening the availability of testing capabilities for the scientific community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Search for Low-mass Dark Matter and an Examination and Reduction of the Uncertainty due to the Photoelectric Absorption Cross Section using a Cryogenic Silicon Detector with Single-charge Sensitivity

Many astrophysical observations point to the abundant existence of dark matter (DM) in the universe composed of particles beyond the Standard Model. However despite numerous experiments using different techniques, DM particles have yet to be directly observed. The Super Cryogenic Dark Matter Search (SuperCDMS) SNOLAB experiment will employ silicon and germanium crystal detectors operated at temperatures as low as 15~mK to probe DM interactions using phonon and ionization signals. Recently, R\&D; facilities have developed gram-sized high-voltage eV-scale (HVeV) silicon detectors that achieve single-electron-hole-pair resolution. By probing effective DM-electron interactions, these devices can be used for searches of low-mass DM candidates.This dissertation presents a DM search experiment known as HVeV Run~2 that employs a second-generation HVeV detector operated in an above-ground laboratory at Northwestern University (IL, USA). Energy spectra are obtained from a blind analysis with 0.39 and 1.2\,g-days of exposure with the detector biased at 60 and 100\,V, respectively. The 0.93~gram detector achieves a 3\,eV phonon energy resolution, corresponding to a world-leading charge resolution of 3\,\% of a single electron-hole pair for a detector bias of 100\,V. With charge carrier trapping and impact ionization effects incorporated into the DM signal models, the resulting exclusion limits are reported for inelastic DM-electron scattering for DM masses from 0.5--$10^{4}$\,MeV$/c^{2}$; in the mass range from 1.2--50\,eV$/c^{2}$ the limits for dark photon and axion-like particle absorption are reported.Several DM search experiments, including HVeV Run~2, are sensitive to low-mass DM candidates that rely on the temperature-dependent photoelectric absorption cross section of silicon. However discrepancies in the underlying literature data result in dominating systematic uncertainties on the DM exclusion limits. In order to reduce these systematic uncertainties, this dissertation presents a novel method of making a direct, low-temperature measurement of the photoelectric absorption cross section of silicon at energies near the band gap (1.2--2.8\,eV).

Wilson, Matthew James↗

Electron subband degeneracy heat pump for cryogenic cooling

An unconventional method of solid-state cryogenic cooling utilizing the electron subband degeneracy of semiconductor heterostructures is discussed in this Letter. The working principle of using the electrons as the working medium to perform cyclic heat pumping under electrostatic subband "expansion" and "compression" is discussed. The calculated base temperature can reach below dilution refrigeration temperatures with the fundamental limit set by electron-phonon interaction. Using an ultra-wide GaAs quantum well as an example, the cooling power per unit volume is estimated to reach $0.85\ \rm \mu W/cm^3$ at $25\ \rm mK$ with a hot-side temperature of $42.5\ \rm mK$, suitable for applications such as quantum computing.

Wang, Chulin↗

Cryogenics Python Coding Calculations for Nitrogen & Helium Loss

Helium and Nitrogen are two significant chemical elements that are used to advance cryogenic scientific breakthroughs. Helium is a colorless, odorless, and tasteless gas that becomes liquid at (−452 °F). Nitrogen is a gas at its standard conditions; It becomes solid once temperatures reach below (-346 °F), and it boils and becomes a gas once temperatures reach above (-320 °F). During this research project I used a web-based interactive computing platform called Jupyter Lab to modify various python programs that calculate, and display helium and nitrogen inventory lost from three cryo plants

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Chip Development Toward 12 bit 10 GSPS Cryogenic ADC for Multiplexed Quantum Readout

This presentation presents the background and plan for the development toward a 12 bit 10 GSPS cryogenic ADC for multiplexed quantum readout. It covers the first two chips that have been taped out and tested. It includes results for those chips and provides some context to plans for the upcoming chip tapeout and the final one to come later.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation and Sensitivity Analysis of a Cryogenic Carbon Capture System for the Cement Industry

The talk will describe modeling and analysis of cryogenic systems for carbon capture from industrial point sources, thermodynamic and process simulation requirements to predict capture from typical flue gases, quantification of temperature and flow profiles for a range of gas feed compositions and capture levels, and impacts of process conditions and heat transfer on energy requirements for heat integration.

Paul, Brandon↗

Ion-Depleted Microenvironments During Lithium Deposition Revealed by Operando Freezing Cryogenic Electron Microscopy

Local structures and chemistry at active electrochemical interfaces are critical to determining safety, lifetime, and energy density in lithium metal batteries and other devices, but they are challenging to characterize at the nanoscale. We address this issue by developing operando freezing cryogenic electron microscopy (cryo-EM) to preserve battery interfaces in an active state for subsequent high-resolution characterization. We find that ion-depleted microenvironments form locally in the electrolyte adjacent to the lithium deposition interface in lithium metal batteries and are linked to heterogenous growth morphologies. These depleted environments arise locally even under conditions for which ion depletion is not predicted at steady state; this provides a mechanistic explanation for why dangerous lithium morphologies can still propagate in such systems and lead to thermal runaway. Operando freezing cryo-EM thus provides a method to directly visualize nanoscale heterogeneities that arise locally at electrochemical interfaces and play key roles in device failure.

CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS,E↗

Mechanical Actuation Mechanism Design for Cryogenic Microwave Cavities in Axion Dark Matter Searches

Resonant Microwave Cavities are placed in a strong magnetic field at cryogenic temperatures (~.1K) in order to try to convert axions into detectable photons. A major challenge is to tune the cavity to allow no interference with the desired environment used for the experiment, which enables the system to operate near absolute zero and maintain superconductivity, thereby reducing noise as much as possible. My project focuses on developing and testing a low-thermal-conductivity gear reduction system with a 1000:1 ratio for cavity tuning. This gear system could significantly improve the thermal and electromagnetic interference of the tuning mechanism, helping ADMX scan for axions more accurately.

Ortega, Giancarlo [Marquette U.; Fermilab]↗

A Sub-electron-noise Skipper-CCD Readout ASIC with Improved Channel-to-channel Isolation and an Integrated Cryogenic Voltage Reference

The MIDNA application specific integrated circuits (ASICs) are a series of skipper-CCD readout chips fabricated in a 65 nm low-power CMOS process that implement a correlated double sampling signal processing chain based on dual-slope integrators. They are capable of working from room to cryogenic temperatures, down to 84 K. The present iteration of the ASIC has been fabricated including several design updates and the addition of an on-chip voltage reference, resulting in improved performance. This work presents the main vulnerabilities solved, the changes carried out, and the resulting performance benefits. Measurements with a skipper-CCD and the ASIC at 140 K showed that the single-electron resolution can be reached by averaging the measured charge in the analog domain using the analog pile-up technique with a readout noise as low as 0.11 erms of equivalent charge for 1200 samples. The channel-to-channel crosstalk was also characterized showing values better than -62 dB.

Alcalde Bessia, Fabricio↗

A Sub-electron-noise Skipper-CCD Readout ASIC with Improved Channel-to-channel Isolation and an Integrated Cryogenic Voltage Reference

The MIDNA application specific integrated circuits (ASICs) are a series of skipper-CCD readout chips fabricated in a 65 nm low-power CMOS process that implement a correlated double sampling signal processing chain based on dual-slope integrators. They are capable of working from room to cryogenic temperatures, down to 84 K. The present iteration of the ASIC has been fabricated including several design updates and the addition of an on-chip voltage reference, resulting in improved performance. This work presents the main vulnerabilities solved, the changes carried out, and the resulting performance benefits. Measurements with a skipper-CCD and the ASIC at 140 K showed that the single-electron resolution can be reached by averaging the measured charge in the analog domain using the analog pile-up technique with a readout noise as low as 0.11 erms of equivalent charge for 1200 samples. The channel-to-channel crosstalk was also characterized showing values better than -62 dB.

Alcalde Bessia, Fabricio↗