Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Collective motion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Mechanical Resonant Sensing of Spin Texture Dynamics in a 2D Antiferromagnet

Abstract The coupling between the spin degrees of freedom and macroscopic mechanical motions, including striction, shearing, and rotation, has attracted wide interest with applications in actuation, transduction, and information processing. Experiments so far have established the mechanical responses to the long‐range ordered or isolated single spin states. However, it remains elusive whether mechanical motions can couple to a different type of magnetic structure, the non‐collinear spin textures, which exhibit nanoscale spatial variations of spin (domain walls, skyrmions,etc.) and are promising candidates to realize high‐speed computing devices. Here, collective spin texture dynamics is detected with nanoelectromechanical resonators fabricated from 2D antiferromagnetic (AFM) MnPS 3 with 10 −9 strain sensitivity. By examining radio frequency mechanical oscillations under magnetic fields, new magnetic transitions are identified with sharp dips in resonant frequency. They are attributed to collective AFM domain wall motions as supported by the analytical modeling of magnetostriction and large‐scale spin‐dynamics simulations. Additionally, an abnormally large modulation in the mechanical nonlinearity at the transition field infers a fluid‐like response due to ultrafast domain motion. The work establishes a strong coupling between spin texture and mechanical dynamics, laying the foundation for electromechanical manipulation of spin texture and developing quantum hybrid devices.

Chemistry↗

Cell and Particle Interactions and Aggregation During Electrophoretic Motion

The stability and pairwise aggregation rates of small spherical particles under the collective effects of buoyancy-driven motion and electrophoretic migration are analyzed. The particles are assumed to be non-Brownian, with thin double-layers and different zeta potentials. The particle aggregation rates may be enhanced or reduced, respectively, by parallel and antiparallel alignments of the buoyancy-driven and electrophoretic velocities. For antiparallel alignments, with the buoyancy-driven relative velocity exceeding the electrophoretic relative velocity between two widely-separated particles, there is a 'collision-forbidden region' in parameter space due to hydrodynamic interactions; thus, the suspension becomes stable against aggregation.

Wang, Hua↗

Adjusting a Full Body Model to Mitigate Inverse Kinematics Artifacts in Opensim

BACKGROUND: In support of Vibration Isolation and Stabilization (VIS) system development for Human Health Countermeasures (HHC) exercise systems in space, such as the European Enhanced Exploration Exercise Device (E4D) [1], dynamic quantities required to model the response of a proposed VIS while considering the effect of VIS motion on the forces between the human and VIS platform were obtained using motion capture data [2]. On occasion, large-amplitude oscillatory spikes were found in the subject’s linear and angular momentum derivatives, affecting analyses that depend on forces and moments derived from motion capture. The purpose of this investigation was to identify causes of these artifacts and techniques for their resolution. METHODS AND RESULTS: To obtain the required human dynamic quantities to drive the VIS simulation, motion capture data was collected containing recorded trajectories of passive retroreflective markers on body landmarks of an exercising subject. Since the full body Rajagopal model [3] was originally used to enhance gait analysis, upper body joints did not require large Ranges of Motion (ROM). We thus modified the Rajagopal model [4, 5] to allow it to be used for upper body intensive exercises like those common to the E4D. OpenSim Inverse Kinematics (IK) [6] was performed using these scaled subject models to generate the joint angles throughout the exercise while minimizing marker error. At times, the arms were observed to ‘snap’ from one configuration to another, causing spike artifacts. Following IK, a custom OpenSim plugin [7] was used to determine the required dynamic quantities including the rates of change of the linear and angular momenta of the human. Since motion capture is recorded at a larger time step than required by the VIS simulation, the human center of mass location was fit with splines and a second derivative taken to obtain the momentum derivative, allowing the VIS simulation to maintain conservation of momentum when appropriate. In a few cases during this stage, artifacts much larger than the expected noise of the second derivatives were introduced. Investigation of cases containing artifacts revealed several modifications that could be made to the OpenSim model to improve IK results. Since OpenSim models use Euler angles and rotation sequences, ‘gimbal lock’ would be encountered in the arms when raised 90 degrees to the side (e.g., T-pose, some hang clean exercise, etc.). This was resolved by reorienting the horizontal axes at the shoulder joint by 45 degrees, placing ‘gimbal lock’ outside common arm ROM, with the arm ROMs adjusted following this change. Elbow and wrist ROMs could also be adjusted to allow realistic motion while at the same time limiting the likelihood of unrealistic orientations. On occasion, the arms flipped backwards when raised above the head. This was prevented by using medial elbow markers in scaling and IK. When medial markers were not available, the acromial joint location in the unscaled model was shifted before model scaling to better align the arm with available markers. Lastly, artifacts which became apparent after taking the second derivatives of spline-fit data were found to occur in cases when the pelvis rotation limit prevented the full range of motion of an exercise. These issues were resolved by unclamping the pelvis rotation limit. Through this investigation, an understanding of conditions leading to IK artifacts was acquired allowing the automation of artifact detection. These artifact detection and mitigation techniques can be applied toward modeling of upper body motions in aerospace and other fields for improved IK results.

C A Bell↗

Software Processes SAR Motion-Measurement Data

Motion Measurement Processor (MMP) is one of three computer programs that are used together in the operation of a terrain-mapping dual-frequency interferometric synthetic-aperture-radar (SAR) system. The other two programs - Jurassicprok and Calibration Processor - are described in the two immediately preceding articles. MMP acquires all the motion and attitude data collected by onboard instrumentation systems, including radar, laser and camera metrology, inertial navigation systems, and Global Positioning System (GPS) receivers. MMP combines all this information and processes it into all the trajectory information needed to run Jurassicprok, which performs the interferometric processing and mapping functions. MMP includes several Kalman filters for combining and smoothing aircraft motion and attitude data, and least-squares inversion and filtering software tools for solving for interferometric baseline lengths. MMP synchronizes the motion and radar data. It combines the various measurement data into a unified, seven-dimensional reference system and puts out the resulting filtered trajectory and attitude data along with instructions for use of the data by Jurassicprok, as well as the command files used to operate Jurassicprok.

Freedman, Adam↗

Biomechanics of the Treadmill Locomotion on the International Space Station

Exercise prescriptions completed by International Space Station (ISS) crewmembers are typically based upon evidence obtained during ground-based investigations, with the assumption that the results of long-term training in weightlessness will be similar to that attained in normal gravity. Coupled with this supposition are the assumptions that exercise motions and external loading are also similar between gravitational environments. Normal control of locomotion is dependent upon learning patterns of muscular activation and requires continual monitoring of internal and external sensory input [1]. Internal sensory input includes signals that may be dependent on or independent of gravity. Bernstein hypothesized that movement strategy planning and execution must include the consideration of segmental weights and inertia [2]. Studies of arm movements in microgravity showed that individuals tend to make errors but that compensation strategies result in adaptations, suggesting that control mechanisms must include peripheral information [3-5]. To date, however, there have been no studies examining a gross motor activity such as running in weightlessness other than using microgravity analogs [6-8]. The objective of this evaluation was to collect biomechanical data from crewmembers during treadmill exercise before and during flight. The goal was to determine locomotive biomechanics similarities and differences between normal and weightless environments. The data will be used to optimize future exercise prescriptions. This project addresses the Critical Path Roadmap risks 1 (Accelerated Bone Loss and Fracture Risk) and 11 (Reduced Muscle Mass, Strength, and Endurance). Data were collected from 7 crewmembers before flight and during their ISS missions. Before launch, crewmembers performed a single data collection session at the NASA Johnson Space Center. Three-dimensional motion capture data were collected for 30 s at speeds ranging from 1.5 to 9.5 mph in 0.5 mph increments with a 12-camera system. During flight, each crewmember completed up to 6 data collection sessions spread across their missions, performing their normal exercise prescription for the test day, resulting in varying data collection protocols between sessions. Motion data were collected by a single HD video camera positioned to view the crewmembers' left side, and tape markers were placed on their feet, legs, and neck on specific landmarks. Before data collection, the crewmembers calibrated the video camera. Video data were collected during the entire exercise session at 30 Hz. Kinematic data were used to determine left leg hip, knee, and ankle range of motion and contact time, flight time, and stride time for each stride. 129 trials in weightlessness were analyzed. Mean time-normalized strides were found for each trial, and cross-correlation procedures were used to examine the strength and direction of relationships between segment movement pattern timing in each gravitational condition. Cross-correlation analyses between gravitational conditions revealed highly consistent movement patterns at each joint. Peak correlation coefficients occurred at 0% phase, indicating there were no lags in movement timing. Joint ranges of motion were similar between gravitational conditions, with some slight differences between subjects. Motion patterns in weightlessness were highly consistent at a given speed with those occurring in 1G, indicating that despite differing sensory input, subjects maintain running kinematics. The data suggest that individuals are capable of compensating for loss of limb weight when creating movement strategies. These results have important implications for creating training programs for use in weightlessness as practitioners can have greater confidence in running motions transferring across gravitational environments. Furthermore, these results have implications for use by researchers investigating motor control mechanisms and investigating hypotheses related to movement strategies when using sensory input that is dependent upon gravity.

DeWitt, John↗

THE PPMXL CATALOG OF POSITIONS AND PROPER MOTIONS ON THE ICRS. COMBINING USNO-B1.0 AND THE TWO MICRON ALL SKY SURVEY (2MASS)

USNO-B1.0 and the Two Micron All Sky Survey (2MASS) are the most widely used all-sky surveys. However, 2MASS has no proper motions at all, and USNO-B1.0 published only relative, not absolute (i.e., on the International Celestial Reference Frame (ICRS), proper motions. We performed a new determination of mean positions and proper motions on the ICRS system by combining USNO-B1.0 and 2MASS astrometry. This catalog is called PPMXL (VO access to the catalog is possible via http://vo.uni-hd.de/ppmxl), and it aims to be completed from the brightest stars down to about V {approx} 20 all sky. PPMXL contains about 900 million objects, some 410 million with 2MASS photometry, and is the largest collection of ICRS proper motions at present. As representative for the ICRS, we chose PPMX. The recently released UCAC3 could not be used because we found plate-dependent distortions in its proper motion system north of -20{sup 0} declination. UCAC3 served as an intermediate system for {delta} {<=} -20{sup 0}. The resulting typical individual mean errors of the proper motions range from 4 mas yr{sup -1} to more than 10 mas yr{sup -1} depending on observational history. The mean errors of positions at epoch 2000.0 are 80-120 mas, if 2MASS astrometry could be used, 150-300 mas else. We also give correction tables to convert USNO-B1.0 observations of, e.g., minor planets to the ICRS system.

79 ASTRONOMY AND ASTROPHYSICS↗

A Quasi-Static Method for Determining the Characteristics of a Motion Capture Camera System in a "Split-Volume" Configuration

To confidently report any data collected from a video-based motion capture system, its functional characteristics must be determined, namely accuracy, repeatability and resolution. Many researchers have examined these characteristics with motion capture systems, but they used only two cameras, positioned 90 degrees to each other. Everaert used 4 cameras, but all were aligned along major axes (two in x, one in y and z). Richards compared the characteristics of different commercially available systems set-up in practical configurations, but all cameras viewed a single calibration volume. The purpose of this study was to determine the accuracy, repeatability and resolution of a 6-camera Motion Analysis system in a split-volume configuration using a quasistatic methodology.

Miller, Chris↗

Effects of Command and Control Vehicle (C2V) Operational Environment on Soldier Health and Performance

The purpose of this project was to use NASA technology to assist the US Army in the assessment of motion sickness and performance of soldiers in the Command and Control Vehicle (C2V). Three different vehicle configurations were tested: oblique, (3 seats at a 20-degree angle from the direction of travel); perpendicular, (3 seats at a 90 degree angle); and 4-forward, (all seats faced forward). In all vehicles, the front seat faced forward. Sixteen men and eight women participated for 15 days: 2 days of classroom instruction; 12 days of field tests in the C2V, and 15 minutes of post-field test performance measures. Conditions for field tests were: an initial Park; four Moves (i.e., travel over a mixed terrain); and four Short-halts following movement. NASA task batteries, mood and symptom scales, and physiological data were collected during field tests. Motion sickness symptoms ranging from slight to severe were reported for all subjects. Conclusions were: (1) there was no difference between vehicle configurations; (2) there was a negative impact on crew performance and health when subjects attended to visual screens during vehicle movement; and (3) symptoms and performance degradation were not mitigated by intermittent short-halts.

Cowings, Patricia S.↗

Does a motion base prevent simulator sickness?

The use of high-fidelity motion cues to reduce the discrepancy between visually implied motion and actual motion is tested experimentally using the NASA Vertical Motion Simulator (VMS). Ten pilot subjects use the VMS to fly simulated S-turns and sawtooths which generate a high incidence of motion sickness. The subjects fly the maneuvers on separate days both with and without use of a motion base provided by the VMS, and data are collected regarding symptoms, dark focus, and postural equilibrium. The motion-base condition is shown to be practically irrelevant with respect to the incidence and severity of motion sickness. It is suggested that the data-collection procedure cannot detect differences in sickness levels, and the false cues of the motion condition are theorized to have an adverse impact approximately equivalent to the absence of cues in a fixed-base condition.

Sharkey, Thomas J.↗

Mapping quadrupole collectivity in the Cd isotopes: The breakdown of harmonic vibrational motion

The stable Cd isotopes have long been used as paradigms for spherical vibrational motion. Extensive investigations with in-beam {gamma} spectroscopy have resulted in very-well-established level schemes, including many lifetimes or lifetime limits. A programme has been initiated to complement these studies with very-high-statistics {beta} decay using the 8{pi} spectrometer at the TRIUMF radioactive beam facility. The decays of {sup 112}In and {sup 112}Ag have been studied with an emphasis on the observation of, or the placement of stringent limits on, low-energy branches between potential multi-phonon levels. A lack of suitable 0{sup +} or 2{sup +} three-phonon candidates has been revealed. Further, the sum of the B(E2) strength from spin 0{sup +} and 2{sup +} states up to 3 MeV in excitation energy to the assigned two-phonon levels falls far short of the harmonic-vibrational expectations. This lack of strength points to the failing of collective models based on vibrational phonon structures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prostate Bed Motion During Intensity-Modulated Radiotherapy Treatment

Purpose: Conformal radiation therapy in the postprostatectomy setting requires accurate setup and localization of the prostatic fossa. In this series, we report prostate bed localization and motion characteristics, using data collected from implanted radiofrequency transponders. Methods and Materials: The Calypso four-dimensional localization system uses three implanted radiofrequency transponders for daily target localization and real-time tracking throughout a course of radiation therapy. We reviewed the localization and tracking reports for 20 patients who received ultrasonography-guided placement of Calypso transponders within the prostate bed prior to a course of intensity-modulated radiation therapy at Fox Chase Cancer Center. Results: At localization, prostate bed displacement relative to bony anatomy exceeded 5 mm in 9% of fractions in the anterior-posterior (A-P) direction and 21% of fractions in the superior-inferior (S-I) direction. The three-dimensional vector length from skin marks to Calypso alignment exceeded 1 cm in 24% of all 652 fractions with available setup data. During treatment, the target exceeded the 5-mm tracking limit for at least 30 sec in 11% of all fractions, generally in the A-P or S-I direction. In the A-P direction, target motion was twice as likely to move posteriorly, toward the rectum, than anteriorly. Fifteen percent of all treatments were interrupted for repositioning, and 70% of patients were repositioned at least once during their treatment course. Conclusion: Set-up errors and motion of the prostatic fossa during radiotherapy are nontrivial, leading to potential undertreatment of target and excess normal tissue toxicity if not taken into account during treatment planning. Localization and real-time tracking of the prostate bed via implanted Calypso transponders can be used to improve the accuracy of plan delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New Dynamic Spin Rig Capabilities Used to Determine Rotating Blade Dynamics

The Dynamic Spin Rig Facility at the NASA Glenn Research Center is used to determine the structural response of rotating engine components without the effects of aerodynamic loading. Recently, this rig's capabilities were enhanced through the replacement of grease-lubricated ball bearings with magnetic bearings. Magnetic bearings offer a number of advantages--the most important here being that they not only fully support the rotor system, but excite it as well. Three magnetic bearings support the rotor and provide five axes of controlled motion: an x- and y-axis translation at each of two radial bearings and a z-axis translation in the vertical or axial direction. Sinusoidal excitation (most commonly used) can be imparted on the rotor through the radial magnetic bearings in either a fixed or rotating frame of reference. This excitation is added directly to the magnetic bearing control output. Since the rotor is fully levitated, large translations and rotations of the rotor system can be achieved. Some of the capabilities of this excitation system were determined and reported. The accelerations obtained at the tip of a titanium flat plate test article versus the swept sine excitation sent to both radial bearings in phase and perpendicular to the plane containing the two blades are shown. Recent tests required the excitation of fundamental bending and torsional blade resonances at rotor speeds up to 10,000 rpm. Successful fixed synchronous rotation of the excitation signal provided the best detectable blade resonant vibrations at excitation frequencies up to 1100 Hz for the particular blades of interest. A noncontacting laser measurement system was used to collect blade-tip motions. From these data, the amplitude and frequency of the motion could be determined as well as the blade damping properties. Damping could be determined using two methods: (1) free decay and (2) curve fitting the vibration amplitude as a function of frequency in and around the resonance of interest and using the half-power method. The free decay of a composite blade vibrating at its first bending resonance while rotating at 3000 rp is shown. This new system is currently being used to support the Efficient Low-Noise Fan project at Glenn. The damping properties of prototype hollow composite blades specially designed to reduce fan noise are currently being determined.

Provenza, Andrew J.↗

Electron collection by a highly positive satellite in the ionosphere: Test aprticle simulation

Collection of electrons by a satellite at a relatively high potential in low Earth orbit, including the effects of the satellite's orbital motion, remains a poorly understood phenomenon. Using a test particle simulation in which charged particle motion is tracked in prescribed electric fields, we calculate here the current collection and the nature of the energy distribution function of the electrons collected by the satellite, including the effects of the satellite orbital motion. Calculations of the collected current without the orbital motion show an excellent agreement with the current from the Parker-Murphy model, but with the orbital motion of the satellite the current collection is enhanced, the degree of enhancement depending on the size of the satellite sheath extending along the magnetic field line. In the latter case, the flow of electrons around the satellite shows some interesting behaviors including azimuthal E x B drift around the satellite, axial trapping along the magnetic field, and formation of field-aligned flow of electrons in the wake region. The total energy of the collected electrons is approximately equal e phi(sub 0), where phi(sub 0) is the satellite potential, but the partition of the energy into components parallel (W(sub parallel)) and perpendicular (W(sub perpendicular)) to the magnetic field shows interesting features. For the magnetic field along the polar axis Z, the energy distributions near the poles are perfectly field aligned, that is, the parallel energy (W(sub parallel) = e phi(sub 0). The perpendicular component (W(sub perpendicular)) progressively increases toward the 'equator' of the spherical satellite. For a sufficiently large bias potential phi(sub 0), the equatorial energy distributions f(W(sub parallel)) and f(W(sub perpendicular)) show fine structures having multiple peaks. These features of the distribution functions result from the chaotic motion of electrons and the associated coupling between the electron motions parallel and perpendicular to the magnetic field in strongly nonuniform electric fields near the satellite.

Singh, Nagendra↗

Spatiotemporal control of liquid crystal structure and dynamics through activity patterning

Active materials are capable of converting free energy into mechanical work to produce autonomous motion, and exhibit striking collective dynamics that biology relies on for essential functions. Controlling those dynamics and transport in synthetic systems has been particularly challenging. Here, we introduce the concept of spatially structured activity as a means of controlling and manipulating transport in active nematic liquid crystals consisting of actin filaments and light-sensitive myosin motors. In this work, simulations and experiments are used to demonstrate that topological defects can be generated at will and then constrained to move along specified trajectories by inducing local stresses in an otherwise passive material. These results provide a foundation for the design of autonomous and reconfigurable microfluidic systems where transport is controlled by modulating activity with light.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental study of the ion current to a cylindrical Langmuir probe taking into account a finite ion temperature

This article deals with the experimental verification of a theoretical radial model, developed by the authors, for the sheath that surrounds a cylindrical Langmuir probe immersed in a plasma in which the positive ion temperature, T{sub i}, is not negligibly small compared to the electron temperature, T{sub e}. The theoretical model is a generalization of the classical one developed for cold ions by Allen, Boyd, and Reynolds for the case of spherical probes, and extended by Chen for cylindrical ones. According to our theory, due to the positive ion thermal motion the ion current collected by the probe is increased with respect to the case of cold ions, so its influence must be considered in plasma diagnosis. An experimental device to accurately measure the I-V characteristic of a cylindrical probe in plasma, for which T{sub i}/T{sub e} {ne} 0, has been developed. Very good agreement has been found between the theoretical positive ion I-V probe characteristic and the experimental values by using a Sonin plot.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bare-tether cathodic contact through thermionic emission by low-work-function materials

A new material, C12A7:e{sup -} electride, which might present a work function as low as 0.6 eV and moderately high temperature stability, was recently proposed as coating for floating bare tethers. Arising from heating under space operation, current is emitted by thermionic emission along a thus coated cathodic segment. A preliminary study on the space-charge-limited (SCL) double layer in front of the cathodic segment is presented using Langmuir's SCL electron current between cylindrical electrodes and orbital-motion-limited ion-collection sheath. A detailed calculation of current and bias profiles along the entire tether length is carried out with ohmic effects and the transition from SCL to full Richardson-Dushman emission included. Analysis shows that in the simplest drag mode, under typical orbital and tether conditions, thermionic emission leads to a short cathodic section and may eliminate the need for an active cathodic device and its corresponding gas feed requirements and power subsystem, which results in a truly 'propellant-less' tether system for such basic applications as de-orbiting low earth orbit satellites.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nature of dynamic gradients, glass formation, and collective effects in ultrathin freestanding films

Significance The origin of spatially heterogeneous alterations in the dynamics of nanoconfined liquids has been a major question in physics, chemistry, and materials science for over 30 y. We combine simulation and theory to establish a unified predictive microscopic understanding in freestanding films at low to medium molecular weight, spanning from thick to ultrathin films. The simulation-based phenomenology of altered dynamics is theoretically predicted and understood based on a combination of coupled near-interface gradients of local caging constraints and interfacial and finite size-induced changes in a collective elastic barrier to motion. No invocation of any realized or incipient critical-like phenomenon is necessary, which may have broad implications for other confined systems and the mechanism of the bulk glass transition.

nanoconfinement↗

Review: knots and other new topological effects in liquid crystals and colloids

Abstract Humankind has been obsessed with knots in religion, culture and daily life for millennia, while physicists like Gauss, Kelvin and Maxwell already involved them in models centuries ago. Nowadays, colloidal particles can be fabricated to have shapes of knots and links with arbitrary complexity. In liquid crystals, closed loops of singular vortex lines can be knotted by using colloidal particles and laser tweezers, as well as by confining nematic fluids into micrometer-sized droplets with complex topology. Knotted and linked colloidal particles induce knots and links of singular defects, which can be interlinked (or not) with colloidal particle knots, revealing the diversity of interactions between topologies of knotted fields and topologically nontrivial surfaces of colloidal objects. Even more diverse knotted structures emerge in nonsingular molecular alignment and magnetization fields in liquid crystals and colloidal ferromagnets. The topological solitons include hopfions, skyrmions, heliknotons, torons and other spatially localized continuous structures, which are classified based on homotopy theory, characterized by integer-valued topological invariants and often contain knotted or linked preimages, nonsingular regions of space corresponding to single points of the order parameter space. A zoo of topological solitons in liquid crystals, colloids and ferromagnets promises new breeds of information displays and a plethora of data storage, electro-optic and photonic applications. Their particle-like collective dynamics echoes coherent motions in active matter, ranging from crowds of people to schools of fish. This review discusses the state of the art in the field, as well as highlights recent developments and open questions in physics of knotted soft matter. We systematically overview knotted field configurations, the allowed transformations between them, their physical stability and how one can use one form of knotted fields to model, create and imprint other forms. The large variety of symmetries accessible to liquid crystals and colloids offer insights into stability, transformation and emergent dynamics of fully nonsingular and singular knotted fields of fundamental and applied importance. The common thread of this review is the ability to experimentally visualize these knots in real space. The review concludes with a discussion of how the studies of knots in liquid crystals and colloids can offer insights into topologically related structures in other branches of physics, with answers to many open questions, as well as how these experimentally observable knots hold a strong potential for providing new inspirations to the mathematical knot theory.

Physics↗